Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Life (Basel) ; 13(7)2023 Jul 03.
Article in English | MEDLINE | ID: mdl-37511877

ABSTRACT

(1) Background: Multiple sclerosis (MS), a chronic progressive neurological disorder which affects the central nervous system (CNS), can result in disorders of all the functions controlled by the CNS: motor, sensory, cognitive and emotional. Physical therapy (PT), conducted through proprioceptive neuromuscular facilitation (PNF) techniques, can be customized to the individual patient's needs and has the potential to improve the patient's evolution. This study aims to establish if PT based on PNF techniques has a beneficial role in MS treatment. (2) Methods: We performed a prospective study on 40 patients who were diagnosed with MS and previously treated only with MS drug treatment (DT). These patients have participated in a PT program throughout one year. At the beginning and at the end of our study, after one year, we have assessed the following parameters: timed walk for 25 feet (Timed 25-Foot Walk test- T25FW test), dexterity of the upper limbs (9-Hole Peg Test-9HPT), disability level (Expanded Disability Status Scale-EDSS) and cognitive function (Paced Auditory Serial Addition Test-PASAT. (3) Results: In subjects in the early stages of MS, lower limb mobility improved significantly, T25FW decreasing from 6.46 to 5.80 (p < 0.001) and upper limb ability increased significantly in the dominant hand, 9HPT decreasing from 17.73 to 16.97 (p = 0.006) and not significantly in the non-dominant hand, 9HPT decreasing from 17.73 to 17.50 (p = 0.255). Furthermore, among these subjects, cognitive performance improved; their PASAT increased from 52.14 to 54.14 (p = 0.036), while the level of disability of these subjects improved only slightly, the EDSS scale evolving from 3.08 to 2.91 (p = 0.650). (4) Conclusions: In patients with early forms of MS, combining DT with a PT program based on PNF techniques results in: regaining muscle strength in the lower limbs, improving coordination while walking, correcting dexterity in the upper limbs and increasing the ability to concentrate.

2.
Materials (Basel) ; 14(23)2021 Nov 27.
Article in English | MEDLINE | ID: mdl-34885417

ABSTRACT

Mg-based biodegradable materials, used for medical applications, have been extensively studied in the past decades. The in vitro cytocompatibility study showed that the proliferation and viability (as assessed by quantitative MTT-assay-3-(4,5-dimethyltiazol-2-yl)-2,5-diphenyl tetrazolium bromide) were not negatively affected with time by the addition of Mn as an alloying element. In this sense, it should be put forward that the studied alloys don't have a cytotoxic effect according to the standard ISO 10993-5, i.e., the level of the cells' viability (cultured with the studied experimental alloys) attained both after 1 day and 5 days was over 82% (i.e., 82, 43-89, 65%). Furthermore, the fibroblastic cells showed variable morphology (evidenced by fluorescence microscopy) related to the alloy sample's proximity (i.e., related to the variation on the Ca, Mg, and Mn ionic concentration as a result of alloy degradation). It should be mentioned that the cells presented a polygonal morphology with large cytoplasmic processes in the vicinity of the alloy's samples, and a bipolar morphology in the remote region of the wells. Moreover, the in vitro results seem to indicate that only 0.5% Mn is sufficient to improve the chemical stability, and thus the cytocompatibility; from this point of view, it could provide some flexibility in choosing the right alloy for a specific medical application, depending on the specific parameters of each alloy, such as its mechanical properties and corrosion resistance. In order to assess the in vivo compatibility of each concentration of alloy, the pieces were implanted in four rats, in two distinct body regions, i.e., the lumbar and thigh. The body's reaction was followed over time, 60 days, both by general clinical examinations considering macroscopic changes, and by laboratory examinations, which revealed macroscopic and microscopic changes using X-rays, CT(Computed Tomography), histology exams and SEM (Scanning Electron Microscopy). In both anatomical regions, for each of the tested alloys, deformations were observed, i.e., a local reaction of different intensities, starting the day after surgery. The release of hydrogen gas that forms during Mg alloy degradation occurred immediately after implantation in all five of the groups examined, which did not affect the normal functionality of the tissues surrounding the implants. Imaging examinations (radiological and CT) revealed the presence of the alloy and the volume of hydrogen gas in the lumbar and femoral region in varying amounts. The biodegradable alloys in the Mg-Ca-Mn system have great potential to be used in orthopedic applications.

SELECTION OF CITATIONS
SEARCH DETAIL
...