Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 44
Filter
1.
Cartilage ; 14(4): 407-412, 2023 12.
Article in English | MEDLINE | ID: mdl-37496261

ABSTRACT

OBJECTIVE: The present study aims to compare the presence and severity of patellofemoral osteoarthritis between patients with root lesions and non-root lesions. DESIGN: A total of 102 patients were included in this study (51 root lesions and 51 non-root lesions). The root lesion cohort was matched to a non-root lesion cohort based on sex, body mass index, and age at the time of surgery. Radiographic evaluation with modified Outerbridge scoring of MRI of the knee was performed to determine the severity of degeneration of the knee joint preoperatively. Mann-Whitney and Independent t tests were used to compare the groups. RESULTS: The root lesion group had statistically greater Outerbridge patella scores (M = 2.45 ± 1.12) and trochlear scores (M = 2.27 ± 1.37) than the non-root lesion patients (M = 1.78 ± 1.30, P = 0.006, and M = 1.55 ± 1.40, P = 0.010, respectively). When using a new scale for grading patellofemoral arthritis, the root lesion group had statistically greater scores (M = 8.33 ± 3.38) than the non-root lesion patients (M = 5.67 ± 3.07) (P < 0.001). CONCLUSION: Patients with root lesions have a greater degree of patellofemoral cartilage lesions than patients without root lesions. The presence of cartilage lesions preoperatively in root lesion patients has presented the question of whether repair is worthwhile or if one should delay surgery until arthroplasty is indicated. Future research should be carried out on outcomes of root repair surgery in patients with patellofemoral cartilage lesions, in addition to considering the patient's age, activity level, and other risk factors.


Subject(s)
Knee Joint , Osteoarthritis, Knee , Humans , Knee Joint/surgery , Menisci, Tibial/surgery , Osteoarthritis, Knee/diagnostic imaging , Osteoarthritis, Knee/pathology , Knee/pathology , Magnetic Resonance Imaging
2.
JBJS Case Connect ; 13(2)2023 04 01.
Article in English | MEDLINE | ID: mdl-37053362

ABSTRACT

CASE: A 65-year-old man with osteoarthritis of the hip developed a soft-tissue mass of the inferior gluteal region 3 years after metal-on-metal resurfacing hip arthroplasty. Clinical and imaging findings suggested an adverse local tissue reaction. Intraoperatively, nearly 1 liter of intra-articular fibrinous loose bodies (rice bodies) was removed, and histology showed features of an adaptive immune response. The patient had no evidence of an autoimmune disease or mycobacterial infection. CONCLUSION: To our knowledge, this is the first reported case of florid rice bodies associated with a metal-on-metal hip arthroplasty and adverse local tissue reaction.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Osteoarthritis, Hip , Male , Humans , Aged , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods , Hip Prosthesis/adverse effects , Prosthesis Design , Osteoarthritis, Hip/etiology , Metals
3.
Hand (N Y) ; 18(4): 553-561, 2023 06.
Article in English | MEDLINE | ID: mdl-34963371

ABSTRACT

BACKGROUND: When patients with systemic sclerosis (SSc) and systemic lupus erythematosus (SLE) develop digital ischemia, conventional angiography (CA) is traditionally used to assess hand vasculature. Recently, Chang et al described an angiographic classification system for patients with SSc. Conventional angiography uses intravascular contrast agents that are nephrotoxic and vasoconstrictive. Owing to these limitations, this study assesses the use of contrast-enhanced magnetic resonance angiography (MRA) as an alternative to CA to evaluate hand vasculature in patients with digital ischemia. METHODS: This retrospective case series reports on 38 contrast-enhanced MRAs of hand vasculature from 30 symptomatic patients with SSc (N = 21) or SLE (N = 9). The radial and ulnar arteries (RA, UA) and the superficial and deep palmar arches were evaluated at standard reference points both quantitatively and qualitatively for their diameter, patency, and Chang classification. RESULTS: In SSc MRAs (n = 26), the UA was significantly smaller than the RA and was occluded in 46%. In SLE MRAs (n = 12), the UA and RA had no difference in diameter and the UA was occluded in 25%. In SSc, the most common Chang classification was type 2 (UA involvement) in 44%. In SLE, the most common Chang classification was type 4 (UA and RA involvement) in 45%, with 18% classified as type 2. CONCLUSIONS: Contrast-enhanced MRA used to assess hand vasculature in SSc patients with digital ischemia shows similar patterns of vascular involvement as previously demonstrated by CA. While vascular involvement in SSc predominantly involves the UA, the RA is also frequently involved in SLE.


