Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 33
Filter
1.
Methods Mol Biol ; 2030: 143-151, 2019.
Article in English | MEDLINE | ID: mdl-31347116

ABSTRACT

The role of amino acid analysis in bioanalysis has changed from a qualitative to a quantitative technique. With the discovery of both electrospray ionization and matrix-assisted laser desorption ionization in the early 1990s, the use of amino acid analysis for qualitative analysis of proteins and peptides has been replaced by mass spectrometry. Accurate measurement of the relative molecular masses of proteins and peptides, peptide mapping, and sequencing by tandem mass spectrometry provide significantly better qualitative information than can be achieved from amino acid analysis. At NIST, amino acid analysis is used to assign concentration values to protein and peptide standard reference materials (SRMs) which, subsequently, will be used in the calibration of a wide variety of protein and peptide assays, such as those used in clinical diagnostics. It is critical that the amino acid analysis method used at NIST for assigning concentration values in SRM deliver the highest accuracy and precision possible. Therefore, we have developed an amino acid analysis method that uses isotope dilution LC-MS/MS-the analytical technique routinely used at NIST to certify analyte concentrations in SRMs for a wide variety of analytes. We present here our most recent method for the quantification of amino acids using isotope dilution LC-MS/MS.


Subject(s)
Amino Acids/analysis , Tandem Mass Spectrometry/methods , Amino Acids/chemistry , Calibration , Carbon Isotopes/analysis , Carbon Isotopes/chemistry , Chromatography, Liquid/instrumentation , Chromatography, Liquid/methods , Indicator Dilution Techniques , Nitrogen Isotopes/analysis , Nitrogen Isotopes/chemistry , Peptides/analysis , Peptides/chemistry , Reference Standards , Tandem Mass Spectrometry/instrumentation
2.
Clin Chem ; 62(1): 48-69, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26719571

ABSTRACT

BACKGROUND: For many years, basic and clinical researchers have taken advantage of the analytical sensitivity and specificity afforded by mass spectrometry in the measurement of proteins. Clinical laboratories are now beginning to deploy these work flows as well. For assays that use proteolysis to generate peptides for protein quantification and characterization, synthetic stable isotope-labeled internal standard peptides are of central importance. No general recommendations are currently available surrounding the use of peptides in protein mass spectrometric assays. CONTENT: The Clinical Proteomic Tumor Analysis Consortium of the National Cancer Institute has collaborated with clinical laboratorians, peptide manufacturers, metrologists, representatives of the pharmaceutical industry, and other professionals to develop a consensus set of recommendations for peptide procurement, characterization, storage, and handling, as well as approaches to the interpretation of the data generated by mass spectrometric protein assays. Additionally, the importance of carefully characterized reference materials-in particular, peptide standards for the improved concordance of amino acid analysis methods across the industry-is highlighted. The alignment of practices around the use of peptides and the transparency of sample preparation protocols should allow for the harmonization of peptide and protein quantification in research and clinical care.


Subject(s)
Clinical Laboratory Techniques , Mass Spectrometry , Peptides/analysis , Proteomics , Specimen Handling , Guidelines as Topic , Humans , Peptides/isolation & purification , Research Personnel
3.
Clin Chem Lab Med ; 53(5): 677-90, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25999287

ABSTRACT

BACKGROUND: As a part of an International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) project to prepare a commutable reference material for cardiac troponin I (cTnI), a pilot study evaluated current cTnI assays for measurement equivalence and their standardization capability. METHODS: cTnI-positive samples collected from 90 patients with suspected acute myocardial infarction were assessed for method comparison by 16 cTnI commercial assays according to predefined testing protocols. Seven serum pools prepared from these samples were also assessed. RESULTS: Each assay was assessed against median cTnI concentrations measured by 16 cTnI assays using Passing-Bablok regression analysis of 79 patient samples with values above each assay's declared detection limit. We observed a 10-fold difference in cTnI concentrations for lowest to highest measurement results. After mathematical recalibration of assays, the between-assay variation for patient samples reduced on average from 40% to 22% at low cTnI concentration, 37%-20% at medium concentration, and 29%-14% at high concentration. The average reduction for pools was larger at 16%, 13% and 7% for low, medium and high cTnI concentrations, respectively. Overall, assays demonstrated negligible bias after recalibration (y-intercept: -1.4 to 0.3 ng/L); however, a few samples showed substantial positive and/or negative differences for individual cTnI assays. CONCLUSIONS: All of the 16 commercial cTnI assays evaluated in the study demonstrated a significantly higher degree of measurement equivalence after mathematical recalibration, indicating that measurement harmonization or standardization would be effective at reducing inter-assay bias. Pooled sera behaved similarly to individual samples in most assays.


