Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 86
Filter
1.
Ann Rheum Dis ; 83(8): 1060-1071, 2024 Jul 15.
Article in English | MEDLINE | ID: mdl-38531611

ABSTRACT

OBJECTIVES: The main objective was to generate a GLobal OMERACT Ultrasound DActylitis Score (GLOUDAS) in psoriatic arthritis and to test its reliability. To this end, we assessed the validity, feasibility and applicability of ultrasound assessment of finger entheses to incorporate them into the scoring system. METHODS: The study consisted of a stepwise process. First, in cadaveric specimens, we identified enthesis sites of the fingers by ultrasound and gross anatomy, and then verified presence of entheseal tissue in histological samples. We then selected the entheses to be incorporated into a dactylitis scoring system through a Delphi consensus process among international experts. Next, we established and defined the ultrasound components of dactylitis and their scoring systems using Delphi methodology. Finally, we tested the interobserver and intraobserver reliability of the consensus- based scoring systemin patients with psoriatic dactylitis. RESULTS: 32 entheses were identified in cadaveric fingers. The presence of entheseal tissues was confirmed in all cadaveric samples. Of these, following the consensus process, 12 entheses were selected for inclusion in GLOUDAS. Ultrasound components of GLOUDAS agreed on through the Delphi process were synovitis, tenosynovitis, enthesitis, subcutaneous tissue inflammation and periextensor tendon inflammation. The scoring system for each component was also agreed on. Interobserver reliability was fair to good (κ 0.39-0.71) and intraobserver reliability good to excellent (κ 0.80-0.88) for dactylitis components. Interobserver and intraobserver agreement for the total B-mode and Doppler mode scores (sum of the scores of the individual abnormalities) were excellent (interobserver intraclass correlation coefficient (ICC) 0.98 for B-mode and 0.99 for Doppler mode; intraobserver ICC 0.98 for both modes). CONCLUSIONS: We have produced a consensus-driven ultrasound dactylitis scoring system that has shown acceptable interobserver reliability and excellent intraobserver reliability. Through anatomical knowledge, small entheses of the fingers were identified and histologically validated.


Subject(s)
Arthritis, Psoriatic , Finger Joint , Severity of Illness Index , Ultrasonography , Humans , Arthritis, Psoriatic/diagnostic imaging , Reproducibility of Results , Finger Joint/diagnostic imaging , Finger Joint/pathology , Ultrasonography/methods , Male , Female , Delphi Technique , Synovitis/diagnostic imaging , Synovitis/pathology , Middle Aged , Observer Variation , Enthesopathy/diagnostic imaging , Tenosynovitis/diagnostic imaging , Cadaver , Feasibility Studies , Adult , Aged , Fingers/diagnostic imaging , Fingers/pathology
2.
Semin Arthritis Rheum ; 65: 152378, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38310657

ABSTRACT

Sjögren's disease (SjD) is a systemic autoimmune exocrinopathy with key features of dryness, pain, and fatigue. SjD can affect any organ system with a variety of presentations across individuals. This heterogeneity is one of the major barriers for developing effective disease modifying treatments. Defining core disease domains comprising both specific clinical features and incorporating the patient experience is a critical first step to define this complex disease. The OMERACT SjD Working Group held its first international collaborative hybrid meeting in 2023, applying the OMERACT 2.2 filter toward identification of core domains. We accomplished our first goal, a scoping literature review that was presented at the Special Interest Group held in May 2023. Building on the domains identified in the scoping review, we uniquely deployed multidisciplinary experts as part of our collaborative team to generate a provisional domain list that captures SjD heterogeneity.


