Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 22
Filter
1.
Int J Cardiovasc Imaging ; 37(8): 2501-2515, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34019206

ABSTRACT

To provide clinically relevant criteria for differentiation between the athlete's heart and similar appearing hypertrophic (HCM), dilated (DCM), and arrhythmogenic right-ventricular cardiomyopathy (ARVC) in MRI. 40 top-level athletes were prospectively examined with cardiac MR (CMR) in two university centres and compared to retrospectively recruited patients diagnosed with HCM (n = 14), ARVC (n = 18), and DCM (n = 48). Analysed MR imaging parameters in the whole study cohort included morphology, functional parameters and late gadolinium enhancement (LGE). Mean left-ventricular enddiastolic volume index (LVEDVI) was high in athletes (105 ml/m2) but significantly lower compared to DCM (132 ml/m2; p = 0.001). Mean LV ejection fraction (EF) was 61% in athletes, below normal in 7 (18%) athletes vs. EF 29% in DCM, below normal in 46 (96%) patients (p < 0.0001). Mean RV-EF was 54% in athletes vs. 60% in HCM, 46% in ARVC, and 41% in DCM (p < 0.0001). Mean interventricular myocardial thickness was 10 mm in athletes vs. 12 mm in HCM (p = 0.0005), 9 mm in ARVC, and 9 mm in DCM. LGE was present in 1 (5%) athlete, 8 (57%) HCM, 10 (56%) ARVC, and 21 (44%) DCM patients (p < 0.0001). Healthy athletes' hearts are characterized by both hypertrophy and dilation, low EF of both ventricles at rest, and increased interventricular septal thickness with a low prevalence of LGE. Differentiation of athlete's heart from other non-ischemic cardiomyopathies in MRI can be challenging due to a significant overlap of characteristics also seen in HCM, ARVC, and DCM.


Subject(s)
Cardiomegaly, Exercise-Induced , Cardiomyopathies , Cardiomyopathy, Hypertrophic , Athletes , Cardiomyopathy, Hypertrophic/diagnostic imaging , Contrast Media , Gadolinium , Humans , Hypertrophy, Left Ventricular , Magnetic Resonance Imaging , Predictive Value of Tests , Retrospective Studies
2.
Herz ; 43(1): 53-60, 2018 Feb.
Article in German | MEDLINE | ID: mdl-28116464

ABSTRACT

Physical activity is nowadays an established therapeutic principle concerning primary and secondary prevention of cardiovascular diseases; therefore, in internal sports medicine various aspects go beyond basic cardiological knowledge and require special medical expertise (sports cardiology). Acute cardiac risk is increased during physical activity; therefore, physical activity should be individually phased under consideration of the whole clinical situation. Physical training results in a functional adaptation of the cardiovascular system. Moreover, a structural adaptation can also be observed in competitive athletes but a differentiation between athlete's heart and cardiomyopathy is sometimes challenging. Preparticipation screening verifiably reduces the incidence of sudden cardiac death in athletes. Respective recommendations for the required diagnostics have been published and statutory health insurances are increasingly more willing to bear the incurred costs. Statistically, doping is more frequent in performance-orientated leisure time sports than in competitive sports. Drugs which are relevant for doping have partially irreversible cardiac side effects.


Subject(s)
Cardiovascular Diseases/physiopathology , Heart/physiopathology , Sports/physiology , Cardiomegaly, Exercise-Induced , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Doping in Sports/prevention & control , Humans , Incidence , Mass Screening , Physical Conditioning, Human , Physical Endurance/physiology , Physical Fitness/physiology , Risk Factors
3.
Scand J Med Sci Sports ; 28(4): 1397-1403, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29239051