Subject(s)
Blood Chemical Analysis/standards , Troponin I/blood , Adolescent , Calibration , Female , Humans , Myocardium/metabolism , Pilot Projects , Reference Standards , Young Adult
4.
J Proteome Res ; 13(9): 3930-9, 2014 Sep 05.
Article in English | MEDLINE | ID: mdl-25057786

ABSTRACT

Urinary excretion of albumin is a major diagnostic and prognostic marker of renal dysfunction and cardiovascular disease; therefore, accurate measurement of urine albumin is vital to clinical diagnosis. Although intermethod differences and analyte heterogeneity have been reported for urine albumin measurements, accuracy assessments of the available methods have been hindered by the lack of a reference system, including reference measurement procedures and reference materials, for this clinical analyte. To address the need for a reference measurement system for urine albumin, we have developed a candidate reference measurement procedure that utilizes isotope dilution-mass spectrometry (ID-MS) and multiple reaction monitoring (MRM) to quantify full-length urine albumin in a targeted mass spectrometric-based approach. The reference measurement procedure incorporates an isotopically labeled ((15)N) full-length recombinant human serum albumin ((15)N-rHSA) material as the internal standard, which permits the absolute quantitation of albumin in urine. A total of 11 peptides with two transitions per peptide were selected from the tryptic digestion of human serum albumin on the basis of retention time reproducibility, peak intensity, and the degree of HSA sequence coverage. In addition to method validation, the generated calibration curves were used to determine the albumin content in pooled human urine samples to access the accuracy of the MS-based urine albumin quantitation method.


Subject(s)
Albuminuria/urine , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Amino Acid Sequence , Humans , Linear Models , Molecular Sequence Data , Peptide Fragments/chemistry
5.
Anal Chem ; 86(5): 2497-509, 2014 Mar 04.
Article in English | MEDLINE | ID: mdl-24494671

ABSTRACT

Shotgun proteomics experiments integrate a complex sequence of processes, any of which can introduce variability. Quality metrics computed from LC-MS/MS data have relied upon identifying MS/MS scans, but a new mode for the QuaMeter software produces metrics that are independent of identifications. Rather than evaluating each metric independently, we have created a robust multivariate statistical toolkit that accommodates the correlation structure of these metrics and allows for hierarchical relationships among data sets. The framework enables visualization and structural assessment of variability. Study 1 for the Clinical Proteomics Technology Assessment for Cancer (CPTAC), which analyzed three replicates of two common samples at each of two time points among 23 mass spectrometers in nine laboratories, provided the data to demonstrate this framework, and CPTAC Study 5 provided data from complex lysates under Standard Operating Procedures (SOPs) to complement these findings. Identification-independent quality metrics enabled the differentiation of sites and run-times through robust principal components analysis and subsequent factor analysis. Dissimilarity metrics revealed outliers in performance, and a nested ANOVA model revealed the extent to which all metrics or individual metrics were impacted by mass spectrometer and run time. Study 5 data revealed that even when SOPs have been applied, instrument-dependent variability remains prominent, although it may be reduced, while within-site variability is reduced significantly. Finally, identification-independent quality metrics were shown to be predictive of identification sensitivity in these data sets. QuaMeter and the associated multivariate framework are available from http://fenchurch.mc.vanderbilt.edu and http://homepages.uc.edu/~wang2x7/ , respectively.