Subject(s)
Lupus Erythematosus, Systemic , Scleroderma, Systemic , Humans , Retrospective Studies , Magnetic Resonance Angiography , Scleroderma, Systemic/complications , Scleroderma, Systemic/diagnostic imaging , Lupus Erythematosus, Systemic/complications , Lupus Erythematosus, Systemic/diagnostic imaging , Ischemia/diagnostic imaging , Ischemia/etiology
4.
Magn Reson Imaging ; 96: 108-115, 2023 02.
Article in English | MEDLINE | ID: mdl-36496096

ABSTRACT

BACKGROUND: Conventional quantitative diffusion-weighted imaging (DWI) is sensitive to changes in tissue microstructure, but its application to evaluating patients with orthopaedic hardware has generally been limited due to metallic susceptibility artifacts. The apparent diffusion coefficient (ADC) and T2-values from a multi-spectral imaging (MSI) DWI combined with 2D multi-spectral imaging with a 2D periodically rotated overlapping parallel lines with enhanced reconstruction (2D-MSI PROPELLER DWI) based sequence and a MAVRIC based T2 mapping sequence, respectively, may mitigate the artifact and provide additional quantitative information on synovial reactions in individuals with total hip arthroplasty (THA). The aim of this pilot study is to utilize a 2D-MSI PROPELLER DWI and a MAVRIC-based T2 mapping to evaluate ADC and T2-values of synovial reactions in patients with THA. METHODS: Coronal morphologic MRIs from THA patients underwent evaluation of the synovium and were assigned a synovial classification of 'normal', or 'grouped abnormal' (consisting of sub-groups 'infection', 'polymeric', 'metallosis', 'adverse local tissue reaction' [ALTR], or 'non-specific') and type of synovial reaction present (fluid-like, solid-like, or mixed). Regions of interest (ROIs) were placed in synovial reactions for measurement of ADC and T2-values, obtained from the 2D-MSI PROPELLER DWI and T2-MAVRIC sequences, respectively. A one-way analysis of variance (ANOVA) and Kruskal-Wallis rank sum tests were used to compare the differences in ADC and T2-values across the different synovial reaction classifications. A Kruskal-Wallis test was used to compare the ROI areas for the ADC and T2-values. A principal component analysis (PCA) was performed to evaluate the possible effects of ADC values, size of the ADC ROI, T2-values, and size of the T2 ROI with respect to synovial reaction classification. RESULTS: Differences of ADC and T2 among the individual synovial reactions were not found. A difference of ADC between 'normal' and 'grouped abnormal' synovial reactions was also not detected even as the ADC area of 'grouped abnormal' synovial reactions were significantly larger (p = 0.02). The 'grouped abnormal' synovial reactions had significantly shorter T2-values than 'normal' synovial reactions (p = 0.02), and that the T2 area of 'grouped abnormal' synovial reactions were significantly larger (p = 0.01). A larger ROI area on the T2-maps was observed in the mixed synovial reaction type as compared to the fluid-like reaction type area (p = 0.01). Heterogeneity was noted in calculated ADC and T2 maps. PCA analysis revealed obvious clustering by the 'normal' and 'grouped abnormal' classifications. CONCLUSIONS: 2D-MSI PROPELLER DWI and MAVRIC-T2 generate quantitative images of periprosthetic tissues within clinically feasible scan times. The combination of derived ADC and T2-values with area of synovial reaction may aid in differentiating normal from abnormal synovial reactions between types of synovial reactions in patients with THA.


Subject(s)
Arthroplasty, Replacement, Hip , Humans , Arthroplasty, Replacement, Hip/adverse effects , Pilot Projects , Diffusion Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging/methods , Artifacts
6.
Radiology ; 304(1): 128-136, 2022 07.
Article in English | MEDLINE | ID: mdl-35315718

