1.
Rev Med Suisse ; 20(875): 1034-1038, 2024 May 22.
Article in French | MEDLINE | ID: mdl-38783673

ABSTRACT

In up to 30-40% of the cases acute coronary syndrome (ACS) is complicated by cardiac arrhythmias. The latter can be benign or malignant and mainly occur during the first 24 hours after myocardial infarction. Ischemia time being the key factor, arrythmias decreased dramatically since the implementation of accelerated reperfusion strategies. Bradyarrhythmias are often benign and self-limiting and are less frequent than tachyarrhythmias but can sometimes require specific treatment. The objective of this article is to provide an update on bradycardia and conduction system disorders occurring during ACS and their management.


Le syndrome coronarien aigu (SCA) est compliqué d'arythmies cardiaques jusque dans 30 à 40 % des cas. Celles-ci peuvent être bénignes ou malignes et surviennent principalement durant les premières 24 heures après l'infarctus du myocarde (IDM). Le temps d'ischémie étant le facteur clé, elles sont en baisse depuis la mise en place de stratégies de reperfusion accélérées. Les bradyarythmies, souvent bénignes et spontanément résolutives, sont moins fréquentes que les tachyarythmies mais peuvent parfois nécessiter une prise en charge spécifique. L'objectif de cet article est une mise à jour sur les bradycardies et troubles de la conduction survenant lors d'un SCA ainsi que leurs prises en charge.


Subject(s)
Acute Coronary Syndrome , Bradycardia , Humans , Acute Coronary Syndrome/complications , Acute Coronary Syndrome/therapy , Acute Coronary Syndrome/diagnosis , Bradycardia/diagnosis , Bradycardia/etiology , Bradycardia/therapy
2.
Heart Rhythm ; 2024 May 13.
Article in English | MEDLINE | ID: mdl-38750909

ABSTRACT

BACKGROUND: The impact of left bundle branch area pacing (LBBAP) on right ventricular (RV) function and tricuspid regurgitation (TR) remains unclear. OBJECTIVE: We aimed to assess the long-term effects of LBBAP on RV performance and on TR. METHODS: RV function was evaluated using RV free wall strain (FWS), tricuspid annular plane systolic excursion (TAPSE), fractional area changing (FAC), and systolic (S`) velocity of the lateral tricuspid annulus. The presence of reverse septal flash (RSF) and basal bulge (BB) was used to assess RV motion pattern. The distance between the lead entry site on the interventricular septum and the septal leaflet of the tricuspid annulus was measured (lead-TV distance). RESULTS: The analysis included 122 subjects (62 males, age 76.5±11.4 years) with a median follow-up of 21 months. During follow-up, RV FWS improved significantly (15.2±5.8 vs 16.4±5.5, p < 0.001), while TAPSE, S`, and FAC remained unchanged. Left ventricular ejection fraction was an independent predictor for improved RV function (B: 3.51, CI 1.39 - 8.9, p = 0.01). With LBBAP, RSF disappeared in 22/23 (96%) patients, and BB in 15/22 (68%) patients in whom RSF and BB were present at baseline, respectively. RV function improvement was significantly higher when RSF was present at baseline (14 vs 11 patients, p = 0.02). At follow-up, no significant deterioration in TR occurred for the overall group. However, a lead-TV distance of < 24.5 mm was associated with TR progression. CONCLUSION: LBBAP has a favorable impact on RV function. A basal LBBAP position is associated with worsening TR.

3.
Europace ; 2024 May 16.
Article in English | MEDLINE | ID: mdl-38753644

ABSTRACT

BACKGROUND AND AIMS: Monitoring current of injury (COI) during left bundle branch area pacing (LBBAP) implantation is useful to evaluate lead depth. Technical aspects for recording COI amplitude have not been well studied. Our aims were to evaluate the impact of high-pass filter settings on electrogram recordings during LBBAP implantation. METHODS: Consecutive patients with successful LBBAP implantation had unipolar recordings of COI at final lead position at different high-pass filter settings (0.01Hz- 1Hz) from the tip electrode during sensing and pacing, and from the ring electrode during sensing. Duration of saturation-induced signal loss was also measured at each filter setting. COI amplitudes were compared between lumenless and stylet-driven leads. RESULTS: A total of 156 patients (96 males, aged 81.4±9.6 years) were included. Higher filter settings led to significantly lower COI amplitudes. In 50 patients with COI amplitude <10 mV, the magnitude of the drop was on average 1-1.5mV (and up to 4mV) between 0.05 Hz and 0.5 Hz meaning that cutoffs may not be used interchangeably. Saturation-induced signal loss was on average 10 s at 0.05 Hz and only 2 s with 0.5 Hz. When pacing was interrupted, the sensed COI amplitude varied (either higher or lower) by up to 4 mV, implying that it is advisable to periodically interrupt pacing to evaluate the sensed COI when reaching levels of ∼ 10 mV. Lead type did not impact COI amplitude. CONCLUSIONS: High-pass filters have a significant impact on electrogram characteristics at LBBAP implantation, with the 0.5 Hz settings having the most favourable profile.