Subject(s)
Chromatography, Liquid/methods , Quality Control , Tandem Mass Spectrometry/methods , Analysis of Variance , Humans , Multivariate Analysis , Neoplasm Proteins/metabolism , Neoplasms/metabolism , Reproducibility of Results
6.
Clin Chem Lab Med ; 51(5): 981-9, 2013 May.
Article in English | MEDLINE | ID: mdl-23241608

ABSTRACT

BACKGROUND: Increased urinary excretion of albumin reflects kidney damage and is a recognized risk factor for progression of renal and cardiovascular disease. Considerable inter-method differences have been reported for both albumin and creatinine measurement results, and therefore the albumin-to-creatinine ratio. Measurement accuracy is unknown and there are no independent reference measurement procedures for albumin and no reference materials for either measurand in urine. METHODS: The National Kidney Disease Education Program (NKDEP) Laboratory Working Group and the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) have initiated joint projects to facilitate standardization of urinary albumin and creatinine measurement. RESULTS: A candidate LC-MS/MS reference measurement procedure for urinary albumin and candidate reference materials for urinary albumin and creatinine has been developed. The status of validations of these reference system components is reported. CONCLUSIONS: The development of certified reference materials and reference measurement procedures for urinary albumin will enable standardization of this important measurand.


Subject(s)
Albumins/standards , Clinical Chemistry Tests/standards , Creatinine/standards , Laboratories/standards , Albumins/analysis , Chromatography, Liquid/standards , Creatinine/urine , Humans , Reference Standards , Tandem Mass Spectrometry/standards
7.
Protein Expr Purif ; 85(1): 94-9, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22796447

ABSTRACT

Levels of C-reactive protein (CRP) in serum are correlated with inflammation and disease in humans. A higher level quantitative method, such as isotope-dilution mass spectrometry (ID-MS) is needed to compare and standardize the many commercial CRP assays. We compare the expression and purification of (15)N-CRP from Escherichia coli and Pichia pastoris and show that the protein isolated from P. pastoris has native pentameric structure along with high isotopic enrichment as shown by software developed specifically for this purpose. When this preparation was mixed in various ratios with unlabeled CRP and tryptic peptides of the mixtures were analyzed by LC-MS/MS, the ratios of heavy and light peaks were tightly correlated with input amounts of each protein. In this report we confirm the suitability of (15)N-rCRP as an internal standard in ID-MS. Standardization of CRP assays should help validate the relationship between CRP and human health.


Subject(s)
C-Reactive Protein/chemistry , C-Reactive Protein/genetics , Escherichia coli/genetics , Pichia/genetics , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization , Amino Acid Sequence , C-Reactive Protein/isolation & purification , Gene Expression , Humans , Isotope Labeling , Molecular Sequence Data , Nitrogen Isotopes/chemistry , Plasmids/genetics , Recombinant Proteins/chemistry , Recombinant Proteins/genetics , Recombinant Proteins/isolation & purification , Transformation, Genetic
8.
Methods Mol Biol ; 828: 29-38, 2012.
Article in English | MEDLINE | ID: mdl-22125133

ABSTRACT

The role of amino acid analysis in bioanalysis has changed from a qualitative to a quantitative technique. With the discovery of both electrospray ionization and matrix-assisted laser desorption ionization in the early 1990s, the use of amino acid analysis for qualitative analysis of proteins and peptides has been replaced by mass spectrometry. Accurate measurement of the relative molecular masses of proteins and peptides, peptide mapping, and sequencing by tandem mass spectrometry provide significantly better qualitative information than can be achieved from amino acid analysis. At NIST, amino acid analysis is used to assign concentration values to protein and peptide standard reference materials (SRMs) which, subsequently, will be used in the calibration of a wide variety of protein and peptide assays, such as those used in clinical diagnostics. It is critical that the amino acid analysis method used at NIST for SRM measurement deliver the highest accuracy and precision possible. Therefore, we have developed an amino acid analysis method that uses isotope dilution LC-MS/MS - the analytical technique routinely used at NIST to certify analyte concentrations in SRMs for a wide variety of analytes. Amino acid analysis by isotope dilution LC-MS/MS was first used to measure the concentration of bovine serum albumin in NIST SRM 927d ("bovine serum albumin, 7% solution"). We have recently refined our isotope dilution LC-MS/MS amino acid analysis method to certify the concentration of 17 amino acids in NIST SRM 2389a ("amino acids in 0.1 mol/L hydrochloric acid"). We present here our most recent method for the quantification of amino acids using isotope dilution LC-MS/MS.