Subject(s)
Sjogren's Syndrome , Humans , Treatment Outcome , Sjogren's Syndrome/therapy , Pain , Fatigue
3.
Semin Arthritis Rheum ; 65: 152406, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38401294

ABSTRACT

OBJECTIVES: Over the last years ultrasound has shown to be an important tool for evaluating lung involvement, including interstitial lung disease (ILD) a potentially severe systemic involvement in many rheumatic and musculoskeletal diseases (RMD). Despite the potential sensitivity of the technique the actual use is hampered by the lack of consensual definitions of elementary lesions to be assessed and of the scanning protocol to apply. Within the Outcome Measures in Rheumatology (OMERACT) Ultrasound Working Group we aimed at developing consensus-based definitions for ultrasound detected ILD findings in RMDs and assessing their reliability in dynamic images. METHODS: Based on the results from a systematic literature review, several findings were identified for defining the presence of ILD by ultrasound (i.e., Am-lines, B-lines, pleural cysts and pleural line irregularity). Therefore, a Delphi survey was conducted among 23 experts in sonography to agree on which findings should be included and on their definitions. Subsequently, a web-reliability exercise was performed to test the reliability of the agreed definitions on video-clips, by using kappa statistics. RESULTS: After three rounds of Delphi an agreement >75 % was obtained to include and define B-lines and pleural line irregularity as elementary lesions to assess. The reliability in the web-based exercise, consisting of 80 video-clips (30 for pleural line irregularity, 50 for B-lines), showed moderate inter-reader reliability for both B-lines (kappa = 0.51) and pleural line irregularity (kappa = 0.58), while intra-reader reliability was good for both B-lines (kappa = 0.72) and pleural line irregularity (kappa = 0.75). CONCLUSION: Consensus-based ultrasound definitions for B-lines and pleural line irregularity were obtained, with moderate to good reliability to detect these lesions using video-clips. The next step will be testing the reliability in patients with ILD linked to RMDs and to propose a consensual and standardized protocol to scan such patients.


Subject(s)
Delphi Technique , Lung Diseases, Interstitial , Ultrasonography , Humans , Lung Diseases, Interstitial/diagnostic imaging , Ultrasonography/standards , Reproducibility of Results , Lung/diagnostic imaging , Consensus
4.
J Rheumatol ; 51(3): 263-269, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-37914219

ABSTRACT

OBJECTIVE: To assess the construct validity of the novel Outcome Measures in Rheumatology (OMERACT) ultrasound (US) semiquantitative scoring system for morphological lesions in major salivary glands by comparing it with magnetic resonance imaging (MRI) and unstimulated whole salivary flow rates (U-WSFRs) in patients with primary Sjögren syndrome (pSS). METHODS: Nine sonographers applied the OMERACT 0-3 grayscale scoring system for parotid (PGs) and submandibular glands (SMGs) in 11 patients with pSS who also had MRIs performed. These were evaluated by 2 radiologists using a semiquantitative 0-3 scoring system for morphological lesions. The agreement between US and MRI and the association between U-WSFRs and imaging structural lesions was determined. A score ≥ 2 for both US and MRI was defined as gland pathology. RESULTS: The prevalence of US morphological lesions in 11 patients with a score ≥ 2 was 58% for PGs and 76% for SMGs, and 46% and 41% for PGs and SMGs, respectively, for MRI. The agreement between OMERACT US scores and MRI scores was 73-91% (median 82%) in the right PG and 73-91% (median 91%) in the left PG, 55-91% (median 55%) in the right SMG and 55-82% (median 55%) in the left SMG. When relations between the presence of hyposalivation and an US score ≥ 2 were examined, agreement was 91-100% (median 83%) in both PGs and 55-91% (median 67%) in both SMGs. CONCLUSION: There is moderate to strong agreement between the OMERACT US and MRI scores for major salivary glands in patients with pSS. Similar agreement ratios were observed between the higher OMERACT US scores and presence of hyposalivation.


Subject(s)
Sjogren's Syndrome , Xerostomia , Humans , Sjogren's Syndrome/diagnostic imaging , Salivary Glands/diagnostic imaging , Ultrasonography , Xerostomia/diagnostic imaging , Magnetic Resonance Imaging
5.
Ann Rheum Dis ; 82(4): 556-564, 2023 04.
Article in English | MEDLINE | ID: mdl-36600183

