Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 27
Filter
1.
Int J Stroke ; : 17474930241260589, 2024 Jun 13.
Article in English | MEDLINE | ID: mdl-38816936

ABSTRACT

BACKGROUND AND OBJECTIVES: Cancer is associated with an increased risk of acute ischemic stroke (AIS) and venous thromboembolism. The role of a cardiac right-to-left shunt (RLS) as a surrogate parameter for paradoxical embolism in cancer-related strokes is uncertain. We sought to investigate the relationship between the presence of an RLS and cancer in AIS patients. METHODS: We included consecutive AIS patients hospitalized at our tertiary stroke center between January 2015 and December 2020 with available RLS status as detected on transesophageal echocardiography (TEE). Active cancers were retrospectively identified and the association with RLS was assessed with multivariable logistic regression and inverse probability of treatment weighting to minimize the ascertainment bias of having a TEE obtained. RESULTS: Of the 2236 AIS patients included, 103 (4.6%) had active cancer, of whom 24 (23%) were diagnosed with RLS. An RLS was present in 774 out of the 2133 AIS patients without active cancer (36%). After adjustment and weighting, the absence of RLS was associated with active cancer (adjusted odds ratio (aOR) 2.29; 95% confidence interval (CI), 1.14-4.58). When analysis was restricted to patients younger than 60 years of age or those with a high-risk RLS (Risk of Paradoxical Embolism Score ⩾ 6), there was no association between RLS and cancer (aOR, 3.07; 95% CI, 0.79-11.88 and aOR, 0.56; 95% CI, 0.10-3.10, respectively). CONCLUSION: RLS was diagnosed less frequently in AIS patients with cancer than in cancer-free patients, suggesting that arterial sources may play a larger role in cancer-related strokes than paradoxical venous embolization. Future studies are needed to validate these findings and evaluate potential therapeutic implications, such as the general indication, or lack thereof, for patent foramen ovale (PFO) closure in this patient population.

2.
Article in English | MEDLINE | ID: mdl-38419585

ABSTRACT

OBJECTIVES: We propose an evolution of a dielectric elastomer actuator-based cardiac assist device that acts as a counterpulsation system. We introduce a new pre-stretched actuator and implant the device in a graft bypass between the ascending and descending aorta to redirect all blood through the device (ascending aorta clamped). The objective was to evaluate the influence of these changes on the assistance provided to the heart. METHODS: The novel para-aortic device and the new implantation technique were tested in vivo in 5 pigs. We monitored the pressure and flow in the aorta as well as the pressure-volume characteristics of the left ventricle. Different activation timings were tested to identify the optimal device actuation. RESULTS: The proposed device helps reducing the end-diastolic pressure in the aorta by up to 13 ± 4.0% as well as the peak systolic pressure by up to 16 ± 3.6%. The early diastolic pressure was also increased up to 10 ± 3.5%. With different activation, we also showed that the device could increase or decrease the stroke volume. CONCLUSIONS: The new setup and the novel para-aortic device presented here helped improve cardiac assistance compared to previous studies. Moreover, we revealed a new way to assist the heart by actuating the device at different starting time to modify the left ventricular stroke volume and stroke work.

3.
Am J Cardiol ; 211: 287-290, 2024 Jan 15.
Article in English | MEDLINE | ID: mdl-37952755

ABSTRACT

We aim to evaluate the reliability and consistency of measuring the aortic valve area (AVA) using 3-dimensional (3D) transesophageal echocardiography and compare it with invasive and noninvasive methods using a continuity equation (CE). Measurements were taken from 119 patients with different severity of aortic stenosis and with normal aortic valve who underwent elective transesophageal echocardiography encompassing the whole spectrum of aortic opening. Three methods were compared to determine AVA. First, the effective AVA was calculated with the standard CE, where the left ventricular outflow tract area was calculated from its 2-dimensional diameter (AVA-CEstd). Second, a modified CE method (AVA-CEmod) was used, in which the left ventricular outflow tract area was measured using 3D-multiplane reconstruction. Third, the geometric AVA was directly measured using 3D-multiplane reconstruction planimetry (AVA-3D). Interobserver and intraobserver variability were analyzed using intraclass correlation coefficients (ICCs). The values were measured by two blinded readers for interobserver variability and by one observer on the same dataset. AVA-3D was significantly larger than AVA-CEmod and AVA-CEstd (1.87 ± 1.00 cm2 vs 1.81 ± 0.92 cm2 p = 0.03 and 1.87 ± 1.00 cm2 vs 1.71 ± 0.85 cm2 p <0.001). However, in the subset of patients with AVA-3D <1.5 cm2, there was no significant difference between AVA-3D and AVA-CEmod (1.06 ± 0.24 vs 1.08 ± 0.26 cm2, paired t test: t = 0.77, degree of freedom = 58, p = 0.44). The ICC between the measurements of AVA-3D and AVA-CEmod (ICC 0.979), and AVA-3D and AVA- CEstd (ICC 0.940), were excellent. AVA-3D delivers very similar results as compared with more established echocardiographic parameters. The difference between effective and geometric AVA did not appear to be clinically relevant in patients with a higher degree of stenosis.


