Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters










Publication year range
1.
Am J Dent ; 36(3): 118-122, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37364188

ABSTRACT

PURPOSE: To investigate the effect of over-etching and subsequent use of different adhesive application approaches including active, double, preheated, and ultrasonic application on dentin bond strength. METHODS: Dentin specimens from sound human third molars were prepared and allocated into six groups (n= 10 per group). In Group 1 (negative control), the dentin specimens were over-etched with phosphoric acid for 30 seconds, and a two-step etch-and-rinse adhesive (Prime & Bond XP; Dentsply Sirona) was applied for 20 seconds according to the manufacturer's instructions. In test Groups 2-5, the application of the adhesive varied: In Group 2, the adhesive was actively rubbed into the dentin surface, whereas in Group 3, a second adhesive layer was applied after light-curing of the first one. In Group 4, the adhesive was heated to 68°C prior to application, and in Group 5, the adhesive was ultrasonically activated. Acid-etching for 15 seconds and adhesive application for 20 seconds was performed in the positive control group (Group 6) according to the manufacturer's instructions. After light-curing and composite build-up [Ceram.x Spectra ST (HV); Dentsply Sirona], microtensile bond strength and fracture types were determined. Data were statistically analyzed by Kruskal-Wallis rank test, followed by post-hoc pairwise comparisons using Conover tests and P-value adjustment according to Holm (α= 0.05). RESULTS: Active, double, preheated, or ultrasonic adhesive application showed no significant effect on dentin bond strength when compared to the control groups. Predominantly adhesive failures were observed in all groups. CLINICAL SIGNIFICANCE: A modification of adhesive application by using active, double, preheated, or ultrasonic application does not improve bonding to accidentally over-etched dentin.


Subject(s)
Dental Bonding , Dental Cements , Humans , Dentin-Bonding Agents/chemistry , Composite Resins/chemistry , Dentin , Tensile Strength , Materials Testing , Resin Cements/chemistry
2.
Clin Oral Investig ; 27(6): 3169-3180, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36869923

ABSTRACT

OBJECTIVES: To assess the behavior of dual-cure and conventional bulk-fill composite materials on real-time linear shrinkage, shrinkage stress, and degree of conversion. MATERIALS AND METHODS: Two dual-cure bulk-fill materials (Cention, Ivoclar Vivadent (with ion-releasing properties) and Fill-Up!, Coltene) and two conventional bulk-fill composites (Tetric PowerFill, Ivoclar Vivadent; SDR flow + , Dentsply Sirona) were compared to conventional reference materials (Ceram.x Spectra ST (HV), Dentsply Sirona; X-flow; Dentsply Sirona). Light curing was performed for 20 s, or specimens were left to self-cure only. Linear shrinkage, shrinkage stress, and degree of conversion were measured in real time for 4 h (n = 8 per group), and kinetic parameters were determined for shrinkage stress and degree of conversion. Data were statistically analyzed by ANOVA followed by post hoc tests (α = 0.05). Pearson's analysis was used for correlating linear shrinkage and shrinkage force. RESULTS: Significantly higher linear shrinkage and shrinkage stress were found for the low-viscosity materials compared to the high-viscosity materials. No significant difference in degree of conversion was revealed between the polymerization modes of the dual-cure bulk-fill composite Fill-Up!, but the time to achieve maximum polymerization rate was significantly longer for the self-cure mode. Significant differences in degree of conversion were however found between the polymerization modes of the ion-releasing bulk-fill material Cention, which also exhibited the significantly slowest polymerization rate of all materials when chemically cured. CONCLUSIONS: While some of the parameters tested were found to be consistent across all materials studied, heterogeneity increased for others. CLINICAL RELEVANCE: With the introduction of new classes of composite materials, predicting the effects of individual parameters on final clinically relevant properties becomes more difficult.