ABSTRACT

OBJECTIVES: To develop an Outcome Measures in Rheumatology (OMERACT) ultrasonography score for monitoring disease activity in giant cell arteritis (GCA) and evaluate its metric properties. METHODS: The OMERACT Instrument Selection Algorithm was followed. Forty-nine members of the OMERACT ultrasonography large vessel vasculitis working group were invited to seven Delphi rounds. An online reliability exercise was conducted using images of bilateral common temporal arteries, parietal and frontal branches as well as axillary arteries from 16 patients with GCA and 7 controls. Sensitivity to change and convergent construct validity were tested using data from a prospective cohort of patients with new GCA in which ultrasound-based intima-media thickness (IMT) measurements were conducted at weeks 1, 3, 6, 12 and 24. RESULTS: Agreement was obtained (92.7%) for the OMERACT GCA Ultrasonography Score (OGUS), calculated as follows: sum of IMT measured in every segment divided by the rounded cut-off values of IMTs in each segment. The resulting value is then divided by the number of segments available. Thirty-five members conducted the reliability exercise, the interrater intraclass correlation coefficient (ICC) for the OGUS was 0.72-0.84 and the median intrareader ICC was 0.91. The prospective cohort consisted of 52 patients. Sensitivity to change between baseline and each follow-up visit up to week 24 yielded standardised mean differences from -1.19 to -2.16, corresponding to large and very large magnitudes of change, respectively. OGUS correlated moderately with erythrocyte sedimentation rate, C reactive protein and Birmingham Vasculitis Activity Score (corrcoeff 0.37-0.48). CONCLUSION: We developed a provisional OGUS for potential use in clinical trials.


Subject(s)
Giant Cell Arteritis , Humans , Giant Cell Arteritis/diagnostic imaging , Carotid Intima-Media Thickness , Reproducibility of Results , Prospective Studies , Temporal Arteries/diagnostic imaging , Ultrasonography/methods
6.
Z Rheumatol ; 81(9): 787-791, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36018373

ABSTRACT

Henrik Sjögren was a Swedish ophthalmologist who wrote a dissertation (in German) consisting of a 131-page long monograph on patients who exhibited a constellation of keratitis sicca, xerostomia and arthritis. This article highlights several key moments of his life and work leading to the delineation of a new syndrome.


Subject(s)
Keratoconjunctivitis Sicca , Sjogren's Syndrome , Xerostomia , Humans , Sjogren's Syndrome/diagnosis
7.
Rheumatology (Oxford) ; 61(8): 3341-3350, 2022 08 03.
Article in English | MEDLINE | ID: mdl-34849616

ABSTRACT

OBJECTIVE: The aim of this exercise from the OMERACT Ultrasound subgroup on Sjögren's syndrome was to develop and assess the reliability of a consensus-based semiquantitative colour Doppler US scoring system for pathologic salivary gland vascularization in patients with primary Sjögren's syndrome (pSS). METHODS: Using the Delphi method, a colour Doppler semiquantitative scoring system for vascularization of bilateral parotid and submandibular glands was developed and tested in static images and on patients (9 pSS patients and 9 sonographers). Intra-reader and inter-reader reliability of grading the salivary glands were computed by weighted Cohen and Light's kappa analysis, respectively. RESULTS: The consensus-based semiquantitative score was: grade 0, no visible vascular signals; grade 1, focal, dispersed vascular signals; grade 2, diffuse vascular signals detected in <50% of the gland; grade 3, diffuse vascular signals in >50% of the gland. In static images, the intra- and inter-reader reliability showed excellent kappa values (95% CI) of 0.90 (0.87, 0.93) and 0.80 (0.74, 0.84), respectively, for all four salivary glands together. In patients, the intra- and inter-reader reliability for all four salivary glands together was kappa = 0.84 (0.73, 0.92) and 0.70 (0.64, 0.76), respectively. CONCLUSION: The consensus-based colour Doppler US scoring for the evaluation of salivary gland vascularization in pSS showed a good inter-reader reliability and excellent intra-reader reliability in static images and in patients. The clinical application of the developed scoring system should be tested in clinical settings.