Subject(s)
Aortic Valve Stenosis , Echocardiography, Three-Dimensional , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Reproducibility of Results , Echocardiography, Three-Dimensional/methods , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Echocardiography/methods , Echocardiography, Transesophageal/methods
4.
Artif Organs ; 47(5): 898-905, 2023 May.
Article in English | MEDLINE | ID: mdl-36478260

ABSTRACT

BACKGROUND: The number of patients treated by ventricular assist devices (VAD) and the duration of VAD treatment is increasing. One of the main complications in terms of morbidity and mortality for VAD patients are microbial infections. With this study, we aimed to investigate the epidemiology and microbiological characteristics of infections occurring in a VAD population to identify modifiable factors. METHODS: We retrospectively analyzed patient characteristics, treatments and outcomes of VAD-specific/related infections. All patients implanted in our institution with a continuous flow VAD between January 2009 and January 2019 were included. Risk factors for VAD infection were assessed using simple and multiple linear regressions. RESULTS: Of the 104 patients screened, 99 were included in the analysis, the majority of which were men (78%). At implantation, the mean age was 56 years and the median time on VAD support was 541 days. The overall infection rate per year per patient was 1.4. Forty-seven patients (60%) suffered from VAD-specific/related infection. Half of all infection episodes occurred in the first 4 months but the proportion of VAD-specific/related infection was higher after the first 4 months (74% of all infection). Using regression models, no patient specific risk factors were associated with VAD-specific/related infections. CONCLUSION: No predictive factors for infection during VAD support were identified in this study. By extension, diabetes, renal insufficiency, age or high BMI are not sufficient to deny a patient access to ventricular support.


Subject(s)
Diabetes Mellitus , Heart Failure , Heart-Assist Devices , Male , Humans , Female , Middle Aged , Retrospective Studies , Heart-Assist Devices/adverse effects , Heart-Assist Devices/microbiology , Cohort Studies , Risk Factors , Heart Failure/surgery , Heart Failure/etiology , Treatment Outcome
5.
J Appl Physiol (1985) ; 134(2): 387-394, 2023 02 01.
Article in English | MEDLINE | ID: mdl-36519566

ABSTRACT

We analyzed the relationship between flow (Q) and aortic valve opening area (AVA) using a sequence of echocardiographic stress tests of increasing strength. Low-dose dobutamine stress echocardiography (DSE) has been used to differentiate pseudo-severe from true severe aortic stenoses. Because the Q-response to DSE is so variable between individuals, AVA has been projected to a standardized flow (AVAproj) using linear interpolation. A linear Q-to-AVA relation implies that AVA shows an unconstrained increase. We applied three stress maneuvers of increasing strength to investigate whether AVA shows signs of saturation. We performed an echocardiographic examination at rest, during the passive leg raise maneuver ("PLR"), maximal dobutamine infusion ("Dmax"), and their combination ("Dmax + PLR") in 45 patients with severe low-flow, low-gradient aortic stenosis. We analyzed the effect of the stress maneuver on Q, AVA, valve compliance (VC), and AVAproj. We also compared the proportion of patients with nonconclusive test (ΔQ < 20%) between stress maneuvers. We computed the Akaike information criterion (AIC) to compare a linear with a saturating function for the Q-AVA relation. Q gradually increased from "PLR" to "Dmax" to "Dmax + PLR" (P < 0.0001), whereas the number of nonconclusive tests concomitantly diminished from n = 35 to n = 3. The stress sequence increased AVA (P < 0.001) but decreased AVAproj (P = 0.006) and VC (P = 0.005). In the pooled Q-AVA data, the AIC value was lower for the saturating (sigmoidal) model compared with the linear model fitting (-1,593 vs. -1,504). "Dmax + PLR" is capable of reducing the number of nonconclusive DSE tests. With increasing stress strength, the Q-AVA relation progressively flattens, indicating saturation.NEW & NOTEWORTHY The relation between transaortic flow (Q) and aortic valve opening area (AVA) shows a saturation when three different stress maneuvers are used to increase Q as much as possible. This has implications for the assessment of aortic stenosis severity.