ABSTRACT

Background Because loosening of total knee arthroplasty (TKA) occurs due to poor osseous integration at component-bone interfaces, interface assessment may be helpful in diagnosing loosening at MRI. Purpose To determine interreader reproducibility for characterizing component interfaces and diagnosing loosening and to evaluate the diagnostic performance of MRI for diagnosing loosening after TKA compared with radiography. Materials and Methods Consecutive knees with TKA that underwent revision between July 2018 and June 2019 and were imaged at MRI and radiography were included in this retrospective study. Interface type (normal, fibrous membrane, fluid, or osteolysis), percent integration (<33%, 33%-66%, or >66%), and presence of bone marrow edema pattern were assessed. Loosening was diagnosed at MRI if no or almost no normal interface was present. Sensitivity and specificity were compared with radiographs by using surgical findings as reference. Gwet agreement coefficient evaluated interreader reproducibility between two readers and multivariable logistic regression assessed risk factors for loosening. Results Among 116 knees in 114 patients (mean age, 63 years ± 10 [SD]; 59 women), 61 of 116 knees (52.6%) had at least one loose component. Interreader reproducibility of MRI was substantial to excellent (Gwet agreement coefficient, 0.67-0.96). Loosening was associated with fluid interface (odds ratio [OR], 20.1; 95% CI: 5.7, 70.9) or osteolysis (OR, 3.1; 95% CI: 1.8, 5.3), absence of any normal interface (OR, 11.8; 95% CI: 6.3, 22.2), poor (<33%) osseous integration (OR, 20.4; 95% CI: 9.7, 42.6), and bone marrow edema pattern (OR, 4.7; 95% CI: 2.8, 7.8). Sensitivity and specificity of MRI for loosening were 84% (27 of 32; 95% CI: 72, 97) and 85% (71 of 84; 95% CI: 77, 92) for the patellar, 31% (eight of 26; 95% CI: 13, 49) and 100% (90 of 90; 95% CI: 100, 100) for the femoral, and 81% (22 of 27; 95% CI: 66, 96) and 98% (87 of 89; 95% CI: 95, 100) for the tibial component, respectively. MRI had higher sensitivity (84% vs 31%; P < .001) but lower specificity (85% vs 96%; P = .003) for patellar component loosening than did radiography, respectively, whereas no evidence of a difference was found for femoral (sensitivity and specificity, MRI vs radiography: 31% vs 46% [P = .20] and 100% vs 99% [P > .99], respectively) or tibial (sensitivity and specificity, MRI vs radiography: 81% vs 70% [P = .16] and 98% vs 97% [P = .32], respectively) component loosening. Conclusion MRI demonstrated substantial to excellent interreader reproducibility and higher sensitivity than did radiography for diagnosing patellar component loosening after total knee arthroplasty. © RSNA, 2022 Online supplemental material is available for this article.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteolysis , Arthroplasty, Replacement, Knee/adverse effects , Female , Humans , Knee Joint/surgery , Knee Prosthesis/adverse effects , Magnetic Resonance Imaging/adverse effects , Middle Aged , Osteolysis/diagnostic imaging , Prosthesis Failure , Radiography , Reoperation/adverse effects , Reproducibility of Results , Retrospective Studies
7.
HSS J ; 18(1): 91-97, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35087338

ABSTRACT

Background: Sacroiliac (SI) joint subchondral resorption on high-resolution magnetic resonance imaging (MRI) may be an early sign of the development of sacroiliitis. At our institution, high-resolution intermediate-weighted (proton density) MRI sequences are used in the workup of suspected spondyloarthritis (SpA). Questions/Purpose: We sought to test the hypothesis that SI joint subchondral resorption might be a useful MRI feature in the diagnosis of sacroiliitis. Methods: We retrospectively reviewed the records of patients with suspected SpA from a single rheumatologist's practice from January 1, 2010, to December 31, 2017. Patients had an MRI of the SI joints, using our institution's specialized protocol, and underwent standard physical examination and laboratory evaluation. The sensitivity and specificity of SI joint subchondral resorption in the identification of sacroiliitis were estimated using the clinical diagnosis as the reference standard and from a Bayesian latent class model with conditional dependence. Results: SI joint subchondral resorption on SI joint MRI was highly correlated with a positive diagnosis in patients worked up for axial SpA. It demonstrated superior sensitivity when compared with other MRI features used in the MRI diagnosis of sacroiliitis, such as bone marrow edema pattern, erosion, and ankylosis. Interobserver reliability was high for subchondral resorption. Conclusion: This retrospective study found that subchondral resorption on MRI evaluation of the SI joints appeared to be a sensitive indicator of SpA, potentially of early disease. This imaging feature warrants evaluation in other cohorts of patients suspected of having axial SpA to validate diagnostic performance in diverse populations.

8.
Magn Reson Imaging ; 85: 186-192, 2022 01.
Article in English | MEDLINE | ID: mdl-34715288

ABSTRACT

OBJECTIVE: To assess a new deep learning-based MR reconstruction method, "DLRecon," for clinical evaluation of peripheral nerves. METHODS: Sixty peripheral nerves were prospectively evaluated in 29 patients (mean age: 49 ± 16 years, 17 female) undergoing standard-of-care (SOC) MR neurography for clinically suspected neuropathy. SOC-MRIs and DLRecon-MRIs were obtained through conventional and DLRecon reconstruction methods, respectively. Two radiologists randomly evaluated blinded images for outer epineurium conspicuity, fascicular architecture visualization, pulsation artifact, ghosting artifact, and bulk motion. RESULTS: DLRecon-MRIs were likely to score better than SOC-MRIs for outer epineurium conspicuity (OR = 1.9, p = 0.007) and visualization of fascicular architecture (OR = 1.8, p < 0.001) and were likely to score worse for ghosting (OR = 2.8, p = 0.004) and pulsation artifacts (OR = 1.6, p = 0.004). There was substantial to almost-perfect inter-reconstruction method agreement (AC = 0.73-1.00) and fair to almost-perfect interrater agreement (AC = 0.34-0.86) for all features evaluated. DLRecon-MRI had improved interrater agreement for outer epineurium conspicuity (AC = 0.71, substantial agreement) compared to SOC-MRIs (AC = 0.34, fair agreement). In >80% of images, the radiologist correctly identified an image as SOC- or DLRecon-MRI. DISCUSSION: Outer epineurium and fascicular architecture conspicuity, two key morphological features critical to evaluating a nerve injury, were improved in DLRecon-MRIs compared to SOC-MRIs. Although pulsation and ghosting artifacts increased in DLRecon images, image interpretation was unaffected.


