Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
1.
Occup Med (Lond) ; 65(3): 251-5, 2015 Apr.
Article in English | MEDLINE | ID: mdl-25825508

ABSTRACT

BACKGROUND: Occupational asthma commonly results in work-related changes in serial peak expiratory flow (PEF) measurements. Whether alveolitis can result in similar changes is unknown. AIMS: To identify differences and similarities of serial PEF between workers with occupational alveolitis and asthma seen during an outbreak investigation in a factory with metal-working fluid exposure. METHODS: Workers with respiratory symptoms and rest-day improvement were identified by questionnaire. Each was asked to measure PEF 8 times daily for 4 weeks at home and work. Alveolitis was subsequently diagnosed from a validated scoring system including radiological changes, carbon monoxide diffusing capacity, bronchoalveolar lavage and biopsy results. Occupational asthma was confirmed with a positive Oasys score >2.5 and a mean rest-work PEF >16 l/min from serial 2-hourly PEF measurements. The Oasys PEF plotter calculated differences between rest and workdays for mean PEF, diurnal variation and the scores were used to confirm an occupational effect (Oasys, area between curve and time point). Records were compared between the alveolitis group and the group with occupational asthma without alveolitis. RESULTS: Forty workers with occupational asthma and 16 with alveolitis had indistinguishable PEF changes on workdays in terms of magnitude (median reduction 18.5 and 16.1 l/min, respectively) and diurnal variation. Immediate reactions were more common with occupational asthma and late reactions more common with alveolitis. CONCLUSIONS: PEF responses to metal-working fluid aerosols do not distinguish occupational asthma from alveolitis except in timing. They can be used to identify the workplace as the cause of asthma and also alveolitis.


Subject(s)
Alveolitis, Extrinsic Allergic/diagnosis , Asthma/diagnosis , Occupational Diseases/diagnosis , Peak Expiratory Flow Rate/physiology , Adult , Alveolitis, Extrinsic Allergic/complications , Asthma/etiology , Data Interpretation, Statistical , Female , Humans , Male , Middle Aged , Occupational Diseases/epidemiology , Occupational Diseases/etiology , Occupational Exposure/adverse effects , Occupational Exposure/statistics & numerical data , Sensitivity and Specificity
2.
Occup Med (Lond) ; 62(7): 533-40, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22826555

ABSTRACT

BACKGROUND: Five metal turners employed by an aerospace manufacturer presented to the Birmingham Chest Clinic occupational lung disease unit. Four cases of occupational asthma (OA) due to chromium salt (3) and cobalt (1) were diagnosed by serial peak-expiratory flow measurements and specific inhalation challenge testing. AIMS: To measure the extent of the outbreak and to provide epidemiological data to ascertain the aetiology. METHODS: Participants answered a detailed, self-administered questionnaire, designed to detect occupational lung disease. Urine chromium and cobalt excretion, spirometry and exhaled nitric oxide measurements were taken. Those with possible, probable or definite non-OA or OA, after questionnaire, were invited to undertake two-hourly peak flow measurements and received specialist follow-up. RESULTS: A total of 62 workers (95% of workforce) participated. Sixty-one per cent of employees were working in higher metalworking fluid (MWF) exposure areas. Ninety per cent of workers had urinary chromium excretion indicating occupational exposure. Sixty-six per cent of workers reported active respiratory symptoms, although there were no significant differences between exposure groups. Two further workers with probable OA were identified and had significantly higher urinary chromium and cobalt concentration than asymptomatic controls. Eighteen cases of occupational rhinitis (OR) were identified, with significantly raised urinary chromium concentration compared with asymptomatic controls. CONCLUSIONS: Chromium salt and cobalt can be responsible for OA and OR in workers exposed to MWF aerosols. Onset of symptoms in those with positive specific challenges followed change in MWF brand. Workers with OA had increased urinary concentrations of chromium and cobalt, and those with OR had increased urinary concentrations of chromium.