Subject(s)
Composite Resins , Kinetics , Polymerization , Materials Testing , Composite Resins/chemistry
3.
Nanomaterials (Basel) ; 12(21)2022 Nov 01.
Article in English | MEDLINE | ID: mdl-36364638

ABSTRACT

The aim of the study was to examine the applicability of bioactive and antibacterial nanoparticles to an experimental adhesive. The adhesive (60 wt% BisGMA, 15 wt% TEGDMA, 25 wt% HEMA) was mixed with combinations of 5 wt% methacryl-functionalized polyhedral oligomeric silsesquioxane (MA-POSS) and one kind of bioactive/antibacterial nanoparticles: 1 wt% core-shell silica-silver nanoparticle (SiO2@Ag), 1 wt% bioactive glass with bismuth (BAG-Bi) or 1 wt% calcium phosphate (CAP). Pure adhesive served as control. The physicochemical (degree of conversion (DC), linear shrinkage (LS), shear and complex viscosity, water sorption (WS), sol fraction (SF)), biological (antimicrobial effect) and bioactive (mineral precipitation) properties were investigated. DC and LS remained unchanged. The combination of BAG-Bi/MA-POSS resulted in a significantly increased WS and SF compared to control. In addition, the combination of CAP/MA-POSS slightly increased the shear viscosity of the adhesive. The addition of the nanoparticles did not influence the antimicrobial effects compared to the pure adhesive. Improved mineral inducing capacity could be detected in all nanoparticle combinations. The combination of bioactive and/or antibacterial nanoparticles showed improved mineral inducing capacity, but no antibacterial properties. The material properties were not or only slightly affected.

4.
Polymers (Basel) ; 14(16)2022 Aug 12.
Article in English | MEDLINE | ID: mdl-36015552

ABSTRACT

This study investigated polymerization kinetics, linear shrinkage, and shrinkage stress development for six contemporary composite materials of different viscosities cured using radiant exitances of 1100-2850 mW/cm2. Real-time measurements of degree of conversion, linear shrinkage, and shrinkage stress were performed over 5 min using Fourier-transform infrared spectrometry, a custom-made linometer, and a custom-made stress analyzer, respectively. For most tested variables, the factor "material" had a higher effect size than the factor "curing protocol". Maximum polymerization rate and maximum shrinkage stress rate were the most affected by changes in curing conditions. In contrast, no significant effects of curing conditions were identified within each material for shrinkage stress values measured at the end of the 5 min observation period. Linear shrinkage and shrinkage stress values measured after 5 min were closely correlated (R = 0.905-0.982). The analysis of polymerization kinetics suggested that the two composites specifically designed for rapid light-curing responded to higher radiant exitances differently than other composites. Polymerization kinetics and shrinkage stress behavior of contemporary restorative composite materials of different viscosities were overall more affected by material type than differences in curing conditions. Subtle differences in polymerization kinetics behavior shown by the two composites specifically designed for rapid high-intensity light-curing did not translate into significant differences in the development of polymerization shrinkage stress.

5.
Int J Mol Sci ; 23(15)2022 Jul 25.
Article in English | MEDLINE | ID: mdl-35897771

ABSTRACT

We embedded copper-doped mesoporous bioactive glass nanospheres (Cu-MBGN) with antibacterial and ion-releasing properties into experimental dental composites and investigated the effect of Cu-MBGN on the polymerisation properties. We prepared seven composites with a BisGMA/TEGDMA (60/40) matrix and 65 wt.% total filler content, added Cu-MBGN or a combination of Cu-MBGN and silanised silica to the silanised barium glass base, and examined nine parameters: light transmittance, degree of conversion (DC), maximum polymerisation rate (Rmax), time to reach Rmax, linear shrinkage, shrinkage stress (PSS), maximum PSS rate, time to reach maximum PSS rate, and depth of cure. Cu-MBGN without silica accelerated polymerisation, reduced light transmission, and had the highest DC (58.8 ± 0.9%) and Rmax (9.8 ± 0.2%/s), but lower shrinkage (3 ± 0.05%) and similar PSS (0.89 ± 0.07 MPa) versus the inert reference (0.83 ± 0.13 MPa). Combined Cu-MBGN and silica slowed the Rmax and achieved a similar DC but resulted in higher shrinkage. However, using a combined 5 wt.% Cu-MBGN and silica, the PSS resembled that of the inert reference. The synergistic action of 5 wt.% Cu-MBGN and silanised silica in combination with silanised barium glass resulted in a material with the highest likelihood for dental applications in future.


Subject(s)
Copper , Nanospheres , Composite Resins , Dental Materials , Kinetics , Materials Testing , Polymerization , Silicon Dioxide , Surface Properties
6.
Swiss Dent J ; 132(4): 268-269, 2022 Apr 04.
Article in German | MEDLINE | ID: mdl-35354241

ABSTRACT

Self-adhesive composites promise simplified application and reliable adhesion to dental hard tissues without prior conditioning or application of an adhesive system. Their working principle is based on specific functional monomers. Although they may reach acceptable sealing capability in minimally invasive cavities, study results showed significantly reduced bond strength to enamel and dentin compared to conventional adhesive systems. Thus, the use of self-adhesive composites requires critical individual consideration.


