Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
J Neurosurg Spine ; 40(2): 229-239, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-37976509

ABSTRACT

OBJECTIVE: The objective of this study was to evaluate the 24-month durability of pain relief, function, quality of life, and safety outcomes for patients with nonsurgical refractory back pain (NSRBP) treated with high-frequency spinal cord stimulation (SCS) within a large, national, multicenter randomized controlled trial (RCT). METHODS: Following the completion of an RCT comparing high-frequency SCS plus CMM with CMM alone for the treatment of NSRBP, patients gave additional consent for a follow-up extension to 24 months. Presented is the cohort analysis of all patients treated with high-frequency SCS following the optional crossover at 6 months. The outcomes assessed to 24 months included responder rate of ≥ 50% pain relief measured according to the visual analog scale [VAS]), disability (Oswestry Disability Index [ODI]), quality of life (EQ-5D 5-level [EQ-5D-5L]), opioid reduction. RESULTS: Of the 125 patients who received a permanent implant, 121 completed the 12-month follow-up, 101 gave additional consent for extended follow-up, and 98 completed the 24-month follow-up. At 24 months after implantation, the mean back pain VAS score was reduced by 73% and the responder rate was 82%. ODI and EQ-5D-5L both improved by at least double the minimal clinically important difference for each measure. No unexpected adverse events were observed, and the rates of serious adverse events (3.4%) and device explantations (4.8%) were low. CONCLUSIONS: The addition of high-frequency SCS to CMM in patients with NSRBP offers profound improvements at 24 months in pain, function, quality of life, and reduced opioid use. This study provides much-needed evidence to inform current clinical practice for managing patients with NSRBP.


Subject(s)
Chronic Pain , Spinal Cord Stimulation , Humans , Treatment Outcome , Analgesics, Opioid , Chronic Pain/therapy , Quality of Life , Back Pain/therapy , Spinal Cord
2.
Cureus ; 14(8): e28387, 2022 Aug.
Article in English | MEDLINE | ID: mdl-36176855

ABSTRACT

Frame-based stereotactic localization is an important step for targeting during a surgical procedure. The motion may cause artifacts in this step reducing the accuracy of surgical targeting. While modeling of motion in real-life scenarios may be difficult, herein we analyzed the case where motion was suspected to impact the localization step. In this case, a scan with and without motion was performed with a 3N localizer, allowing for a thorough analysis. Pseudo-bending of straight rods was seen when analyzing the data. This pseudo-bending appears to occur because head-frame motion during imaging acquisition decreases the accuracy of the subsequent reconstruction, which depends on Digital Imaging and Communications in Medicine (DICOM) metadata to specify the slice-to-slice location that assumes embedded object stability. Comparison of single-slice and multi-slice stereotactic localization allowed for comparative errors for each slice in a volume. This comparative error demonstrated low error when the patient was under general anesthesia and presumed not to have moved, whereas a higher error was present during the scan with motion. Pseudo-bending can be corrected by using only localizer fiducial-based information to reorient the pixels in the volume, thus creating a reoriented localizer scan. Finally, targeting demonstrated a low error of 0.1 mm (+/- 0.1 mm) using this reoriented localizer scan, signifying that this method could be used to improve or recover from motion problems. Finally, it is concluded that stability and elimination of motion for all images utilized for stereotactic surgery are critical to ensure the best possible accuracy for the procedure.