ABSTRACT

The aim of the study was to evaluate the diagnostic accuracy of carotid ultrasound (CU) to predict coronary atherosclerosis in asymptomatic male marathon runners. A total of 49 male marathon runners older than 45 years (mean age 53.3 ± 7.2 years, range 45-74 years) received CU and cardiac CT angiography (CTA) including calcium scoring (CS). Results of CU and CTA were classified binary: 1. Absence of atherosclerosis and 2. Presence of atherosclerosis. The extent of atherosclerosis was not primary end point of the study. Mean PROCAM score was 2.3% (SD 2.2, range 0.44%-12.34%). One person had to be excluded from analysis (one missing CT-scan). From the remaining 48 marathon runners, 17 (35.4%) had carotid atherosclerosis and 22 (45.8%) coronary atherosclerosis. Atherosclerosis in either exam was diagnosed in 27/48 (56.3%) marathon runners. Diagnostic accuracy of CU to predict coronary atherosclerosis was: sensitivity 54.55% (95% CI 32.2-75.6), specificity 80.8% (CI 60.6-93.4), positive predictive value 70.6 (CI 44.1-89.9), negative predictive value 67.7 (CI 48.6-83.3) with a positive likelihood ratio of 2.84 (CI 1.18-6.82) and a negative likelihood ratio of 0.56 (CI 0.34-0.92). Coronary and/or carotid atherosclerosis can be detected in more than 50% of male marathon runners aged older than 45 years. The diagnostic value of carotid ultrasound to predict coronary atherosclerosis is low but higher than the accuracy of rest- or stress-ECG. As outcome studies in sportsmen are still missing, the routine evaluation of the carotid arteries by ultrasound or even cardiac CT cannot be recommended at present. Furthermore, the incidence of atherosclerosis by our method in normal population is not known.


Subject(s)
Carotid Artery Diseases/diagnosis , Coronary Artery Disease/diagnosis , Running , Asymptomatic Diseases , Athletes , Carotid Arteries/diagnostic imaging , Coronary Angiography , Humans , Male , Middle Aged , Tomography, X-Ray Computed , Ultrasonography
4.
Rofo ; 187(7): 561-8, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25831468

ABSTRACT

PURPOSE: To evaluate the prevalence of coronary artery disease (CAD) in middle-aged, male marathon runners using coronary dual source CT angiography (DSCTA). MATERIALS AND METHODS: 50 male marathon runners older than 45 years (mean age: 52.7, standard deviation: 5.9 years, range: 45 to 67 years) received DSCTA including calcium scoring (CS) in addition to standard pre-participation screening. Based on standard risk factors, the risk for coronary events was calculated using the PROCAM score. Coronary status was defined using the following system: 1. absence of CAD (CS zero, no coronary plaques) 2. mild coronary atherosclerosis (CS > 0, coronary plaques with luminal narrowing < 50 %), 3. moderate coronary atherosclerosis (CS > 0, luminal narrowing > 50 %), 4. significant CAD (CS > 0, luminal narrowing > 75 %). RESULTS: The mean PROCAM score was 1.85 % (standard deviation = 1.56, range 0.39 to 8.47 %). 26/50 marathon runners had no atherosclerosis. 1 of the remaining 24 participants had significant CAD, 3 had moderate coronary atherosclerosis and 20 had mild coronary atherosclerosis. Treadmill exercise testing was unremarkable in terms of myocardial ischemia in all participants. Age, systolic blood pressure, personal minimum time, family history of cardiovascular disease and PROCAM score were factors associated with an increased risk for coronary atherosclerosis. CONCLUSION: Coronary atherosclerosis can be detected in almost 50 % of male marathon runners aged older than 45 years. In 24 % of the participants plaques were located in the proximal coronary system. However, only a minority of these persons have obstructive CAD. As expected, treadmill exercise testing failed to detect these persons that possibly have a higher risk for coronary events. KEY POINTS: • Coronary atherosclerosis can be detected in ~50 % of male marathon runners > 45 years. • Only a minority of these persons have obstructive CAD. • Treadmill exercise testing failed to detect these persons. • Cardiac CT might help to identify athletes with elevated risk for coronary events, especially in persons with a family history of coronary artery.


Subject(s)
Coronary Angiography/statistics & numerical data , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/epidemiology , Running/statistics & numerical data , Tomography, X-Ray Computed/statistics & numerical data , Aged , Germany/epidemiology , Humans , Male , Men's Health/statistics & numerical data , Middle Aged , Prevalence , Reproducibility of Results , Risk Factors , Sensitivity and Specificity
5.
Rofo ; 185(12): 1167-74, 2013 Dec.
Article in English | MEDLINE | ID: mdl-23897528