Subject(s)
Air Pollutants, Occupational/adverse effects , Asthma, Occupational/epidemiology , Chromium/adverse effects , Cobalt/adverse effects , Disease Outbreaks , Adult , Asthma, Occupational/physiopathology , Asthma, Occupational/urine , Chromium/urine , Cobalt/urine , Cross-Sectional Studies , Humans , Inhalation Exposure , Lung/physiopathology , Male , Metals/adverse effects , Middle Aged , United Kingdom/epidemiology , Welding
3.
Occup Med (Lond) ; 62(7): 525-32, 2012 Oct.
Article in English | MEDLINE | ID: mdl-22778240

ABSTRACT

BACKGROUND: Diurnal variation (DV) affects lung function but the changes are thought to be related to sleep patterns rather than time of day. When diagnosing occupational asthma (OA), serial peak expiratory flow (PEF) measurements are the recommended first line investigation, but could be confounded by shift work. AIMS: The aim of the study was to investigate the effects of shift work on PEF measurements used for diagnosing OA. METHODS: PEF records containing more than one shift pattern with ≥ 4 days per shift were identified. OA diagnosis was based on an Oasys-2 score ≥ 2.51 and non-OA on having an alternative clinical diagnosis and Oasys-2 score <2.51. The mean area between curves (ABC) score, mean PEF DV and cross-shift PEF changes were calculated for each shift. RESULTS: Records from 123 workers with OA and 69 without OA satisfied inclusion criteria. In the OA group, PEF declined more on afternoon and night shifts than days (P < 0.001). The ABC score was lower in the OA group on night (P < 0.05) and afternoon shifts (P < 0.05) as compared with days, without significant differences in DV. Among those without OA, cross-shift PEF increased more on day shifts (mean + 25 l/min) than afternoon or night shifts (+1 l/min) (P < 0.001). The sensitivity for the ABC score and DV were good and similar across shifts, but specificity was reduced using DV (DV mean 39%; ABC 98%). CONCLUSIONS: PEF responses between work and rest show small differences according to shift type. The ABC score has a high sensitivity and specificity for all shifts; differences in DV have lower specificity.


Subject(s)
Asthma, Occupational/physiopathology , Occupational Diseases/physiopathology , Work/statistics & numerical data , Adult , Asthma, Occupational/prevention & control , Circadian Rhythm , Female , Humans , Male , Middle Aged , Occupational Diseases/prevention & control , Peak Expiratory Flow Rate , Sensitivity and Specificity , Work Schedule Tolerance
4.
Thorax ; 64(12): 1032-6, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19850961

ABSTRACT

BACKGROUND: The diagnosis of occupational asthma requires objective confirmation. Analysis of serial measurements of peak expiratory flow (PEF) is usually the most convenient first step in the diagnostic process. A new method of analysis originally developed to detect late asthmatic reactions following specific inhalation testing is described. This was applied to serial PEF measurements made over many days in the workplace to supplement existing methods of PEF analysis. METHODS: 236 records from workers with independently diagnosed occupational asthma and 320 records from controls with asthma were available. The pooled standard deviation for rest day measurements was obtained from an analysis of variance by time. Work day PEF measurements were meaned into matching 2-hourly time segments. Time points with mean work day PEF statistically lower (at the Bonferroni adjusted 5% level) than the rest days were counted after adjusting for the number of contributing measurements. RESULTS: A minimum of four time point comparisons were needed. Records with >or=2 time points significantly lower on work days had a sensitivity of 67% and a specificity of 99% for the diagnosis of occupational asthma against independent diagnoses. Reducing the requirements to >or=1 non-waking time point difference increased sensitivity to 77% and reduced specificity to 93%. The analysis was only applicable to 43% of available records, mainly due to differences in waking times on work and rest days. CONCLUSION: Time point analysis complements other validated methods of PEF analysis for the diagnosis of occupational asthma. It requires shorter records than are required for the Oasys score and can identify smaller changes than other methods, but is dependent on low rest day PEF variance.


Subject(s)
Asthma/diagnosis , Occupational Diseases/diagnosis , Peak Expiratory Flow Rate , Adult , Asthma/etiology , Asthma/physiopathology , Bronchial Provocation Tests/methods , Circadian Rhythm/physiology , Female , Humans , Male , Middle Aged , Occupational Diseases/etiology , Occupational Diseases/physiopathology , Sensitivity and Specificity
5.
Eur Respir J ; 34(3): 574-8, 2009 Sep.
Article in English | MEDLINE | ID: mdl-19324953