Subject(s)
Aortic Valve Stenosis , Ventricular Function, Left , Humans , Stroke Volume , Dobutamine , Echocardiography, Stress , Severity of Illness Index
6.
Clin Cardiol ; 45(12): 1297-1302, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36330592

ABSTRACT

BACKGROUND: The aim of this prospective, double-blinded study in patients with aortic sclerosis was to determine whether a new calcification propensity measure in the serum could predict disease progression. METHODS: We included 129 consecutive patients with aortic sclerosis as assessed during a routine clinical echocardiographic exam. Clinical, echocardiographic, and serum laboratory parameters were collected, including a new blood test providing an overall measure of calcification propensity by monitoring the maturation time of calciprotein particles (T50 test). The echocardiographic exam was repeated after 1 year. Multiple regression analysis was performed to identify independent predictors of the annual increase of peak transvalvular Doppler velocity (∆vmax). Furthermore, the accuracy of the T50 test to detect patients with the most marked stenosis progression was assessed by receiver operating characteristic (ROC)-analysis. RESULTS: Mean age was 75 ± 9 years, 79% were men. The T50 was 271 ± 58 min. Overall, there was no significant stenosis progression between baseline and follow-up (∆vmax 3.8 ± 29.8 cm/s, p = ns). The T50 test was not found to be an independent linear predictor in multivariate testing. By ROC-analysis, however, a T50-value ≤ 242 min was able to significantly detect a ∆vmax above the 90th percentile (∆vmax ≥ 43 cm/s, AUC = 0.67, p = .04, Sensitivity = 69%, Specificity = 70%). CONCLUSIONS: The T50 test showed a modest but significant ability to identify a pronounced aortic stenosis progression in patients with aortic sclerosis. The test could not be established as an independent linear predictor of disease progression, possibly due to the low valvular disease burden and short follow-up interval.


Subject(s)
Aortic Valve Stenosis , Calcinosis , Male , Humans , Aged , Aged, 80 and over , Female , Prospective Studies , Constriction, Pathologic , Sclerosis , Calcinosis/diagnostic imaging , Aortic Valve Stenosis/diagnosis , Disease Progression
7.
Front Cardiovasc Med ; 9: 960170, 2022.
Article in English | MEDLINE | ID: mdl-36277798

ABSTRACT

Introduction: The aortic valve opening area (AVA), used to quantify aortic stenosis severity, depends on the transvalvular flow rate (Q). The currently accepted clinical echocardiographic method assumes a linear relation between AVA and Q. We studied whether a sigmoid model better describes this relation and determined "isostiffness-lines" across a wide flow spectrum, thus allowing building a nomogram for the non-invasive estimation of valve stiffness. Methods: Both AVA and instantaneous Q (Qinst) were measured at 10 different mean cardiac outputs of porcine aortic valves mounted in a pulsatile flow loop. The valves' cusps were chemically stiffened to obtain three stiffness grades and the procedure was repeated for each grade. The relative stiffness was defined as the ratio between LV work at grade with the added stiffness and at native stiffness grade. AVA peak ¯ corresponding to the selected Q peak ¯ of the highest 3 and 5 cardiac output values was predicted in K-fold cross-validation using sequentially a linear and a sigmoid model. The accuracy of each model was assessed with the Akaike information criterion (AIC). Results: The sigmoid model predicted more accurately AVA peak ¯ (AIC for prediction of AVA with Q peak ¯ of the 3 highest cardiac output values: -1,743 vs. -1,048; 5 highest cardiac output values: -1,471 vs. -878) than the linear model. Conclusion: This study suggests that the relation between AVA and Q can be better described by a sigmoid than a linear model. This construction of "isostiffness-lines" may be a useful method for the assessment of aortic stenosis in clinical echocardiography.