Subject(s)
Deep Learning , Adult , Aged , Algorithms , Artifacts , Female , Humans , Magnetic Resonance Imaging/methods , Middle Aged , Peripheral Nerves/diagnostic imaging
9.
HSS J ; 17(2): 165-173, 2021 Jul.
Article in English | MEDLINE | ID: mdl-34421426

ABSTRACT

Background: Hip arthroplasty is increasingly prevalent, and early detection of complications can improve outcomes. Quantitative magnetic resonance imaging (qMRI) methods using multi-acquisition variable-resonance image combination (MAVRIC) may allow for the assessment of soft tissues in close proximity to hip arthroplasty devices. Question/Purposes: We sought to determine the clinical feasibility of MAVRIC-based T2 mapping as a qMRI approach for assessing synovial reactions in patients with a hip arthroplasty device. We hypothesized that there would be differences in T2 metrics by synovial type, clinical impression, and clinical findings related to synovitis. Methods: We conducted a cross-sectional study of 141 subjects with 171 hip arthroplasties with greater than 1 year post-implantation. We enrolled subjects who had had a primary total hip arthroplasty or hip resurfacing arthroplasty between May 2019 and March 2020, excluding those with a revision hip arthroplasty and those with standard safety contraindications for receiving an MRI. Institutional standard 2D fast spin echo (FSE), short-tau inversion recovery (STIR), and susceptibility-reduced MAVRIC morphological MR images were acquired for each hip and followed by a dual-echo acquisition MAVRIC T2 mapping sequence. Results: While 131 subjects (81%) were classified as having a "normal" synovial reaction, significantly longer T2 values were found for fluid synovial reactions compared with mixed reactions. In addition, subjects with synovial dehiscence and decompression present had T2 prolongation. Larger synovial volumes were found in subjects with low-signal intensity deposits. Conclusions: MAVRIC-based T2 mapping is clinically feasible and there are significant quantitative differences based on type of synovial reaction. Patients undergoing hip arthroscopy revision surgery will warrant comparison of T2 values with direct histologic assessment of a tissue sample obtained intraoperatively. The approach used in this study may be used for a quantitative evaluation and monitoring of soft tissues around metal implants.

10.
Clin Orthop Relat Res ; 479(12): 2633-2650, 2021 12 01.
Article in English | MEDLINE | ID: mdl-34232144

ABSTRACT

BACKGROUND: The evaluation of the natural history prevalence of adverse local tissue reactions (ALTRs) using MRI has focused only on metal-on-metal (MoM) bearing surfaces without comparison to nonMoM bearing surfaces. QUESTIONS/PURPOSES: To determine (1) the longitudinal changes and differences in blood metal ion levels in patients with hip resurfacing arthroplasty (HRA), ceramic-on-ceramic (CoC) THA, and metal-on-polyethylene (MoP) THA compared with those undergoing ceramic-on-polyethylene (CoP) THA; (2) how the longitudinal change of synovial reaction classification in patients with HRA, CoC THA, and MoP THA compares with those undergoing CoP THA, and whether there is an association between the presence of an ALTR or metallosis on MRI with corresponding patient-reported outcomes, or the presence of capsular dehiscence; and (3) differences in blood metal ion levels between patients undergoing HRA with an ALTR or metallosis on MRI and those with HRA without these conditions. METHODS: Between March 2014 and February 2019, 22,723 patients underwent primary HRA and THA at one center. Patients received an HRA based on their desired athletic level after surgery and the presence of normal acetabular and proximal femoral bone morphology without osteopenia or osteoporosis. Two percent (342 of 22,723) of patients were contacted to participate, and 71% (243 of 342 hips in 206 patients) were enrolled for analysis at baseline. The patients underwent arthroplasty for degenerative joint disease, and 25 patients withdrew over the course of the study. We included patients who were more than 1 year postarthroplasty. All participants had an MRI examination and blood serum ion testing and completed a Hip Disability and Osteoarthritis Outcome Score survey annually for four years (baseline, year 1, year 2, year 3). Morphologic and susceptibility-reduced MR images were evaluated by a single radiologist not involved in the care of patients for the presence and classification of synovitis (Gwet AC1: 0.65 to 0.97), synovial thickness, and volume (coefficient of repeatability: 1.8 cm3). Linear mixed-effects models were used to compare the mean synovial thickness, synovial volume, and Hip Disability and Osteoarthritis Outcome Score subscales between bearing surfaces at each timepoint and within each bearing surface over time. Marginal Cox proportional hazards models were used to compare the time to and the risk of developing ALTR only, metallosis only, and ALTR or metallosis between bearing surfaces. All models were adjusted for age, sex, BMI, and length of implantation based on known confounders for hip arthroplasty. Adjustment for multiple comparisons was performed using the Dunnett-Hsu method. RESULTS: Patients with unilateral HRA had higher cobalt and chromium serum ion levels (baseline: 1.8 ± 0.8 ppb, year 1: 2.0 ± 1.5 ppb, year 2: 2.1 ± 1.2 ppb, year 3: 1.6 ± 0.7 ppb) than those with unilateral CoP bearings (baseline: 0.0 ± 0.1 ppb, year 1: 0.1 ± 0.3 ppb, year 2: 0.0 ± 0.2 ppb, year 3: 0.0 ± 0.0 ppb) at all timepoints (p < 0.001 for each time point). More patients who received an HRA developed ALTR or metallosis on MRI than did patients with CoP bearings (hazard ratio 4.8 [95% confidence interval 1.2 to 18.4]; p = 0.02). There was no association between the longitudinal change of synovial reaction to ALTR or metallosis on MRI with patient-reported outcomes. In addition, there was no association between the presence of dehiscence at baseline and the subsequent development of ALTR or metallosis, as seen on MRI. There were elevated cobalt (4.7 ± 3.5 ppb) and chromium (4.7 ± 2.6 ppb) serum levels in patients with unilateral HRA who had an ALTR or metallosis present on MRI at year 1 compared with patients without an ALTR or metallosis on MRI (cobalt: 1.8 ± 1.0 ppb, mean difference 4.7 ppb [95% CI 3.3 to 6.0]; p < 0.001; chromium: 2.3 ± 0.5 ppb, mean difference 3.6 ppb [95% CI 2.2 to 5.0]; p < 0.001) as well as for chromium at year 3 (3.9 ± 2.4 ppb versus 2.2 ± 1.1 ppb, mean difference 1.3 ppb [95% CI 0.3 to 2.4]; p = 0.01). CONCLUSION: We found a higher proportion of ALTR or metallosis on MRI in patients with HRA compared with patients with CoP, even when patient self-assessed symptomatology of those with an ALTR or metallosis on MRI was not different than the absence of these features. MRI detected ALTRs in high-function patients, emphasizing that an annual clinical assessment dependent on survey or blood ion testing alone may not detect soft tissue complications. The results of this study are in line with prior consensus recommendations of using MRI as part of a routine follow-up protocol for this patient population. LEVEL OF EVIDENCE: Level III, therapeutic study.


