Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Clin Med ; 12(2)2023 Jan 04.
Article in English | MEDLINE | ID: mdl-36675354

ABSTRACT

The research aimed to evaluate the efficacy of the NeuroAssist, a parallel robotic system comprised of three robotic modules equipped with human-robot interaction capabilities, an internal sensor system for torque monitoring, and an external sensor system for real-time patient monitoring for the motor rehabilitation of the shoulder, elbow, and wrist. The study enrolled 10 consecutive patients with right upper limb paresis caused by stroke, traumatic spinal cord disease, or multiple sclerosis admitted to the Neurology I Department of Cluj-Napoca Emergency County Hospital. The patients were evaluated clinically and electrophysiologically before (T1) and after the intervention (T2). The intervention consisted of five consecutive daily sessions of 30-45 min each of 30 passive repetitive movements performed with the robot. There were significant differences (Wilcoxon signed-rank test) between baseline and end-point clinical parameters, specifically for the Barthel Index (53.00 ± 37.72 vs. 60.50 ± 36.39, p = 0.016) and Activities of Daily Living Index (4.70 ± 3.43 vs. 5.50 ± 3.80, p = 0.038). The goniometric parameters improved: shoulder flexion (70.00 ± 56.61 vs. 80.00 ± 63.59, p = 0.026); wrist flexion/extension (34.00 ± 28.75 vs. 42.50 ± 33.7, p = 0.042)/(30.00 ± 22.97 vs. 41.00 ± 30.62, p = 0.042); ulnar deviation (23.50 ± 19.44 vs. 33.50 ± 24.15, p = 0.027); and radial deviation (17.50 ± 18.14 vs. 27.00 ± 24.85, p = 0.027). There was a difference in muscle activation of the extensor digitorum communis muscle (1.00 ± 0.94 vs. 1.40 ± 1.17, p = 0.046). The optimized and dependable NeuroAssist Robotic System improved shoulder and wrist range of motion and functional scores, regardless of the cause of the motor deficit. However, further investigations are necessary to establish its definite role in motor recovery.

2.
Cancers (Basel) ; 14(23)2022 Nov 26.
Article in English | MEDLINE | ID: mdl-36497325

ABSTRACT

This paper presents a study regarding the design and the experimental setup of a medical robotic system for brachytherapy using tribology analysis. The robotic system is composed of a collaborative robotic arm and a multi-needle brachytherapy instrument controlled using a unified control system embedding a haptic device and force-feedback. This work is oriented towards identifying the technical characteristics of the system components to determine the accuracy of the procedure, as well as using different scenarios for needle insertion in ex vivo porcine liver tissue in order to determine the forces required for insertion and extraction of the needle and the friction coefficient that accompanies the previously mentioned forces. Subsequent to the computation of the friction forces, the normal forces and the wear during the needle insertion are determined with the scope of predicting the lifecycle of some components of the medical device.

3.
Healthcare (Basel) ; 10(2)2022 Feb 18.
Article in English | MEDLINE | ID: mdl-35207006

ABSTRACT

Medical robotics is a highly challenging and rewarding field of research, especially in the development of minimally invasive solutions for the treatment of the worldwide leading cause of death, cancer. The aim of the paper is to provide a design methodology for the development of a safe and efficient medical robotic system for the minimally invasive, percutaneous, targeted treatment of hepatocellular carcinoma, which can be extended with minimal modification for other types of abdominal cancers. Using as input a set of general medical requirements to comply with currently applicable standards, and a set of identified hazards and failure modes, specific methods, such as the Analytical Hierarchy Prioritization, Risk Analysis and fuzzy logic Failure Modes and Effect Analysis have been used within a stepwise approach to help in the development of a medical device targeting the insertion of multiple needles in brachytherapy procedures. The developed medical device, which is visually guided using CT scanning, has been tested for validation in a medical environment using a human-size ballistic gel liver, with promising results. These prove that the robotic system can be used for the proposed medical task, while the modular approach increases the chances of acceptance.

