Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Publication year range
1.
Shanghai Kou Qiang Yi Xue ; 31(6): 581-587, 2022 Dec.
Article in Chinese | MEDLINE | ID: mdl-36970792

ABSTRACT

PURPOSE: To trace the fate of transplanted stem cells from human exfoliated deciduous teeth (SHED) in the repair of periodontal bone defects, Molday ION rhodamine B (MIRB) was used to label SHED and explore the mechanism of SHED in the repair of periodontal bone defects. METHODS: In vitro cultured SHED were labeled by MIRB. The labeling efficiency, cell survival, proliferation and osteogenic differentiation of MIRB-labelled SHED were detected. The labeled cells were transplanted into the rat model with periodontal bone defect. The survival, differentiation and improvement of host periodontal bone healing of MIRB labeled SHED in vivo were analyzed by immunohistochemistry and fluorescence co-staining, nuclear magnetic imaging dual-mode tracking and H-E staining. The data were statistically analyzed with SPSS 24.0 software package. RESULTS: MIRB labeled SHED did not affect its growth and osteogenic differentiation. The optimal labeling concentration was 25 µg/mL, the labeling efficiency of SHED reached 100%. The transplantation of MIRB labeled SHED in vivo can survive for more than 8 weeks. It was found that MIRB labeled SHED could differentiate into osteoblasts in vivo and significantly promote the repair of alveolar bone defects. CONCLUSIONS: MIRB labeled SHED can be traced in vivo, and the effect of labeled SHED on the repair of defective alveolar bone was observed.


Subject(s)
Dental Pulp , Osteogenesis , Humans , Rats , Animals , Cell Proliferation , Stem Cells , Cell Differentiation , Tooth, Deciduous , Cells, Cultured
2.
Eur J Radiol ; 81(2): 223-5, 2012 Feb.
Article in English | MEDLINE | ID: mdl-21237600

ABSTRACT

OBJECTIVE: To analyze the characteristics of double inversion recovery (DIR) turbo field echo (TFE) and turbo spin echo (TSE) sequences and explore the value of double inversion recovery TFE sequence on carotid artery wall imaging. PATIENTS AND METHODS: 56 patients (32 males and 24 females, aged 31-76 years with a mean age of 53 years) were performed with DIR TFE and DIR TSE T1 weighted imaging (T1WI) sequences on carotid artery bifurcations. Image quality acquired by different techniques were evaluated and scored by two physicians. Whether there is significant difference is determined by SPSS 11.0 software. Paired-samples t test was used for statistics. RESULTS: There was no significant difference in the image quality scores between two sequences (t = 0.880, P = 0.383 > 0.05). CONCLUSIONS: DIR TFE sequence has short scanning time and high spatial resolution. DIR TFE sequence can be used as the preferred sequence for screening carotid atherosclerotic plaque compared with DIR TSE sequence.


Subject(s)
Algorithms , Carotid Arteries/pathology , Carotid Stenosis/pathology , Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Adult , Aged , Female , Humans , Image Enhancement/methods , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Signal Processing, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL
...