4.
Europace ; 26(3)2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38412340

ABSTRACT

The DF-4 defibrillator standard has been rapidly adopted due to its convenience at implantation. There are however trade-offs compared to the traditional DF-1 standard that are underappreciated. This viewpoint outlines the advantages and limitations of current defibrillator lead standards that should be kept in mind, as they impact the options that are available to deal with issues that may arise.


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Heart Failure , Humans , Heart Failure/therapy
7.
Tex Heart Inst J ; 51(1)2024 01 31.
Article in English | MEDLINE | ID: mdl-38291909

ABSTRACT

BACKGROUND: Achieving optimal exposure of the mitral valve during surgical intervention poses a significant challenge. This study aimed to compare perioperative and postoperative outcomes associated with 3 left atriotomy techniques in mitral valve surgery-the conventional direct, transseptal, and superior septal approaches-and assess differences during the surgical procedure and the postoperative period. METHODS: Inclusion criteria were patients undergoing mitral valve surgery from January 2010 to December 2020, categorized into 3 cohorts: group 1 (conventional direct; n = 115), group 2 (transseptal; n = 33), and group 3 (superior septal; n = 59). To bolster sample size, the study included patients undergoing mitral valve surgery independently or in conjunction with other procedures (eg, coronary artery bypass grafting, aortictricuspid surgery, or maze procedure). RESULTS: No substantial variance was observed in the etiology of mitral valve disease across groups, except for a higher incidence of endocarditis in group 3 (P = .01). Group 1 exhibited a higher frequency of elective surgeries and isolated mitral valve procedures (P = .008), along with reduced aortic clamping and cardiopulmonary bypass durations (P = .002). Conversely, group 3 patients represented a greater proportion of emergency procedures (P = .01) and prolonged intensive care unit and hospital stays (P = .001). No significant disparities were detected in terms of permanent pacemaker implantation, postoperative complications, or mortality among the groups. CONCLUSION: Mitral valve operations that employed these 3 atriotomy techniques demonstrated a safe profile. The conventional direct approach notably reduced aortic clamping and cardiopulmonary bypass durations. The superior septal method was primarily employed for acute pathologies, with no significant escalation in postoperative arrhythmias or permanent pacemaker implantation, although these patients had prolonged intensive care unit and hospital stays. These outcomes may be linked to the underlying pathology and nature of the surgical intervention rather than the incision method itself.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Diseases , Heart Valve Prosthesis Implantation , Humans , Heart Valve Diseases/surgery , Cardiac Surgical Procedures/adverse effects , Cardiac Surgical Procedures/methods , Heart Atria/diagnostic imaging , Heart Atria/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Postoperative Period , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/methods , Treatment Outcome
8.
Eur J Heart Fail ; 26(1): 5-17, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38169072