8.
J Am Soc Echocardiogr ; 35(11): 1123-1132, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35863544

ABSTRACT

BACKGROUND: Dobutamine stress echocardiography is used to increase transvalvular flow in patients with low-flow, low-gradient aortic stenosis (AS). Dobutamine fails to increase the stroke volume index (SVI) in one third of patients. The aim of this study was to test whether passive leg raise (PLR) added to dobutamine could increase SVI and transvalvular flow in patients with severe paradoxical low-flow, low-gradient AS. METHODS: Forty-five patients with apparent severe low-flow, low-gradient AS on the basis of traditional measurements were included. Twenty-five were categorized as belonging to the paradox group (left ventricular ejection fraction [EF] ≥ 50%) and 20 to the low EF group (left ventricular EF < 50% or "classical" low-flow, low-gradient AS) for comparison. A four-step stress echocardiographic examination was performed: resting conditions (rest), PLR alone (PLR), maximal dobutamine infusion rate (Dmax), and a combination of Dmax and PLR (Dmax+PLR). Aortic valve area, SVI, and mean transvalvular flow were calculated using both the velocity-time integral (VTI) of left ventricular outflow tract and the Simpson method. Changes compared with rest and between the stress maneuvers were analyzed. RESULTS: In the paradox group, compared with rest, left ventricular end-diastolic volume was significantly decreased with Dmax but was completely restored with Dmax+PLR (rest vs Dmax vs Dmax+PLR: 61 ± 15 vs 49 ± 18 mL [P < .001] vs 61 ± 18 mL [P = NS]). The smallest increase in SVI in the paradox group was observed during Dmax (PLR vs Dmax vs Dmax+PLR: VTI, 38 ± 4 mL/m2 [P < .001] vs 36 ± 7 mL/m2 [P = .019] vs 41 ± 7 mL/m2 [P < .001]; Simpson, 28 ± 6 mL/m2 [P < .001], 21 ± 7 mL/m2 [P = NS], 27 ± 7 mL/m2 [P = NS]). Compared with Dmax, Dmax+PLR was able to achieve a higher SVI (VTI, 36 ± 7 vs 41 ± 7 mL/m2 [P < .001]; Simpson, 21 ± 7 vs 27 ± 7 mL/m2 [P < .001]) and transvalvular flow with the Simpson method only (179 ± 56 vs 219 ± 56 mL/sec, P < .001), as well as a higher mean gradient (34 ± 10 vs 39 ± 12 mm Hg, P = .003) and AVA with the Simpson method (0.64 ± 0.21 vs 0.73 ± 0.21 cm2, P = .026). In the low EF group, only SVI VTI (31 ± 8 vs 35 ± 7 mL/m2, P = .034) and mean gradient (29 ± 12 vs 34 ± 14 mm Hg, P = .003) were higher with Dmax+PLR. The proportion of patients with SVI VTI ≥ 35 mL/m2 and increases of SVI VTI of >20% compared with rest was highest with Dmax+PLR in both groups. CONCLUSIONS: Dobutamine decreases preload in paradoxical low-flow, low-gradient AS. Adding PLR counteracts this effect, resulting in increased SVI and flow (in one method). The combined stress maneuver allowed reclassification of some patients from severe to moderate AS and may therefore be useful in selected cases in this population in which severity is uncertain.


Subject(s)
Aortic Valve Stenosis , Echocardiography, Stress , Humans , Stroke Volume , Aortic Valve/diagnostic imaging , Dobutamine , Ventricular Function, Left , Leg , Aortic Valve Stenosis/diagnosis , Severity of Illness Index , Retrospective Studies
9.
J Stroke Cerebrovasc Dis ; 31(8): 106609, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35753093

ABSTRACT

BACKGROUND AND PURPOSE: Malignancy associated acute ischemic stroke (AIS) requires specific diagnostic work-up, treatment and prevention to improve outcome. This study aimed to develop a biomarker-based score for prediction of occult malignancy in AIS patients. METHODS: Single-center cross-sectional study including consecutive AIS patients treated between July 2017 and November 2018. Patients with active malignancy at presentation, or diagnosed within 1 year thereafter and patients free of malignancy, were included and malignancy associated biomarkers were assessed. LASSO analyses of logistic regression were performed to determine biomarkers predictive of active malignancy. Predictors were derived from a predictive model for active malignancy. A comparison between known and unknown (=occult) malignancies when the index stroke occurred was used to eliminate variables not associated with occult malignancy. A predictive score (OCCULT-5 score) for occult malignancy was developed based on the remaining variables. RESULTS: From 1001 AIS patients, 61 (6%) presented an active malignancy. Thirty-nine (64%) were known and 22 (36%) occult. Five variables were included in the final OCCULT-5 score: age ≥ 77 years, embolic stroke of undetermined source, multi-territorial infarcts, D-dimer levels ≥ 820 µ/gL, and female sex. A score of ≥ 3 predicted an underlying occult malignancy with a sensitivity of 64%, specificity of 73%, positive likelihood ratio of 2.35 and a negative likelihood ratio of 0.50. CONCLUSIONS: The OCCULT-5 score might be useful to identify patients with occult malignancy. It may thus contribute to a more effective and timely treatment and thus lead to a positive impact on overall outcome.


Subject(s)
Ischemic Stroke , Neoplasms , Stroke , Aged , Biomarkers , Cross-Sectional Studies , Female , Humans , Neoplasms/diagnosis , Predictive Value of Tests , Retrospective Studies , Risk Factors , Stroke/diagnosis , Stroke/etiology , Stroke/therapy
10.
J Am Heart Assoc ; 11(9): e024989, 2022 05 03.
Article in English | MEDLINE | ID: mdl-35475357

