Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
J Acoust Soc Am ; 154(2): 751-762, 2023 08 01.
Article in English | MEDLINE | ID: mdl-37556566

ABSTRACT

Web-based testing is an appealing option for expanding psychoacoustics research outside laboratory environments due to its simple logistics. For example, research participants partake in listening tasks using their own computer and audio hardware and can participate in a comfortable environment of their choice at their own pace. However, it is unknown how deviations from conventional in-lab testing affect data quality, particularly in binaural hearing tasks that traditionally require highly precise audio presentation. Here, we used an online platform to replicate two published in-lab experiments: lateralization to interaural time and level differences (ITD and ILD, experiment I) and dichotic and contralateral unmasking of speech (experiment II) in normal-hearing (NH) young adults. Lateralization data collected online were strikingly similar to in-lab results. Likewise, the amount of unmasking measured online and in-lab differed by less than 1 dB, although online participants demonstrated higher speech reception thresholds overall than those tested in-lab by up to ∼7 dB. Results from online participants who completed a hearing screening versus those who self-reported NH did not differ significantly. We conclude that web-based psychoacoustics testing is a viable option for assessing binaural hearing abilities among young NH adults and discuss important considerations for online study design.


Subject(s)
Speech Perception , Young Adult , Humans , Psychoacoustics , Hearing , Auditory Perception , Internet
2.
Front Neurosci ; 16: 1038856, 2022.
Article in English | MEDLINE | ID: mdl-36570844

ABSTRACT

Introduction: Bilateral cochlear implants (BiCIs) can facilitate improved speech intelligibility in noise and sound localization abilities compared to a unilateral implant in individuals with bilateral severe to profound hearing loss. Still, many individuals with BiCIs do not benefit from binaural hearing to the same extent that normal hearing (NH) listeners do. For example, binaural redundancy, a speech intelligibility benefit derived from having access to duplicate copies of a signal, is highly variable among BiCI users. Additionally, patients with hearing loss commonly report elevated listening effort compared to NH listeners. There is some evidence to suggest that BiCIs may reduce listening effort compared to a unilateral CI, but the limited existing literature has not shown this consistently. Critically, no studies to date have investigated this question using pupillometry to quantify listening effort, where large pupil sizes indicate high effort and small pupil sizes indicate low effort. Thus, the present study aimed to build on existing literature by investigating the potential benefits of BiCIs for both speech intelligibility and listening effort. Methods: Twelve BiCI adults were tested in three listening conditions: Better Ear, Poorer Ear, and Bilateral. Stimuli were IEEE sentences presented from a loudspeaker at 0° azimuth in quiet. Participants were asked to repeat back the sentences, and responses were scored by an experimenter while changes in pupil dilation were measured. Results: On average, participants demonstrated similar speech intelligibility in the Better Ear and Bilateral conditions, and significantly worse speech intelligibility in the Poorer Ear condition. Despite similar speech intelligibility in the Better Ear and Bilateral conditions, pupil dilation was significantly larger in the Bilateral condition. Discussion: These results suggest that the BiCI users tested in this study did not demonstrate binaural redundancy in quiet. The large interaural speech asymmetries demonstrated by participants may have precluded them from obtaining binaural redundancy, as shown by the inverse relationship between the two variables. Further, participants did not obtain a release from effort when listening with two ears versus their better ear only. Instead, results indicate that bilateral listening elicited increased effort compared to better ear listening, which may be due to poor integration of asymmetric inputs.

3.
Trends Hear ; 25: 23312165211013256, 2021.
Article in English | MEDLINE | ID: mdl-34024219

ABSTRACT

The measurement of pupil dilation has become a common way to assess listening effort. Pupillometry data are subject to artifacts, requiring highly contaminated data to be discarded from analysis. It is unknown how trial exclusion criteria impact experimental results. The present study examined the effect of a common exclusion criterion, percentage of blinks, on speech intelligibility and pupil dilation measures in 9 participants with single-sided deafness (SSD) and 20 participants with normal hearing. Participants listened to and repeated sentences in quiet or with speech maskers. Pupillometry trials were processed using three levels of blink exclusion criteria: 15%, 30%, and 45%. These percentages reflect a threshold for missing data points in a trial, where trials that exceed the threshold are excluded from analysis. Results indicated that pupil dilation was significantly greater and intelligibility was significantly lower in the masker compared with the quiet condition for both groups. Across-group comparisons revealed that speech intelligibility in the SSD group decreased significantly more than the normal hearing group from quiet to masker conditions, but the change in pupil dilation was similar for both groups. There was no effect of blink criteria on speech intelligibility or pupil dilation results for either group. However, the total percentage of blinks in the masker condition was significantly greater than in the quiet condition for the SSD group, which is consistent with previous studies that have found a relationship between blinking and task difficulty. This association should be carefully considered in future experiments using pupillometry to gauge listening effort.


Subject(s)
Deafness , Speech Perception , Data Analysis , Hearing , Humans , Noise , Pupil
4.
Trends Hear ; 24: 2331216520946983, 2020.
Article in English | MEDLINE | ID: mdl-32812515

ABSTRACT

The ability to attend to target speech in background noise is an important skill, particularly for children who spend many hours in noisy environments. Intelligibility improves as a result of spatial or binaural unmasking in the free-field for normal-hearing children; however, children who use bilateral cochlear implants (BiCIs) demonstrate little benefit in similar situations. It was hypothesized that poor auditory attention abilities might explain the lack of unmasking observed in children with BiCIs. Target and interferer speech stimuli were presented to either or both ears of BiCI participants via their clinical processors. Speech reception thresholds remained low when the target and interferer were in opposite ears, but they did not show binaural unmasking when the interferer was presented to both ears and the target only to one ear. These results demonstrate that, in the most extreme cases of stimulus separation, children with BiCIs can ignore an interferer and attend to target speech, but there is weak or absent binaural unmasking. It appears that children with BiCIs mostly experience poor encoding of binaural cues rather than deficits in ability to selectively attend to target speech.


Subject(s)
Cochlear Implantation , Cochlear Implants , Sound Localization , Speech Perception , Attention , Child , Humans , Speech
SELECTION OF CITATIONS
SEARCH DETAIL
...