Subject(s)
Sjogren's Syndrome , Humans , Inflammation/pathology , Reproducibility of Results , Salivary Glands/diagnostic imaging , Salivary Glands/pathology , Sjogren's Syndrome/diagnostic imaging , Sjogren's Syndrome/pathology , Submandibular Gland/diagnostic imaging , Ultrasonography/methods
8.
Ann Rheum Dis ; 81(2): 232-236, 2022 02.
Article in English | MEDLINE | ID: mdl-34407928

ABSTRACT

OBJECTIVES: This study aimed to determine the prevalence of ultrasound-detected tendon abnormalities in healthy subjects (HS) across the age range. METHODS: Adult HS (age 18-80 years) were recruited in 23 international Outcome Measures in Rheumatology ultrasound centres and were clinically assessed to exclude inflammatory diseases or overt osteoarthritis before undergoing a bilateral ultrasound examination of digit flexors (DFs) 1-5 and extensor carpi ulnaris (ECU) tendons to detect the presence of tenosynovial hypertrophy (TSH), tenosynovial power Doppler (TPD) and tenosynovial effusion (TEF), usually considered ultrasound signs of inflammatory diseases. A comparison cohort of patients with rheumatoid arthritis (RA) was taken from the Birmingham Early Arthritis early arthritis inception cohort. RESULTS: 939 HS and 144 patients with RA were included. The majority of HS (85%) had grade 0 for TSH, TPD and TEF in all DF and ECU tendons examined. There was a statistically significant difference in the proportion of TSH and TPD involvement between HS and subjects with RA (HS vs RA p<0.001). In HS, there was no difference in the presence of ultrasound abnormalities between age groups. CONCLUSIONS: Ultrasound-detected TSH and TPD abnormalities are rare in HS and can be regarded as markers of active inflammatory disease, especially in newly presenting RA.


Subject(s)
Tendons/diagnostic imaging , Tendons/pathology , Tenosynovitis/epidemiology , Adolescent , Adult , Aged , Aged, 80 and over , Cohort Studies , Female , Healthy Volunteers , Humans , Hypertrophy/diagnostic imaging , Hypertrophy/epidemiology , Male , Middle Aged , Prevalence , Tenosynovitis/diagnostic imaging , Ultrasonography , Young Adult
9.
Arthritis Care Res (Hoboken) ; 74(12): 2005-2012, 2022 12.
Article in English | MEDLINE | ID: mdl-34137211

ABSTRACT

OBJECTIVE: To standardize and assess the reliability of ultrasonographic assessment of inflammatory and structural lesions in patients with hand osteoarthritis (OA). METHODS: The Outcome Measures in Rheumatology Ultrasound Working Group selected synovial hypertrophy (SH), joint effusion (JE), and power Doppler (PD) signals as the main inflammatory lesions in hand OA, and suggested osteophytes in the scapho-trapezio-trapezoid (STT) and cartilage defects in the proximal interphalangeal (PIP) joints as novel additions to previous structural scoring systems. A complementary imaging atlas provided detailed examples of the scores. A reliability exercise of static images was performed for the inflammatory features, followed by a patient-based exercise with 6 sonographers testing inflammatory and structural features in 12 hand OA patients. We used Cohen's kappa for intrareader and Light's kappa for interreader reliability for all features except PD, in which prevalence-adjusted bias-adjusted kappa (PABAK) was applied. Percentage agreement was also assessed. RESULTS: The web-based reliability exercise demonstrated substantial intra- and interreader reliability for all inflammatory features (κ > 0.64). In the patient-based exercise, intra- and interreader reliability, respectively, varied: SH κ = 0.73 and 0.45; JE κ = 0.70 and 0.55; PD PABAK = 0.90 and 0.88; PIP joint cartilage κ = 0.56 and 0.45; and STT osteophytes κ = 0.62 and 0.36. Percentage close agreement was high for all features (>85%). CONCLUSION: With ultrasound, substantial to excellent intrareader reliability was found for inflammatory features of hand OA. Interreader reliability was moderate, but overall high close agreement between readers suggests that better reliability is achievable after further training. Assessment of osteophytes in the STT joint and cartilage in the PIP joints achieved less reliability and the latter is not endorsed.