Subject(s)
Foreign-Body Reaction/epidemiology , Hip Prosthesis/adverse effects , Postoperative Complications , Prosthesis Design/adverse effects , Synovitis/epidemiology , Arthroplasty, Replacement, Hip/adverse effects , Asymptomatic Diseases/epidemiology , Ceramics , Chromium/blood , Cobalt/blood , Disability Evaluation , Foreign-Body Reaction/diagnostic imaging , Foreign-Body Reaction/etiology , Hip Joint/diagnostic imaging , Hip Joint/pathology , Hip Joint/surgery , Humans , Ions/blood , Joint Capsule/diagnostic imaging , Joint Capsule/pathology , Joint Capsule/surgery , Linear Models , Longitudinal Studies , Magnetic Resonance Imaging , Metal-on-Metal Joint Prostheses/adverse effects , Patient Reported Outcome Measures , Polyethylene , Postoperative Period , Proportional Hazards Models , Prospective Studies , Prosthesis Failure , Risk Assessment , Risk Factors , Synovitis/diagnostic imaging , Synovitis/etiology , Treatment Outcome
12.
Magn Reson Imaging ; 79: 103-111, 2021 06.
Article in English | MEDLINE | ID: mdl-33753136

ABSTRACT

BACKGROUND: T2-weighted, two-point Dixon fast-spin-echo (FSE) is an effective technique for magnetic resonance neurography (MRN) that can provide quantitative assessment of muscle denervation. Low signal-to-noise ratio and inadequate fat suppression, however, can impede accurate interpretation. PURPOSE: To quantify effects of principal component analysis (PCA) denoising on tissue signal intensities and fat fraction (FF) and to determine qualitative image quality improvements from both denoising and water-weighting (WW) algorithms to improve nerve conspicuity and fat suppression. STUDY TYPE: Prospective. SUBJECTS: Twenty-one subjects undergoing MR neurography evaluation (11/10 male/female, mean age = 46.3±13.7 years) with 60 image volumes. Twelve subjects (23 image volumes) were determined to have muscle denervation based on diffusely elevated T2 signal intensity. FIELD STRENGTH/SEQUENCE: 3 T, 2D, two-point Dixon FSE. ASSESSMENT: Qualitative assessment included overall image quality, nerve conspicuity, fat suppression, pulsation and ringing artifacts by 3 radiologists separately on a three-point scale (1 = poor, 2 = average, 3 = excellent). Quantitative measurements for FF and signal intensity relative to normal muscle were made for nerve, abnormal muscle and subcutaneous fat. STATISTICAL TESTS: Linear and ordinal regression models were used for quantitative and qualitative comparisons, respectively; 95% confidence intervals (CIs) and p-values for pairwise comparisons were adjusted using the Holm-Bonferroni method. Inter-rater agreement was assessed using Gwet's agreement coefficient (AC2). RESULTS: Simulations showed PCA-denoising reduced FF error from 2.0% to 1.0%, and from 7.6% to 3.1% at noise levels of 10% and 30%, respectively. In human subjects, PCA-denoising did not change signal levels and FF quantitatively. WW decreased fat signal significantly (-83.6%, p < 0.001). Nerve conspicuity was improved by WW (odds ratio, OR = 5.8, p < 0.001). Fat suppression was improved by both PCA (OR = 3.6, p < 0.001) and WW (OR = 2.2, p < 0.001). Overall image quality was improved by PCA + WW (OR = 1.7, p = 0.04). CONCLUSIONS: WW and PCA-denoising improved nerve conspicuity and fat suppression in MR neurography. Denoising can potentially provide improved accuracy of FF maps for assessing fat-infiltrated muscle.


