Results 1 - 20 de 25
Filter
1.
Phys Med Biol ; 69(11)2024 May 21.
Article in English | MEDLINE | ID: mdl-38648795

ABSTRACT

Objective. Photon-counting detector (PCD) CT enables routine virtual-monoenergetic image (VMI) reconstruction. We evaluated the performance of an automatic VMI energy level (keV) selection tool on a clinical PCD-CT system in comparison to an automatic tube potential (kV) selection tool from an energy-integrating-detector (EID) CT system from the same manufacturer.Approach.Four torso-shaped phantoms (20-50 cm width) containing iodine (2, 5, and 10 mg cc-1) and calcium (100 mg cc-1) were scanned on PCD-CT and EID-CT. Dose optimization techniques, task-based VMI energy level and tube-potential selection on PCD-CT (CARE keV) and task-based tube potential selection on EID-CT (CARE kV), were enabled. CT numbers, image noise, and dose-normalized contrast-to-noise ratio (CNRd) were compared.Main results. PCD-CT produced task-specific VMIs at 70, 65, 60, and 55 keV for non-contrast, bone, soft tissue with contrast, and vascular settings, respectively. A 120 kV tube potential was automatically selected on PCD-CT for all scans. In comparison, EID-CT used x-ray tube potentials from 80 to 150 kV based on imaging task and phantom size. PCD-CT achieved consistent dose reduction at 9%, 21% and 39% for bone, soft tissue with contrast, and vascular tasks relative to the non-contrast task, independent of phantom size. On EID-CT, dose reduction factor for contrast tasks relative to the non-contrast task ranged from a 65% decrease (vascular task, 70 kV, 20 cm phantom) to a 21% increase (soft tissue with contrast task, 150 kV, 50 cm phantom) due to size-specific tube potential adaptation. PCD-CT CNRdwas equivalent to or higher than those of EID-CT for all tasks and phantom sizes, except for the vascular task with 20 cm phantom, where 70 kV EID-CT CNRdoutperformed 55 keV PCD-CT images.Significance. PCD-CT produced more consistent CT numbers compared to EID-CT due to standardized VMI output, which greatly benefits standardization efforts and facilitates radiation dose reduction.


Subject(s)
Image Processing, Computer-Assisted , Phantoms, Imaging , Photons , Radiation Dosage , Tomography, X-Ray Computed , Tomography, X-Ray Computed/instrumentation , Image Processing, Computer-Assisted/methods , Automation , Humans , Signal-To-Noise Ratio
2.
J Comput Assist Tomogr ; 48(1): 104-109, 2024.
Article in English | MEDLINE | ID: mdl-37566794

ABSTRACT

OBJECTIVE: Pulse pileup effects occur when pulses occur so close together that they fall on top of one another, resulting in count loss and errors in energy thresholding. To date, there has been little work systematically detailing the quantitative effects of pulse pileup on material decomposition accuracy for photon-counting detector (PCD) computed tomography (CT). Our aim in this work was to quantify the effects of pulse pileup on single-energy and multienergy CT images, including low-energy bin (BL), high-energy bin (BH), iodine map, and virtual noncontrast images from a commercial PCD-CT. METHODS: Scans of a 20-cm diameter multienergy CT phantom with 10 solid inserts were acquired at a fixed tube potential as the tube current was varied across the available range. Four types of images (BL, BH, iodine map, and virtual noncontrast) were reconstructed using an iterative reconstruction algorithm at strength 2, a quantitative reconstruction kernel (Qr40), 2-/1-mm slice thickness/increment, and a 210-mm field-of-view. The mean and standard deviation of CT numbers were recorded and the ratios of CT number between BL and BH images were calculated and plotted, along with noise versus tube current and noise × versus tube current. RESULTS: As tube current was increased, the range of variations in CT numbers was less than 13.4 HU for all inserts and image types evaluated. Noise × versus tube current showed a small positive slope equal to a noise increase from 100 mA of 10% at 500 mA and 15% at 900 mA compared with what would be expected if the slope was zero. CONCLUSIONS: Minimal impact on single-energy and multienergy CT numbers and noise performance was observed for the evaluated clinical PCD-CT system.