ABSTRACT

Background We aimed to determine the diagnostic yield of transthoracic (TTE) and transesophageal echocardiography (TEE) in patients with ischemic stroke and transient ischemic attack with established indications for direct oral anticoagulants before the index event. Methods and Results This was a retrospective cohort study of consecutive patients with preceding established indications for long-term therapeutic direct oral anticoagulants presenting to a single comprehensive stroke center with ischemic stroke or transient ischemic attack. Choice of echocardiography modality was based on expert recommendations. The primary outcome was a composite of prespecified management-relevant high-risk findings adjudicated by an expert panel, based on TTE and TEE reports according to evidence-based recommendations. Explorative analyses were performed to identify biomarkers associated with the primary outcome. Of 424 patients included (median [interquartile range] age, 78 [70-84] years; 175 [41%] women; National Institutes of Health Stroke Scale, 4 [1-12]; 67% atrial fibrillation), 292 (69%) underwent echocardiography, while 132 (31%) did not. Modality was TTE in 191 (45%) and TEE in 101 (24%). Median time from index event to echocardiography was 2 (1-3) days. TTE identified 26 of 191 (14%) patients with 35 management-relevant pathologies. TEE identified 16 of 101(16%) patients with 20 management-relevant pathologies. Most management-relevant findings represented indicated coronary artery disease and valvular pathologies. In a further 3 of 191 (2%) patients with TTE and 4 of 101 (4%) patients with TEE, other relevant findings were identified. Variables associated with management-relevant high-risk pathologies included more severe stroke, diabetes, and laboratory biomarkers (NT-proBNP [N-terminal pro-B-type natriuretic peptide], C-reactive protein, d-dimer, and troponin levels). Conclusions In patients with established indications for long-term direct oral anticoagulant therapy and stroke who received echocardiography, both TTE and TEE identified a relevant and similar proportion of management-relevant high-risk pathologies and predictive biomarkers could help to guide diagnostic workup in such patients.


Subject(s)
Ischemic Attack, Transient , Ischemic Stroke , Stroke , Aged , Anticoagulants/therapeutic use , Cohort Studies , Cross-Sectional Studies , Echocardiography/methods , Echocardiography, Transesophageal , Female , Humans , Ischemic Attack, Transient/diagnosis , Ischemic Attack, Transient/drug therapy , Ischemic Attack, Transient/etiology , Ischemic Stroke/diagnostic imaging , Ischemic Stroke/drug therapy , Male , Retrospective Studies , Stroke/diagnostic imaging , Stroke/drug therapy
11.
Heart ; 108(15): 1225-1233, 2022 07 13.
Article in English | MEDLINE | ID: mdl-35351823

ABSTRACT

BACKGROUND: Rheumatic heart disease (RHD) accounts for the highest number of deaths from valvular heart disease globally. Yet, rheumatic aortic stenosis (AS) was excluded from landmark studies investigating the safety and efficacy of transcatheter aortic valve implantation (TAVI). We aimed to describe the clinical and anatomical characteristics of patients with rheumatic AS undergoing TAVI, and to compare procedural and clinical outcomes with patients undergoing TAVI for degenerative AS. METHODS: In a prospective TAVI registry, patients with rheumatic AS were identified based on International Classification of Diseases version 10 codes and/or a documented history of acute rheumatic fever and/or the World Heart Federation criteria for echocardiographic diagnosis of RHD, and were propensity score-matched in a 1:4 ratio to patients with degenerative AS. RESULTS: Among 2329 patients undergoing TAVI, 105 (4.5%) had rheumatic AS. Compared with patients with degenerative AS, patients with rheumatic AS were more commonly female, older, had higher surgical risk and more commonly suffered from multivalvular heart disease. In the unmatched cohort, both technical success (85.7% vs 85.9%, p=0.887) and 1-year cardiovascular mortality (10.0% vs 8.6%; HR 1.16, 95% CI 0.61 to 2.18, p=0.656) were comparable between patients with rheumatic and degenerative AS. In contrast, patients with rheumatic AS had lower rates of 30-day and 1-year cardiovascular mortality compared with matched patients with degenerative AS (1.9% vs 8.9%, adjusted HR (HRadj) 0.18, 95% CI 0.04 to 0.80, p=0.024; and 10.0% vs 20.3%, HRadj 0.44, 95% CI 0.24 to 0.84, p=0.012, respectively). CONCLUSION: TAVI may be a safe and effective treatment strategy for selected elderly patients with rheumatic AS. TRIAL REGISTRATION NUMBER: NCT01368250.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Aged , Aortic Valve Stenosis/surgery , Female , Humans , Male , Propensity Score , Prospective Studies , Risk Factors , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome
12.
Indian Heart J ; 74(3): 260-261, 2022.
Article in English | MEDLINE | ID: mdl-35307399

ABSTRACT

Papathanasiou et al point out that the two different methods of LA volume and diameter measurement in our recent publication could limit the significance of the correlations we reported with PV reconnection and non-PV foci as mechanisms of post AF ablation recurrence. While we acknowledge the lack of statistically significant correlations of smaller echo derived LA diameter with PV reconnection or of a larger angiographic LA volume with non-PV foci, the congruent confidence intervals of this correlation suggest a statistical trend. Non-uniform LA dimensional changes as an expression of structural remodelling may also be a possible explanation. Published data indicates that angiographic LA volumes consistently exhibit a positive bias compared to echocardiographic volumes but do provide intra-procedural measurements better correlating with gold standard techniques like CT or MRI. Finally we agree with Papathanasiou et al that dynamic changes in LA dimensions likely correlate with early and late mechanisms of recurrence and merit prospective studies.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Atria/surgery , Humans , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
13.
Indian Heart J ; 74(2): 120-126, 2022.
Article in English | MEDLINE | ID: mdl-35101393