Subject(s)
Dental Bonding , Resin Cements , Composite Resins , Dental Bonding/methods , Dental Cements , Dentin , Materials Testing , Shear Strength
7.
Swiss Dent J ; 132(2): 122-123, 2022 Feb 07.
Article in German | MEDLINE | ID: mdl-35107004

ABSTRACT

Over the last years, bioactive glass particles have been successfully incorporated in dental restorative materials. Remineralizing effects on dental hard tissue and antibacterial properties are promising properties of these customized composites. A few materials doped with bioactive fillers are already available on the dental market. Nevertheless, further research is required to fine-tune bioactive composites for biomimetic restorative approaches.


Subject(s)
Dental Materials , Dentistry
8.
Materials (Basel) ; 14(22)2021 Nov 09.
Article in English | MEDLINE | ID: mdl-34832155

ABSTRACT

The aim of this in vitro study was to investigate the degree of C=C double bond conversion of high-viscosity dimethacrylate- or ormocer-based bulk-fill composites as a function of measurement depth. Four bulk-fill composites (Tetric EvoCeram Bulk Fill, x-tra fil, SonicFill, and Bulk Ormocer) and the conventional nanohybrid composite Tetric EvoCeram were applied in standardized Class II cavities (n = 6 per group) and photoactivated for 20 s at 1350 mW/cm2. The degree of conversion of the composites was assessed using Fourier-transform infrared spectroscopy at seven measurement depths (0.15, 1, 2, 3, 4, 5, 6 mm). Data were analyzed using repeated measures ANOVA and one-way ANOVA with Bonferroni post-hoc tests (α = 0.05). The investigated bulk-fill composites showed at least 80% of their maximum degree of conversion (80% DCmax) up to a measuring depth of at least 4 mm. Tetric EvoCeram Bulk Fill and Bulk Ormocer achieved more than 80% DCmax up to a measuring depth of 5 mm, x-tra fil up to 6 mm. The conventional nanohybrid composite Tetric EvoCeram achieved more than 80% DCmax up to 3 mm. In contrast to the conventional composite, the investigated ormocer- and dimethacrylate-based bulk-fill composites can be photo-polymerized in thick layers of up to at least 4 mm with regard to their degree of C=C double bond conversion.

9.
J Pers Med ; 11(10)2021 Oct 09.
Article in English | MEDLINE | ID: mdl-34683153

ABSTRACT

The objective of this study was to investigate the effect of individual instructions and training of dental students on the amount of applied light irradiance before and after training using a patient simulator with integrated visual feedback. Furthermore, the effect on the degree of conversion of composite restorations placed by the dental students was assessed. Forty-two dental students, split into two groups, light-cured a simulated restoration in tooth 27 of a dental patient simulator for 20 s. The irradiance (mW/cm2) received by the detector was measured in real-time before and after individual instructions and training, and the energy delivered (J/cm2) was calculated for each student. The degree of conversion at the bottom of incrementally placed composite restorations prior to individual instructions (group 1) and after individual instructions (group 2) was assessed using Fourier-transform infrared (FTIR) spectroscopy. The irradiance and degree of conversion measurements were re-assessed after all students received individual instructions. Data were analyzed using Wilcoxon signed-rank test and Mann-Whitney U-test at an overall level of significance of α = 0.05. A significant increase (p < 0.001) in applied light irradiance could be observed after individual instructions for both groups, with notably reduced data scattering. However, no significant difference was detected for the degree of conversion of placed composite restorations before or after instruction and training. Neither gender nor age of the dental students affected the obtained results. Consistent light energy delivered by dental students could be achieved through individual instructions and training with a patient simulator, also leading to less scattered irradiance results. However, the improved light-curing performance after the training did not affect the degree of conversion of the placed class II composite restorations.

