Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Article in English | MEDLINE | ID: mdl-38934146

ABSTRACT

The aim of the presented prospective observational study was to evaluate the effect of fistula flow on peripheral wave morphology and pulse wave velocity by means of the oscillometric Vicorder®-device with the purpose of fistula surveillance. METHODS: Digitized and normalized curves of 53 haemodialysis patients at the fistula and non-fistula arm were analyzed. Slope parameters and the areas under the curve of characteristic sections of pulse waves as well as the power spectrum of the pulse waves and their first and second derivatives were computed. Furthermore, the amplitude of volumetric change (AMP) was assessed. Duplex-sonography served as a reference method. RESULTS: In the comprehensive set of novel pulse wave parameters significant inter-arm differences were demonstrated and a significant delay of the systolic maximum at the fistula arm in comparison to the non-fistula arm (204 ± 3.4 versus 162 ± 5.3 ms, p<0.001) was proven. Unexpectedly, pulse wave velocity apparently did not differ between both arms (7.85 versus 8.05 m/sec at the fistula/non-fistula side, p=0.942). The inter-arm differences of the slope parameters were more pronounced in forearm than in upper arm fistulas. Finally, we showed that the inter-arm difference of AMP correlated with volume-flow (r= 0.326 with p=0.017). CONCLUSION: Pulse waves as assessed by oscillometric pulse wave analysis have distinct features at fistula and non-fistula arms. This is due to enhanced arteriovenous flow, i.e. in both the brachial artery and the fistula vein. The analysis of those alterations has the potential to assess fistula function.

2.
BMC Nephrol ; 24(1): 186, 2023 06 24.
Article in English | MEDLINE | ID: mdl-37355570

ABSTRACT

BACKGROUND: Pulse wave analysis may be useful to assess fistula function. We aimed to prospectively evaluate if convenient oscillometric devices are applicable to detect flow below 500 ml/min in a real life clinical setting. METHODS: Pulse waves were recorded ambilaterally with the vicorder® device at the brachial artery in 53 patients on haemodialysis with native fistula. Primary variables consisted of the mean slope between the systolic maximum and the diacrotic notch (Slope2), the sum of the mean slopes in the four characteristic sections of pulse waves (Slope∑) and the amplitude of relative volumetric change in the measuring cuff at the upper arm (AMP). Fistula flow was measured with the use of duplex sonography using a standardized approach. RESULTS: Parameter values above or below the median indicated measurement at the non-fistula side, with sensitivities/specificities of 0.79/0.79 (p < 0.001) for Slope 2, 0.64/0.64 (p = 0.003) for Slope∑ and 0.81/0.81 (p < 0.001) for AMP if measurements at the fistula and non-fistula arm were considered. ROC-analyses of parameter values measured at the fistula to detect low flow demonstrated AUCs (with CI) of 0.652 (0.437-0.866, p = 0.167) for Slope2, 0.732 (0.566-0.899, p = 0.006) for Slope∑ and 0.775 (0.56-0.991, p = 0.012) for AMP. The point with maximal youden's index was regarded as optimal cut-off, which corresponded to sensitivities and specificities of 0.8/0.56 for slope2, 0.86/ 0.56 for Slope∑ and 0.93/0.78 for AMP. CONCLUSION: Functional surveillance with oscillometry is a promising clinical application to detect a low fistula flow. Among all investigated pulse wave parameters AMP revealed the highest diagnostic accuracy.


Subject(s)
Arteriovenous Fistula , Brachial Artery , Humans , Oscillometry , Brachial Artery/diagnostic imaging , Sensitivity and Specificity , Pulse Wave Analysis
3.
Case Rep Nephrol Dial ; 12(1): 63-72, 2022.
Article in English | MEDLINE | ID: mdl-35702378

ABSTRACT

Immunotactoid glomerulopathy (ITG) occurs infrequently and is characterized by organized IgG containing deposits. It most usually manifests as a concomitant disease of a broad spectrum of oncologic entities. We here present an exceptional case of ITG without glomerular light chain restriction secondary to a IgM kappa type monoclonal gammopathy of undetermined significance. Due to nephrotic syndrome and deterioration of kidney function a rituximab monotherapy was initiated without targeting the plasmacellular augmentation, which was confirmed as the underlying process. The treatment led to a long-term improvement of proteinuria and stabilization of glomerular filtration rate. Its therapeutic effect has to be attributed to immunomodulatory capacities and targeting of podocytes rather than to be interpreted as directed against a bone marrow or glomerular clone. We conclude that rituximab therapy may be a valuable part of the therapeutic options in ITG irrespective of the underlying oncologic entity.

