Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 211: 330-335, 2019 Mar 15.
Article in English | MEDLINE | ID: mdl-30583163

ABSTRACT

It is proposed a new approach to evaluate the performance of ultraviolet photoreactions by integrating UV-LED and a UV-Vis cuvette as a mini-reactor for kinetic monitoring in a spectrophotometer not influenced by external light. This system uses only 3.0 mL of solutions in a rectangular quartz cuvette with a mini-bar magnetic stirrer in a cell holder and a UV-LED of 5 W with λmax at 370 nm was positioned on the top of the cuvette and maintained at 25.0 oC. The effectiveness of this photoreactor was demonstrated by measuring the real-time degradation of two model compounds, salicylic acid and methylene blue, in homogeneous and heterogenous systems. Photolysis of MB with H2O2 results in increasing of rate constants as [H2O2] increased. Heterogeneous photocatalysis of MB and SA was fastest achieved in ZnO dosage of 0,20 g.L-1. This mini-photoreactor allows monitoring the real-time kinetic performance collecting almost a thousand points in each experiment, leading to accurate rate constants. Moreover, this system presented positive environmental aspects such as: lower reactants and catalyst amounts, lower cost and waste amounts, use of the UV-LED radiation and labor time saving. This is a novel approach to determine the photoreaction effectiveness and it can be applied to systematic studies especially for the kinetic parameter determinations.

2.
Food Chem ; 138(1): 574-80, 2013 May 01.
Article in English | MEDLINE | ID: mdl-23265526

ABSTRACT

This study proposes a FRAP assay adapted to FIA system with a merging zones configuration. The FIA system conditions were optimised with the response surface methodology using the central composite rotatable design. The optimisation parameters studied were: the carrier flow rate, the lengths of the sample and reagent loops, and reactor length. The conditions selected in accordance with the results were: carrier flow rate of 1.00 ml/min, length of the loops 18.2 cm and length of the reaction coil 210.1 cm. The detection and quantification limits were, respectively, 28.6 and 86.8 µmol/l Fe(2+), and the precision was 1.27%. The proposed method had an analytical frequency of 30 samples/h and about 95% less volume of FRAP reagent was consumed. The FRAP assay adapted to the FIA system under the optimised conditions was utilised to determine the antioxidant activity of tea samples.


Subject(s)
Antioxidants/analysis , Chemistry Techniques, Analytical/methods , Ferric Compounds/chemistry , Flow Injection Analysis/methods , Tea/chemistry , Oxidation-Reduction
SELECTION OF CITATIONS
SEARCH DETAIL
...