1.
BJOG ; 124 Suppl 4: 10-18, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28940873

ABSTRACT

OBJECTIVE: To investigate (1) the placement of the BD Odon Device on the model fetal head and (2) perineal distention during simulated operative vaginal births conducted with the BD Odon Device. DESIGN: Observational simulation study. SETTING: North Bristol NHS Trust, UK. POPULATION OR SAMPLE: Four hundred and forty simulated operative vaginal births. METHODS: Three bespoke fetal mannequins were developed to represent (1) bi-parietal diameter of the 50th centile at term, (2) bi-parietal diameter at the 5th centile at term, and (3) 50th centile head with 2 cm of caput. Siting of the BD Odon Device on model heads was determined before and after 400 simulated operative vaginal births. Variables were analysed to determine their effect on device siting and movement during birth. The fetal mannequins were placed inside a maternal mannequin and the BD Odon Device was placed around the fetal head as per the instructions for use. The location of the air cuff was determined before and after the head was delivered. Perineal distension was determined by recording maximum perineal distention during a simulated operative vaginal birth using the same procedure, as well as scenarios employing an inappropriately non-deflated air cuff (for the BD Odon Device), the Kiwi ventouse and non-rotational forceps. MAIN OUTCOME MEASURES: Site and displacement during birth of the BD Odon Device on a model head. Maximal perineal distension during birth. RESULTS: The BD Odon Device was reliably sited in a standard over the fetal head position (approximately 40 mm above the fetal chin) for all stations, head sizes and positions with no significant displacement. In occipito-posterior births, compared with occipito-anterior or transverse, the BD Odon Device routinely sited further down the fetal head (toward the chin). The BD Odon Device was not associated with more perineal distension compared with forceps or Kiwi ventouse (respectively 21, 26 and 21 mm at posterior fourchette). CONCLUSIONS: The BD Odon Device reliably sited over a safe area of the fetal head in 400 simulated births representative of clinical practice. The BD Odon Device generates similar levels of perineal distension compared with Kiwi ventouse when used correctly. TWEETABLE ABSTRACT: Location of the BD Odon Device on a fetal head in simulation.


Subject(s)
Extraction, Obstetrical/instrumentation , Labor Presentation , Perineum/physiology , Extraction, Obstetrical/methods , Female , Fetus/physiology , Head/physiology , Humans , Manikins , Pregnancy
2.
BJOG ; 124 Suppl 4: 19-25, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28940875

ABSTRACT

OBJECTIVE: To determine the pressure and traction forces exerted on a model fetal head by the BD Odon Device, forceps and Kiwi ventouse during simulated births. DESIGN: Simulation study. SETTING: Simulated operative vaginal birth. POPULATION OR SAMPLE: Eighty-four simulated operative vaginal births. METHODS: A bespoke fetal mannequin with pressure sensors around the head and strain gauge across the neck was used to investigate pressure applied over the head, and traction across the neck during 84 simulated births using the BD Odon Device, non-rotational forceps and Kiwi ventouse. MAIN OUTCOME MEASURES: Peak pressure on the fetal face and lateral aspects of the head during correct use of the BD Odon Device and forceps. Peak pressure on orbits and neck during misplacement of the BD Odon Device and forceps. Peak traction force generated until instrument failure using the BD Odon Device, forceps and Kiwi ventouse. RESULTS: When correctly sited and using 80 kPa inflation pressure on the cuff, the BD Odon Device generated a lower peak pressure on the fetal head than forceps (83 versus 146 kPa). When instruments were purposefully misplaced over the orbits, the BD Odon Device generated a lower peak pressure on the orbits compared with forceps (70 versus 123 kPa). When purposefully misplaced over the neck, the BD Odon Device, compared with forceps, generated a greater peak pressure on the anterio-lateral aspect of the neck (56 versus 17 kPa) and a lower peak pressure on the posterior aspect of the neck (76 versus 93 kPa) than forceps. In cases of true cephalic disproportion, the BD Odon Device 'popped-off' at a lower traction force than did forceps (208 versus 270 N). CONCLUSIONS: In simulated assisted vaginal birth with correctly placed instruments, the peak pressure exerted on the fetal head by a BD Odon Device is lower than the pressure exerted by non-rotational forceps. In cases in which delivery of the fetal head is not possible due to cephalo-pelvic disproportion, lower traction forces could be applied using the BD Odon Device than with forceps before the procedure was abandoned due to device failure. TWEETABLE ABSTRACT: BD Odon Device exerts less pressure on a model fetal head than forceps, but more than Kiwi ventouse.


Subject(s)
Extraction, Obstetrical/instrumentation , Fetus/physiology , Head/physiology , Pressure , Extraction, Obstetrical/methods , Female , Humans , Labor Presentation , Manikins , Obstetrical Forceps , Pregnancy , Traction , Vacuum Extraction, Obstetrical/instrumentation