Subject(s)
Iodine , Photons , Humans , Tomography, X-Ray Computed/methods , Phantoms, Imaging , Algorithms
3.
Article in English | MEDLINE | ID: mdl-37528865

ABSTRACT

The purpose of this work is to evaluate the low-contrast detectability on a clinical whole-body photon-counting-detector (PCD)-CT scanner and compare it with an energy-integrating-detector (EID) CT scanner, using an efficient Channelized Hotelling observer (CHO)-based method previously developed and optimized on the American College of Radiology (ACR) CT accreditation phantom for routine quality control (QC) purpose. The low-contrast module of an ACR CT phantom was scanned on both the PCD-CT and EID-CT scanners, each with 10 different positionings. For PCD-CT, data were acquired at 120 kV with two major scan modes, standard resolution (SR) (collimation: 144×0.4 mm) and ultra-high-resolution (UHR) (120×0.2 mm). Images were reconstructed with two major modes: virtual monochromatic energy at 70 keV and low-energy threshold (T3D), each with filtered-backprojection (Br44) and iterative reconstruction (Br44-3) kernels. For each positioning, 3 repeated scans were acquired for each scan mode at a fixed radiation dose setting (CTDIvol = 12 mGy). For EID-CT, scans (10 positionings × 3 repeated scans) were performed at a matched CTDIvol, and images were reconstructed using the same kernels with FBP and IR. A recently developed CHO-based method dedicated for QC of low-contrast performance on the ACR phantom was applied to calculate the low-contrast detectability (d') for each scan and reconstruction condition. Results showed that there was no significant difference in low-contrast detectability (d') between the UHR mode and SR mode (p = 0.360-0.942), and the T3D reconstruction resulted in 7.7%-14.6% higher d' than 70keV (p < 0.0016). Similar detectability levels were observed on PCD-CT and EID-CT. The PCD-CT: UHR-T3D had 6.2% higher d' than EID-CT with IR (p = 0.047) and 4.1% lower d' without IR (p = 0.122).

4.
J Appl Clin Med Phys ; 24(7): e14074, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37335819

ABSTRACT

PURPOSE: To determine the suitability of a quality assurance (QA) program based on the American College of Radiology's (ACR) CT quality control (QC) manual to fully evaluate the unique capabilities of a clinical photon-counting-detector (PCD) CT system. METHODS: A daily QA program was established to evaluate CT number accuracy and artifacts for both standard and ultra-high-resolution (UHR) scan modes. A complete system performance evaluation was conducted in accordance with the ACR CT QC manual by scanning the CT Accreditation Phantom with routine clinical protocols and reconstructing low-energy-threshold (T3D) and virtual monoenergetic images (VMIs) between 40 and 120 keV. Spatial resolution was evaluated by computing the modulation transfer function (MTF) for the UHR mode, and multi-energy performance was evaluated by scanning a body phantom containing four iodine inserts with concentrations between 2 and 15 mg I/cc. RESULTS: The daily QA program identified instances when the detector needed recalibration or replacement. CT number accuracy was impacted by image type: CT numbers at 70 keV VMI were within the acceptable range (defined for 120 kV). Other keV VMIs and the T3D reconstruction had at least one insert with CT number outside the acceptable range. The limiting resolution was nearly 40 lp/cm based on MTF measurements, which far exceeds the 12 lp/cm maximum capability of the ACR phantom. The CT numbers in the iodine inserts were accurate on all VMIs (3.8% average percentage error), while the iodine concentrations had an average root mean squared error of 0.3 mg I/cc. CONCLUSION: Protocols and parameters must be properly selected on PCD-CT to meet current accreditation requirements with the ACR CT phantom. Use of the 70 keV VMI allowed passing all tests prescribed in the ACR CT manual. Additional evaluations such an MTF measurement and multi-energy phantom scans are also recommended to comprehensively evaluate PCD-CT scanner performance.


Subject(s)
Iodine , Tomography, X-Ray Computed , Humans , Tomography, X-Ray Computed/methods , Phantoms, Imaging , Photons , Clinical Protocols
5.
J Appl Clin Med Phys ; 22(2): 194-202, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33338314

ABSTRACT

It is important to employ radiation dose reduction techniques in pediatric computed tomography (CT) to reduce potential risks of radiation-induced malignancy. Automatic tube potential (kV) selection tools have been developed and become available on many CT scanners, which select the optimum kV based on the patient size and clinical task to improve the radiation dose efficiency. However, its use in pediatric CT has been mostly empirical, following manufacturer's default recommendation without solid demonstration for quality improvement. This study aimed to implement an automatic tube potential tool (CAREkV, Siemens Healthcare) into routine pediatric CT practice, using the "Plan-Do-Study-Act" quality improvement process, in place of an existing kV/mAs technique chart. The design of this quality improvement project involved Plan-Do-Study-Act stages. Plan and Do stages identified the criteria for optimal automatic kV selection; a range of phantoms representing typical pediatric groups were scanned on a dual-source 128-slice scanner using a fast-pitch scanning mode. The identified CAREkV settings were implemented into the CT protocol and evaluated after a 6-month period. In the Study stage, an objective evaluation of the image metrics and radiation dose for two similar patient cohorts using CAREkV and the technique-chart, respectively, were compared. The kV selected, image quality and radiation dose determined by CAREkV were comparable to those obtained while using the technique-chart. The CAREkV was successfully implemented into our pediatric abdominopelvic CT practice. By utilizing the "PDSA" process optimal image quality and radiation dose reduction were achieved with an automatic kV selection tool to improve CT workflow.