ABSTRACT

PURPOSE: Sudden cardiac death [SCD] in competitive athletes is caused by a diverse set of cardiovascular diseases such as hypertrophic and dilated cardiomyopathy [HCM/DCM], myocarditis, coronary anomalies or even coronary artery disease. In order to identify potential risk factors responsible for SCD, elite athletes underwent cardiac magnetic resonance [CMR] imaging. MATERIALS AND METHODS: 73 male [M] and 22 female [F] athletes (mean age 35.2 ±â€Š11.4 years) underwent CMR imaging. ECG-gated breath-hold cine SSFP sequences were used for the evaluation of wall motion abnormalities and myocardial hypertrophy as well as for quantitative analysis (left and right ventricular [LV, RV] end-diastolic and end-systolic volume [EDV, ESV], stroke volume [SV], ejection fraction [EF] and myocardial mass [MM]). Furthermore, left and right atrial sizes were assessed by planimetry and delayed enhancement imaging was performed 10 minutes after the application of contrast agent. Coronary arteries were depicted using free-breathing Flash-3 D MR angiography. RESULTS: The quantitative analyses showed eccentric hypertrophy of the left ventricle (remodeling index [MM/LV-EDV]: M 0.75, F 0.665), enlargement of the RV volumes (RV-EDV: M 122.6 ±â€Š19.0 ml/m², F 99.9 ±â€Š7.2 ml/m²) and an increased SV (LV-SV: M 64.7 ±â€Š10.0 ml/m², F 56.5 ±â€Š5.7 ml/m²; RV-SV; M 66.7 ±â€Š10.4 ml/m², F 54.2 ±â€Š7.1 ml/m²). Abnormal findings were detected in 6 athletes (6.3 %) including one benign variant of coronary anomaly and abnormal late gadolinium enhancement in 2 cases. None of the athletes showed wall motion abnormalities or signs of myocardial ischemia. CONCLUSION: CMR imaging of endurance athletes revealed abnormal findings in more than 5 % of the athletes. However, the prognostic significance remains unclear. Thus, cardiac MRI cannot be recommended as a routine examination in the care of athletes.


Subject(s)
Athletes , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Heart Diseases/diagnosis , Magnetic Resonance Imaging/methods , Adolescent , Adult , Aged , Cardiac Output/physiology , Cardiac Volume/physiology , Cardiac-Gated Imaging Techniques/methods , Contrast Media/administration & dosage , Coronary Vessel Anomalies/diagnosis , Coronary Vessel Anomalies/physiopathology , Echocardiography , Female , Heart Atria/pathology , Heart Atria/physiopathology , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/physiopathology , Heart Diseases/physiopathology , Heart Ventricles/pathology , Heart Ventricles/physiopathology , Humans , Image Enhancement/methods , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/methods , Magnetic Resonance Angiography/methods , Male , Mass Screening , Middle Aged , Prospective Studies , Sensitivity and Specificity , Stroke Volume/physiology , Young Adult
6.
Article in German | MEDLINE | ID: mdl-22286246

ABSTRACT

Cardiovascular disease is the leading cause of mortality in western industrialized countries. Physical inactivity is known to be an important risk factor. The present publication gives an overview of studies with the topic physical activity and relative risk of cardiovascular disease. Furthermore, aspects influencing the association between physical activity and cardiovascular disease, e.g., the duration and intensity of exercise, adults older than 60 years, late onset of physical activity, and body mass index, are discussed.


Subject(s)
Cardiovascular Diseases/epidemiology , Cardiovascular Diseases/prevention & control , Evidence-Based Medicine , Exercise Therapy/statistics & numerical data , Motor Activity , Risk Reduction Behavior , Adult , Cardiovascular Diseases/diagnosis , Humans , Prevalence , Risk Assessment , Risk Factors
7.
Minerva Cardioangiol ; 57(4): 495-509, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19763071

ABSTRACT

Multislice computed tomography is an emerging diagnostic modality in cardiology practice. Within the last decade a rapid technical evolution from 4-slice scanners to 64-slice and meanwhile 320-slice scanners which faster gantry rotation time has taken place. These advances as well as improved post-processing tools account for a stabilization of image quality and allow assessing cardiac structures with high spatial and temporal resolution. Moreover, dedicated acquisition techniques have been employed to reduce radiation exposure to a minimum. Today cardiac computed tomography is not only able to depict the coronary arteries, but to get reliable information about cardiac function and cardiac structure. This review focuses on present clinical indications and future application of multi-slice computed tomography in clinical cardiology.


Subject(s)
Coronary Angiography/methods , Heart Diseases/diagnostic imaging , Heart/diagnostic imaging , Tomography, Spiral Computed/methods , Tomography, X-Ray Computed/methods , Contrast Media , Coronary Artery Bypass , Coronary Stenosis/diagnostic imaging , Diagnosis, Differential , Electrocardiography , Forecasting , Heart Rate , Heart Valve Diseases/diagnostic imaging , Humans , Tomography, Spiral Computed/standards , Ventricular Function, Left
8.
Br J Radiol ; 82(982): 805-12, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19332517