Subject(s)
Osteoarthritis , Osteophyte , Rheumatology , Synovitis , Humans , Osteophyte/diagnostic imaging , Reproducibility of Results , Osteoarthritis/diagnostic imaging , Ultrasonography/methods , Outcome Assessment, Health Care , Observer Variation
10.
Semin Arthritis Rheum ; 51(4): 951-956, 2021 08.
Article in English | MEDLINE | ID: mdl-34140184

ABSTRACT

OBJECTIVES: To define chronic ultrasound lesions of the axillary artery (AA) in long-standing giant cell arteritis (GCA) and to evaluate the reliability of the new ultrasound definition in a web-based exercise. METHODS: A structured Delphi, involving an expert panel of the Large Vessel Vasculitis subgroup of the Outcome Measures in Rheumatology (OMERACT) Ultrasound Working Group was carried out. The reliability of the new definition was tested in a 2-round web-based exercise involving 23 experts and using 50 still images each from AA of long-standing and acute GCA patients, as well as 50 images from healthy individuals. RESULTS: The final OMERACT ultrasound definition of chronic changes was based on measurement and appearance of the intima-media complex. The overall reliability of the new definition for chronic ultrasound changes in longstanding GCA of the AA was good to excellent with Light's kappa values of 0.79-0.80 for inter-reader reliability and mean Light's-kappa of 0.88 for intra-reader reliability. The mean inter-rater and intra-rater agreements were 86-87% and 92%, respectively. Good reliabilities were observed comparing the vessels with longstanding versus acute GCA with a mean agreement and kappa values of 81% and 0.63, respectively. CONCLUSION: The new OMERACT ultrasound definition for chronic vasculitis of the AA in GCA revealed a good to excellent inter- and intra-reader reliability in a web-based exercise of experts.


Subject(s)
Giant Cell Arteritis , Rheumatology , Axillary Artery/diagnostic imaging , Giant Cell Arteritis/diagnostic imaging , Humans , Reproducibility of Results , Ultrasonography
11.
Rheumatology (Oxford) ; 60(11): 5239-5246, 2021 11 03.
Article in English | MEDLINE | ID: mdl-33682887

ABSTRACT

OBJECTIVES: Suboptimal medication adherence is a serious problem in the treatment of chronic inflammatory diseases. To measure medication adherence, electronic monitoring is regarded as superior to pill count. GLORIA is an ongoing two-year trial on the addition of low-dose (5 mg/d) prednisolone or placebo to standard care in older people (65+ years) with RA. During the entire trial, adherence is measured with electronic caps, and with pill counts. The objective is to describe medication adherence patterns, and to compare the adherence results of the two methods. METHODS: The recorded adherence patterns of patients (blinded for treatment group) were classified according to descriptive categories. The cutoff for good adherence was set at 80% of prescribed pills taken. RESULTS: Trial inclusion closed in 2018 at 451 patients, but trial follow-up is ongoing; the current dataset contains adherence data of 371 patients. Mean number of recorded 90-day periods per patient was 4 (range 1-8). Based on pill count over all periods, 90% of the patients had good adherence; based on cap data, only 20%. Cap data classified 30% of patients as non-user (<20% of days an opening) and 40% as irregular user (different adherence patterns, in or between periods). CONCLUSION: In our trial of older people with RA, the majority appeared to be adherent to medication according to pill count. Results from caps conflicted with those of pill counts, with patterns suggesting patients did not use the bottle for daily dispensing, despite specific advice to do so. TRIAL REGISTRATION: NCT02585258. ClinicalTrials.gov (https://www.clinicaltrials.gov/).


Subject(s)
Arthritis, Rheumatoid/drug therapy , Drug Packaging/statistics & numerical data , Glucocorticoids/therapeutic use , Medication Adherence/statistics & numerical data , Prednisolone/therapeutic use , Aged , Aged, 80 and over , Female , Humans , Male
12.
Semin Arthritis Rheum ; 51(3): 661-676, 2021 06.
Article in English | MEDLINE | ID: mdl-33386164

