ABSTRACT
INTRODUCTION: Radiosynovectomy (RS) with 90Y-hydroxyapatite (90Y-HyA) aims to control knee hemarthrosis in hemophiliac patients to prevent secondary arthropathy. However, knee RS using 153Sm-hydroxyapatite (153Sm-HyA) is considered less suitable due to the lower average soft tissue range and energy of 153Sm for large joints, such as the knees. PURPOSE: The objective of this investigation was to assess the efficacy and safety of knee RS with 153Sm-HyA, compared to 90Y-HyA. METHODS: Forty patients were prospectively assigned to undergo knee RS with 153Sm-HyA (n = 19) or with 90Y-HyA (n = 21). The frequency of hemarthrosis episodes before and after treatment were compared. RESULTS: After six months of knee RS, 153Sm-HyA and 90Y-HyA promoted a similar reduction of hemarthrosis episodes (50% and 66.7%, respectively). However, after 12 months of knee RS, the reduction of hemarthrosis episodes was significantly (p = 0.037) higher using 153Sm-HyA (87.5%) compared to 90Y-HyA (50.0%). This discrepancy was more pronounced (p = 0.002) for 153Sm-HyA compared to 90Y-HyA in adults/adolescents. CONCLUSION: Knee radiosynovectomy with 153Sm-HyA is safe, reduces hemarthrosis episodes after 12 months of treatments, especially in adults/adolescents and even with grades III/IV arthropathy, similar to 90Y-HyA. 90Y-HyA seems to promote better hemarthrosis control in small children.