ABSTRACT

Non-invasive assessment of plaque volume and composition is important for risk stratification and long-term studies of plaque stabilisation. Our aim was to evaluate dual-source computed tomography (DSCT) and colour-coded analysis in the quantification and classification of coronary atheroma. DSCT and virtual histology intravascular ultrasound (IVUS-VH) were prospectively performed in 14 patients. 22 lesions were compared in terms of plaque volume, maximal per cent vessel stenosis and percentages of fatty, fibrous or calcified components. Plaque characterisation was performed with software that automatically segments luminal or outer vessel boundaries and uses CT attenuation for a colour-coded plaque analysis. Good correlation was found for per cent vessel stenosis in DSCT (53+/-13%) and IVUS (51+/-14%; r(2) = 0.70). Mean volumes for entire plaque and non-calcified atheroma were 68.5+/-33 mm(3) and 56.7+/-30 mm(3), respectively, in DSCT and 60.8+/-29 mm(3) and 55.8+/-26 mm(3), respectively, in IVUS. Mean percentages of fatty, fibrous or calcified components were 28.2+/-6%, 53.2+/-9% and 18.7+/-13%, respectively, in DSCT and 29.9+/-5%, 55.3+/-12% and 14.4+/-9%, respectively, in IVUS-VH. Significant overestimation was present for the entire plaque and the volume of calcified plaque (p = 0.03; p = 0.0004). Although good correlation with IVUS was obtained for the entire plaque (r(2) = 0.76) and non-calcified plaque volume (r(2) = 0.84), correlation proved very poor and insignificant for percentage plaque composition. Interclass correlation coefficients for non-calcified plaque volume and percentages of fatty, fibrous or calcified components were 0.99, 0.99, 0.95 and 0.98, respectively, and intraclass coefficients were 0.98, 0.93, 0.98 and 0.99, respectively. We found that using Hounsfield unit-based analysis, DSCT allows for accurate quantification of non-calcified plaque. Although percentage plaque composition proves highly reproducible, it is not correlated with IVUS-VH.


Subject(s)
Atherosclerosis/diagnostic imaging , Calcinosis/diagnostic imaging , Coronary Stenosis/diagnostic imaging , Tomography, X-Ray Computed/methods , Aged , Color , Coronary Angiography/methods , Female , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Prospective Studies , Radiographic Image Interpretation, Computer-Assisted , Ultrasonography, Interventional/methods
9.
Eur Radiol ; 18(11): 2466-74, 2008 Nov.
Article in English | MEDLINE | ID: mdl-18491107

ABSTRACT

To assess HU-based color mapping for characterization of coronary plaque, using intravascular ultrasound virtual histology (IVUS-VH) as a standard of reference. Dual-source computed tomography and IVUS-VH were prospectively performed in 13 patients. In five lesions, HU thresholds of the color-coding software were calibrated to IVUS-VH. In a 15-lesion verification cohort, volumes of vessel, lumen and plaque or percentages of lipid, fibrous and calcified components were obtained through use of pre-set HU cut-offs as well as through purely visual adjustment of color maps. Calibrated HU ranges for fatty or fibrous plaque, lumen and calcification were -10-69, 70-158, 159-436 and 437+. Using these cut-offs, HU-based analysis achieved good agreement of plaque volume with IVUS (47.0 vs. 51.0 mm(3)). Visual segmentation led to significant overestimation of atheroma (61.6 vs. 51.0 mm(3); P = 0.04) Correlation coefficients for volumes of vessel, lumen and plaque were 0.92, 0.87 and 0.83 with HU-based analysis or 0.92, 0.85 and 0.71 with visual evaluation. With both methods, correlation of percentage plaque composition was poor or insignificant. HU-based plaque analysis showed good reproducibility with intra-class correlation coefficients being 0.90 for plaque volume and 0.81, 0.94 or 0.98 for percentages of fatty, fibrous or calcified components. With use of optimized HU thresholds, color mapping allows for accurate and reproducible quantification of coronary plaque.


Subject(s)
Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Echocardiography, Doppler, Color/methods , Tomography, X-Ray Computed/methods , Aged , Female , Humans , Male , Pilot Projects , Reproducibility of Results , Sensitivity and Specificity
10.
Eur J Radiol ; 66(1): 134-41, 2008 Apr.
Article in English | MEDLINE | ID: mdl-17600648