Subject(s)
Amino Acids/analysis , Chromatography, Liquid/methods , Isotope Labeling/methods , Tandem Mass Spectrometry/methods , Amino Acids/chemistry , Animals , Calibration , Cattle , Indicator Dilution Techniques , Serum Albumin, Bovine/analysis
10.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(26): 2726-32, 2011 Sep 15.
Article in English | MEDLINE | ID: mdl-21856254

ABSTRACT

A mass spectrometry-based antibody selection procedure was developed to evaluate optimal 'capture' monoclonal antibodies that can be used in a variety of analytical measurement applications. The isotope-dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) methodology is based on the use of multiple-reaction monitoring of tryptic peptide fragments derived from protein antigens. A panel of monoclonal antibodies (mAb) was evaluated based on a quantitative determination of relative binding affinity to human cardiac troponin I following immunoprecipitation. Dissociation constants (K(d)) were determined for 'bound mAb-antigen' vs. 'unbound antigen' using non-linear regression analysis. Relative quantification of both antigen and antibody was based on the use of stable isotope-labeled synthetic peptides as internal standards. Optimal 'capture' mAbs were determined through evaluation of relative K(d) constants of all monitored peptide transitions. A panel of six pre-screened candidate capture mAbs was concluded to consist of two subsets of mAbs, each with statistically equivalent K(d) constants as determined using NIST Standard Reference Material (SRM) 2921 - Human Cardiac Troponin Complex. This ID LC-MS/MS method is shown to be capable of quantitatively differentiating mAbs based on relative binding affinities. Selection of optimal capture mAbs can be applied toward a number of analytical applications which require metrological traceability and unbiased quantification.


Subject(s)
Antibodies, Monoclonal/metabolism , Antibody Affinity , Chromatography, Liquid/methods , Immunoprecipitation/methods , Peptides/metabolism , Tandem Mass Spectrometry/methods , Amino Acid Sequence , Antibodies, Monoclonal/chemistry , Humans , Isotope Labeling , Microspheres , Molecular Sequence Data , Nonlinear Dynamics , Peptides/analysis , Peptides/chemistry , Protein Binding , Reference Standards , Reproducibility of Results , Troponin I/analysis , Troponin I/chemistry , Troponin I/metabolism
11.
Clin Chem ; 57(8): 1108-17, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21677092

ABSTRACT

Results between different clinical laboratory measurement procedures (CLMP) should be equivalent, within clinically meaningful limits, to enable optimal use of clinical guidelines for disease diagnosis and patient management. When laboratory test results are neither standardized nor harmonized, a different numeric result may be obtained for the same clinical sample. Unfortunately, some guidelines are based on test results from a specific laboratory measurement procedure without consideration of the possibility or likelihood of differences between various procedures. When this happens, aggregation of data from different clinical research investigations and development of appropriate clinical practice guidelines will be flawed. A lack of recognition that results are neither standardized nor harmonized may lead to erroneous clinical, financial, regulatory, or technical decisions. Standardization of CLMPs has been accomplished for several measurands for which primary (pure substance) reference materials exist and/or reference measurement procedures (RMPs) have been developed. However, the harmonization of clinical laboratory procedures for measurands that do not have RMPs has been problematic owing to inadequate definition of the measurand, inadequate analytical specificity for the measurand, inadequate attention to the commutability of reference materials, and lack of a systematic approach for harmonization. To address these problems, an infrastructure must be developed to enable a systematic approach for identification and prioritization of measurands to be harmonized on the basis of clinical importance and technical feasibility, and for management of the technical implementation of a harmonization process for a specific measurand.