Subject(s)
Magnetic Resonance Imaging , Water , Female , Humans , Infant, Newborn , Magnetic Resonance Spectroscopy , Male , Prospective Studies , Signal-To-Noise Ratio
13.
Cartilage ; 12(3): 344-353, 2021 07.
Article in English | MEDLINE | ID: mdl-31161779

ABSTRACT

OBJECTIVE: To identify preoperative imaging-based indicators of knee degeneration that correlate with graft failure risk and postoperative clinical outcome scores after osteochondral graft treatment for chondral defects of the knee. DESIGN: Prospectively collected data from 113 patients (mean age, 34 years; 65% male) treated with mosaicplasty or osteochondral allograft transplantation (OCA) was reviewed. Four different aspects of knee degeneration were examined based on preoperative radiographs or magnetic resonance imaging: (1) Osteoarthritis using the Kellgren-Lawrence (KL) grading system, (2) meniscus volume, (3) meniscus quality, and (4) synovitis. Primary outcomes included graft failure, defined by removal/revision of the graft or conversion to arthroplasty, and patient responses to clinical outcome scores. RESULTS: Forty-one knees (36%) underwent mosaicplasty, and 72 knees (64%) underwent OCA. Mean duration of follow-up was 4.5 years (range, 2-14 years). A preoperative KL grade of ≥3 was correlated with increased failure rates (P = 0.01), lower postoperative International Knee Documentation Committee form (IKDC), Activities of Daily Living of the Knee Outcome Survey (KOS-ADL), and Overall Condition scores (P < 0.01), and decreased improvement in Overall Condition scores (P = 0.01). Within an individual tibiofemoral compartment, a preoperative meniscus volume grade of ≥3 (indicating <50% meniscus volume remaining) was correlated with increased condylar graft failure rates (P < 0.01). Preoperative meniscus quality and synovitis grades were not associated with graft failure rates or clinically meaningful differences in postoperative outcome scores. CONCLUSIONS: Greater preoperative osteoarthritis and meniscus volume loss were correlated with increased graft failure rates after osteochondral graft treatment for chondral defects of the knee.


Subject(s)
Cartilage Diseases , Intra-Articular Fractures , Meniscus , Osteoarthritis , Synovitis , Activities of Daily Living , Adult , Bone Transplantation , Female , Follow-Up Studies , Humans , Male , Treatment Outcome
14.
Orthop J Sports Med ; 8(10): 2325967120960088, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33195717

ABSTRACT

BACKGROUND: Fresh osteochondral allograft transplant (OCA) has good outcomes in the knee. However, donor tissue for patellar OCA is limited. Outcomes after nonorthotopic OCA of the patella using more readily available femoral condylar allograft (FCA) tissue have not been previously reported. PURPOSE: To assess short-term magnetic resonance imaging (MRI) and minimum 2-year clinical outcomes of nonorthotopic patellar OCA using an FCA donor. STUDY DESIGN: Case series; Level of evidence, 4. METHODS: A prospective institutional cartilage registry was reviewed to identify patients treated with patellar OCA using an FCA donor between August 2009 and June 2016. OCA plugs were obtained from the FCA at its trochlear-condylar junction and implanted into the recipient patellar lesion. Early postoperative MRI scans were graded by a blinded musculoskeletal radiologist using the Osteochondral Allograft MRI Scoring System (OCAMRISS). International Knee Documentation Committee Subjective Knee Evaluation Form (IKDC), Knee Outcomes Survey-Activities of Daily Living (KOS-ADL), and pain visual analog scale (VAS) scores were collected preoperatively and at minimum 2 years postoperatively, and outcomes were compared using the paired t test. RESULTS: A total of 25 patients were included for clinical outcome analysis and 20 patients for MRI analysis. MRI scans obtained at a mean of 11.4 months (range, 6-22 months) postoperatively showed a mean total OCAMRISS score of 9.0 (range, 7-11); mean bone, cartilage, and ancillary subscores were 2.6, 3.7, and 2.6, respectively. At the latest follow-up (mean, 46.5 months; range, 24-85 months), postoperative improvements were noted in IKDC (from 45.0 to 66.2; P = .0002), KOS-ADL (from 64.3 to 80.4; P = .0012), and VAS (from 5.1 to 3.4; P = .001) scores, with IKDC and KOS-ADL scores above the corresponding previously reported minimal clinically important difference. CONCLUSION: In this study, patellar OCA using nonorthotopic FCA led to significant short-term improvements in pain and patient-reported outcomes. The majority of nonorthotopic patellar grafts demonstrated full osseous incorporation and good restoration of the articular surface on MRI at short-term follow-up.