Subject(s)
Tomography, X-Ray Computed , Child , Humans , Phantoms, Imaging , Radiation Dosage , Tomography Scanners, X-Ray Computed , Workflow
6.
Med Phys ; 48(3): 1307-1314, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33332626

ABSTRACT

PURPOSE: To determine the accuracy of CT number and calcium score of a kV-independent technique based on an artificial 120 kV reconstruction, and its potential to reduce radiation dose. METHODS: Anthropomorphic chest phantoms were scanned on a third-generation dual-source CT system equipped with the artificial 120 kV reconstruction. First, a phantom module containing a 20-mm diameter hydroxyapatite (HA) insert was scanned inside the chest phantoms at different tube potentials (70-140 kV) to evaluate calcium CT number accuracy. Next, three small HA inserts (diameter/length = 5 mm) were inserted into a pork steak and scanned inside the phantoms to evaluate calcium score accuracy at different kVs. Finally, the same setup was scanned using automatic exposure control (AEC) at 120 kV, and then with automatic kV selection (auto-kV). Phantoms were also scanned at 120 kV using a size-dependent mA chart. CT numbers of soft tissue and calcium were measured from different kV images. Calcium score of each small HA insert was measured using commercial software. RESULTS: The CT number difference from 120 kV was small with tube potentials from 90 to 140 kV for both soft tissue and calcium (maximal difference of 4/5 HU, respectively). Consistent calcium scores were obtained from images of different kVs compared to 120 kV, with a relative difference <8%. Auto-kV provided a 25-34% dose reduction compared to AEC alone. CONCLUSION: A kV-independent calcium scoring technique can produce artificial 120 kV images with consistent soft tissue and calcium CT numbers compared to standard 120 kV examinations. When coupled with auto-kV, this technique can reduce radiation by 25-34% compared to that with AEC alone, while providing consistent calcium scores as that of standard 120 kV examinations.


Subject(s)
Calcium , Coronary Artery Disease , Drug Tapering , Humans , Phantoms, Imaging , Radiation Dosage , Tomography, X-Ray Computed
7.
Med Phys ; 46(12): 5538-5543, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31580485

ABSTRACT

PURPOSE: The aim of this study was to demonstrate that a low helical pitch causes increased photon starvation artifacts at ultra-low-dose CT. METHODS: A cylindrical water phantom with a diameter of 30 cm was scanned on two different generation CT scanners: a 64-slice scanner (Sensation 64, Siemens Healthcare) and a 192-slice scanner (Somatom Force, Siemens Healthcare) at multiple effective mAs levels (mAs/pitch = 200, 100, 50, 25, and 12). The corresponding CTDIvol values were 4.1, 2.0, 1.0, 0.5 mGy, on the 64-slice scanner and 3.8, 1.9, 1.0, 0.5 mGy on the 192-slice scanner, for the selected effective mAs values. For each dose setting, the scan was repeated at four helical pitches: 1.2, 0.9, 0.6, and the lowest achievable pitch on each scanner. The tube current was automatically adjusted by the scanner so that the effective mAs, and thus CTDIvol , were kept the same for different pitches. All CT data sets were reconstructed with a slice thickness of 3mm and a medium smooth kernel. Images acquired at the same dose level but different helical pitches were visually inspected to assess photon starvation artifacts and noise levels. RESULTS: At the same radiation dose, image noise increased with the decreasing helical pitch. The increase was more severe on the old-generation 64-slice scanner. Photon starvation artifacts were evident at 200 effective mAs on the 64-slice scanner at 80 kV. On the 192-slice scanner there was no visible photon starvation artifacts at both 200 and 50 effective mAs (CTDIvol  = 4.1 mGy and 1.0 mGy, respectively); nor was there a visible impact from the lower helical pitch. Only when the dose was lowered to be extremely low (~0.26 mGy, achievable at 70 kV), did photon starvation artifacts become evident. CONCLUSIONS: A low helical pitch may increase image noise and photon starvation artifacts compared to a higher pitch for the same dose level, particularly at ultra-low dose CT.