4.
Kidney Blood Press Res ; 45(4): 576-588, 2020.
Article in English | MEDLINE | ID: mdl-32575106

ABSTRACT

BACKGROUND/AIMS: Pulse wave analysis (PWA) and pulse wave velocity (PWV) provide information about arterial stiffness and elasticity, which is mainly used for cardiovascular risk stratification. In the presented prospective observational pilot study, we examined the hypothesis that radiocephalic fistula (RCF)-related changes of haemodynamics and blood vessel morphology including high as well as low flow can be seen in specific changes of pulse wave (PW) morphology. METHODS: Fifty-six patients with RCF underwent local ambilateral peripheral PWA and PWV measurement with the SphygmoCor® device. Given that the output parameters of the SphygmoCor® are not relevant for the study objectives, we defined new suitable parameters for PWA in direct proximity to fistulas and established an appropriate analysing algorithm. Duplex sonography served as reference method. RESULTS: Marked changes of peripheral PW morphology when considering interarm differences of slope and areas between the fistula and non-fistula arms were observed in the Arteria radialis, A. brachialis and arterialized Vena cephalica. The sum of the slope differences was found to correlate with an increased flow, while in patients with fistula failure no changes in PW morphology were seen. Moreover, PWV was significantly reduced in the fistula arm. CONCLUSION: Beside duplex sonography, ambilateral peripheral PWA and PWV measurements are potential new clinical applications to characterize and monitor RCF function, especially in terms of high and low flow.


Subject(s)
Vascular Fistula/diagnosis , Vascular Stiffness , Adult , Aged , Blood Flow Velocity , Female , Humans , Male , Middle Aged , Pilot Projects , Prospective Studies , Pulse Wave Analysis , Vascular Fistula/physiopathology
5.
PLoS One ; 10(6): e0131465, 2015.
Article in English | MEDLINE | ID: mdl-26121389

ABSTRACT

INTRODUCTION: ABO-incompatible (ABOi) renal transplantation (RTx) from living donors is an established procedure to expand the donor pool for patients with end stage renal disease. Immunoadsorption (IA) is a standard procedure for the removal of preformed antibodies against the allograft. In this study, antigen-specific and non-antigen-specific IA in ABOi RTx were compared. PATIENTS AND METHODS: 10 patients underwent antigen-specific IA (Glycosorb group) and 13 patients non-antigen-specific IA (Immunosorba group). The effects of both procedures regarding antibody reduction, number of treatments, complications, costs, as well as the allograft function and patient survival were compared between both groups. RESULTS: Although the IgG levels were reduced equally by both procedures (p=0.82), the reduction of the IgM level was more effective in the Glycosorb group (p=0.0172). Patients in both groups required a median number of 6 IA before ABOi RTx. Allograft function at one year after AB0i RTx was similar in both groups (estimated glomerular filtration rate: 66 vs. 64 ml/min/1.73m² respectively), with a death-censored graft survival of 90.0% and 92.3% respectively. Complication rates did not differ between procedures. Due to the reuse of non-antigen-specific Immunosorba columns, costs were considerably lower in this group; however, the use of the Immunosorba-based IA was less time-efficient. CONCLUSION: Considering upcoming alternatives as simultaneous performance of dialysis and IA or a possible reuse of Glycosorb columns, this might become less relevant in the future.