ABSTRACT

AIMS: To analyze whether there is sufficient data from published literature to demonstrate that ultrasound, including elastography, present good metric properties (truth, discrimination and feasibility) in autoimmune myositis (AIM). METHODS: A population, intervention, comparator and outcome-structured (PICO) search was performed in Medline, Cochrane Library and Embase database from 01/01/1973 to 08/05/2019. The inclusion criteria required original research involving adult humans, reported in English, assessing ultrasound and elastography in patients with an AIM. Conference abstracts and computer-assisted diagnostics that focused on technique and not ultrasound domains were excluded. RESULTS: Approximately 2670 articles were identified. Forty-one full-text articles were included in the final analysis. There were 551 AIM patients studied. Eighteen studies (43.9%) had a control group, of which 15 (63.3%) were healthy controls. The age of participants (including controls) varied from 18 to 86 years, and most were females (59%). Diagnosis of AIM was largely biopsy-proven, although some were derived through clinical presentation, positive clinical imaging (ultrasound or otherwise) and/or electromyography and steroid responsiveness. The features examined with ultrasound in the 41 included articles consisted of: muscle echogenicity, bulk, atrophy, architecture, power Doppler, perfusion characteristics, shear wave modulus, shear wave velocity, elasticity index and fasciculations. Twelve studies (29.2%) used quantitative methods to assess these characteristics, whilst others used semi-quantitative, dichotomous/binary and descriptive scoring systems. Criterion validity was met in 14 studies (12/14, 85.7%) and construct validity in 22 studies (22/25, 88.0%). Most published articles reported Level 3b to Level 5 evidence with varying degrees of bias. There was only one longitudinal study examining discrimination. Reliability and feasibility were under-reported. CONCLUSION: This is the first systematic review studying the utility of ultrasound, including elastography, in AIM. There is some evidence for criterion and construct validity, suggesting that ultrasound may be a promising outcome measurement instrument in AIM. Agreement on the standardization of acquisition, and the definitions of target domains, is required. Additionally, further validation studies are required to determine discrimination, reliability and feasibility.


Subject(s)
Elasticity Imaging Techniques , Myositis , Adolescent , Adult , Aged , Aged, 80 and over , Female , Humans , Longitudinal Studies , Middle Aged , Myositis/diagnostic imaging , Reproducibility of Results , Ultrasonography , Young Adult
13.
Semin Arthritis Rheum ; 51(3): 644-649, 2021 06.
Article in English | MEDLINE | ID: mdl-33468347

ABSTRACT

OBJECTIVE: This study aimed to develop (1) a new ultrasound definition for aggregates and (2) a semi-quantitative ultrasound scoring system (0-3) for tophus, double contour and aggregates. Furthermore, the intra- and inter-reader reliabilities of both the re-defined aggregates and the semi-quantitative scoring system were assessed using static image exercises. METHODS: Thirty-seven rheumatologists were invited. A Delphi process was used for re-defining aggregates and for selecting a semi-quantitative scoring system with >75% agreement obligate for reaching consensus. Subsequently, a web-based exercise on static ultrasound images was conducted in order to assess the reliability of both the re-defined aggregates and the semi-quantitative scoring system. RESULTS: Twenty rheumatologists contributed to all rounds of the Delphi and image exercises. A consensual re-definition of aggregates was obtained after three Delphi rounds but needed an overarching principle for scoring aggregates in patients. A consensus-based semi-quantitative ultrasound scoring system for gout lesions was developed after two Delphi rounds. The re-definition of aggregates showed good intra- and inter-reader reliability (κ-values 0.71 and 0.61). The reliabilities of the scoring system were good for all lesions with slightly higher intra-reader (κ-values 0.74-0.80) than inter-reader reliabilities (κ-values 0.61-0.67). CONCLUSION: A re-definition of aggregates was obtained with a good reliability when assessing static images. The first consensus-based semi-quantitative ultrasound scoring system for gout-specific lesions was developed with good inter- and intra-reader reliability for all lesions when tested in static images. The next step is to assess the reliabilities when scoring lesions in patients.


