Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Langmuir ; 29(33): 10586-95, 2013 Aug 20.
Article in English | MEDLINE | ID: mdl-23859497

ABSTRACT

Electrodes modified with single-walled carbon nanotubes (SWNTs) offer a number of attractive properties for developing novel electrochemical sensors. A common method to immobilize SWNTs onto the electrode surface is by placing a droplet of a SWNT suspension onto the electrode surface and allowing the solvent to evaporate. In order to maximize the properties of individual SWNTs, surfactants are normally present in these suspensions to provide stable and homogeneous SWNT dispersions. In this study we investigated the effect of different surfactants on the electrochemical and enzymatic performance of SWNT modified glassy carbon electrodes (GCEs). Amperometic biosensors for glucose were fabricated by a two-step procedure. In the first step, SWNT films were deposited onto GCEs by solution casting suspensions of SWNTs in water, Triton X-100, Tween 20, sodium cholate or sodium dodecylbenzenesulfonate (NaDDBS). In the second step, hydrogels containing a redox polymer and the enzyme, glucose oxidase (GOX), were deposited and cross-linked onto the SWNT-modified GCE. Three different redox polymers were tested: 3-ferrocenylpropyl-modified LPEI, (Fc-C3-LPEI), 6-ferrocenylhexyl-modified LPEI, (Fc-C6-LPEI), and poly[(vinylpyridine)Os(bipyridyl)2Cl](2+/3+)(PVP-Os). Biosensors constructed with SWNT films from suspensions of Triton X-100 or Tween 20 generally produced the highest electrochemical and enzymatic responses, with Triton X-100 films producing current densities of ~1.7-2.1 mA/cm(2) for the three different redox polymers. In contrast, biosensors constructed with SWNT films from sodium cholate suspensions resulted in significant decreases in the electrochemical and enzymatic response and in some cases showed no enzymatic activity. The results with SWNT films from NaDDBS suspensions were dependent upon the specific redox polymer used, but in general gave reduced enzymatic responses (~0.05-0.4 mA/cm(2)). These results demonstrate the importance of surfactant type in fabricating SWNT-modified electrode films.


Subject(s)
Electrodes , Nanotubes, Carbon/chemistry , Polymers/chemistry , Surface-Active Agents/chemistry , Oxidation-Reduction
2.
Acta Biomater ; 8(11): 4080-91, 2012 Nov.
Article in English | MEDLINE | ID: mdl-22820307

ABSTRACT

Platelet adhesion to the vessel wall during vascular injury is mediated by platelet glycoproteins binding to their respective ligands on the vascular wall. In this study we investigated the roles that ligand patch spacing and size play in regulating platelet interactions with fibrinogen under hemodynamic flow conditions. To regulate the size and distance between patches of fibrinogen we developed a photolithography-based technique to fabricate patterns of proteins surrounded by a protein-repellant layer of poly(ethylene glycol). We demonstrate that when mepacrine labeled whole blood is perfused at a shear rate of 100 s ⁻¹ over substrates patterned with micron-sized wide lines of fibrinogen, platelets selectively adhere to the areas of patterned fibrinogen. Using fluorescent and scanning electron microscopy we demonstrate that the degree of platelet coverage (3-35%) and the ability of platelet aggregates to grow laterally are dependent upon the distance (6-30 µm) between parallel lines of fibrinogen. We also report on the effects of fibrinogen patch size on platelet adhesion by varying the size of the protein patch (2-20 µm) available for adhesion, demonstrating that the downstream length of the ligand patch is a critical parameter in platelet adhesion under flow. We expect that these results and protein patterning surfaces will be useful in understanding the spatial and temporal dynamics of platelet adhesion under physiologic flow, and in the development of novel platelet adhesion assays.