4.
J Pers Med ; 11(10)2021 Sep 25.
Article in English | MEDLINE | ID: mdl-34683094

ABSTRACT

The use of robotic systems in physical rehabilitation protocols has become increasingly attractive and has been given more focus in the last decade as a result of the high prevalence of motor deficits in the population, which is linked to an overburdened healthcare system. In accordance with current trends, three robotic devices have been designed, called ParReEx Elbow, ParReEx Wrist, and ASPIRE, which were designed to improve upper-limb medical recovery (shoulder, elbow, forearm, and wrist). The three automated systems were tested in a hospital setting with 23 patients (12 men and 11 women) suffering from motor deficits caused by various neurological diseases such as stroke, Parkinson's disease, and amyotrophic lateral sclerosis (ALS). The patients were divided into three groups based on their pathology (vascular, extrapyramidal, and neuromuscular). Objective clinical measures, such as the Medical Research Council (MRC) scale, goniometry, and dynamometry, were used to compare pre- and post-rehabilitation assessments for both robotic-aided and manual physical rehabilitation therapy. The results of these tests showed that, with the exception of a few minor differences in muscular strength recovery, the robotic-assisted rehabilitation methods performed equally as well as the manual techniques, though only minor improvements were validated during short-term rehabilitation. The greatest achievements were obtained in the goniometric analysis where some rehabilitation amplitudes increased by over 40% in the vascular group, but the same analysis returned regressions in the neuromuscular group. The MRC scale analysis returned no significant differences, with most regressions occurring in the neuromuscular group. The dynamometric analysis mostly returned improvements, but the highest value evolution was 19.07%, which also in the vascular group. While the results were encouraging, more research is needed with a larger sample size and a longer study period in order to provide more information regarding the efficacy of both rehabilitation methods in neurological illnesses.

5.
Article in English | MEDLINE | ID: mdl-33810042

ABSTRACT

The paper presents the design optimization of the ASPIRE spherical parallel robot for shoulder rehabilitation following clinical evaluation and clinicians' feedback. After the development of the robotic structure and the implementation of the control system, ASPIRE was prepared for clinical evaluation. A set of clinical trials was performed on 24 patients with different neurological disorders to obtain the patient and clinician acceptance of the rehabilitation system. During the clinical trials, the behavior of the robotic system was closely monitored and analyzed in order to improve its reliability and overall efficiency. Along with its reliability and efficiency, special attention was given to the safety characteristics during the rehabilitation task.


Subject(s)
Nervous System Diseases , Robotics , Stroke Rehabilitation , Humans , Reproducibility of Results
6.
Article in English | MEDLINE | ID: mdl-32916890

ABSTRACT

Motor disability is a key feature of many neurological diseases, influencing the social roles of affected patients and their ability to perform daily life activities. Current rehabilitation capacities are overwhelmed by the age-related increase of motor dysfunctions seen, for example, in stroke, extrapyramidal or neuromuscular diseases. As the patient to rehabilitation personnel ration increases, robotic solutions might establish the possibility to rapidly satisfy the increasing demand for rehabilitation. This paper presents an inaugural exploratory study which investigates the interchangeability of a novel experimental robotic rehabilitation device system with classical physical therapy, using a multimodal neurophysiological assessment of the motor system-quantitative electroencephalogram (EEG), motor conduction times and turn/amplitude analysis. Preliminary results show no significant difference between the two methods; however, a significant effect of the therapy was found on different pathologies (beneficial for vascular and extrapyramidal, or limited, and only on preventing reduction of joint movements in neuromuscular).


Subject(s)
Disabled Persons , Motor Disorders , Nervous System Diseases , Robotics , Stroke Rehabilitation , Stroke , Aged , Female , Humans , Male , Nervous System Diseases/rehabilitation
SELECTION OF CITATIONS
SEARCH DETAIL
...