ABSTRACT

OBJECTIVE: The aim of this study was to assess the impact of heart rate, heart rate variability and calcification on image quality and diagnostic accuracy in an unselected patient collective. SUBJECTS AND METHODS: One hundred and two consecutive patients with known or suspected coronary artery disease underwent both 64-MSCT and invasive coronary angiography. Image quality (IQ) was assessed by independent observers using a 4-point scale from excellent (1) to non-diagnostic (4). Accuracy of MSCT regarding detection or exclusion of significant stenosis (>50%) was evaluated on a per segment basis in a modified AHA 13-segment model. Effects of heart rate, heart rate variability, calcification and body mass index (BMI) on IQ and accuracy were evaluated by multivariate regression. IQ and accuracy were further analysed in subgroups of significant predictor variables and simple regression performed to calculate thresholds for adequate IQ. RESULTS: Mean heart rate was 68.2+/-13.3 bpm, mean heart rate variability 11.5+/-16.0 beats per CT-examination (bpct) and median Agatston score 226.5. Average IQ score was 2+/-0.6 whilst diagnostic quality was obtained in 89% of segments. Overall sensitivity, specificity, PPV or NPV was 91.2%, 99.2%, 95.3% or 98.3%. According to multivariate regression, overall IQ was significantly related to heart rate and calcification (P=0.0038; P<0.0001). The effect of heart rate variability was limited to IQ of RCA segments (P=0.018); BMI was not related to IQ (P=0.52). Calcification was the only predictor variable with significant effect on the number of non-diagnostic segments (P<0.0001). In a multivariate regression, calcification was also the single factor with impact on diagnostic accuracy (P=0.0049). CONCLUSION: Whilst heart rate, heart rate variability and calcification all show an inverse correlation to IQ, severe calcium burden remains the single factor with translation of such effect into decrease of diagnostic accuracy.


Subject(s)
Calcinosis/diagnostic imaging , Coronary Angiography/methods , Coronary Stenosis/diagnostic imaging , Tomography, Spiral Computed , Body Mass Index , Chi-Square Distribution , Contrast Media , Female , Heart Rate/physiology , Humans , Iopamidol/analogs & derivatives , Male , Middle Aged , Regression Analysis , Statistics, Nonparametric
11.
Eur Radiol ; 17(11): 2948-56, 2007 Nov.
Article in English | MEDLINE | ID: mdl-17929027

ABSTRACT

The purpose was to assess 64-slice CT in the analysis of global and regional ventricular function, using a model of acute and subacute myocardial infarction in comparison with cine-MRI. Seven pigs underwent standard MSCT and MRI examination a median 1 and 21 days following creation of reperfused myocardial infarction. Endocardial and epicardial contours were manually defined and ventricular volumes calculated according to Simpson's method. Results were compared by Pearson's correlation coefficient and Blant-Altman analysis. Wall motion was assessed on cine-images and evaluated by kappa statistics. MSCT revealed a strong correlation with cine-MRI regarding quantification of end-diastolic volume (EDV; r = 0.97), end-systolic volume (ESV; r = 0.97), stroke volume (SV; r = 0.94), ejection fraction (EF; r = 0.95) or myocardial mass (MM; r =0.94 ). Minor overestimation was observed for EDV and ESV (bias -1.7 ml; -1.5 ml; P=0.095; 0.025), whilst the mean difference for EF was found to be negligible (bias 0.9%; P = 0.18). Both modalities showed a 96.2% segmental agreement in regional wall motion (weighted-kappa 0.91 for 238 segments). This was true for both acute and subacute infarct phase and MSCT, and thereby enabled accurate intraindividual follow-up of segmental dysfunction. Sixty-four-slice CT allows for reliable analysis of global cardiac function and, moreover, provides accurate evaluation of wall motion in acute and subacute myocardial infarct.


Subject(s)
Magnetic Resonance Imaging/methods , Myocardial Infarction/diagnosis , Myocardial Infarction/pathology , Tomography, X-Ray Computed/instrumentation , Tomography, X-Ray Computed/methods , Ventricular Function, Left , Acute Disease , Animals , Diastole , Heart/diagnostic imaging , Models, Statistical , Myocardial Infarction/diagnostic imaging , Myocardium/pathology , Swine , Systole , Time Factors
12.
Acute Card Care ; 9(1): 48-53, 2007.
Article in English | MEDLINE | ID: mdl-17453539