Subject(s)
Gout , Consensus , Exercise , Gout/diagnostic imaging , Humans , Observer Variation , Reproducibility of Results , Ultrasonography
14.
Ann Rheum Dis ; 80(7): 840-847, 2021 07.
Article in English | MEDLINE | ID: mdl-33483318

ABSTRACT

OBJECTIVE: To produce European League Against Rheumatism (EULAR) recommendations for the reporting of ultrasound studies in rheumatic and musculoskeletal diseases (RMDs). METHODS: Based on the literature reviews and expert opinion (through Delphi surveys), a taskforce of 23 members (12 experts in ultrasound in RMDs, 9 in methodology and biostatistics together with a patient research partner and a health professional in rheumatology) developed a checklist of items to be reported in every RMD study using ultrasound. This checklist was further refined by involving a panel of 79 external experts (musculoskeletal imaging experts, methodologists, journal editors), who evaluated its comprehensibility, feasibility and comprehensiveness. Agreement on each proposed item was assessed with an 11-point Likert scale, grading from 0 (total disagreement) to 10 (full agreement). RESULTS: Two face-to-face meetings, as well as two Delphi rounds of voting, resulted in a final checklist of 23 items, including a glossary of terminology. Twenty-one of these were considered 'mandatory' items to be reported in every study (such as blinding, development of scoring systems, definition of target pathologies) and 2 'optional' to be reported only if applicable, such as possible confounding factors (ie, ambient conditions) or experience of the sonographers. CONCLUSION: An EULAR taskforce developed a checklist to ensure transparent and comprehensive reporting of aspects concerning research and procedures that need to be presented in studies using ultrasound in RMDs. This checklist, if widely adopted by authors and editors, will greatly improve the interpretability of study development and results, including the assessment of validity, generalisability and applicability.


Subject(s)
Musculoskeletal Diseases/diagnostic imaging , Research Design/standards , Rheumatic Diseases/diagnostic imaging , Rheumatology/standards , Ultrasonography/methods , Humans
16.
Ann Rheum Dis ; 80(2): 261-267, 2021 02.
Article in English | MEDLINE | ID: mdl-32988839

ABSTRACT

OBJECTIVE: To evaluate the discriminatory ability of ultrasound in calcium pyrophosphate deposition disease (CPPD), using microscopic analysis of menisci and knee hyaline cartilage (HC) as reference standard. METHODS: Consecutive patients scheduled for knee replacement surgery, due to osteoarthritis (OA), were enrolled. Each patient underwent ultrasound examination of the menisci and HC of the knee, scoring each site for presence/absence of CPPD. Ultrasound signs of inflammation (effusion, synovial proliferation and power Doppler) were assessed semiquantitatively (0-3). The menisci and condyles, retrieved during surgery, were examined microscopically by optical light microscopy and by compensated polarised microscopy. CPPs were scored as present/absent in six different samples from the surface and from the internal part of menisci and cartilage. Ultrasound and microscopic analysis were performed by different operators, blinded to each other's findings. RESULTS: 11 researchers from seven countries participated in the study. Of 101 enrolled patients, 68 were included in the analysis. In 38 patients, the surgical specimens were insufficient. The overall diagnostic accuracy of ultrasound for CPPD was of 75%-sensitivity of 91% (range 71%-87% in single sites) and specificity of 59% (range 68%-92%). The best sensitivity and specificity were obtained by assessing in combination by ultrasound the medial meniscus and the medial condyle HC (88% and 76%, respectively). No differences were found between patients with and without CPPD regarding ultrasound signs of inflammation. CONCLUSION: Ultrasound demonstrated to be an accurate tool for discriminating CPPD. No differences were found between patents with OA alone and CPPD plus OA regarding inflammation.