Subject(s)
Clinical Laboratory Techniques/standards , Quality Assurance, Health Care , Biomarkers/analysis , Humans , International Cooperation , Practice Guidelines as Topic , Reference Standards , Sensitivity and Specificity
12.
Clin Chem Lab Med ; 48(11): 1603-10, 2010 Nov.
Article in English | MEDLINE | ID: mdl-21062228

ABSTRACT

In this study, the first steps in the development of a secondary reference measurement procedure (RMP) 'higher metrological order measurement procedure' to support the cardiac troponin I (cTnI) standardization initiative is described. The RMP should be used to assign values to serum-based secondary reference materials (RMs) without analytical artifacts causing bias. A multiplexed bead-based assay and sodium dodecyl sulfate polyacrylamide gel electrophoresis (SDS-PAGE) were used to identify the optimum monoclonal antibody pair (clones 560 and 19C7) for the RMP. Using these antibodies, an ELISA-based procedure was developed to accurately measure the main cTnI forms present in blood. The proposed RMP appears to show no bias when tested on samples containing various troponin complexes, phosphorylated and dephosphorylated forms, and heparin. The candidate assay displayed suitable linearity and sensitivity (limit of detection, 0.052 µg/L) for the measurement of the proposed cTnI secondary RMs. Preliminary comparison data on patient samples with a commercial cTnI assay are also provided to support the suitability of RMP for value assignment to RMs. Full validation and final assessment of the RMP will be performed through transferability and inter-comparison studies.


Subject(s)
Antibodies, Monoclonal/immunology , Blood Chemical Analysis/standards , Enzyme-Linked Immunosorbent Assay/standards , Myocardium , Troponin I/blood , Antibody Specificity , Electrophoresis, Polyacrylamide Gel , Humans , Immunoprecipitation , International Agencies , Male , Reference Standards , Spectrometry, Fluorescence , Troponin I/immunology
13.
Proteomics ; 10(23): 4220-5, 2010 Dec.
Article in English | MEDLINE | ID: mdl-21046617

ABSTRACT

In order to improve the repeatability, comparability, and accuracy of MS-based proteomic measurements, there has been considerable international effort to develop appropriate reference materials. Although the majority of reference materials are developed to support measurement quality of routine assays, the development of reference materials for a diverse and changing research field such as proteomics represents unique challenges. In order to define common measurement components and common features of typical proteomic samples, the metrology underpinning proteomics must be considered due to the diversity and changing nature of the field. Reference materials can then be designed around common aspects in order to produce reference materials with the broadest applicability. Reference materials are needed to support both qualitative and quantitative proteomic measurements, involving different design considerations. Consensus and validated statistical approaches to describe the confidence in qualitative measurement, such as protein identification, needs to be established. Common sources of measurement bias also need to be considered in proteomic reference material design.


Subject(s)
Proteome/standards , Humans , Mass Spectrometry , Reference Standards
14.
Pathology ; 42(5): 402-8, 2010.
Article in English | MEDLINE | ID: mdl-20632814

ABSTRACT

The laboratory measurement of cardiac troponin (cTn) concentration is a critical tool in the diagnosis of acute myocardial infarction (MI). Current cTnI assays produce different absolute troponin numbers and use different clinical cut-off values; hence cTnI values cannot be interchanged, with consequent confusion for clinicians. A recent Australian study compared patient results for seven cTnI assays and showed that between-method variation was approximately 2- to 5-fold. A major reason for poor method agreement is the lack of a suitable common reference material for the calibration of cTnI assays by manufacturers. Purified complexed troponin material lacks adequate commutability for all assays; hence a serum-based secondary reference material is required for cTnI with value assignment by a higher order reference measurement procedure. There is considerable debate about how best to achieve comparability of results for heterogeneous analytes such as cTnI, whether it should be via the harmonisation or the standardisation process. Whereas harmonisation depends upon consensus value assignment and uses those commercial methods which give the closest agreement at the time, standardisation comes closer to the true value through a reference measurement system that is based upon long-term calibration traceability. The current paper describes standardisation efforts by the International Federation of Clinical Chemistry and Laboratory Medicine Working Group on Standardization of cTnI (IFCC WG-TNI) to establish a reference immunoassay measurement procedure for cTnI of a higher order than current commercial immunoassay methods and a commutable secondary reference material for cTnI to which companies can reference their calibration materials.