ABSTRACT

AIMS: Pulmonary vein isolation (PVI) is the treatment of choice of paroxysmal atrial fibrillation (PAF). However, radiofrequency delivery at extra-PV sites may be additionally required. We compared clinical and procedural characteristics of patients undergoing PVI alone versus adjunctive extra-PV substrate modification, at first procedure and repeat procedures for AF recurrence. METHODS: 587 patients with PAF undergoing radiofrequency (RF) ablation were retrospectively included. Extra-PV ablation was performed in case of sustained AF despite PVI, or at re-do procedures without PV conduction recovery. Demographic, clinical and electrophysiological predictors of survival without re-intervention were analysed in patients' groups having undergone one (G1), two (G2) or three or more procedures (G3). RESULTS: At baseline procedure, PV RF ablation time was shorter in G1 compared to G2/G3 whereas extra-PV RF ablation time was greater in G3 compared to G1. The proportion of patients requiring PV re-isolation decreased with repeat procedures. Smaller LA before procedure 1 (p1) or p2 was associated with PV reconnection at p2. Conversely larger LA before p1 was associated with extra-PV substrate modification at p2. Late re-do procedure timing (>1yr) was associated with increasing LA volume. Only longer PV and total RF time predicted poorer survival free from AF without re-intervention. CONCLUSION: Longer PV RF time predicted requirement for re-ablation during follow-up. Smaller LA size predicted an increased probability of PV reconnection and decreased extra-PV substrate modification at p2. LA size decreased in patients undergoing early re-intervention, whereas it increased in patients undergoing re-intervention later on suggesting ongoing remodelling or progression.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/methods , Follow-Up Studies , Heart Atria , Humans , Pulmonary Veins/surgery , Recurrence , Retrospective Studies , Treatment Outcome
14.
Am J Cardiol ; 168: 151-158, 2022 04 01.
Article in English | MEDLINE | ID: mdl-35065801

ABSTRACT

The prevalence and implications of radial artery occlusion (RAO) after transradial catheterization are an intensely discussed topic, resulting in numerous preventive strategies such as adjusted anticoagulation, residual-patency hemostasis, or distal puncture site. The present study aimed at assessing an association of palmar arch, in particular radial artery collateral function and RAO after transradial access (TRA) catheterization. Radial artery collateral function was determined using radial artery pressure signals in the nonobstructed vessel and during brief manual occlusion of the more proximal radial artery. Collateral flow index, the ratio of mean occlusive divided by mean nonocclusive arterial blood pressure, both subtracted by central venous pressure, was determined during manual RAO (radial artery collateral flow index [CFIrad]). The presence or absence of RAO was determined by Doppler ultrasound at least 3 months after TRA. A total of 630 patients with TRA coronary angiography underwent palmar arch, that is, radial and radial plus ulnar artery collateral function assessment. CFIrad was equal to 0.808 ± 0.144 (95% confidence interval 0.797 to 0.819). A total of 200 patients underwent Doppler ultrasound examination of their forearm arterial circulation 301 ± 140 days after TRA. Eight (4%) patients showed signs of RAO, 4 of whom (2%) had a complete RAO and 4 (2%) a stenosis above 30%. Patients with RAO showed a higher CFIrad than those without RAO: 0.900 ± 0.074 versus 0.801 ± 0.154 (p = 0.006). In conclusion, complete RAO as determined by Doppler ultrasound later than 3 months after TRA is rare (2%). In the long run, RAO appears to be related to a very well-developed radial artery collateral function.


Subject(s)
Arterial Occlusive Diseases , Radial Artery , Arterial Occlusive Diseases/diagnosis , Arterial Occlusive Diseases/epidemiology , Arterial Occlusive Diseases/etiology , Cardiac Catheterization/adverse effects , Cardiac Catheterization/methods , Coronary Angiography/methods , Hand , Humans , Punctures
15.
Front Neurol ; 12: 699838, 2021.
Article in English | MEDLINE | ID: mdl-34393979

