Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
Add more filters










Publication year range
1.
Proc Natl Acad Sci U S A ; 121(23): e2400727121, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38819998

ABSTRACT

Understanding the interplay between charge, nematic, and structural ordering tendencies in cuprate superconductors is critical to unraveling their complex phase diagram. Using pump-probe time-resolved resonant X-ray scattering on the (0 0 1) Bragg peak at the Cu [Formula: see text] and O [Formula: see text] resonances, we investigate nonequilibrium dynamics of [Formula: see text] nematic order and its association with both charge density wave (CDW) order and lattice dynamics in La[Formula: see text]Eu[Formula: see text]Sr[Formula: see text]CuO[Formula: see text]. The orbital selectivity of the resonant X-ray scattering cross-section allows nematicity dynamics associated with the planar O 2[Formula: see text] and Cu 3[Formula: see text] states to be distinguished from the response of anisotropic lattice distortions. A direct time-domain comparison of CDW translational-symmetry breaking and nematic rotational-symmetry breaking reveals that these broken symmetries remain closely linked in the photoexcited state, consistent with the stability of CDW topological defects in the investigated pump fluence regime.

2.
Struct Dyn ; 9(5): 054302, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36276194

ABSTRACT

X-ray free electron laser experiments have brought unique capabilities and opened new directions in research, such as creating new states of matter or directly measuring atomic motion. One such area is the ability to use finely spaced sets of coherent x-ray pulses to be compared after scattering from a dynamic system at different times. This enables the study of fluctuations in many-body quantum systems at the level of the ultrafast pulse durations, but this method has been limited to a select number of examples and required complex and advanced analytical tools. By applying a new methodology to this problem, we have made qualitative advances in three separate areas that will likely also find application to new fields. As compared to the "droplet-type" models, which typically are used to estimate the photon distributions on pixelated detectors to obtain the coherent x-ray speckle patterns, our algorithm achieves an order of magnitude speedup on CPU hardware and two orders of magnitude improvement on GPU hardware. We also find that it retains accuracy in low-contrast conditions, which is the typical regime for many experiments in structural dynamics. Finally, it can predict photon distributions in high average-intensity applications, a regime which up until now has not been accessible. Our artificial intelligence-assisted algorithm will enable a wider adoption of x-ray coherence spectroscopies, by both automating previously challenging analyses and enabling new experiments that were not otherwise feasible without the developments described in this work.

3.
Angew Chem Int Ed Engl ; 57(6): 1474-1479, 2018 02 05.
Article in English | MEDLINE | ID: mdl-29230942

ABSTRACT

The cerium density and valence in micrometer-size platinum-supported cerium-zirconium oxide Pt/Ce2 Zr2 Ox (x=7-8) three-way catalyst particles were successfully mapped by hard X-ray spectro-ptychography (ptychographic-X-ray absorption fine structure, XAFS). The analysis of correlation between the Ce density and valence in ptychographic-XAFS images suggested the existence of several oxidation behaviors in the oxygen storage process in the Ce2 Zr2 Ox particles. Ptychographic-XAFS will open up the nanoscale chemical imaging and structural analysis of heterogeneous catalysts.

4.
Opt Express ; 25(8): 8593-8603, 2017 Apr 17.
Article in English | MEDLINE | ID: mdl-28437937

ABSTRACT

Coherent diffraction imaging (CDI) is a method for reconstructing the complex-valued image of an object from diffraction intensities by using iterative phasing methods. X-ray ptychography is a scanning type of CDI using X-rays, allowing us to visualize the complex transmission function of an extended specimen. We here propose the use of the Kramers-Kronig relation (KKR) as an additional constraint in phase retrieval algorithms for multiple-energy X-ray ptychography using the absorption edge of a specific element. A numerical simulation showed that the speed of convergence was increased by using the improved algorithm with the KKR. We successfully demonstrated its usefulness in a proof-of-principle experiment at SPring-8. The present algorithm is particularly useful for imaging X-ray absorption fine structures of a specific element buried within thick samples by hard X-ray spectro-ptychography.

5.
Sci Rep ; 6: 35060, 2016 10 13.
Article in English | MEDLINE | ID: mdl-27734961

ABSTRACT

The phase shift of light or electrons in objects is now necessary for probing weak-phase objects such as unstained biological specimens. Optical microscopy (OM) and transmission electron microscopy (TEM) have been used to observe weak-phase objects. However, conventional OM has low spatial resolution and TEM is limited to thin specimens. Here, we report on the development of dark-field X-ray ptychography, which combines X-ray ptychography and X-ray in-line holography, to observe weak-phase objects with a phase resolution better than 0.01 rad, a spatial resolution better than 15 nm, and a field of view larger than 5 µm. We apply this method to the observation of both the outline and magnetosomes of the magnetotactic bacteria MO-1. Observation of thick samples with high resolution is expected to find broad applications in not only biology but also materials science.