Subject(s)
Artifacts , Photons , Radiation Dosage , Tomography, X-Ray Computed , Phantoms, Imaging
8.
Radiographics ; 39(3): 729-743, 2019.
Article in English | MEDLINE | ID: mdl-31059394

ABSTRACT

Photon-counting detector (PCD) CT is an emerging technology that has shown tremendous progress in the last decade. Various types of PCD CT systems have been developed to investigate the benefits of this technology, which include reduced electronic noise, increased contrast-to-noise ratio with iodinated contrast material and radiation dose efficiency, reduced beam-hardening and metal artifacts, extremely high spatial resolution (33 line pairs per centimeter), simultaneous multienergy data acquisition, and the ability to image with and differentiate among multiple CT contrast agents. PCD technology is described and compared with conventional CT detector technology. With the use of a whole-body research PCD CT system as an example, PCD technology and its use for in vivo high-spatial-resolution multienergy CT imaging is discussed. The potential clinical applications, diagnostic benefits, and challenges associated with this technology are then discussed, and examples with phantom, animal, and patient studies are provided. ©RSNA, 2019.


Subject(s)
Photons , Tomography, X-Ray Computed/methods , Animals , Contrast Media , Equipment Design , Humans , Iodine Compounds , Radiation Dosage , Signal-To-Noise Ratio , Tomography, X-Ray Computed/instrumentation , Tomography, X-Ray Computed/trends
9.
AJR Am J Roentgenol ; 212(1): 151-156, 2019 01.
Article in English | MEDLINE | ID: mdl-30422712

ABSTRACT

OBJECTIVE: The purpose of this study was to quantify the dose reduction resulting from the use of lead aprons for pediatric chest CT as a function of the distance between the apron and the bottom of the scan range. MATERIALS AND METHODS: Semianthropomorphic phantoms of the head, abdomen, and pelvis were placed adjacent to a chest phantom to mimic the habitus of a 5-year-old child. A chest CT scan was performed, and a point dosimeter was used to measure the radiation dose at points within and outside the scan range. A lead apron was placed 1, 5, and 10 cm from the bottom of the CT scan range, and the measurements were repeated. The weighted-average dose was calculated for each measurement position. RESULTS: The weighted-average dose within and outside the scan range was 1.7 and 0.067 mGy, respectively. The mean (percentage) dose reduction outside the scan range resulting from use of the lead apron was 0.013 mGy (19.1%), 0.007 mGy (10.1%), and 0.003 mGy (4.3%) when the lead apron was placed at distances of 1, 5, and 10 cm from the bottom of the scan range, respectively. The corresponding total percentage dose reduction (including the dose from the primary scan) was 0.7%, 0.4%, and 0.2%, respectively. CONCLUSION: As the lead apron was placed farther from the scan range, the amount of dose reduction diminished. The reduction in dose was extremely small compared with the overall dose from the examination. The small dose reduction gained from the use of lead shielding over the abdomen and pelvis during chest CT examination of pediatric patients may not outweigh the associated potential risks of artifacts and infection.


Subject(s)
Protective Devices , Radiation Protection/instrumentation , Radiography, Thoracic , Tomography, X-Ray Computed , Child, Preschool , Female , Humans , Lead , Male , Organs at Risk , Phantoms, Imaging , Radiation Dosage , Risk Factors
10.
Article in English | MEDLINE | ID: mdl-30034081

ABSTRACT

The purpose of this study is to determine the optimal iodine contrast-to-noise ratio (CNR) achievable for different patient sizes using virtual-monoenergetic-images (VMIs) and a universal acquisition protocol on photon-counting-detector CT (PCD-CT), and to compare results to those from single-energy (SE) and dual-source-dual-energy (DSDE) CT. Vials containing 3 concentrations of iodine were placed in torso-shaped water phantoms of 5 sizes and scanned on a 2nd generation DSDE scanner with both SE and DE modes. Tube current was automatically adjusted based on phantom size with CTDIvol ranging from 5.1 to 22.3 mGy. PCD-CT scans were performed at 140 kV, 25 and 75 keV thresholds, with CTDIvol matched to the SE scans. DE VMIs were created and CNR was calculated for SE images and DE VMIs. The optimal kV (SE) or keV (DE VMI) was chosen at the point of highest CNR with no noticeable artifacts. For 10 mgI/cc vials in the 35 cm phantom, the optimal CNR of VMIs on PCD (22.6@50keV) was comparable to that of the best DSDE protocol (23.9@50keV) and was higher than that of the best SE protocol (19.7@80kV). In general, the difference of optimal CNR between PCD and SE increased with phantom size, with PCD 50 keV VMIs having an equivalent CNR (0.6% difference) with that of SE at the 25 cm phantom and 57% higher CNR at the 45 cm phantom. PCD-CT demonstrated comparable iodine CNR of VMIs to that of DSDE across patient sizes. Whereas SE and DSDE CT exams require use of patient-size-specific acquisitions settings, our findings point to the ability of PCD-CT to simplify protocol selection, using a single VMI keV setting (50 keV), acquisition kV (140 kV), and energy thresholds (25 and 75 keV) for all patient sizes, while achieving optimal or near optimal iodine CNR values.