15.
Plast Reconstr Surg Glob Open ; 8(10): e3174, 2020 Oct.
Article in English | MEDLINE | ID: mdl-33173687

ABSTRACT

BACKGROUND: The anterolateral thigh (ALT) flap is a commonly utilized perforator-based flap in reconstructive surgery. Although previous studies have used various angiographic techniques to preoperatively image ALT perforators, none have investigated the efficacy of noncontrast magnetic resonance imaging (MRI). Our study investigates the efficacy of our institutional fat suppression noncontrast MRI sequence to characterize the number, location, and course of dominant skin perforators in the ALT for preoperative planning. METHODS: We queried our institutional database for 100 noncontrast thigh MRIs from July 2013 to July 2018 that included an axial fat suppression sequence with visualization from the lesser trochanter to the distal musculotendinous junction of the rectus femoris. Perforator course, size, and location relative to bony landmarks were determined. RESULTS: Of the 100 examinations, 70 included bilateral thighs for a total of 170 thighs for perforator analysis. An estimated 277 perforators were identified, of which 101 were septocutaneous (36.5%) and 176 were musculocutaneous (63.5%). An average of 1.63 perforators were visualized in each thigh (min, 1; max, 4). The average perforator diameter at exit from the anterior thigh compartment fascia was 2.5 mm (SD, 0.5). Perforator exit location along the anterior superior iliac spine- or lesser trochanter-patella line could be determined for n = 57 perforators and mapped into 3 predictable clusters. CONCLUSIONS: At least 1 perforator was found in each of 170 thighs imaged. Perforator course, size, and location measured with noncontrast MRI are consistent with prior literature. Noncontrast MRI is a low-morbidity imaging modality that may serve as an effective tool in preoperative planning of the ALT flap.

16.
Semin Musculoskelet Radiol ; 24(4): 355-366, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32992364

ABSTRACT

Osteoarthritis (OA) is one of the most common causes of disability throughout the world. Current therapeutic strategies are aimed at preventing the development and delaying the progression of OA, as well as repairing or replacing worn articular surfaces, because the regeneration of lost hyaline articular cartilage is not currently a clinically feasible option. Imaging is useful in formulating treatment strategies in patients at risk for OA, allowing assessment of risk factors, the degree of preexisting tissue damage, and posttreatment monitoring. Magnetic resonance imaging (MRI), in particular, provides in-depth evaluation of these patients, with optimal clinical sequencing allowing sensitive assessment of chondral signal and morphology, and the addition of advanced MRI techniques facilitating comprehensive evaluation of joint health, with increased sensitivity for changes in articular cartilage and surrounding joint tissues.


Subject(s)
Magnetic Resonance Imaging/methods , Osteoarthritis/diagnostic imaging , Contrast Media , Humans , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Osteoarthritis/therapy
17.
J Arthroplasty ; 35(6S): S63-S67, 2020 06.
Article in English | MEDLINE | ID: mdl-32005623

ABSTRACT

Biologic failures of hip arthroplasty have emerged as an increasing threat to the longevity of the prosthesis. While wear of modern-day bearings has been greatly reduced with the advent of cross-linked polyethylene, local reaction to metal particles either from the bearing itself or to any of the modular tapers appears to be on the rise. Monitoring of these reactions by the use of plain radiographs or serum markers appears to be insufficient to gauge the gravity of the response. Over the past decade, the use of magnetic resonance imaging (MRI) techniques has emerged as the superior noninvasive instrument to assess the extent of soft tissue reaction around hip implants. The use of MRI around implants was initially challenging due to the presence of relatively high ferrous metals especially cobalt which causes local distortion of the magnetic fields. Novel changes in pulse sequencing have greatly improved the sensitivity and specificity of MRI so that at this time, MR is the most predictive diagnostic tool in evaluating the extent of tissue destruction. We feel strongly that modern MRI techniques are the most important tool in the workup of the patient suspected of having an adverse tissue reaction after hip arthroplasty.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Arthroplasty, Replacement, Hip/adverse effects , Cobalt , Hip Prosthesis/adverse effects , Humans , Magnetic Resonance Imaging , Prosthesis Design , Prosthesis Failure
18.
J Orthop Res ; 38(7): 1455-1464, 2020 07.
Article in English | MEDLINE | ID: mdl-31975444