ABSTRACT

Cross-shift measurements of peak expiratory flow (PEF) are commonly employed in the diagnosis of occupational asthma, although evidence for this approach is lacking. The current paper presents an evaluation of the technique. Mean changes in PEF across morning/day shifts were compared between workers with occupational asthma, confirmed using specific challenge testing, and non-working asthmatics. Individuals were divided into a development set, used to identify the optimum cross-shift change for diagnosing occupational asthma, and an evaluation set, used to test the sensitivity and specificity of this value. Comparative analysis of serial PEF records was performed using the Oasys-2 computerised system. A cross-shift decrease in PEF of 5 L.min(-1) achieved acceptable specificity in the development set. Applied to the evaluation set, this cut-off had a specificity of 90.9% and a sensitivity of 50%. Sensitivity could not be improved without unacceptable compromise to specificity. Analysis of serial PEF records using linear discriminant analysis identified occupational asthma with a sensitivity of 83.3% and a specificity of 90.9%. Serial analysis using mean work/rest day PEF comparison had a sensitivity of 66.7% and a specificity of 100%. Cross-shift changes in PEF in morning/day-shift workers have poor sensitivity in diagnosing occupational asthma, and are inferior to serial techniques.


Subject(s)
Asthma/diagnosis , Asthma/physiopathology , Circadian Rhythm/physiology , Occupational Diseases/diagnosis , Occupational Diseases/physiopathology , Peak Expiratory Flow Rate/physiology , Adult , Diagnosis, Computer-Assisted , Female , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity
6.
Thorax ; 62(11): 981-90, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17504818

ABSTRACT

BACKGROUND: Exposure to metal working fluid (MWF) has been associated with outbreaks of extrinsic allergic alveolitis (EAA) in the USA, with bacterial contamination of MWF being a possible cause, but is uncommon in the UK. Twelve workers developed EAA in a car engine manufacturing plant in the UK, presenting clinically between December 2003 and May 2004. This paper reports the subsequent epidemiological investigation of the whole workforce. The study had three aims: (1) to measure the extent of the outbreak by identifying other workers who may have developed EAA or other work-related respiratory diseases; (2) to provide case detection so that those affected could be treated; and (3) to provide epidemiological data to identify the cause of the outbreak. METHODS: The outbreak was investigated in a three-phase cross-sectional survey of the workforce. In phase I a respiratory screening questionnaire was completed by 808/836 workers (96.7%) in May 2004. In phase II 481 employees with at least one respiratory symptom on screening and 50 asymptomatic controls were invited for investigation at the factory in June 2004. This included a questionnaire, spirometry and clinical opinion. 454/481 (94.4%) responded and 48/50 (96%) controls. Workers were identified who needed further investigation and serial measurements of peak expiratory flow (PEF). In phase III 162 employees were seen at the Birmingham Occupational Lung Disease clinic. 198 employees returned PEF records, including 141 of the 162 who attended for clinical investigation. Case definitions for diagnoses were agreed. RESULTS: 87 workers (10.4% of the workforce) met case definitions for occupational lung disease, comprising EAA (n = 19), occupational asthma (n = 74) and humidifier fever (n = 7). 12 workers had more than one diagnosis. The peak onset of work-related breathlessness was Spring 2003. The proportion of workers affected was higher for those using MWF from a large sump (27.3%) than for those working all over the manufacturing area (7.9%) (OR = 4.39, p<0.001). Two workers had positive specific provocation tests to the used but not the unused MWF solution. CONCLUSIONS: Extensive investigation of the outbreak of EAA detected a large number of affected workers, not only with EAA but also occupational asthma. This is the largest reported outbreak in Europe. Mist from used MWF is the likely cause. In workplaces using MWF there is a need to carry out risk assessments, to monitor and maintain fluid quality, to control mist and to carry out respiratory health surveillance.


Subject(s)
Alveolitis, Extrinsic Allergic/epidemiology , Asthma/epidemiology , Automobiles/statistics & numerical data , Industrial Oils/toxicity , Metals/toxicity , Occupational Diseases/epidemiology , Aged , Alveolitis, Extrinsic Allergic/chemically induced , Asthma/chemically induced , Cross-Sectional Studies , Disease Outbreaks , England/epidemiology , Female , Humans , Male , Middle Aged , Occupational Diseases/chemically induced , Occupational Exposure/adverse effects , Respiration Disorders/chemically induced , Respiration Disorders/epidemiology , Respiratory Function Tests
SELECTION OF CITATIONS
SEARCH DETAIL
...