3.
J Neurosurg Spine ; : 1-12, 2022 Feb 11.
Article in English | MEDLINE | ID: mdl-35148512

ABSTRACT

OBJECTIVE: Spinal cord stimulation (SCS) at 10 kHz (10-kHz SCS) is a safe and effective therapy for treatment of chronic low-back pain. However, it is unclear from existing evidence whether these findings can be generalized to patients with chronic back pain that is refractory to conventional medical management (CMM) and who have no history of spine surgery and are not acceptable candidates for spine surgery. The authors have termed this condition "nonsurgical refractory back pain" (NSRBP) and conducted a multicenter, randomized controlled trial to compare CMM with and without 10-kHz SCS in this population. METHODS: Patients with NSRBP, as defined above and with a spine surgeon consultation required for confirmation, were randomized 1:1 to patients undergoing CMM with and without 10-kHz SCS. CMM included nonsurgical treatment for back pain, according to physicians' best practices and clinical guidelines. Primary and secondary endpoints included the responder rate (≥ 50% pain relief), disability (Oswestry Disability Index [ODI]), global impression of change, quality of life (EQ-5D-5L), and change in daily opioid use and were analyzed 3 and 6 months after randomization. The protocol allowed for an optional crossover at 6 months for both arms, with observational follow-up over 12 months. RESULTS: In total, 159 patients were randomized; 76 received CMM, and 69 (83.1%) of the 83 patients who were assigned to the 10-kHz SCS group received a permanent implant. At the 3-month follow-up, 80.9% of patients who received stimulation and 1.3% of those who received CMM were found to be study responders (primary outcome, ≥ 50% pain relief; p < 0.001). There was also a significant difference between the treatment groups in all secondary outcomes at 6 months (p < 0.001). In the 10-kHz SCS arm, outcomes were sustained, including a mean 10-cm visual analog scale score of 2.1 ± 2.3 and 2.1 ± 2.2 and mean ODI score of 24.1 ± 16.1 and 24.0 ± 17.0 at 6 and 12 months, respectively (p = 0.9). In the CMM arm, 74.7% (56/75) of patients met the criteria for crossover and received an implant. The crossover arm obtained a 78.2% responder rate 6 months postimplantation. Five serious adverse events occurred (procedure-related, of 125 total permanent implants), all of which resolved without sequelae. CONCLUSIONS: The study results, which included follow-up over 12 months, provide important insights into the durability of 10-kHz SCS therapy with respect to chronic refractory back pain, physical function, quality of life, and opioid use, informing the current clinical practice for pain management in patients with NSRBP.

4.
Oper Neurosurg (Hagerstown) ; 19(3): 302-312, 2020 09 01.
Article in English | MEDLINE | ID: mdl-31858143

ABSTRACT

BACKGROUND: Efficacy in deep brain stimulation (DBS) is dependent on precise positioning of electrodes within the brain. Intraoperative fluoroscopy, computed tomography (CT), or magnetic resonance imaging are used for stereotactic intraoperative localization (StIL), but the utility of biplanar X-ray has not been evaluated in detail. OBJECTIVE: To determine if analysis of orthogonal biplanar X-rays using graphical analysis (GA), ray tracing (RT), and/or perspective projection (PP) can be utilized for StIL. METHODS: A review of electrode tip positions comparing postoperative CT to X-ray methods was performed for DBS operations containing orthogonal biplanar X-ray with referential spheres and pins. RESULTS: Euclidean (Re) errors for final DBS electrode position on intraoperative X-rays vs postoperative CT using GA, RT, and PP methods averaged 1.58 mm (±0.75), 0.74 mm (±0.45), and 1.07 mm (±0.64), respectively (n = 56). GA was more accurate with a ventriculogram. RT and PP predicted positions that correlated with third ventricular structures on ventriculogram cases. RT was the most stable but required knowledge of the geometric setup. PP was more flexible than RT but required well-distributed reference points. A single case using the O-arm demonstrated Re errors of 0.43 mm and 0.28 mm for RT and PP, respectively. In addition, these techniques could also be used to calculate directional electrode rotation. CONCLUSION: GA, RT, and PP can be employed for precise StIL during DBS using orthogonal biplanar X-ray. These methods may be generalized to other stereotactic procedures or instances of biplanar imaging such as angiograms, radiosurgery, or injection therapeutics.