Subject(s)
Bacteria/ultrastructure , Holography , Image Processing, Computer-Assisted , Microscopy , Microscopy, Electron, Transmission , Radiography , X-Rays
6.
Opt Express ; 24(11): 11917-25, 2016 May 30.
Article in English | MEDLINE | ID: mdl-27410114

ABSTRACT

The sample size must be less than the diffraction-limited focal spot size of the incident beam in single-shot coherent X-ray diffraction imaging (CXDI) based on a diffract-before-destruction scheme using X-ray free electron lasers (XFELs). This is currently a major limitation preventing its wider applications. We here propose multiple defocused CXDI, in which isolated objects are sequentially illuminated with a divergent beam larger than the objects and the coherent diffraction pattern of each object is recorded. This method can simultaneously reconstruct both objects and a probe from the coherent X-ray diffraction patterns without any a priori knowledge. We performed a computer simulation of the prposed method and then successfully demonstrated it in a proof-of-principle experiment at SPring-8. The prposed method allows us to not only observe broad samples but also characterize focused XFEL beams.

7.
Opt Express ; 23(5): 5452-67, 2015 Mar 09.
Article in English | MEDLINE | ID: mdl-25836778

ABSTRACT

Coherent X-ray Diffraction Imaging (CDI) and X-ray ptychography both heavily rely on the high degree of spatial coherence of the X-ray illumination for sufficient experimental data quality for reconstruction convergence. Nevertheless, the majority of the available synchrotron undulator sources have a limited degree of partial coherence, leading to reduced data quality and a lower speckle contrast in the coherent diffraction patterns. It is still an open question whether experimentalists should compromise the coherence properties of an X-ray source in exchange for a higher flux density at a sample, especially when some materials of scientific interest are relatively weak scatterers. A previous study has suggested that in CDI, the best strategy for the study of strong phase objects is to maintain a high degree of coherence of the illuminating X-rays because of the broadening of solution space resulting from the strong phase structures. In this article, we demonstrate the first systematic analysis of the effectiveness of partial coherence correction in ptychography as a function of the coherence properties, degree of complexity of illumination (degree of phase diversity of the probe) and sample phase complexity. We have also performed analysis of how well ptychographic algorithms refine X-ray probe and complex coherence functions when those variables are unknown at the start of reconstructions, for noise-free simulated data, in the case of both real-valued and highly-complex objects.

8.
Opt Express ; 22(9): 10294-303, 2014 May 05.
Article in English | MEDLINE | ID: mdl-24921732

ABSTRACT

X-ray ptychography, a scanning coherent diffraction imaging method, was used to reconstruct images of a "Siemens star" test pattern with amplitude and phase contrast. While studying how the use of illumination with an increased bandwidth results in clear improvements in the quality of image reconstructions, we found that an artificial change in the overall distance scale factor of the algorithm leads to a systematic response in the image, which is reproduced with an incorrect number of spokes. This pathology is explained by the conflict between the length scales set by the scan and by the diffraction patterns on the detector.

9.
Sci Rep ; 3: 1177, 2013.
Article in English | MEDLINE | ID: mdl-23378910

ABSTRACT

Artificially structured coatings are widely employed to minimize materials deterioration and corrosion, the annual direct cost of which is over 3% of the gross domestic product (GDP) for industrial countries. Manufacturing higher performance anticorrosive coatings is one of the most efficient approaches to reduce this loss. However, three-dimensional (3D) structure of coatings, which determines their performance, has not been investigated in detail. Here we present a quantitative nano-scale analysis of the 3D spatial structure of an anticorrosive aluminium epoxy barrier marine coating obtained by serial block-face scanning electron microscopy (SBFSEM) and ptychographic X-ray computed tomography (PXCT). We then use finite element simulations to demonstrate how percolation through this actual 3D structure impedes ion diffusion in the composite materials. We found the aluminium flakes align within 15° of the coating surface in the material, causing the perpendicular diffusion resistance of the coating to be substantially higher than the pure epoxy.

10.
Opt Express ; 20(21): 24038-48, 2012 Oct 08.
Article in English | MEDLINE | ID: mdl-23188371

ABSTRACT

A scanning coherent diffraction imaging method was used to reconstruct the X-ray wavefronts produced by a Fresnel zone plate (FZP) and by Kirkpatrick-Baez (KB) focusing mirrors. The ptychographical measurement was conducted repeatedly by placing a lithographed test sample at different defocused planes. The wavefronts, recovered by phase-retrieval at well-separated planes, show good consistency with numerical propagation results, which provides a self-verification. The validity of the obtained FZP wavefront was further confirmed with theoretical predictions.


Subject(s)
Lenses , Refractometry/instrumentation , X-Rays , Equipment Design , Equipment Failure Analysis
11.
Opt Express ; 18(22): 23488-94, 2010 Oct 25.
Article in English | MEDLINE | ID: mdl-21164691

ABSTRACT

The effect of the spot diameter in nanosecond excimer laser percussion drilling of through via in silicon wafer is presented. Experimental results show a ten fold increase of the ablation efficiency when decreasing the spot diameter from 220 µm to 9 µm at constant fluence in the range 7.5 J/cm(2) to 13.2 J/cm(2). Such effect is absent when using 60 ps deep-UV laser pulses. A model is developed that explain the findings in terms of plume shielding effect on the laser pulse. The model is successfully applied also on previously published data on deep-UV laser drilling of Polyamide and Alumina.

SELECTION OF CITATIONS
SEARCH DETAIL
...