ABSTRACT

BACKGROUND: Plaque composition rather than degree of luminal narrowing may be predictive of acute coronary syndromes (ACS). The purpose of the study was to compare plaque composition and distribution with multi-slice computed tomography (MSCT) between patients presenting with either stable coronary artery disease (CAD) or ACS. METHODS: MSCT was performed in 22 and 24 patients presenting with ACS or stable CAD, respectively. Coronary lesions were classified as calcified, non-calcified or mixed while signal intensity (SI) was measured. RESULTS: In patients with stable CAD, the majority of lesions were calcified (89%). In patients with ACS, less calcifications were observed with a greater proportion of non-calcified (18%) or mixed (36%) lesions (P<0.001). Accordingly, mean SI of plaques was significantly less in ACS (320+/-201 HU versus 620+/-256 HU in stable CAD, P<0.001). Dividing lesions in the ACS group according to culprit versus non-culprit vessel location resulted in no significant difference in average SI between these two groups while still lower as compared to stable CAD (P<0.001). CONCLUSIONS: In patients with ACS, significantly less calcifications were present as compared to stable CAD. Moreover, even in non-culprit vessels, multiple non-calcified plaques were detected, indicating diffuse rather than focal atherosclerosis in ACS.


Subject(s)
Angina Pectoris/diagnostic imaging , Coronary Artery Disease/diagnostic imaging , Myocardial Infarction/diagnostic imaging , Tomography, X-Ray Computed/methods , Analysis of Variance , Angina Pectoris/pathology , Calcinosis/diagnostic imaging , Calcinosis/pathology , Case-Control Studies , Contrast Media , Coronary Artery Disease/pathology , Female , Humans , Male , Middle Aged , Myocardial Infarction/pathology , Predictive Value of Tests , Radiographic Image Interpretation, Computer-Assisted , Statistics, Nonparametric , Syndrome
13.
Eur Radiol ; 16(7): 1434-41, 2006 Jul.
Article in English | MEDLINE | ID: mdl-16498533

ABSTRACT

The purpose of this study was to assess segment image quality at high heart rates using 16-slice computed tomography and differential reconstruction for major coronary vessels. According to the following protocol, 16-slice CT coronary angiography in 46 patients with a mean heart rate of 86.3+/-11.8 was reconstructed. At three transverse planes, preview series were obtained and motion artifacts evaluated in 5% increments from 0-95% within the cardiac cycle. Relying on image quality in the previews, reconstructions were performed at three z-positions for each patient. Segment image quality was assessed in terms of artifacts and visibility. The effects of heart rate and trigger delay on image quality were analyzed. Optimal image quality was achieved at 25 to 35% of the cardiac cycle for the left circumflex (CX) and right coronary artery (RCA) or 30 to 40% for the left main (LM) and left anterior descending artery (LAD). Sixteen-slice CT and differential reconstruction produced good image quality with a low percentage of motion-degraded proximal and middle segments (8.8%). Grades were 1.5 for the LM, 1.9 for the LAD, 2.0 for the CX and 2.3 for the RCA. At high heart rates, good image quality of the coronary arteries is achieved by 16-slice CT and a sophisticated reconstruction strategy at peak to late systole.


Subject(s)
Coronary Angiography/methods , Coronary Artery Disease/diagnostic imaging , Heart Rate , Imaging, Three-Dimensional/methods , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, Spiral Computed/methods , Algorithms , Artifacts , Contrast Media , Female , Humans , Male , Middle Aged , Models, Biological , Reproducibility of Results , Retrospective Studies , Sensitivity and Specificity
14.
Int J Obes (Lond) ; 30(3): 569-73, 2006 Mar.
Article in English | MEDLINE | ID: mdl-16276363

ABSTRACT

BACKGROUND: Cardiac multislice spiral computed tomography (MSCT) scanners permit visualization of the coronary arteries with an overall good sensitivity (sens) and specificity (spec). However, in obese patients (pts), who are at higher risk to develop coronary artery disease (CAD), image quality of MSCT is supposed to be limited. At present, there are no data whether the accuracy of MSCT depends on the body mass index (BMI). Thus, we compared the catheter-controlled MSCT results from normal weight and obese pts in a cohort of 117 pts with regard to sens, spec, positive predictive value (PPV), negative predictive value (NPV) and image quality. METHODS AND MATERIAL: In all, 21 normal weight pts (group I: BMI<25, 64.6+/-11.1 years, number of risk factors 2.1+/-1.1), 60 pts with mild overweight (group II: BMI 25-30, 64.6+/-8.9 years, number of risk factors 3.4+/-1.0) and 36 obese pts (group III: BMI >30, 63.0+/-8.5 years, number of risk factors 3.4+/-0.9) were examined by MSCT (Sensation 16 Speed 4 D((R)), Siemens, Germany, gantry rotation time 375 ms) and invasive coronary angiography. MSCT results were compared blinded to the results of the coronary angiography with regard to the presence or absence of a significant stenosis (>50%) in a modified AHA 13 segment (sgt) model. Image quality was assessed on a qualitative scale between 1 (very good) and 5 (insufficient image quality) for each sgt. RESULTS: Sens, spec, PPV and NPV were statistically not different in all three groups (I: 0.88/0.97/0.91/0.96, II: 0.83/0.97/0.88/0.95, III: 0.87/0.99/0.96/0.96). 3 pts (group I 1, group II 2) had to be excluded from analysis due to technical problems. Group I had significantly less risk factors (P < 0.001) and image quality was significantly better than in group II and III (P < 0.05). Group II and III did not differ with regard to risk factors or image quality. CONCLUSIONS: Overweight and obesity have an impact on MSCT image quality but did not hamper the diagnostic accuracy. Thus, MSCT is a noninvasive method to detect or rule out CAD also in pts with higher BMI. These retrospective data have to be confirmed in larger prospective trials.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Obesity/complications , Tomography, Spiral Computed/methods , Aged , Body Mass Index , Coronary Angiography/methods , Coronary Artery Disease/etiology , Epidemiologic Methods , Female , Humans , Male , Middle Aged
16.
Heart ; 91(7): 938-41, 2005 Jul.
Article in English | MEDLINE | ID: mdl-15958366