Subject(s)
Chondrocalcinosis/diagnostic imaging , Hyaline Cartilage/diagnostic imaging , Meniscus/diagnostic imaging , Osteoarthritis, Knee/diagnostic imaging , Ultrasonography/statistics & numerical data , Aged , Arthroplasty, Replacement, Knee , Calcium Pyrophosphate/analysis , Female , Humans , Hyaline Cartilage/pathology , Male , Meniscus/pathology , Microscopy/methods , Microscopy/statistics & numerical data , Middle Aged , Osteoarthritis, Knee/pathology , Osteoarthritis, Knee/surgery , Preoperative Period , Reference Values , Reproducibility of Results , Sensitivity and Specificity
17.
Rheumatology (Oxford) ; 60(5): 2169-2176, 2021 05 14.
Article in English | MEDLINE | ID: mdl-33085747

ABSTRACT

BACKGROUND: To assess the reliability of the consensually agreed US definitions of major salivary gland lesions and the US scoring system for salivary gland assessment in patients with SS. METHODS: Nine experienced sonographers scanned and read the US images of both parotid glands (PGs) and submandibular glands (SMGs) in eight patients with primary and secondary SS in two rounds. A consensually agreed four-grade semi-quantitative scoring was applied in B-mode for morphological lesions: grade 0, normal; grade 1, mild inhomogeneity without anechoic or hypoechoic areas; grade 2, moderate inhomogeneity with focal anechoic or hypoechoic areas; grade 3, severe inhomogeneity with diffuse an- or hypoechoic areas occupying the entire gland or fibrous gland. The presence or absence of typical SS lesions, i.e. the Sjögren's signature, was scored binary. Intra- and interreader reliabilities were computed using weighted and unweighted Cohen's and Light's κ coefficients. RESULTS: The mean prevalence of grades 0-3 in PG were 43, 17, 23 and 31% and 28, 14, 33 and 32% for the SMGs, respectively. The weighted κ for intrareader reliability ranged from 0.44 to 1 for grading and 0.64 to 1 for the Sjögren's signature of PG and 0.59 to 1 and -0.09 to 0.6 for SMGs, respectively. The interreader reliability κ for grading in PG was 0.62 (95% CI 0.47, 0.74) and for Sjögren's signature it was 0.36 (95% CI 0, 0.43); in SMG it was 0.62 (95% CI 0.47, 0.72) and 0.03 (95% CI 0, 0.07) respectively. CONCLUSIONS: The consensually agreed novel US scoring system for major salivary gland lesions showed substantial intra- and interreader reliability in patients with SS. The reliability of the Sjögren's signature was moderate.


Subject(s)
Parotid Gland/diagnostic imaging , Sjogren's Syndrome/diagnostic imaging , Submandibular Gland/diagnostic imaging , Adult , Aged , Female , Humans , Male , Middle Aged , Outcome Assessment, Health Care , Reproducibility of Results , Ultrasonography
18.
Praxis (Bern 1994) ; 109(12): 955-956, 2020 Sep.
Article in German | MEDLINE | ID: mdl-32933398

ABSTRACT

CME Sonography 93/Answers: Ultrasound of the Enthesis - Not Every Enthesitis Signals a Spondyloarthritis Abstract. In this CME we will focus on the ultrasound anatomy of the enthesis. It is important to know all the diseases that can manifest themselves at the enthesis, so that diagnoses can be made, and patients classified correctly. At this point it is worth mentioning that the findings of enthesitis do not necessarily need to be associated with spondylarthritis.


Subject(s)
Enthesopathy , Spondylarthritis , Enthesopathy/diagnostic imaging , Humans , Spondylarthritis/diagnostic imaging , Ultrasonography
19.
Praxis (Bern 1994) ; 109(11): 888-896, 2020 Sep.
Article in German | MEDLINE | ID: mdl-32873169

ABSTRACT

CME Sonography 93: Ultrasound of the Enthesis - Not Every "Enthesitis" Signals a Spondyloarthritis Abstract. In this CME we will focus on the ultrasound anatomy of the enthesis. In addition, we describe the terms enthesopathy and enthesitis and discuss related differential diagnostic considerations. It is important to know all the diseases that can manifest themselves at the enthesis, so that diagnoses can be made, and patients classified correctly. At this point it is worth mentioning that the findings of enthesitis do not necessarily need to be associated with spondylarthritis.


Subject(s)
Enthesopathy , Spondylarthritis , Humans , Spondylarthritis/diagnostic imaging , Ultrasonography
20.
J Rheumatol ; 47(7): 945-946, 2020 07 01.
Article in English | MEDLINE | ID: mdl-32611772
SELECTION OF CITATIONS
SEARCH DETAIL