11.
J Appl Clin Med Phys ; 19(4): 252-260, 2018 Jul.
Article in English | MEDLINE | ID: mdl-29749048

ABSTRACT

OBJECTIVES: Both projection and dual-energy (DE)-based methods have been used for metal artifact reduction (MAR) in CT. The two methods can also be combined. The purpose of this work was to evaluate these three MAR methods using phantom experiments for five types of metal implants. MATERIALS AND METHODS: Five phantoms representing spine, dental, hip, shoulder, and knee were constructed with metal implants. These phantoms were scanned using both single-energy (SE) and DE protocols with matched radiation output. The SE data were processed using a projection-based MAR (iMAR, Siemens) algorithm, while the DE data were processed to generate virtual monochromatic images at high keV (Mono+, Siemens). In addition, the DE images after iMAR were used to generate Mono+ images (DE iMAR Mono+). Artifacts were quantitatively evaluated using CT numbers at different regions of interest. Iodine contrast-to-noise ratio (CNR) was evaluated in the spine phantom. Three musculoskeletal radiologists and two neuro-radiologists independently ranked the artifact reduction. RESULTS: The DE Mono+ at high keV resulted in reduced artifacts but also lower iodine CNR. The iMAR method alone caused missing tissue artifacts in dental phantom. DE iMAR Mono+ caused wrong CT numbers in close proximity to the metal prostheses in knee and hip phantoms. All musculoskeletal radiologists ranked SE iMAR > DE iMAR Mono+ > DE Mono+ for knee and hip, while DE iMAR Mono+ > SE iMAR > DE Mono+ for shoulder. Both neuro-radiologists ranked DE iMAR Mono+ > DE Mono+ > SE iMAR for spine and DE Mono+ > DE iMAR Mono+ > SE iMAR for dental. CONCLUSIONS: The SE iMAR was the best choice for the hip and knee prostheses, while DE Mono+ at high keV was best for dental implants and DE iMAR Mono+ was best for spine and shoulder prostheses. Artifacts were also introduced by MAR algorithms.


Subject(s)
Artifacts , Algorithms , Humans , Metals , Phantoms, Imaging , Tomography, X-Ray Computed
12.
Otol Neurotol ; 38(7): 978-984, 2017 08.
Article in English | MEDLINE | ID: mdl-28570418

ABSTRACT

HYPOTHESIS: A new generation 192-slice multi-detector computed tomography (MDCT) clinical scanner provides enhanced image quality and superior electrode localization over conventional MDCT. BACKGROUND: Currently, accurate and reliable cochlear implant electrode localization using conventional MDCT scanners remains elusive. METHODS: Eight fresh-frozen cadaveric temporal bones were implanted with full-length cochlear implant electrodes. Specimens were subsequently scanned with conventional 64-slice and new generation 192-slice MDCT scanners utilizing ultra-high resolution modes. Additionally, all specimens were scanned with micro-CT to provide a reference criterion for electrode position. Images were reconstructed according to routine temporal bone clinical protocols. Three neuroradiologists, blinded to scanner type, reviewed images independently to assess resolution of individual electrodes, scalar localization, and severity of image artifact. RESULTS: Serving as the reference standard, micro-CT identified scalar crossover in one specimen; imaging of all remaining cochleae demonstrated complete scala tympani insertions. The 192-slice MDCT scanner exhibited improved resolution of individual electrodes (p < 0.01), superior scalar localization (p < 0.01), and reduced blooming artifact (p < 0.05), compared with conventional 64-slice MDCT. There was no significant difference between platforms when comparing streak or ring artifact. CONCLUSION: The new generation 192-slice MDCT scanner offers several notable advantages for cochlear implant imaging compared with conventional MDCT. This technology provides important feedback regarding electrode position and course, which may help in future optimization of surgical technique and electrode design.