ABSTRACT

OBJECTIVE: To evaluate image quality and clinical accuracy in detecting coronary artery lesions with a new multidetector spiral computed tomography (MDCT) generation with 16 detector slices and a temporal resolution of 188 ms. METHODS: 124 consecutive patients scheduled for invasive coronary angiography (ICA) were additionally studied by MDCT (Sensation 16 Speed 4D). MDCTs were analysed with regard to image quality and presence of coronary artery lesions. The results were compared with ICA. RESULTS: 120 of 124 scans were successful. The image quality of all remaining 120 scans was sufficient (mean (SD) heart rate 64.2 (9.8) beats/min, range 43-95). The mean calcium mass was 167 (223) mg (range 0-1038). Thirteen coronary segments were evaluated for each patient (1560 segments in total). Image quality was graded as follows: excellent, 422 (27.1%) segments; good, 540 (34.6%) segments; moderate, 277 (17.7%) segments; heavily calcified, 215 (13.8%) segments; and blurred, 106 (6.8%) segments. ICA detected 359 lesions with a diameter stenosis > 50% and MDCT detected 304 of 359 (85%). Sensitivity, specificity, and positive and negative predictive values were 85%, 98%, 91%, and 96%, respectively. The correct clinical diagnosis (presence or absence of at least one stenosis > 50%) was obtained for 110 of 120 (92%) patients. CONCLUSIONS: MDCT image quality can be further improved with 16 slices and faster gantry rotation time. These results in an unselected population underline the potential of MDCT to become a non-invasive diagnostic alternative, especially for the exclusion of coronary artery disease, in the near future.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Tomography, Spiral Computed/methods , Aged , Calcinosis/complications , Calcinosis/diagnostic imaging , Coronary Angiography/methods , Coronary Artery Bypass , Coronary Artery Disease/complications , Coronary Stenosis/complications , Coronary Stenosis/diagnostic imaging , Female , Humans , Image Processing, Computer-Assisted/methods , Male , Middle Aged , Sensitivity and Specificity , Tomography, Spiral Computed/standards
17.
Heart ; 91(11): 1423-7, 2005 Nov.
Article in English | MEDLINE | ID: mdl-15761053

ABSTRACT

OBJECTIVE: To report an initial experience with multislice spiral computed tomography (MSCT) coronary imaging, as well as differences in diagnostic accuracy between 4 slice and 16 slice MSCT technology. METHODS AND RESULTS: 210 patients underwent MSCT coronary angiography (4 slices, n = 120; 16 slices, n = 90; suspicion of coronary artery disease, n = 158; suspicion of restenosis, n = 52). Recommendations for further diagnostic tests were based on the MSCT results. Patients were interviewed by telephone after a mean (SD) of 449 (169) days to evaluate their further clinical course. MSCT detected significant lesions in 90 of 210 (43%) patients and invasive coronary angiography (ICA) was recommended. MSCT excluded significant lesions in 120 of 210 (57%) patients. ICA was actually performed in 44 of 210 (21%) patients (corresponding results, 27 of 44 (61%); false positive, 11 of 44 (25%); false negative, 6 of 44 (14%)). No significant differences were found between 4 and 16 slice imaging. No major cardiac event occurred during follow up. CONCLUSIONS: MSCT was found to be useful to evaluate the need for invasive diagnostic procedures. However, the false negative results underline that further improvements of image quality are required before MSCT can replace ICA in carefully selected patients.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Tomography, Spiral Computed/standards , Coronary Restenosis/diagnostic imaging , Female , Humans , Male , Patient Satisfaction , Risk Factors , Sensitivity and Specificity , Tomography, Spiral Computed/methods
18.
Rofo ; 177(1): 60-6, 2005 Jan.
Article in German | MEDLINE | ID: mdl-15657821

