Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Vasc Surg ; 96: 195-206, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37075835

ABSTRACT

BACKGROUND: To evaluate longer-term results of a cohort treated with primary chimney endovascular aneurysm sealing (ChEVAS) for complex abdominal aortic aneurysms or secondary ChEVAS after failed endovascular aneurysm repair/endovascular aneurysm sealing. METHODS: A single-center study was conducted of 47 consecutive patients (mean age 72 ± 8 years, range 50-91; 38 men) treated with ChEVAS from February 2014 to November 2016 and followed through December 2021. The main outcome measures were all-cause mortality (ACM), aneurysm-related mortality, occurrence of secondary complications and conversion to open surgery. Data are presented as the median (interquartile range [IQR]) and absolute range. RESULTS: 35 patients received a primary ChEVAS (=group I) and 12 patients a secondary ChEVAS (=group II). Technical success was 97% (group I) and 92% (group II); 30-day mortality was 3% and 8%, respectively. The median proximal sealing zone length was 20.5 mm (IQR 16, 24; range 10-48) in group I and 26 mm (IQR 17.5, 30; range 8-45) in group II, respectively. During a median time of follow-up of 62 months (range 0-88), ACM amounted to 60% (group I) and 58% (group II); aneurysm mortality was 29% and 8%, respectively. An endoleak was seen in 57% (group I: 15 type Ia endoleaks, four isolated type Ib, and 1 endoleak type V) and 25% (group II: 1 endoleak type Ia, one type II, and 2 type V), aneurysm growth in 40% and 17%, migration in 40% and 17%, resulting in 20% and 25% conversions in group I and II, respectively. Overall a secondary intervention was performed in 51% (group I) and 25% (group II), respectively. The occurrence of complications did not significantly differ between the 2 groups. Neither the number of chimney grafts, nor the thrombus ratio significantly affected the occurrence of abovementioned complications. CONCLUSIONS: While initially delivering a high technical success rate, ChEVAS fails to provide acceptable longer-term results both in primary and secondary ChEVAS, resulting in high rates of complications, secondary interventions and open conversions.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Male , Humans , Middle Aged , Aged , Aged, 80 and over , Endoleak/diagnostic imaging , Endoleak/etiology , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Follow-Up Studies , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Treatment Outcome
2.
J Endovasc Ther ; 28(2): 332-341, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33236681

ABSTRACT

PURPOSE: To evaluate the technical features and clinical results after open conversion for complications following endovascular aneurysm sealing (EVAS). MATERIALS AND METHODS: From July 2013 to February 2020, 44 patients (mean age 72±8 years; 36 men) underwent an open conversion due to EVAS complications in a single center. Data were collected on patient characteristics, reasons for conversion, characteristics and duration of the procedure, condition of the polymer, blood loss, time in the intensive care unit (ICU), and intra/postoperative complications. The main outcome measure was mortality at 30 days and in follow-up. Data are presented as the median (IQR) and absolute range. RESULTS: On average, the open conversion took place 3 years after the initial EVAS implantation [median 37 months (IQR 23, 50); range 0-64]. Most patients were converted due migration (82%), aneurysm growth (77%), and/or endoleak (75%), with 21 patients (48%) having all 3 events. Less frequent diagnoses were aneurysm rupture (n=7), aortic infection (n=3), technical failure during implantation (n=2), and graft thrombosis (n=1). The majority of patients (n=26) were asymptomatic and converted electively, but 9 were operated on urgently and 9 emergently (7 late rupture and 2 due to technical failure). The median procedure duration was 178 minutes (IQR 149, 223; range 87-417), the median blood loss was 1100 mL (IQR 600, 2600; range 300-5000). Polymer degradation was mentioned in the operative reports of 18 cases (41%). Patients stayed a median of 3 days (IQR 2, 7; range 1-35) in the ICU, while the median length of stay in the hospital was 14 days (IQR 10, 20; range 0-93). The 30-day mortality was 23% (n=10). During a median follow-up of 3 months (IQR 0, 11; range 0-38), no additional deaths occurred, but 12 patients suffered from an adverse event. There were 3 cases of wound dehiscence after laparotomy, 2 cases of leg ischemia, 2 cases of renal failure, and individual cases of urinary obstruction, urinoma, paralytic ileus, gastrointestinal bleeding, and postoperative delirium. A non-elective setting was associated with a significantly increased mortality of 33% in urgent cases and 56% in emergent cases (p=0.007). Based on these results an algorithm for the management of EVAS complications was developed. CONCLUSION: The significantly increased mortality associated with nonelective conversions highlights the need for active surveillance. The presented algorithm offers a structured tool to avoid emergency conversions.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Endovascular Procedures/adverse effects , Female , Humans , Male , Middle Aged , Postoperative Complications/etiology , Retrospective Studies , Stents , Treatment Outcome
3.
J Endovasc Ther ; 25(4): 418-425, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29896999