ABSTRACT

Document Reviewers: Rudolf A. de Boer (CPG Review Co-ordinator) (Netherlands), P. Christian Schulze (CPG Review Co-ordinator) (Germany), Elena Arbelo (Spain), Jozef Bartunek (Belgium), Johann Bauersachs (Germany), Michael A. Borger (Germany), Sergio Buccheri (Sweden), Elisabetta Cerbai (Italy), Erwan Donal (France), Frank Edelmann (Germany), Gloria Färber (Germany), Bettina Heidecker (Germany), Borja Ibanez (Spain), Stefan James (Sweden), Lars Køber (Denmark), Konstantinos C. Koskinas (Switzerland), Josep Masip (Spain), John William McEvoy (Ireland), Robert Mentz (United States of America), Borislava Mihaylova (United Kingdom), Jacob Eifer Møller (Denmark), Wilfried Mullens (Belgium), Lis Neubeck (United Kingdom), Jens Cosedis Nielsen (Denmark), Agnes A. Pasquet (Belgium), Piotr Ponikowski (Poland), Eva Prescott (Denmark), Amina Rakisheva (Kazakhstan), Bianca Rocca (Italy), Xavier Rossello (Spain), Leyla Elif Sade (United States of America/Türkiye), Hannah Schaubroeck (Belgium), Elena Tessitore (Switzerland), Mariya Tokmakova (Bulgaria), Peter van der Meer (Netherlands), Isabelle C. Van Gelder (Netherlands), Mattias Van Heetvelde (Belgium), Christiaan Vrints (Belgium), Matthias Wilhelm (Switzerland), Adam Witkowski (Poland), and Katja Zeppenfeld (Netherlands) All experts involved in the development of this Focused Update have submitted declarations of interest. These have been compiled in a report and simultaneously published in a supplementary document to the Focused Update. The report is also available on the ESC website www.escardio.org/guidelines See the European Heart Journal online for supplementary documents that include evidence tables.


Subject(s)
Cardiology , Heart Failure , Humans , Heart Failure/diagnosis , Heart Failure/therapy , Poland , United Kingdom , Spain
9.
Eur Heart J ; 45(5): 346-365, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38096587

ABSTRACT

The role of cardiac implantable electronic device (CIED)-related tricuspid regurgitation (TR) is increasingly recognized as an independent clinical entity. Hence, interventional TR treatment options continuously evolve, surgical risk assessment and peri-operative care improve the management of CIED-related TR, and the role of lead extraction is of high interest. Furthermore, novel surgical and interventional tricuspid valve treatment options are increasingly applied to patients suffering from TR associated with or related to CIEDs. This multidisciplinary review article developed with electrophysiologists, interventional cardiologists, imaging specialists, and cardiac surgeons aims to give an overview of the mechanisms of disease, diagnostics, and proposes treatment algorithms of patients suffering from TR associated with CIED lead(s) or leadless pacemakers.


Subject(s)
Defibrillators, Implantable , Pacemaker, Artificial , Rheumatic Heart Disease , Tricuspid Valve Insufficiency , Humans , Pacemaker, Artificial/adverse effects , Defibrillators, Implantable/adverse effects , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/complications , Rheumatic Heart Disease/complications , Retrospective Studies
11.
medRxiv ; 2023 Dec 06.
Article in English | MEDLINE | ID: mdl-38106113

ABSTRACT

Background: Studies have reported that female sex predicts superior cardiac resynchronization therapy (CRT) response. One theory is that this association is related to smaller female heart size, thus increased "relative dyssynchrony" at given QRS durations (QRSd). Objective: To investigate the mechanisms of sex-specific CRT response relating to heart size, relative dyssynchrony, cardiomyopathy type, QRS morphology, and other patient characteristics. Methods: A post-hoc analysis of the MORE-CRT MPP trial (n=3739, 28% female), with a sub-group analysis of patients with non-ischaemic cardiomyopathy (NICM) and left bundle branch block (LBBB) (n=1308, 41% female) to control for confounding characteristics. A multivariable analysis examined predictors of response to 6 months of conventional CRT, including sex and relative dyssynchrony, measured by QRSd/LVEDV (left ventricular end-diastolic volume). Results: Females had a higher CRT response rate than males (70.1% vs. 56.8%, p<0.0001). Subgroup analysis: Regression analysis of the NICM LBBB subgroup identified QRSd/LVEDV, but not sex, as a modifier of CRT response (p<0.0039). QRSd/LVEDV was significantly higher in females (0.919) versus males (0.708, p<0.001). CRT response was 78% for female patients with QRSd/LVEDV>median value, compared to 68% < median value (p=0.012). Association between CRT response and QRSd/LVEDV was strongest at QRSd<150ms. Conclusions: In the NICM LBBB population, increased relative dyssynchrony in females, who have smaller heart sizes than their male counterparts, is a driver of sex-specific CRT response, particularly at QRSd <150ms. Females may benefit from CRT at a QRSd <130ms, opening the debate on whether sex-specific QRSd cut-offs or QRS/LVEDV measurement should be incorporated into clinical guidelines.