Subject(s)
Clinical Chemistry Tests/standards , Troponin I/blood , Clinical Chemistry Tests/methods , Humans , Immunoassay/methods , Immunoassay/standards , Myocardial Infarction/blood , Myocardial Infarction/diagnosis , Reference Standards , Reproducibility of Results , Sensitivity and Specificity
15.
J. bras. patol. med. lab ; 46(3): 187-206, jun. 2010. tab
Article in Portuguese | LILACS | ID: lil-555842

ABSTRACT

ANTECEDENTES: A excreção urinária de albumina indica lesão nos rins e é reconhecida como fator de risco para a progressão das doenças renal e cardiovascular. A dosagem da albumina urinária chama a atenção sobre a necessidade clínica de relatos de resultados precisos e claramente descritos. O National Kidney Disease Education Program e a Federação Internacional de Química Clínica e Medicina Laboratorial (IFCC) reuniram-se para avaliar o estado atual das questões pré-analíticas, analíticas e pós-analíticas que afetam as dosagens da albumina na urina e para identificar as áreas que necessitam de melhorias. CONTEÚDO: A química da albumina na urina não é completamente compreendida. Diretrizes atuais recomendam a utilização da relação albumina/creatinina (RAC) como substituta para a coleta de amostras cronometradas de urina, frequentemente inadequadas. Os resultados da RAC são afetados pela preparação do paciente, pela hora do dia da coleta das amostras e não é padronizada. Foram relatadas consideráveis diferenças intermétodos para a dosagem tanto de albumina quanto de creatinina, mas a verdade é desconhecida, porque não existem procedimentos de referência para a dosagem de albumina e não há materiais de referência para qualquer um desses analitos na urina. Os intervalos de referência recomendados para a RAC não consideram as grandes diferenças intergrupos na excreção da creatinina (por exemplo, relacionadas com diferenças em idade, sexo e etnia), nem o aumento contínuo no risco relacionado com a excreção de albumina. DISCUSSÃO: Necessidades clínicas foram identificadas para a padronização de (a) métodos de coleta da urina, (b) dosagens de albumina e de creatinina na urina com base em um sistema de referência completo, (c) relatórios dos resultados dos testes e (d) intervalos de referência para a RAC.


BACKGROUND: Urinary excretion of albumin indicates kidney damage and is recognized as a risk factor for progression of kidney disease and cardiovascular disease. The role of urinary albumin measurements has focused attention on the clinical need for accurate and clearly reported results. The National Kidney Disease Education Program and the IFCC convened a conference to assess the current state of preanalytical, analytical, and postanalytical issues affecting urine albumin measurements and to identify areas needing improvement. CONTENT: The chemistry of albumin in urine is incompletely understood. Current guidelines recommend the use of the albumin/creatinine ratio (ACR) as a surrogate for the error-prone collection of timed urine samples. Although ACR results are affected by patient preparation and time of day of sample collection, neither is standardized. Considerable intermethod differences have been reported for both albumin and creatinine measurement, but trueness is unknown because there are no reference measurement procedures for albumin and no reference materials for either analyte in urine. The recommended reference intervals for the ACR do not take into account the large intergroup differences in creatinine excretion (e.g., related to differences in age, sex, and ethnicity) nor the continuous increase in risk related to albumin excretion. DISCUSSION: Clinical needs have been identified for standardization of (a) urine collection methods, (b) urine albumin and creatinine measurements based on a complete reference system, (c) reporting of test results, and (d) reference intervals for the ACR.