Subject(s)
Cochlea/surgery , Cochlear Implantation/methods , Cochlear Implants , Temporal Bone/surgery , Cochlea/diagnostic imaging , Electrodes, Implanted , Humans , Radionuclide Imaging , Temporal Bone/diagnostic imaging , Tomography, X-Ray Computed/methods
13.
Med Phys ; 43(12): 6413, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27908191

ABSTRACT

PURPOSE: This study aimed to investigate the influence of display window setting on technologist performance detecting subtle but clinically relevant artifacts in daily computed tomography (CT) quality control (dQC) images. METHODS: Fifty three sets of dQC images were retrospectively selected, including 30 sets without artifacts, and 23 with subtle but clinically relevant artifacts. They were randomized and shown to six CT technologists (two new and four experienced). Each technologist reviewed all images in each of two sessions, one with a display window width (WW) of 100 HU, which is currently recommended by the American College of Radiology, and the other with a narrow WW of 40 HU, both at a window level of 0 HU. For each case, technologists rated the presence of image artifacts based on a five point scale. The area under the receiver operating characteristic curve (AUC) was used to evaluate the artifact detection performance. RESULTS: At a WW of 100 HU, the AUC (95% confidence interval) was 0.658 (0.576, 0.740), 0.532 (0.429, 0.635), and 0.616 (0.543, 0.619) for the experienced, new, and all technologists, respectively. At a WW of 40 HU, the AUC was 0.768 (0.687, 0.850), 0.546 (0.433, 0.658), and 0.694 (0.619, 0.769), respectively. The performance significantly improved at WW of 40 HU for experienced technologists (p = 0.009) and for all technologists (p = 0.040). CONCLUSIONS: Use of a narrow display WW significantly improved technologists' performance in dQC for detecting subtle but clinically relevant artifacts as compared to that using a 100 HU display WW.


Subject(s)
Artifacts , Quality Assurance, Health Care , Tomography, X-Ray Computed/standards , Humans
14.
Phys Med Biol ; 60(21): 8381-97, 2015 Nov 07.
Article in English | MEDLINE | ID: mdl-26459751

ABSTRACT

Through this investigation we developed a methodology to evaluate and standardize CT image quality from routine abdomen protocols across different manufacturers and models. The influence of manufacturer-specific automated exposure control systems on image quality was directly assessed to standardize performance across a range of patient sizes. We evaluated 16 CT scanners across our health system, including Siemens, GE, and Toshiba models. Using each practice's routine abdomen protocol, we measured spatial resolution, image noise, and scanner radiation output (CTDIvol). Axial and in-plane spatial resolutions were assessed through slice sensitivity profile (SSP) and modulation transfer function (MTF) measurements, respectively. Image noise and CTDIvol values were obtained for three different phantom sizes. SSP measurements demonstrated a bimodal distribution in slice widths: an average of 6.2 ± 0.2 mm using GE's 'Plus' mode reconstruction setting and 5.0 ± 0.1 mm for all other scanners. MTF curves were similar for all scanners. Average spatial frequencies at 50%, 10%, and 2% MTF values were 3.24 ± 0.37, 6.20 ± 0.34, and 7.84 ± 0.70 lp cm(-1), respectively. For all phantom sizes, image noise and CTDIvol varied considerably: 6.5-13.3 HU (noise) and 4.8-13.3 mGy (CTDIvol) for the smallest phantom; 9.1-18.4 HU and 9.3-28.8 mGy for the medium phantom; and 7.8-23.4 HU and 16.0-48.1 mGy for the largest phantom. Using these measurements and benchmark SSP, MTF, and image noise targets, CT image quality can be standardized across a range of patient sizes.


Subject(s)
Radiography, Abdominal/standards , Tomography Scanners, X-Ray Computed/standards , Tomography, X-Ray Computed/standards , Radiography, Abdominal/instrumentation , Radiography, Abdominal/methods , Tomography, X-Ray Computed/instrumentation , Tomography, X-Ray Computed/methods
15.
Radiographics ; 34(4): 849-62, 2014.
Article in English | MEDLINE | ID: mdl-25019428