12.
Europace ; 26(1)2023 12 28.
Article in English | MEDLINE | ID: mdl-38153385

ABSTRACT

It is well established that right ventricular pacing is detrimental in patients with reduced cardiac function who require ventricular pacing (VP), and alternatives nowadays are comprised of biventricular pacing (BiVP) and conduction system pacing (CSP). The latter modality is of particular interest in patients with a narrow baseline QRS as it completely avoids, or minimizes, ventricular desynchronization associated with VP. In this article, experts debate whether BiVP or CSP should be used to treat these patients.


Subject(s)
Atrioventricular Block , Cardiac Resynchronization Therapy , Humans , Atrioventricular Block/diagnosis , Atrioventricular Block/therapy , Cardiac Resynchronization Therapy/adverse effects , Stroke Volume , Cardiac Conduction System Disease , Heart Conduction System
14.
Eur Heart J Suppl ; 25(Suppl G): G4-G14, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37970514

ABSTRACT

Pacing from the right ventricle is associated with an increased risk of development of congestive heart failure, increases in total and cardiac mortality, and a worsened quality of life. Conduction system pacing has become increasingly realized as an alternative to right ventricular apical pacing. Conduction system pacing from the His bundle and left bundle branch area has been shown to provide physiologic activation of the ventricle and may be an alternative to coronary sinus pacing. Conduction system pacing has been studied as an alternative for both bradycardia pacing and for heart failure pacing. In this review, we summarize the clinical results of conduction system pacing under a variety of different clinical settings. The anatomic targets of conduction system pacing are illustrated, and electrocardiographic correlates of pacing from different sites in the conduction system are defined. Ultimately, clinical trials comparing conduction system pacing with standard right ventricular apical pacing and cardiac resynchronization therapy pacing will help define its benefit and risks compared with existing techniques.

15.
Eur Heart J Suppl ; 25(Suppl G): G56-G62, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37970516

ABSTRACT

With the advent of conduction system pacing, the threshold for performing 'ablate and pace' procedures for atrial fibrillation has gone down markedly in many centres due to the ability to provide a simple and physiological means of pacing the ventricles. This article reviews the technical considerations for this strategy as well as the current evidence, recognized indications, and future perspectives.

16.
Eur Heart J Suppl ; 25(Suppl G): G1-G3, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37970520
17.
Eur Heart J Cardiovasc Imaging ; 25(1): e1-e32, 2023 Dec 21.
Article in English | MEDLINE | ID: mdl-37861372

ABSTRACT

More than 500 000 cardiovascular implantable electronic devices (CIEDs) are implanted in the European Society of Cardiology countries each year. The role of cardiovascular imaging in patients being considered for CIED is distinctly different from imaging in CIED recipients. In the former group, imaging can help identify specific or potentially reversible causes of heart block, the underlying tissue characteristics associated with malignant arrhythmias, and the mechanical consequences of conduction delays and can also aid challenging lead placements. On the other hand, cardiovascular imaging is required in CIED recipients for standard indications and to assess the response to device implantation, to diagnose immediate and delayed complications after implantation, and to guide device optimization. The present clinical consensus statement (Part 1) from the European Association of Cardiovascular Imaging, in collaboration with the European Heart Rhythm Association, provides comprehensive, up-to-date, and evidence-based guidance to cardiologists, cardiac imagers, and pacing specialists regarding the use of imaging in patients undergoing implantation of conventional pacemakers, cardioverter defibrillators, and resynchronization therapy devices. The document summarizes the existing evidence regarding the use of imaging in patient selection and during the implantation procedure and also underlines gaps in evidence in the field. The role of imaging after CIED implantation is discussed in the second document (Part 2).


Subject(s)
Cardiovascular System , Defibrillators, Implantable , Pacemaker, Artificial , Humans , Arrhythmias, Cardiac/diagnostic imaging , Arrhythmias, Cardiac/therapy , Electric Countershock , Heart
18.
Eur Heart J Cardiovasc Imaging ; 25(1): e33-e54, 2023 Dec 21.
Article in English | MEDLINE | ID: mdl-37861420

ABSTRACT

Cardiac implantable electronic devices (CIEDs) improve quality of life and prolong survival, but there are additional considerations for cardiovascular imaging after implantation-both for standard indications and for diagnosing and guiding management of device-related complications. This clinical consensus statement (part 2) from the European Association of Cardiovascular Imaging, in collaboration with the European Heart Rhythm Association, provides comprehensive, up-to-date, and evidence-based guidance to cardiologists, cardiac imagers, and pacing specialists regarding the use of imaging in patients after implantation of conventional pacemakers, cardioverter defibrillators, and cardiac resynchronization therapy (CRT) devices. The document summarizes the existing evidence regarding the role and optimal use of various cardiac imaging modalities in patients with suspected CIED-related complications and also discusses CRT optimization, the safety of magnetic resonance imaging in CIED carriers, and describes the role of chest radiography in assessing CIED type, position, and complications. The role of imaging before and during CIED implantation is discussed in a companion document (part 1).