ABSTRACT

Magnetic resonance imaging (MRI) has historically been avoided for the routine clinical evaluation of metal implants at many clinical centers due to the presence of artifact that creates in-plane and through-plane distortions and signal intensity voids in generated images. However, when the image acquisition parameters are appropriately modified and advanced multi-spectral pulse sequences are used, high-quality diagnostic images can be generated and may be used for diagnosing patients with suspected periprosthetic pathology. MRI provides superior soft-tissue contrast and excellent sensitivity for mobile water and is, therefore, a valuable tool in the evaluation of these patients, given the increasing prevalence of arthroplasty within the general population. Knowledge of expected normal postoperative appearance in patients with total hip arthroplasty, total knee arthroplasty, and total shoulder arthroplasty facilitates the detection of abnormal findings in this population, as does familiarity with common pathologic conditions encountered in the periprosthetic region. This review article will provide background information regarding the presence of image artifacts, methods to reduce the artifacts, and application of MRI at 1.5 T for evaluating common complications in subjects with total knee arthroplasty, total hip arthroplasty, and total shoulder arthroplasty.


Subject(s)
Arthroplasty, Replacement/adverse effects , Magnetic Resonance Imaging , Periprosthetic Fractures/diagnostic imaging , Humans , Synovial Membrane/diagnostic imaging
19.
J Arthroplasty ; 35(3): 767-773, 2020 03.
Article in English | MEDLINE | ID: mdl-31679976

ABSTRACT

BACKGROUND: Femoral exposure for direct anterior approach (DAA) total hip arthroplasty (THA) invariably requires posterior soft tissue releases. Released posterior structures cannot be repaired. The purpose of this study is to describe the frequency and anatomic consequences of DAA THA posterior soft tissue releases and to compare the appearance of the anterior capsule between a group of patients who had capsulotomy and repair versus capsulectomy. METHODS: Thirty-two DAA THA patients underwent metal artifact reduction sequence magnetic resonance imaging at discharge and 1-year follow-up. Seventeen had underwent capsulotomy and repair and 15 capsulectomy. A radiologist blinded to intraoperative data scored each metal artifact reduction sequence magnetic resonance imaging. Anterior capsular integrity, status of the piriformis and conjoint tendons, and muscle atrophy were graded. Descriptive statistics were performed to analyze results. RESULTS: Immediately postoperatively, 75% of piriformis tendons were intact and 38% of conjoined tendons were intact. At 1 year, 97% had an intact piriformis and conjoined tendon, although many were in continuity through scar with the capsule. The posterior capsule directly contacted bone in all patients. At 1 year, none of the patients who underwent capsulotomy with repair had persistent anterior capsule defects, while 27% in the capsulectomy group had persistent defects. CONCLUSION: Posterior capsule and conjoined tendon releases were commonly performed during DAA THA, yet continuity with bone was frequently achieved at 1 year. In this study, capsulotomy with repair resulted in no anterior capsular defects when compared with capsulectomy. These results may support improved THA stability observed after DAA with capsular repair despite posterior soft tissue releases. LEVEL OF EVIDENCE: Level III, prospective cohort study.


Subject(s)
Antiviral Agents , Arthroplasty, Replacement, Hip , Hepatitis C, Chronic , Capsules , Hip Joint/surgery , Humans , Prospective Studies
20.
J Clin Orthop Trauma ; 10(Suppl 1): S13-S19, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31700203

ABSTRACT

PURPOSE: To determine the clinical significance of fluid imbibition at the bone-cartilage interface seen on postoperative MRI scans after osteochondral grafting of chondral lesions of the knee. METHODS: Retrospective review of patients enrolled in a prospective cartilage repair registry. Included patients underwent osteochondral autografting or allografting of the knee, had minimum one year of clinical follow-up, and underwent at least two postoperative MRI scans. The primary outcome was reoperation for arthroscopic debridement and chondroplasty or graft revision. Secondary outcomes included the radiographic fate of fluid imbibition. RESULTS: A total of 48 knees in 46 patients were analyzed, with mean 39 months clinical follow-up. Nine patients (19%) had fluid imbibition on at least one postoperative MRI scan, all of whom received allograft. Of these, two (22%) required eventual graft revision, four (45%) underwent arthroscopic chondroplasty but did not require revision, and three (33%) did not require any additional surgery by final follow-up. No demographic or surgical variable was associated with the presence of fluid imbibition. Fluid imbibition was significantly associated with need for chondroplasty (p = 0.05), but not graft revision. CONCLUSIONS: Fluid imbibition on postoperative MRI following osteochondral allografting of the knee is associated with the need for arthroscopic chondroplasty, but should not be interpreted as a sign of a failing graft. LEVEL OF EVIDENCE: Level IV, Case Series.

SELECTION OF CITATIONS
SEARCH DETAIL
...