ABSTRACT

Most noise reduction methods involve nonlinear processes, and objective evaluation of image quality can be challenging, since image noise cannot be fully characterized on the sole basis of the noise level at computed tomography (CT). Noise spatial correlation (or noise texture) is closely related to the detection and characterization of low-contrast objects and may be quantified by analyzing the noise power spectrum. High-contrast spatial resolution can be measured using the modulation transfer function and section sensitivity profile and is generally unaffected by noise reduction. Detectability of low-contrast lesions can be evaluated subjectively at varying dose levels using phantoms containing low-contrast objects. Clinical applications with inherent high-contrast abnormalities (eg, CT for renal calculi, CT enterography) permit larger dose reductions with denoising techniques. In low-contrast tasks such as detection of metastases in solid organs, dose reduction is substantially more limited by loss of lesion conspicuity due to loss of low-contrast spatial resolution and coarsening of noise texture. Existing noise reduction strategies for dose reduction have a substantial impact on lowering the radiation dose at CT. To preserve the diagnostic benefit of CT examination, thoughtful utilization of these strategies must be based on the inherent lesion-to-background contrast and the anatomy of interest. The authors provide an overview of existing noise reduction strategies for low-dose abdominopelvic CT, including analytic reconstruction, image and projection space denoising, and iterative reconstruction; review qualitative and quantitative tools for evaluating these strategies; and discuss the strengths and limitations of individual noise reduction methods.


Subject(s)
Artifacts , Pelvis/diagnostic imaging , Radiography, Abdominal/methods , Tomography, X-Ray Computed/methods , Humans , Image Processing, Computer-Assisted/methods , Radiation Dosage
16.
Radiographics ; 31(3): 835-48, 2011.
Article in English | MEDLINE | ID: mdl-21571660

ABSTRACT

In addition to existing strategies for reducing radiation dose in computed tomographic (CT) examinations, such as the use of automatic exposure control, use of the optimal tube potential also may help improve image quality or reduce radiation dose in pediatric CT examinations. The main benefit of the use of a lower tube potential is that it provides improved contrast enhancement, a characteristic that may compensate for the increase in noise that often occurs at lower tube potentials and that may allow radiation dose to be substantially reduced. However, selecting an appropriate tube potential and determining how much to reduce radiation dose depend on the patient's size and the diagnostic task being performed. The power limits of the CT scanner and the desired scanning speed also must be considered. The use of a lower tube potential and the amount by which to reduce radiation dose must be carefully evaluated for each type of examination to achieve an optimal tradeoff between contrast, noise, artifacts, and scanning speed.


Subject(s)
Radiation Dosage , Radiation Protection/methods , Tomography, X-Ray Computed/instrumentation , Artifacts , Contrast Media , Humans , Phantoms, Imaging , Tomography, X-Ray Computed/methods
17.
AJR Am J Roentgenol ; 194(2): W193-201, 2010 Feb.
Article in English | MEDLINE | ID: mdl-20093573

ABSTRACT

OBJECTIVE: The purpose of our study was to evaluate the dose and image quality performance of a dedicated cone-beam CT (CBCT) scanner in comparison with an MDCT scanner. MATERIALS AND METHODS: The conventional dose metric, CT dose index (CTDI), is no longer applicable to CBCT scanners. We propose to use two dose metrics, the volume average dose and the mid plane average dose, to quantify the dose performance in a circular cone-beam scan. Under the condition of equal mid plane average dose, we evaluated the image quality of a CBCT scanner and an MDCT scanner, including high-contrast spatial resolution, low-contrast spatial resolution, noise level, CT number uniformity, and CT number accuracy. RESULTS: For the sinus scanning protocol, the CBCT system had comparable high-contrast resolution and inferior low-contrast resolution to those obtained with the MDCT scanner when the doses were matched (mid plane average dose 9.2 mGy). The CT number uniformity and accuracy were worse on the CBCT scanner. The image artifacts caused by beam hardening and scattering were also much more severe on the CBCT system. CONCLUSION: With a matched radiation dose, the CBCT system for sinus study has comparable high-contrast resolution and inferior low-contrast resolution relative to the MDCT scanner. Because of the more severe image artifacts on the CBCT system due to the small field of view and the lack of accurate scatter and beam-hardening correction, the utility of the CBCT system for diagnostic tasks related to soft tissue should be carefully assessed.


