Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Neurol Neurosurg Psychiatry ; 74(8): 1133-5, 2003 Aug.
Article in English | MEDLINE | ID: mdl-12876253

ABSTRACT

OBJECTIVE: To investigate the incidence and severity of pituitary insufficiency after aneurysmal subarachnoid haemorrhage. METHODS: Pituitary function was tested in a series of patients more than 12 months but less than 60 months after aneurysmal subarachnoid haemorrhage using a combined TRH-LHRH-arginine test and the insulin tolerance test, to elucidate possible deficits in the gonadotrophic, somatotrophic, thyreotrophic, and corticotrophic hormonal axes. RESULTS: Of 21 patients screened, nine (43%) showed deficiencies of at least one pituitary hormone axis. Four patients had corticotrophin deficiency, one had partial growth hormone deficiency, two had severe growth hormone deficiency, and two had severe growth hormone deficiency plus corticotrophin deficiency. CONCLUSIONS: Persistent pituitary dysfunction may be more common after aneurysmal subarachnoid haemorrhage than has so far been recognised and warrants further investigation, given the possibility that some health and neurobehavioural problems in these patients could result from hormone deficiency.


Subject(s)
Hypopituitarism/etiology , Intracranial Aneurysm/surgery , Postoperative Complications/etiology , Subarachnoid Hemorrhage/surgery , Adrenocorticotropic Hormone/deficiency , Adult , Female , Follow-Up Studies , Human Growth Hormone/deficiency , Humans , Hypopituitarism/diagnosis , Male , Middle Aged , Pituitary Function Tests , Postoperative Complications/diagnosis
3.
J Interv Cardiol ; 14(3): 309-12, 2001 Jun.
Article in English | MEDLINE | ID: mdl-12053389

ABSTRACT

Devices used in interventional cardiology are permanent implants. However, most of the devices fulfill only a temporary function. For example, atrial septal defect (ASD) occluders serve as mechanical shields until complete in- and overgrowth of the occluding device by endogenous tissue from the defect edges has occurred. Thereafter, the foreign body material of the devices is no longer needed and bears potential long-term adverse effects. The concept of "biodegradable" occluder devices that act as transient mechanical shields to close the defects and as scaffolds for overgrowth with autologous tissue is, therefore, tempting. Since rapid and complete ingrowth as well as coverage by firm tissue is a prerequisite for any such "biological" occluder devices, the feasibility and short-term in vivo response to STARFlex devices preceeded with autologous cells was studied in an experimental sheep model. The experiments demonstrated that autologous cell preceeding of cardiovascular implants is technically feasible. Cells survived the mechanical stress of device implantation. A precoating of conventional STARFlex occluders led to an increased cellular density after cell seeding of the device, an increased resistance of the precultured cytolayer against mechanical stress, and a significantly higher poststress viability of "implanted" cells. Experimental closure of ASD using autologous-cell preseeded STARFlex devices was uncomplicated. In the sheep model this led to rapid, complete, and firm ingrowth of the device into the adjacent atrial tissue. A thicker layer of young fibrous granulation tissue in organization was found on the preceeded devices compared with the unseeded control group after 4 weeks in vivo. Currently, an increased thrombogenicity limits in vivo application.


Subject(s)
Cell Transplantation , Embolization, Therapeutic/instrumentation , Heart Septal Defects, Atrial/therapy , Humans , Transplantation, Autologous
SELECTION OF CITATIONS
SEARCH DETAIL
...