Subject(s)
Fibrinogen/chemistry , Fibrinogen/pharmacology , Platelet Adhesiveness/drug effects , Platelet Aggregation/drug effects , Rheology/drug effects , Blood Platelets/drug effects , Blood Platelets/ultrastructure , Humans , Stress, Mechanical
3.
Biotechnol Bioeng ; 109(7): 1769-78, 2012 Jul.
Article in English | MEDLINE | ID: mdl-22252687

ABSTRACT

We used a pin-on-disc tribometer to measure the friction coefficient of both pristine and mechanically damaged cartilage samples in the presence of different lubricant solutions. The experimental set up maximizes the lubrication mechanism due to interstitial fluid pressurization. In phosphate buffer solution (PBS), the measured friction coefficient increases with the level of damage. The main result is that when poly(ethylene oxide) (PEO) or hyaluronic acid (HA) are dissolved in PBS, or when synovial fluid (SF) is used as lubricant, the friction coefficients measured for damaged cartilage samples are only slightly larger than those obtained for pristine cartilage samples, indicating that the surface damage is in part alleviated by the presence of the various lubricants. Among the lubricants considered, 100 mg/mL of 100,000 Da MW PEO in PBS appears to be as effective as SF. We attempted to discriminate the lubrication mechanism enhanced by the various compounds. The lubricants viscosity was measured at shear rates comparable to those employed in the friction experiments, and a quartz crystal microbalance with dissipation monitoring was used to study the adsorption of PEO, HA, and SF components on collagen type II adlayers pre-formed on hydroxyapatite. Under the shear rates considered the viscosity of SF is slightly larger than that of PBS, but lower than that of lubricant formulations containing HA or PEO. Neither PEO nor HA showed strong adsorption on collagen adlayers, while evidence of adsorption was found for SF. Combined, these results suggest that synovial fluid is likely to enhance boundary lubrication. It is possible that all three formulations enhance lubrication via the interstitial fluid pressurization mechanism, maximized by the experimental set up adopted in our friction tests.


Subject(s)
Cartilage, Articular/chemistry , Cartilage, Articular/pathology , Friction , Animals , Cartilage, Articular/injuries , Cattle , Hyaluronic Acid/chemistry , Lubricants/chemistry , Lubrication , Polyethylene Glycols/chemistry , Quartz Crystal Microbalance Techniques , Stress, Mechanical , Synovial Fluid/chemistry , Viscosity
4.
Langmuir ; 27(10): 6201-10, 2011 May 17.
Article in English | MEDLINE | ID: mdl-21480616

ABSTRACT

In this study, we describe the effects of incorporating single-walled carbon nanotubes (SWNTs) into redox polymer-enzyme hydrogels. The hydrogels were constructed by combining the enzyme glucose oxidase with a redox polymer (Fc-C(6)-LPEI) in which ferrocene was attached to linear poly(ethylenimine) by a six-carbon spacer. Incorporation of SWNTs into these films changed their morphology and resulted in a significant increase in the enzymatic response at saturating glucose concentrations (3 mA/cm(2)) as compared to films without SWNTs (0.6 mA/cm(2)). Likewise, the sensitivity at 5 mM glucose was significantly increased in the presence of SWNTs (74 µA/cm(2)·mM) as compared to control films (26 µA/cm(2)·mM). We demonstrate that the increase in the electrochemical and enzymatic response of these films depends on the amount of SWNTs incorporated and the method of SWNT incorporation. Furthermore, we report that the presence of SWNTs in thick films allows for more of the ferrocene redox centers to become accessible. The high current densities of the hydrogels should allow for the construction of miniature biosensors and enzymatic biofuel cells.


Subject(s)
Ferrous Compounds/chemistry , Nanotubes, Carbon/chemistry , Polyethyleneimine/chemistry , Aspergillus niger/enzymology , Electrochemistry , Electron Transport , Glucose Oxidase/metabolism , Hydrogels/chemistry , Metallocenes , Polyethyleneimine/metabolism
SELECTION OF CITATIONS
SEARCH DETAIL
...