10.
Materials (Basel) ; 14(7)2021 Mar 26.
Article in English | MEDLINE | ID: mdl-33810415

ABSTRACT

This study investigates the effect of defined working distances between the tip of a sandblasting device and a resin composite surface on the composite-composite repair bond strength. Resin composite specimens (Ceram.x Spectra ST (HV); Dentsply Sirona, Konstanz, Germany) were aged by thermal cycling (5000 cycles, 5-55 °C) and one week of water storage. Mechanical surface conditioning of the substrate surfaces was performed by sandblasting with aluminum oxide particles (50 µm, 3 bar, 10 s) from varying working distances of 1, 5, 10, and 15 mm. Specimens were then silanized and restored by application of an adhesive system and repair composite material (Ceram.x Spectra ST (HV)). In the negative control group, no mechanical surface pretreatment or silanization was performed. Directly applied inherent increments served as the positive control group (n = 8). After thermal cycling of all groups, microtensile repair bond strength was assessed, and surfaces were additionally characterized using scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDX). The negative control group reached the significantly lowest microtensile bond strength of all groups. No significant differences in repair bond strength were observed within the groups with varying sandblasting distances. Composite surfaces sandblasted from a distance of 1 mm or 5 mm showed no difference in repair bond strength compared to the positive control group, whereas distances of 10 or 15 mm revealed significantly higher repair bond strengths than the inherent incremental bond strength (positive control group). In conclusion, all sandblasted test groups achieved similar or higher repair bond strength than the inherent incremental bond strength, indicating that irrespective of the employed working distance between the sandblasting device and the composite substrate surface, repair restorations can be successfully performed.

11.
Article in English | MEDLINE | ID: mdl-33478112

ABSTRACT

Enzymes in toothpastes can support host immune responses, and thus maintain oral health. This study aimed to investigate gingival health and the plaque-reducing effects of enzyme-containing toothpastes. A laboratory study tested the antimicrobial potential of different enzyme-containing toothpaste formulations. Two promising formulations (enzyme-containing toothpastes with glucose oxidase and D-glucose with (C+) and without Citrox (C-) Citrox) were investigated in a clinical crossover trial (two slurries: sodium lauryl sulfate-containing (SLS), a toothpaste without SLS (reference), and water). Subjects (n = 20) abstained from toothbrushing for four days and rinsed with a toothpaste slurry. Bleeding on probing (BOP) and plaque indices (PI) were measured. A mixed linear model was used to statistically compare the slurries with respect to BOP and PI change. The in vitro bacterial growth-inhibiting evaluation showed the best results for SLS, followed by C+ and C-. The change in BOP and PI exhibited statistically significant differences to water rinsing (BOP; PI changes in % points (difference of the baseline and post-rinse values: water = 8.8%; 90.0%; C+ = -1.4%; 80.4%; SLS = 1.5%; 72.1%; reference = 0.8%; 77.5%; C- = -1.8%; 75.1%). All slurries exhibited anti-gingivitis and anti-plaque effects, resulting in a prophylactic benefit for limited-access regions during brushing.


Subject(s)
Gingivitis , Toothpastes , Double-Blind Method , Gingiva , Humans , Sodium Dodecyl Sulfate , Toothbrushing
12.
Polymers (Basel) ; 12(12)2020 Dec 03.
Article in English | MEDLINE | ID: mdl-33287394

ABSTRACT

This study investigated the effect of over-etching and prolonged application time of a universal adhesive on dentin bond strength. Ninety extracted human molars were ground to dentin and randomly allocated into nine groups (G1-9; n = 10 per group), according to the following acid etching and adhesive application times. In the control group (G1), phosphoric acid etching was performed for 15 s followed by application of the universal adhesive Scotchbond Universal (3M) for 20 s, as per manufacturer's instructions. In groups G2-5, both the etching and adhesive application times were either halved, doubled, quadrupled, or increased eightfold. In groups G6-9, etching times remained the same as in G2-5 (7.5 s, 30 s, 60 s, and 120 s, respectively), but the adhesive application time was set at 20 s as in the control group (G1). Specimens were then restored with a nanofilled composite material and subjected to microtensile bond strength testing. Bond strength data were statistically analyzed by ANOVA and Tukey's post-hoc tests (α = 0.05). The relationship of bond strength with etching and adhesive application time was examined using linear regression analysis. Treatment of dentin with halved phosphoric acid etching and adhesive application times (G2) resulted in a significant bond strength decrease compared to the control group (G1) and all other test groups, including the group with halved acid etching, but 20 s of adhesive application time (G6). No significant differences in bond strength were found for groups with multiplied etching times and an adhesive application time of 20 s or more, when compared to the control group (G1). In conclusion, a universal adhesive application time of at least 20 s is recommended when bonding to over-etched dentin.

SELECTION OF CITATIONS
SEARCH DETAIL
...