16.
Anal Bioanal Chem ; 397(2): 511-9, 2010 May.
Article in English | MEDLINE | ID: mdl-20238103

ABSTRACT

An isotope-dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) measurement procedure was developed to accurately quantify amino acid concentrations in National Institute of Standards and Technology (NIST) Standard Reference Material (SRM) 2389a-amino acids in 0.1 mol/L hydrochloric acid. Seventeen amino acids were quantified using selected reaction monitoring on a triple quadrupole mass spectrometer. LC-MS/MS results were compared to gravimetric measurements from the preparation of SRM 2389a-a reference material developed at NIST and intended for use in intra-laboratory calibrations and quality control. Quantitative mass spectrometry results and gravimetric values were statistically combined into NIST-certified mass fraction values with associated uncertainty estimates. Coefficients of variation (CV) for the repeatability of the LC-MS/MS measurements among amino acids ranged from 0.33% to 2.7% with an average CV of 1.2%. Average relative expanded uncertainty of the certified values including Types A and B uncertainties was 3.5%. Mean accuracy of the LC-MS/MS measurements with gravimetric preparation values agreed to within |1.1|% for all amino acids. NIST SRM 2389a will be available for characterization of routine methods for amino acid analysis and serves as a standard for higher-order measurement traceability. This is the first time an ID LC-MS/MS methodology has been applied for quantifying amino acids in a NIST SRM material.


Subject(s)
Amino Acids/analysis , Amino Acids/standards , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Hydrochloric Acid/chemistry , Indicator Dilution Techniques , Isotopes/analysis , Reference Standards , Sensitivity and Specificity , Solutions/chemistry
17.
Mol Cell Proteomics ; 9(2): 225-41, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19837981

ABSTRACT

A major unmet need in LC-MS/MS-based proteomics analyses is a set of tools for quantitative assessment of system performance and evaluation of technical variability. Here we describe 46 system performance metrics for monitoring chromatographic performance, electrospray source stability, MS1 and MS2 signals, dynamic sampling of ions for MS/MS, and peptide identification. Applied to data sets from replicate LC-MS/MS analyses, these metrics displayed consistent, reasonable responses to controlled perturbations. The metrics typically displayed variations less than 10% and thus can reveal even subtle differences in performance of system components. Analyses of data from interlaboratory studies conducted under a common standard operating procedure identified outlier data and provided clues to specific causes. Moreover, interlaboratory variation reflected by the metrics indicates which system components vary the most between laboratories. Application of these metrics enables rational, quantitative quality assessment for proteomics and other LC-MS/MS analytical applications.


Subject(s)
Chromatography, Liquid/methods , Chromatography, Liquid/standards , Proteomics/methods , Proteomics/standards , Tandem Mass Spectrometry/methods , Tandem Mass Spectrometry/standards , Animals , Chickens , Egg Proteins/analysis , Laboratories , Proteome/analysis , Reproducibility of Results , Saccharomyces cerevisiae/metabolism , Saccharomyces cerevisiae Proteins/analysis , Software
18.
Mol Cell Proteomics ; 9(2): 242-54, 2010 Feb.
Article in English | MEDLINE | ID: mdl-19858499

ABSTRACT

Optimal performance of LC-MS/MS platforms is critical to generating high quality proteomics data. Although individual laboratories have developed quality control samples, there is no widely available performance standard of biological complexity (and associated reference data sets) for benchmarking of platform performance for analysis of complex biological proteomes across different laboratories in the community. Individual preparations of the yeast Saccharomyces cerevisiae proteome have been used extensively by laboratories in the proteomics community to characterize LC-MS platform performance. The yeast proteome is uniquely attractive as a performance standard because it is the most extensively characterized complex biological proteome and the only one associated with several large scale studies estimating the abundance of all detectable proteins. In this study, we describe a standard operating protocol for large scale production of the yeast performance standard and offer aliquots to the community through the National Institute of Standards and Technology where the yeast proteome is under development as a certified reference material to meet the long term needs of the community. Using a series of metrics that characterize LC-MS performance, we provide a reference data set demonstrating typical performance of commonly used ion trap instrument platforms in expert laboratories; the results provide a basis for laboratories to benchmark their own performance, to improve upon current methods, and to evaluate new technologies. Additionally, we demonstrate how the yeast reference, spiked with human proteins, can be used to benchmark the power of proteomics platforms for detection of differentially expressed proteins at different levels of concentration in a complex matrix, thereby providing a metric to evaluate and minimize pre-analytical and analytical variation in comparative proteomics experiments.