Subject(s)
ABO Blood-Group System/immunology , Epitopes/immunology , Histocompatibility , Immunosorbent Techniques , Kidney Transplantation , Adult , Aged , Biopsy , Female , Humans , Immunoglobulin G/immunology , Immunoglobulin M/immunology , Immunosuppression Therapy , Kidney/pathology , Kidney Function Tests , Kidney Transplantation/adverse effects , Male , Middle Aged , Plasmapheresis , Postoperative Complications/etiology , Young Adult
6.
Nephrol Dial Transplant ; 27(10): 3807-15, 2012 Oct.
Article in English | MEDLINE | ID: mdl-23114903

ABSTRACT

BACKGROUND: May 22nd marks the beginning of a Shiga-toxin-producing Escherichia coli (STEC) O104:H4 outbreak in Northern Germany. By its end on 27 July, it had claimed 53 deaths among 2987 STEC and 855 confirmed haemolytic-uraemic syndrome (HUS) cases. METHODS: To describe short-term effectiveness of best supportive care (BSC), therapeutic plasma exchange (TPE) and TPE with eculizumab (TPE-Ecu) in 631 patients with suspected HUS treated in 84 hospitals in Germany, Sweden and the Netherlands using the web-based registry of the DGfN (online since 27 May). RESULTS: Of 631 entries, 491 fulfilled the definition of HUS (median age 46 years; 71% females). The median (inter-quartile range) hospital stay was 22 (14-31) days. Two hundred and eighty-one (57%) patients underwent dialysis and 114 (23%) mechanical ventilation. Fifty-seven patients received BSC, 241 TPE and 193 TPE-Ecu. Treatment strategy was dependent on disease severity (laboratory signs of haemolysis, thrombocytopenia, peak creatinine level, need for dialysis, neurological symptoms, frequency of seizures) which was lower in BSC than in TPE and TPE-Ecu patients. At study endpoint (hospital discharge or death), the median creatinine was lower in BSC [1.1 mg/dL (0.9-1.3)] than in TPE [1.2 mg/dL (1.0-1.5), P < 0.05] and TPE-Ecu [1.4 mg/dL (1.0-2.2), P < 0.001], while need for dialysis was not different between BSC (0.0%, n = 0), TPE (3.7%; n = 9) and TPE-Ecu (4.7%, n = 9). Seizures were absent in BSC and rare in TPE (0.4%; n = 1) and TPE-Ecu (2.6%; n = 5) patients. Total hospital mortality in HUS patients was 4.1% (n = 20) and did not differ significantly between the TPE and TPE-Ecu groups. CONCLUSIONS: Despite frequent renal impairment, advanced neurological disorders and severe respiratory failure, short-term outcome was better than expected when compared with previous reports. Within the limitations of a retrospective registry analysis, our data do not support the notion of a short-term benefit of Ecu in comparison to TPE alone in the treatment of STEC-HUS. A randomized trial comparing BSC, TPE and Ecu seems to be prudent and necessary prior to establishing new treatment guidelines for STEC-HUS.


Subject(s)
Antibodies, Monoclonal, Humanized/therapeutic use , Escherichia coli Infections/complications , Hemolytic-Uremic Syndrome/etiology , Hemolytic-Uremic Syndrome/therapy , Plasma Exchange , Shiga-Toxigenic Escherichia coli/pathogenicity , Adult , Aged , Aged, 80 and over , Epidemics , Escherichia coli Infections/epidemiology , Escherichia coli Infections/microbiology , Female , Germany/epidemiology , Hemolytic-Uremic Syndrome/mortality , Humans , Male , Middle Aged , Registries , Retrospective Studies , Treatment Outcome , Young Adult
7.
BMJ ; 345: e4565, 2012 Jul 19.
Article in English | MEDLINE | ID: mdl-22815429

