Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Radiat Prot Dosimetry ; 164(4): 493-6, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25990115

ABSTRACT

In this article, a portable device was presented for continual measuring of equilibrium equivalent concentration (EEC) of (222)Rn based on the Timepix detector with 300-µm-thick active layer. In order to have a portable device, a filtration head was developed for collecting short-lived radon progenies attached on aerosols. The short-lived progenies are estimated from analysing alphas from decay of (218,214)Po from Millipore filter after termination of filtration. Comparison with beta measurement was done as well. The dependence of EEC on an air flow and filtration time was studied. The low-level detection limit for EEC was estimated from the last 10 min of 3-h decay measurement and was found in the range of 40-70 Bq m(-3). EEC was measured in National Radiation Protection Institute radon chamber, and results were compared with the commercial detector Fritra4.


Subject(s)
Air Pollutants, Radioactive/analysis , Radiation Monitoring/instrumentation , Radon Daughters/analysis , Radon/analysis , Aerosols , Air Pollution, Indoor/analysis , Alpha Particles , Analog-Digital Conversion , Beta Particles , Equipment Design , Radiation Monitoring/methods , Signal Processing, Computer-Assisted , Silicon , Ultrafiltration
2.
Radiat Prot Dosimetry ; 160(1-3): 184-7, 2014 Jul.
Article in English | MEDLINE | ID: mdl-24707004

ABSTRACT

After an introduction of Timepix detector, results of these detectors with silicon and cadmium telluride detection layer in assessment of activity of short-lived radon decay products are presented. They were collected on an open-face filter by means of one-grab sampling method from the NRPI radon chamber. Activity of short-lived radon decay products was estimated from measured alpha decays of 218,214Po. The results indicate very good agreement between the use of both Timepix detectors and an NRPI reference instrument, continuous monitor Fritra 4. Low-level detection limit for EEC was estimated to be 41 Bq m(-3) for silicon detection layer and 184 Bq m(-3) for CdTe detection layer, respectively.


Subject(s)
Air Pollutants, Radioactive/analysis , Cadmium Compounds/chemistry , Radiation Monitoring/instrumentation , Radiation Protection/instrumentation , Radon Daughters/analysis , Silicon/chemistry , Tellurium/chemistry , Equipment Design , Humans , Radiation Monitoring/methods , Radiation Protection/methods
3.
Radiat Prot Dosimetry ; 161(1-4): 96-9, 2014 Oct.
Article in English | MEDLINE | ID: mdl-24277875

ABSTRACT

A Timepix detector covered with polyethylene convertors of different thicknesses is presented as a fast neutron real-time dosemeter. The application of different weighting factors in connection with the position of a signal in a Timepix detector enables one to obtain an energy-dependent signal equal to neutron dose equivalents. A simulation of a Timepix detector covered with polyethylene convertors using monoenergetic neutrons is presented. The experimental set-up of a dosemeter was also produced. The first results of detector response using different fast neutron sources are presented.


Subject(s)
Fast Neutrons , Radiometry/instrumentation , Algorithms , Americium , Beryllium , Californium , Computer Simulation , Equipment Design , Neutrons , Polyethylene , Probability , Protons , Radiation Dosage , Radiation Protection/methods , Radiometry/methods , Scattering, Radiation
SELECTION OF CITATIONS
SEARCH DETAIL
...