Subject(s)
Deep Brain Stimulation , Surgery, Computer-Assisted , Electrodes, Implanted , Humans , Imaging, Three-Dimensional , Tomography, X-Ray Computed , X-Rays
5.
Acta Neurochir (Wien) ; 158(3): 513-20, 2016 Mar.
Article in English | MEDLINE | ID: mdl-26743912

ABSTRACT

INTRODUCTION: Facial pain is often debilitating and can be characterized by a sharp, stabbing, burning, aching, and dysesthetic sensation. Specifically, trigeminal neuropathic pain (TNP), anesthesia dolorosa, and persistent idiopathic facial pain (PIFP) are difficult diseases to treat, can be quite debilitating and an effective, enduring treatment remains elusive. METHODS: We retrospectively reviewed our early experience with stimulation involving the trigeminal and sphenopalatine ganglion stimulation for TNP, anesthesia dolorosa, and PIFP between 2010-2014 to assess the feasibility of implanting at these ganglionic sites. Seven patients received either trigeminal and/or sphenopalatine ganglion stimulation with or without peripheral nerve stimulation, having failed multiple alternative modalities of treatment. The treatments were tailored on the physical location of pain to ensure regional coverage with the stimulation. RESULTS: Fluoroscopy or frameless stereotaxy was utilized to place the sphenopalatine and/or trigeminal ganglion stimulator. All patients were initially trialed before implantation. Trial leads implanted in the pterygopalatine fossa near the sphenopalatine ganglion were implanted via transpterygoid (lateral-medial, infrazygomatic) approach. Trial leads were implanted in the trigeminal ganglion via percutaneous Hartel approach, all of which resulted in masseter contraction. Patients who developed clinically significant pain improvement underwent implantation. The trigeminal ganglion stimulation permanent implants involved placing a grid electrode over Meckel's cave via subtemporal craniotomy, which offered a greater ability to stimulate subdivisions of the trigeminal nerve, without muscular (V3) side effects. Two of the seven overall patients did not respond well to the trial and were not implanted. Five patients reported pain relief with up to 24-month follow-up. Several of the sphenopalatine ganglion stimulation patients had pain relief without any paresthesias. There were no electrode migrations or post-surgical complications. CONCLUSIONS: Refractory facial pain may respond positively to ganglionic forms of stimulation. It appears safe and durable to implant electrodes in the pterygopalatine fossa via a lateral transpterygoid approach. Also, implantation of an electrode grid overlying Meckel's cave appears to be a feasible alternative to the Hartel approach. Further investigation is needed to evaluate the usefulness of these approaches for various facial pain conditions.


Subject(s)
Electric Stimulation Therapy/methods , Facial Pain/therapy , Ganglia, Parasympathetic , Pain, Intractable/therapy , Trigeminal Ganglion , Adult , Aged , Electrodes, Implanted , Facial Pain/etiology , Facial Pain/surgery , Female , Ganglia, Parasympathetic/surgery , Humans , Male , Middle Aged , Neuralgia/etiology , Neuralgia/therapy , Pain, Intractable/surgery , Retrospective Studies , Sinusitis/complications , Tomography, X-Ray Computed , Treatment Outcome , Trigeminal Ganglion/surgery
6.
Perm J ; 17(4): 47-51, 2013.
Article in English | MEDLINE | ID: mdl-24361021

ABSTRACT

Deep brain stimulation is a rapidly expanding therapy initially designed for the treatment of movement disorders and pain syndromes. The therapy includes implantation of electrodes in specific targets of the brain, delivering programmable small and safe electric impulses, like a pacemaker, that modulates both local and broad neurologic networks. The effects are thought to primarily involve a focus in the brain, probably inhibitory, which then restores a network of neural circuitry. Psychiatric diseases can be refractory and severe, leading to high medical costs, significant morbidity, and even death. Whereas surgery for psychiatric disease used to include destructive procedures, deep brain stimulation allows safe, reversible, and adjustable treatment that can be tailored for each patient. Deep brain stimulation offers new hope for these unfortunate patients, and the preliminary results are promising.


Subject(s)
Brain , Deep Brain Stimulation , Obsessive-Compulsive Disorder/therapy , Electrodes, Implanted , Humans , Nerve Net
SELECTION OF CITATIONS
SEARCH DETAIL
...