Subject(s)
Chromatography, Liquid/methods , Chromatography, Liquid/standards , Clinical Laboratory Techniques/standards , Mass Spectrometry/methods , Mass Spectrometry/standards , Saccharomyces cerevisiae Proteins/analysis , Saccharomyces cerevisiae/metabolism , Biomarkers/metabolism , Humans , Proteomics/standards
19.
J Proteome Res ; 9(2): 761-76, 2010 Feb 05.
Article in English | MEDLINE | ID: mdl-19921851

ABSTRACT

The complexity of proteomic instrumentation for LC-MS/MS introduces many possible sources of variability. Data-dependent sampling of peptides constitutes a stochastic element at the heart of discovery proteomics. Although this variation impacts the identification of peptides, proteomic identifications are far from completely random. In this study, we analyzed interlaboratory data sets from the NCI Clinical Proteomic Technology Assessment for Cancer to examine repeatability and reproducibility in peptide and protein identifications. Included data spanned 144 LC-MS/MS experiments on four Thermo LTQ and four Orbitrap instruments. Samples included yeast lysate, the NCI-20 defined dynamic range protein mix, and the Sigma UPS 1 defined equimolar protein mix. Some of our findings reinforced conventional wisdom, such as repeatability and reproducibility being higher for proteins than for peptides. Most lessons from the data, however, were more subtle. Orbitraps proved capable of higher repeatability and reproducibility, but aberrant performance occasionally erased these gains. Even the simplest protein digestions yielded more peptide ions than LC-MS/MS could identify during a single experiment. We observed that peptide lists from pairs of technical replicates overlapped by 35-60%, giving a range for peptide-level repeatability in these experiments. Sample complexity did not appear to affect peptide identification repeatability, even as numbers of identified spectra changed by an order of magnitude. Statistical analysis of protein spectral counts revealed greater stability across technical replicates for Orbitraps, making them superior to LTQ instruments for biomarker candidate discovery. The most repeatable peptides were those corresponding to conventional tryptic cleavage sites, those that produced intense MS signals, and those that resulted from proteins generating many distinct peptides. Reproducibility among different instruments of the same type lagged behind repeatability of technical replicates on a single instrument by several percent. These findings reinforce the importance of evaluating repeatability as a fundamental characteristic of analytical technologies.


Subject(s)
Chromatography, Liquid/methods , Proteome , Tandem Mass Spectrometry/methods , Reproducibility of Results
20.
Anal Chem ; 81(20): 8610-6, 2009 Oct 15.
Article in English | MEDLINE | ID: mdl-19764742

ABSTRACT

This paper describes the development of a reference measurement procedure to quantify human C-reactive protein (CRP) in serum using affinity techniques prior to tryptic digestion and liquid chromatography-tandem mass spectrometry (LC-MS/MS) for the certification of reference materials in clinically relevant ranges. The absence of a suitable internal standard for the CRP measurement, necessary to eliminate potential measurement bias in both the affinity purification and trypsin digestion steps, was addressed using the method of standard addition. The standard addition quantification approach was combined with affinity purification, using an anti-CRP monoclonal antibody conjugated to polystyrene beads, trypsin digestion of the purified protein, and LC-MS/MS analysis of CRP tryptic peptides. The effectiveness of intact protein affinity purification was evaluated through the measurement of CRP in several serum-based CRP control materials, yielding levels that were comparable to their expected mean concentration values. Quantitative results were confirmed with an external calibration approach. This study demonstrates the feasibility of affinity purification with LC-MS/MS for the reference measurement procedure development of low abundance serum protein analytes.


Subject(s)
Blood Chemical Analysis/standards , C-Reactive Protein/analysis , Amino Acid Sequence , Blood Chemical Analysis/methods , C-Reactive Protein/isolation & purification , Chromatography, Liquid , Humans , Indicators and Reagents/chemistry , Reference Standards , Tandem Mass Spectrometry
SELECTION OF CITATIONS
SEARCH DETAIL
...