ABSTRACT

PURPOSE: To evaluate the impact of the revised Nellix instructions for use (IFU) from 2016 on clinical outcomes and anatomic applicability by retrospectively applying them to a cohort treated with endovascular aneurysm sealing according to the original IFU 2013. METHODS: A single-center study was conducted of 100 consecutive patients (mean age 72±8 years, range 46-91; 89 men) treated electively with standard bilateral EVAS from July 2013 to August 2015 and followed through December 2017. Procedures previously classified within and outside the original IFU from 2013 (75 and 25, respectively) were reclassified according to the revised IFU 2016 (34 and 66, respectively). Stepwise backward logistic regression analysis was performed to evaluate the prognostic value of specific anatomic features for the development of endoleak and/or migration. RESULTS: The single most important morphologic feature disqualifying patients from being within IFU 2016 was a thrombus ratio >1.4 (36 of 41 reclassified patients). Overall technical success was 98% (100% within vs 97% outside IFU 2016, p=0.323) and 30-day mortality was 3% (0% within vs 5% outside IFU 2016, p=0.251). During a median follow-up of 31 months (range 0-53), overall mortality was 21% (15% within vs 24% outside IFU 2016, p=0.469); aneurysm-related mortality was 8% (3% within vs 11% outside IFU 2016, p=0.533). Twenty-six patients developed an endoleak (6 within vs 20 outside IFU 2016, p=0.172) and 23 had migration (4 within vs 19 outside IFU 2016, p=0.088). Both proximal neck length <10 mm and neck angulation >60° were positive predictors for the development of endoleak and/or migration. A reintervention was performed in 26 patients (7 within vs 19 outside IFU 2016, p=0.376). While a significant difference was found between the within vs outside IFU 2016 groups with regard to freedom from migration (p=0.026) and the composite freedom from endoleak and/or migration (p=0.021), there were no significant differences in survival (p=0.201) or freedom from reintervention (p=0.505), suggesting a limited effectiveness of the new IFU 2016. CONCLUSION: The IFU 2016 reduced the anatomic applicability to 34% from 75% for the original IFU 2013. The lack of significant intergroup differences in terms of survival and reinterventions suggests a limited effectiveness of the new IFU 2016.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Patient Selection , Stents , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/mortality , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Endoleak/etiology , Endoleak/surgery , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Foreign-Body Migration/etiology , Foreign-Body Migration/surgery , Humans , Male , Middle Aged , Product Labeling , Progression-Free Survival , Prosthesis Design , Reoperation , Retrospective Studies , Risk Factors , Time Factors
4.
Vascular ; 24(4): 339-47, 2016 Aug.
Article in English | MEDLINE | ID: mdl-26486377

ABSTRACT

OBJECTIVE: In the present study, 50 EVAS procedures were evaluated in regard to primary (survival and technical success) and secondary (device-related complications) events of interest. METHODS: The single center study was conducted from July 2013 to August 2014 with prospective collection of the clinical data. The clinical results were controlled by CT angiography and contrast-enhanced ultrasound. RESULTS: The technical success was 98% and the 30-day mortality 4%. One (2%) patient died from multisystem organ failure and another patient from an intracranial bleeding, respectively. One patient (2%) suffered from a device-related aneurysm rupture. During early follow-up, one (2%) patient developed an endoleak type II, while three (6%) patients suffered from a partial endograft limb thrombosis. Overall, a secondary intervention was necessary in six (12%) patients. CONCLUSIONS: With the Nellix EVAS system, a high primary technical success of 98% was achieved; one (2%) patient developed an endoleak type II which did not require secondary intervention. Those promising results are contrasted by a substantial rate of endograft limb thromboses (8%) and one (2%) intraoperative aneurysm rupture. Further studies are needed to assess the durability of the Nellix stentgraft and the occurrence of device-related complications.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Stents , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Aortography/methods , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Computed Tomography Angiography , Endoleak/etiology , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Germany , Graft Occlusion, Vascular/etiology , Humans , Male , Middle Aged , Postoperative Hemorrhage/etiology , Prosthesis Design , Retrospective Studies , Thrombosis/etiology , Time Factors , Treatment Outcome , Ultrasonography
5.
Vascular ; 23(1): 9-16, 2015 Feb.
Article in English | MEDLINE | ID: mdl-24621559

ABSTRACT

OBJECTIVE: Fifty patients with complex aortic disease, who received hybrid treatment of the aortic arch with supra-aortic debranching and endovascular stent-graft repair, were evaluated in regard to events of primary (survival and technical success) and secondary (procedure-related complications) interest. METHODS: The single-center study was conducted over an eight-year period from December 2004 to December 2012. Treated medical conditions included 23 aortic aneurysms (46%), 21 aortic dissections (42%), and six penetrating aortic ulcers (12%). Procedures were divided into groups of elective, urgent, and emergent. RESULTS: Twenty-eight (56%) patients were operated electively, 15 (30%) urgently, and seven (14%) emergently. Sternotomy, cardiopulmonary bypass, and deep hypothermic circulatory arrest were required in 12 (24%) patients. The primary technical success rate was 86% and raised to 92% (n=46) of secondary technical success rate after therapy of three type I endoleaks. The 30-day mortality added up to 16.0%, and the mean time of survival was 49.3 months. In a total of eight (16%) patients, an endoleak occurred (five endoleaks type I, three endoleaks type II), while nine (18%) of patients suffered a perioperative stroke. CONCLUSIONS: In severely ill patients with complex aortic diseases, hybrid therapy may offer a promising alternative to conventional open repair.


Subject(s)
Aorta, Thoracic/surgery , Aortic Diseases/surgery , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Aged , Aorta, Thoracic/diagnostic imaging , Aortic Diseases/diagnosis , Aortic Diseases/mortality , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis Implantation/mortality , Cardiopulmonary Bypass , Circulatory Arrest, Deep Hypothermia Induced , Elective Surgical Procedures , Emergencies , Endoleak/etiology , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Endovascular Procedures/mortality , Female , Germany , Humans , Kaplan-Meier Estimate , Male , Prosthesis Design , Retrospective Studies , Risk Factors , Stents , Sternotomy , Stroke/etiology , Time Factors , Tomography, X-Ray Computed , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...