ABSTRACT

Background: To compare the diagnostic yield of echocardiography and cardiovascular MRI (CMR) to detect structural sources of embolism, in patients with ischemic stroke with a secondary analysis of non-stroke populations. Methods and Results: We searched MEDLINE/Embase (from 01.01.2000 to 24.04.2021) for studies including CMR to assess prespecified sources of embolism. Comparison included transthoracic and/or transesophageal echocardiography. Two authors independently screened studies, extracted data and assessed bias using the QUADAS-2 tool. Estimates of diagnostic yield were reported and pooled. Twenty-seven studies with 2,525 patients were included in a study-level analysis. Most studies had moderate to high risk of bias. Persistent foramen ovale, complex aortic plaques, left ventricular and left atrial thrombus were the most common pathologies. There was no difference in the yield of left ventricular thrombus detection between both modalities for stroke populations (4 studies), but an increased yield of CMR in non-stroke populations (28.1 vs. 16.0%, P < 0.001, 10 studies). The diagnostic yield in stroke patients for detection of persistent foramen ovale was lower in CMR compared to transoesophageal echocardiography (29.3 vs. 53.7%, P < 0.001, 5 studies). For both echocardiography and CMR the clinical impact of the management consequences derived from many of the diagnostic findings remained undetermined in the identified studies. Conclusions: Echocardiography and CMR seem to have similar diagnostic yield for most cardioaortic sources of embolism except persistent foramen ovale and left ventricular thrombus. Randomized controlled diagnostic trials are necessary to understand the impact on the management and potential clinical benefits of the assessment of structural cardioaortic stroke sources. Registration: PROSPERO: CRD42020158787.

16.
J Appl Physiol (1985) ; 131(3): 905-913, 2021 09 01.
Article in English | MEDLINE | ID: mdl-34236245

ABSTRACT

Function of naturally existing internal mammary artery (IMA)-to-coronary artery anastomoses has been shown by augmented blood supply to the coronary collateral circulation in response to IMA occlusion. Theoretically, this beneficial functional connection is invertible and can be linked to coronary steal, the verification of whose hypothesis would provide alternate proof to the mentioned functional evidence. This was an observational study including 40 patients with chronic coronary syndrome, distal IMA occlusion, and upper limb hyperemia (verum group), and 40 propensity score matched controls (placebo group) without IMA occlusion or hyperemia. Primary study end point was the intergroup difference and temporal development in coronary collateral function (i.e., collateral flow index; CFI) as obtained at 30, 45, and 60 s following a proximal coronary artery balloon occlusion. CFI is the ratio between simultaneous mean coronary occlusive pressure divided by mean aortic pressure both subtracted by central venous pressure. To provoke a steal phenomenon, upper limb hyperemia was induced by upper arm blood pressure cuff deflation following a 5-min suprasystolic inflation ipsilateral to the sensor-wired coronary artery with release immediately after the first CFI measurement. Between the first and the second CFI measurement, CFI change (i.e., CFI@45s - CFI@30s) was absent in the verum group whereas there was CFI recruitment in the placebo group: 0.000 ± 0.023 and +0.009 ± 0.013, respectively; P = 0.032. Among patients with artificial distal IMA occlusion, induction of ipsilateral upper limb hyperemia provokes extracardiac coronary steal as expressed by temporarily absent collateral recruitment as it normally takes place without upper limb hyperemia.NEW & NOTEWORTHY Induction of ipsilateral upper limb hyperemia provokes extracardiac coronary steal among patients with artificial distal internal mammary artery occlusion. Coronary steal via the occluded internal mammary arteries serves as alternate proof of concept of the already existing evidence of their functional extracoronary collateral supply.


Subject(s)
Hyperemia , Mammary Arteries , Coronary Angiography , Coronary Circulation , Humans , Upper Extremity
18.
Cardiol J ; 28(4): 519-527, 2021.
Article in English | MEDLINE | ID: mdl-33438184

ABSTRACT

BACKGROUND: Transcatheter left atrial appendage closure (LAAC) is performed either in conscious sedation (CS) or general anesthesia (GA), and limited data exist regarding clinical outcomes for the two approaches. The aim of the study was to analyze the effect of CS versus GA on acute outcomes in a large patient cohort undergoing LAAC with a Watchman occluder. METHODS: A cohort of 521 consecutive patients underwent LAAC with Watchman occluders at two centers (REGIOMED hospitals, Germany) between 2012 and 2018. One site performed 303 consecutive LAAC procedures in GA, and the other site performed 218 consecutive procedures in CS. The safety endpoint was a composite of major periprocedural complications and postoperative pneumonia. The efficacy endpoint was defined as device success. RESULTS: After a 1:1 propensity score matching, 196 (CS) vs. 115 (GA) patients could be compared. In 5 (2.6%) cases CS was converted to GA. The primary safety endpoint (3.5% [CS] vs. 7.0% [GA], p = 0.18) and its components (major periprocedural complications: 2.5% vs. 3.5%, p = 0.73; postoperative pneumonia: 2.6% vs. 4.3%, p = 0.51) did not differ between the groups. Also, device success was comparable (96.9% vs. 93.9%, p = 0.24). CONCLUSIONS: In patients undergoing LAAC with the Watchman device, conscious sedation and general anesthesia showed comparable device success rates and safety outcomes. The type of anesthesia for LAAC may therefore be tailored to patient comorbidities, operator experience, and hospital logistics.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Surgical Procedures , Stroke , Anesthesia, General , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Conscious Sedation , Humans , Propensity Score , Treatment Outcome
19.
Catheter Cardiovasc Interv ; 97(7): E973-E981, 2021 06 01.
Article in English | MEDLINE | ID: mdl-32930492

