Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
Opt Lett ; 46(3): 500-503, 2021 Feb 01.
Article in English | MEDLINE | ID: mdl-33528394

ABSTRACT

Dispersion management is critical in many optical applications, whether to reduce impairments in fiber optic communication or chirp pulse amplification, or to create time stretch instruments for single-shot continuous recording of fast phenomena. The most common solutions for achieving large dispersion with low loss include dispersion compensation fiber, fiber Bragg grating, and diffraction grating pairs. Such dispersive elements have finite operational bandwidth, limited total dispersion, or insufficient power handling. In this Letter, we demonstrate a new, to the best of our knowledge, implementation of the chromo-modal dispersion device based on a silicon waveguide slab that addresses these limitations. The device provides extremely large dispersion with a widely tunable spectrum. We also propose a new time-stretch spectrometer where the absorption cell simultaneously provides spectrum-to-time mapping for fast single-shot spectroscopy.

2.
Biomed Opt Express ; 5(12): 4428-36, 2014 Dec 01.
Article in English | MEDLINE | ID: mdl-25574449

ABSTRACT

Frequency domain fluorescence lifetime imaging is a powerful technique that enables the observation of subtle changes in the molecular environment of a fluorescent probe. This technique works by measuring the phase delay between the optical emission and excitation of fluorophores as a function of modulation frequency. However, high-resolution measurements are time consuming, as the excitation modulation frequency must be swept, and faster low-resolution measurements at a single frequency are prone to large errors. Here, we present a low cost optical system for applications in real-time confocal lifetime imaging, which measures the phase vs. frequency spectrum without sweeping. Deemed Lifetime Imaging using Frequency-multiplexed Excitation (LIFE), this technique uses a digitally-synthesized radio frequency comb to drive an acousto-optic deflector, operated in a cat's-eye configuration, to produce a single laser excitation beam modulated at multiple beat frequencies. We demonstrate simultaneous fluorescence lifetime measurements at 10 frequencies over a bandwidth of 48 MHz, enabling high speed frequency domain lifetime analysis of single- and multi-component sample mixtures.

3.
Opt Express ; 21(18): 21618-27, 2013 Sep 09.
Article in English | MEDLINE | ID: mdl-24104036

ABSTRACT

Time stretch transformation of wideband waveforms boosts the performance of analog-to-digital converters and digital signal processors by slowing down analog electrical signals before digitization. The transform is based on dispersive Fourier transformation implemented in the optical domain. A coherent receiver would be ideal for capturing the time-stretched optical signal. Coherent receivers offer improved sensitivity, allow for digital cancellation of dispersion-induced impairments and optical nonlinearities, and enable decoding of phase-modulated optical data formats. Because time-stretch uses a chirped broadband (>1 THz) optical carrier, a new coherent detection technique is required. In this paper, we introduce and demonstrate coherent time stretch transformation; a technique that combines dispersive Fourier transform with optically broadband coherent detection.

4.
Opt Express ; 21(23): 28960-7, 2013 Nov 18.
Article in English | MEDLINE | ID: mdl-24514410

ABSTRACT

The angular light scattering profile of microscopic particles significantly depends on their morphological parameters, such as size and shape. This dependency is widely used in state-of-the-art flow cytometry methods for particle classification. We introduce a new spectrally encoded angular light scattering method, with potential application in scanning flow cytometry. We show that a one-to-one wavelength-to-angle mapping enables the measurement of the angular dependence of scattered light from microscopic particles over a wide dynamic range. Improvement in dynamic range is obtained by equalizing the angular dependence of scattering via wavelength equalization. Continuous angular spectrum is obtained without mechanical scanning enabling single-shot measurement. Using this information, particle morphology can be determined with improved accuracy. We derive and experimentally verify an analytic wavelength-to-angle mapping model, facilitating rapid data processing. As a proof of concept, we demonstrate the method's capability of distinguishing differently sized polystyrene beads. The combination of this technique with time-stretch dispersive Fourier transform offers real-time and high-throughput (high frame rate) measurements and renders the method suitable for integration in standard flow cytometers.

SELECTION OF CITATIONS
SEARCH DETAIL