Subject(s)
Cone-Beam Computed Tomography/instrumentation , Cone-Beam Computed Tomography/methods , Head , Tomography, X-Ray Computed/instrumentation , Tomography, X-Ray Computed/methods , Humans , Phantoms, Imaging , Radiation Dosage
18.
AJR Am J Roentgenol ; 192(4): 941-8, 2009 Apr.
Article in English | MEDLINE | ID: mdl-19304698

ABSTRACT

OBJECTIVE: The objective of our study was to compare the spatial resolution and effective dose from 64-MDCT with several published CT urography protocols. MATERIALS AND METHODS: A phantom containing 1-, 2-, or 4-mm cylindric channels to simulate ureters with 0.25- to 3-mm plugs to simulate ureteral filling defects or ureteral diverticula was imaged using eight helical CT urography protocols. Computed radiography (CR) was also performed. Coronal maximum-intensity-projection images were created and, with the CR image, were evaluated independently by two genitourinary radiologists. Spatial resolution was evaluated by scoring each abnormality as present, visible; or as absent, not visible. Effective dose estimates for 11 CT urography protocols, including the radiographs obtained in the CT urography protocol, were calculated using published Monte Carlo organ dose coefficients. RESULTS: All ureteral abnormalities detected on CR were detected on the highest-spatial-resolution reconstruction using the evaluated 64-MDCT system. The smallest filling defect identified by both was 0.25 mm. Three 0.25-mm filling defects were not detected using the evaluated 16-MDCT system. The 4-MDCT system protocols showed the poorest performance. The range of effective doses for the evaluated CT urography protocols was 20.1-66.3 mSv. The number of phases, anatomic coverage per phase, and scanning parameters all contributed to this variation in dose. CONCLUSION: The evaluated 64-MDCT system showed detection accuracy identical to that of CR. Limiting anatomic coverage for specific phases and combining phases can reduce dose for multiphase protocols by up to a factor of 2 relative to early (circa 2000) 4-MDCT.


Subject(s)
Tomography, Spiral Computed/methods , Ureter/diagnostic imaging , Urography/methods , Humans , Phantoms, Imaging , Radiation Dosage
19.
J Comput Assist Tomogr ; 32(2): 233-7, 2008.
Article in English | MEDLINE | ID: mdl-18379308

ABSTRACT

OBJECTIVE: To determine the appropriate computed tomographic (CT) image reconstruction algorithms for a quantitative multicenter trial of diffuse lung disease. METHODS: Phantom images were reconstructed using relevant reconstruction algorithms from 2 CT manufacturers to measure mean CT numbers and image noise. High-contrast spatial resolution and edge response function were determined for each algorithm. Clinical images of patients with diffuse lung disease were evaluated by a thoracic radiologist in terms of image quality and disease extent. RESULTS: The CT numbers were accurate for most reconstruction algorithms for both manufacturers, although some algorithms with strong midfrequency enhancement altered CT numbers. The Bone (GE) and B46f (Siemens) algorithms provided the higher spatial resolution deemed clinically necessary for imaging diffuse lung disease while preserving CT number accuracy. The extent of diffuse lung disease was strongly dependent on the reconstruction algorithm. CONCLUSIONS: A moderately sharp reconstruction algorithm (Bone/B46f) was selected for the evaluation of diffuse lung disease.


Subject(s)
Algorithms , Emphysema/diagnosis , Image Processing, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Humans , Lung/diagnostic imaging , Phantoms, Imaging , Reproducibility of Results , Retrospective Studies
20.
Radiographics ; 28(1): 245-53, 2008.
Article in English | MEDLINE | ID: mdl-18203941

ABSTRACT

In x-ray computed tomography (CT), the most common parameter used to estimate and minimize patient dose is the CT dose index (CTDI). The CTDI is a volume-averaged measure that is used in situations where the table is incremented in conjunction with the tube rotation. Variants of the CTDI correct for averaging across the field of view and for adjacent beam overlaps or gaps. CTDI is usually measured with a pencil-shaped ionization chamber, although methods have been developed that use alternative detectors, including an optically stimulated luminescence probe and a solid-state real-time dosimeter. Because the CTDI represents an averaged dose to a homogeneous cylindrical phantom, the measurements are only an approximation of the patient dose. Furthermore, dose from interventional or perfusion CT, in which the table remains stationary between multiple scans, is best evaluated with point dose measurements made with small detectors. CTDI and point dose values are nearly the same for measurement of surface dose from spiral CT. However, for measurement of surface dose from perfusion CT, the dose is overestimated by a factor of two or more with CTDI values in comparison with point dose values. Both CTDI and point dose measurement are valuable for evaluating CT scanner output and estimating patient dose.


Subject(s)
Radiation Monitoring/instrumentation , Radiation Monitoring/methods , Radiation Protection/methods , Tomography, X-Ray Computed/instrumentation , Body Burden , Equipment Design , Equipment Failure Analysis , Humans , Radiation Injuries/prevention & control , Relative Biological Effectiveness , Technology Assessment, Biomedical , Tomography, X-Ray Computed/methods