ABSTRACT

PURPOSE: The quantitative measurement of left ventricular functional parameters using multislice computed tomography (MSCT) with retrospective ECG-gating and comparison of the results with magnetic resonance imaging (MRI). MATERIALS AND METHODS: Thirty-one patients with suspected or known coronary artery disease underwent MSCT angiography with retrospective ECG-gating (Sensation 16, Siemens). Based on the CT data set, short axis reformations of the left ventricle were performed for functional analysis. On a commercially available workstation, end-diastolic- (EDV), end-systolic- (ESV), stroke volume (SV), ejection fraction (EF) and myocardial mass (MM) were calculated from MSCT (temporal resolution 105 - 210 ms) data according to the modified Simpson's rule and compared to MRI (1.5 T scanner, temporal resolution 48 ms) using a 2D TrueFISP cine sequence with respiration hold. RESULTS: In all cases, the quality was adequate for both MSCT and MRI. MSCT and MRI had an excellent correlation for EDV (r = 0.86), ESV (r = 0.91), EF (r = 0.87) and MM (r = 0.88), and a good correlation for SV (r = 0.70). The mean difference was 13.2 +/- 21.9 ml for EDV, 8.7 +/- 15.9 ml for ESV, 4.6 +/- 12.3 ml for SV, 1.4 +/- 5.2 % for EF, and 11.9 +/- 13.8 g for MM. However, EDV (p = 0.002), ESV (p = 0.005), SV (p = 0.048), and MM (p < 0.0001) were significantly overestimated with MSCT compared to MRI. For EF, no significant difference between MSCT and MRI was found (p = 0.15). CONCLUSION: For left ventricular functional parameters, MSCT of the heart with retrospective ECG-gating showed a high correlation with MRI, which has an important implication when using MSCT for non-invasive cardiac imaging. Despite the high correlation, overestimation of EDV, EVS, SV, and MM with MSCT has to be taken into account when applying this technology in clinical practice. EF was not significantly different between both modalities.


Subject(s)
Coronary Angiography , Coronary Disease/diagnosis , Coronary Disease/physiopathology , Magnetic Resonance Imaging , Stroke Volume , Tomography, Spiral Computed , Ventricular Function, Left , Aged , Coronary Disease/diagnostic imaging , Data Interpretation, Statistical , Diastole , Electrocardiography , Female , Humans , Male , Middle Aged , Systole
20.
Heart ; 90(12): 1471-5, 2004 Dec.
Article in English | MEDLINE | ID: mdl-15547032

ABSTRACT

OBJECTIVE: To evaluate the diagnostic accuracy of 16 slice computed tomography (CT) in determining plaque morphology and composition in an experimental setting. The results were compared with histopathological analysis as the reference standard. METHODS: Nine human popliteal arteries derived from amputations because of atherosclerotic disease were investigated with multislice spiral CT (MSCT). Atherosclerotic lesions were morphologically classified (completely or partially occlusive, concentric, eccentric), and tissue densities were determined within these plaques. In addition, vessel dimensions were quantitatively measured. RESULTS: The results were compared with histological analysis. The concordance index kappa for morphological classification was 0.88. Plaque density (n = 51 lesions) was significantly different (p < 0.0001) between lipid rich, fibrotic, and calcified lesions (Stary stage III: n = 2, 58 (8) Hounsfield units (HU); Stary V: n = 11, 50 (21) HU; Stary VI: n = 14, 96 (42) HU; Stary VII: n = 6, 858 (263) HU; Stary VIII: n = 18, 126 (99) HU). The concordance index kappa for the classification of plaques based on density was 0.51. Vessel dimensions had a good correlation (r = 0.98). CONCLUSIONS: 16 slice CT was found to be a reliable non-invasive imaging technique for assessing atherosclerotic plaque morphology and composition. Although calcified lesions can be differentiated from non-calcified lesions, the diagnostic accuracy in further subclassifying non-calcified plaques as lipid rich and fibrotic is low, even under experimental conditions.


Subject(s)
Coronary Artery Disease/diagnostic imaging , Popliteal Artery/diagnostic imaging , Tomography, Spiral Computed/methods , Contrast Media , Coronary Artery Disease/pathology , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...