ABSTRACT

OBJECTIVE: To evaluate the effect of different treatment strategies on enterohaemorrhagic Escherichia coli O104:H4 induced haemolytic uraemic syndrome. DESIGN: Multicentre retrospective case-control study. SETTING: 23 hospitals in northern Germany. PARTICIPANTS: 298 adults with enterohaemorrhagic E coli induced haemolytic uraemic syndrome. MAIN OUTCOME MEASURES: Dialysis, seizures, mechanical ventilation, abdominal surgery owing to perforation of the bowel or bowel necrosis, and death. RESULTS: 160 of the 298 patients (54%) temporarily required dialysis, with only three needing treatment long term. 37 patients (12%) had seizures, 54 (18%) required mechanical ventilation, and 12 (4%) died. No clear benefit was found from use of plasmapheresis or plasmapheresis with glucocorticoids. 67 of the patients were treated with eculizumab, a monoclonal antibody directed against the complement cascade. No short term benefit was detected that could be attributed to this treatment. 52 patients in one centre that used a strategy of aggressive treatment with combined antibiotics had fewer seizures (2% v 15%, P = 0.03), fewer deaths (0% v 5%, p = 0.029), required no abdominal surgery, and excreted E coli for a shorter duration. CONCLUSIONS: Enterohaemorrhagic E coli induced haemolytic uraemic syndrome is a severe self limiting acute condition. Our findings question the benefit of eculizumab and of plasmapheresis with or without glucocorticoids. Patients with established haemolytic uraemic syndrome seemed to benefit from antibiotic treatment and this should be investigated in a controlled trial.


Subject(s)
Anti-Bacterial Agents/therapeutic use , Antibodies, Monoclonal, Humanized/therapeutic use , Disease Outbreaks , Enterohemorrhagic Escherichia coli , Escherichia coli Infections/therapy , Hemolytic-Uremic Syndrome/therapy , Immunologic Factors/therapeutic use , Adolescent , Adult , Aged , Aged, 80 and over , Animals , Anti-Bacterial Agents/administration & dosage , Antibodies, Monoclonal, Humanized/administration & dosage , Case-Control Studies , Child , Combined Modality Therapy , Diarrhea/microbiology , Disease Progression , Drug Therapy, Combination , Escherichia coli Infections/blood , Escherichia coli Infections/epidemiology , Escherichia coli Infections/microbiology , Female , Germany/epidemiology , Glucocorticoids/administration & dosage , Glucocorticoids/therapeutic use , Hemolytic-Uremic Syndrome/blood , Hemolytic-Uremic Syndrome/epidemiology , Hemolytic-Uremic Syndrome/microbiology , Humans , Immunologic Factors/administration & dosage , Infant , L-Lactate Dehydrogenase/blood , Male , Mice , Middle Aged , Multivariate Analysis , Plasmapheresis/methods , Platelet Count , Renal Dialysis/statistics & numerical data , Respiration, Artificial/statistics & numerical data , Retrospective Studies , Treatment Outcome , Young Adult
8.
Clin Nucl Med ; 34(10): 722-4, 2009 Oct.
Article in English | MEDLINE | ID: mdl-19893414

ABSTRACT

Acute renal failure (ARF) due to bilateral parenchymal infiltration of a high grade malignant non-Hodgkin B-cell lymphoma is exceptional. Early identification of this pathology causing ARF is critical as early induction therapy with cyclophosphamide and prednisone often leads to a substantial recovery of kidney function. This striking case illustrates the usefulness of noninvasive fluoro-deoxy-glucose positron emission tomography/computed tomography as a functional imaging modality demonstrating not only the cause of unexplained ARF but also its convenience for the restaging management of non-Hodgkin lymphomas during complete remission.


Subject(s)
Acute Kidney Injury/diagnostic imaging , Acute Kidney Injury/etiology , Fluorodeoxyglucose F18 , Lymphoma, B-Cell/complications , Lymphoma, B-Cell/diagnostic imaging , Positron-Emission Tomography , Tomography, X-Ray Computed , Acute Kidney Injury/pathology , Biopsy , Female , Follow-Up Studies , Humans , Kidney/diagnostic imaging , Kidney/pathology , Kidney Neoplasms/complications , Kidney Neoplasms/diagnostic imaging , Kidney Neoplasms/pathology , Lymphoma, B-Cell/pathology , Middle Aged , Whole Body Imaging
SELECTION OF CITATIONS