Subject(s)
Cardiac Resynchronization Therapy , Defibrillators, Implantable , Pacemaker, Artificial , Humans , Cardiac Resynchronization Therapy/methods , Defibrillators, Implantable/adverse effects , Quality of Life , Cardiac Resynchronization Therapy Devices , Magnetic Resonance Imaging , Pacemaker, Artificial/adverse effects
19.
Pacing Clin Electrophysiol ; 46(11): 1315-1324, 2023 11.
Article in English | MEDLINE | ID: mdl-37812167

ABSTRACT

BACKGROUND: Novel pacing technologies, such as His bundle pacing (HBP) and left bundle branch area pacing (LBBaP), have emerged to maintain physiological ventricular activation. We investigated the outcomes of LBBP with HBP for patients requiring a de novo permanent pacing. METHODS AND RESULTS: Systematic review of randomized clinical trials and observational studies comparing LBBaP with HBP until March 01, 2023 was performed. Random and fixed effects meta-analyses of the effect of pacing technology on outcomes were performed. Study outcomes included pacing metrics, QRS duration, lead revision, procedure parameters, all-cause mortality and heart failure hospitalization (HFH). Overall, 10 studies with 1596 patients were included. Implant success rate was higher in LBBaP compared with HBP (RR 1.24, 95% CI: 1.08 to 1.42, p = .002). LBBaP was associated with lower capture threshold at implantation (mean difference (MD) -0.62 V, 95% CI: -0.74 to -0.51 V, p < .0001) and at follow-up (MD -0.74 V, 95% CI: -0.96 to -0.53, p < .0001), shorter procedure duration (MD -14.66 min, 95% CI: -23.54 to -5.78, p = .001) and shorter fluoroscopy time (MD -4.2 min, 95% CI: -8.4 to -0.0, p = .05). Compared with HBP, LBBaP was associated with a decreased risk of all-cause mortality (RR: 0.50, 95% CI: 0.33 to 0.77, p = .002) and HFH (RR: 0.57, 95% CI: 0.33 to 1.00, p = .05). No statistical differences were found in lead revisions and QRS duration before and after pacing. CONCLUSION: This meta-analysis found that LBBaP was superior to HBP regarding pacing metrics and implant success rate as an initial pacing strategy, although absence of head-to-head randomized comparison warrants caution in interpretation of the results.


Subject(s)
Bundle of His , Ventricular Septum , Humans , Heart Ventricles , Reoperation , Fluoroscopy , Cardiac Pacing, Artificial , Electrocardiography , Treatment Outcome
20.
Europace ; 25(10)2023 Oct 05.
Article in English | MEDLINE | ID: mdl-37766468

ABSTRACT

AIMS: Left bundle branch area pacing (LBBAP) is most often delivered using lumenless leads (LLLs), but may also be performed using stylet-driven leads (SDLs). There are limited reports on the comparison of these tools, mainly limited to reports describing initial operator experience or without detailed procedural data. Our aim was to perform an in-depth comparison of SDLs and LLLs for LBBAP at implantation and follow-up in a larger cohort of patients with experience that extends beyond that of the initial learning curve. METHODS AND RESULTS: A total of 306 consecutive patients (age 77 ± 11 years, 183 males) undergoing LBBAP implantation at a single centre were prospectively included. The population was split into two groups of 153 patients based on the initial use of an SDL (from 4 manufacturers) or an LLL. After having discounted the initial learning curve of 50 patients, there was no difference in the success rate between the initial use of lead type (96.0% with SDL vs. 94.3% with LLL, P = 0.56). There were no significant differences in success between lead models. Electrocardiogram and electrical parameters were comparable between the groups. Post-operative macro-dislodgement occurred in 4.3% of patients (essentially within the first day following implantation) and presumed micro-dislodgement with loss of conduction system capture or rise in threshold (occurring mostly during the first month) was observed in 4.7% of patients, without differences between groups. CONCLUSION: Left bundle branch area pacing may be safely and effectively performed using either LLLs or SDLs, which provides implanters with alternatives for delivering this therapy.