ABSTRACT

OBJECTIVES: This study compares procedural and late clinical outcomes of left atrial appendage closure (LAAC) with Amplatzer devices as a single versus a combined procedure with other structural or coronary interventions. BACKGROUND: Multiple cardiac conditions are frequent among elderly patients and invite simultaneous treatment to ensure a favorable patient outcomes. METHODS: 559 consecutive patients (73.3 ± 11.1 years) underwent LAAC with Amplatzer devices at two centres (Bern and Zurich university hospitals, Switzerland) either as a single procedure or combined with other interventions. The primary safety endpoint was a composite of major peri-procedural complications and major bleeding at follow-up, the primary efficacy endpoint included stroke, systemic embolism, and cardiovascular/unexplained death. All event rates are reported per 100 patient-years. RESULTS: In 263 single and 296 combined procedures with percutaneous coronary interventions (47.6%), closure of an atrial septal defect (8.4%) or a patent foramen ovale (36.5%), transcatheter aortic valve implantation (10.1%), mitral clipping (4.1%), atrial fibrillation ablation (8.8%), or another procedure (3.0%) were analyzed. Device success (96.6% [single] vs. 99.0% [combined], p = .08) did not differ between the groups. After a mean follow-up of 2.6 ± 1.5 vs. 2.5 ± 1.5 years and a total of 1,422 patient-years, the primary efficacy (40/677, 5.9% [single] vs. 37/745, 5.0% [combined]; HR, 1.2, 95% CI, 0.8-1.9, p = .44), as well as the primary safety endpoint (25/677, 3.7% vs 28/745, 3.8%; HR, 1.0, 95% CI, 0.6-1.8, p = .89) were comparable. CONCLUSIONS: LAAC with Amplatzer devices combined with structural, coronary, and electrophysiological procedures offers procedural feasibility and safety, as well as long-term efficacy.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Septal Occluder Device , Stroke , Aged , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnosis , Cardiac Catheterization/adverse effects , Humans , Stroke/etiology , Treatment Outcome
20.
EuroIntervention ; 16(9): e767-774, 2020 Oct 09.
Article in English | MEDLINE | ID: mdl-32583806

ABSTRACT

AIMS: Left atrial appendage closure (LAAC) with AMPLATZER occluders is used for stroke prevention in atrial fibrillation (AF). Net clinical benefit compared to medical therapy has not been tested. The aim of this study was to test whether long-term clinical outcome after LAAC with AMPLATZER occluders may be similar to medical therapy. METHODS AND RESULTS: Five hundred consecutive patients who underwent LAAC with AMPLATZER occluders were compared to 500 patients with medical therapy by propensity score matching. The primary efficacy endpoint was a composite of stroke, systemic embolism and cardiovascular/unexplained death. The primary safety endpoint consisted of major procedural adverse events and major bleedings. For assessment of net clinical benefit, all of the above-mentioned hazards were combined. After 2,645 patient-years at a mean follow-up of 2.7±1.5 years, the primary efficacy endpoint was reached by 75/1,342, 5.6% in the LAAC group versus 102/1,303, 7.8% per 100 patient-years (hazard ratio [HR] 0.70, 95% confidence interval [CI]: 0.53-0.95, p=0.026). The primary safety endpoint occurred in 48/1,342, 3.6% versus 60/1,303, 4.6% per 100 patient-years (HR 0.80, 95% CI: 0.55-1.18, p=0.21), and the combined hazard endpoint in 109/1,342, 8.1% versus 142/1,303, 10.9% per 100 patient-years (HR 0.76, 95% CI: 0.60-0.97, p=0.018). Patients receiving LAAC demonstrated lower rates of both all-cause and cardiovascular mortality (111/1,342, 8.3% vs 151/1,303, 11.6% per 100 patient-years [HR 0.72, 95% CI: 0.56-0.92, p=0.005] and 54/1,342, 4.0% vs 84/1,303, 6.5% per 100 patient-years [HR 0.64, 95% CI: 0.46-0.89, p=0.007]). CONCLUSIONS: LAAC with AMPLATZER devices showed a net clinical benefit over medical therapy by superior efficacy, similar safety and a benefit in all-cause and cardiovascular mortality.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Cardiac Surgical Procedures , Septal Occluder Device , Stroke , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/complications , Atrial Fibrillation/drug therapy , Humans , Septal Occluder Device/adverse effects , Stroke/etiology , Stroke/prevention & control , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...