Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Rev Sci Instrum ; 90(1): 013702, 2019 Jan.
Article in English | MEDLINE | ID: mdl-30709218

ABSTRACT

The Crystal Backlighter Imager (CBI) is a quasi-monochromatic, near-normal incidence, spherically bent crystal imager developed for the National Ignition Facility (NIF), which will allow inertial confinement fusion capsule implosions to be radiographed close to stagnation. This is not possible using the standard pinhole-based area-backlighter configuration, as the self-emission from the capsule hotspot overwhelms the backlighter signal in the final stages of the implosion. The CBI mitigates the broadband self-emission from the capsule hot spot by using the extremely narrow bandwidth inherent to near-normal-incidence Bragg diffraction. Implementing a backlighter system based on near-normal reflection in the NIF chamber presents unique challenges, requiring the CBI to adopt novel engineering and operational strategies. The CBI currently operates with an 11.6 keV backlighter, making it the highest energy radiography diagnostic based on spherically bent crystals to date. For a given velocity, Doppler shift is proportional to the emitted photon energy. At 11.6 keV, the ablation velocity of the backlighter plasma results in a Doppler shift that is significant compared to the bandwidth of the instrument and the width of the atomic line, requiring that the shift be measured to high accuracy and the optics aligned accordingly to compensate. Experiments will be presented that used the CBI itself to measure the backlighter Doppler shift to an accuracy of better than 1 eV. These experiments also measured the spatial resolution of CBI radiographs at 7.0 µm, close to theoretical predictions. Finally, results will be presented from an experiment in which the CBI radiographed a capsule implosion driven by a 1 MJ NIF laser pulse, demonstrating a significant (>100) improvement in the backlighter to self-emission ratio compared to the pinhole-based area-backlighter configuration.

2.
Rev Sci Instrum ; 89(8): 083504, 2018 Aug.
Article in English | MEDLINE | ID: mdl-30184717

ABSTRACT

Supra-thermal (>100 keV) electrons generated by laser plasma interactions can be detrimental to the performance of ignition experiments conducted on the National Ignition Facility (NIF). On a NIF shot, the amount of electrons is estimated by measuring the hard X-rays passing through the hohlraum wall. The primary sources of hot electrons in a hohlraum are Stimulated Raman Scattering (SRS) and two plasmon decay (TPD). While SRS is well diagnosed on the NIF, there has been no diagnosis of TPD. We have designed and implemented a new diagnostic to characterize the time history of TPD on the NIF. The instrument provides a time resolved measurement of the 3/2 ω harmonic emission which is indicative of the presence of TPD. We describe the diagnostic setup, calibration, and the preliminary results obtained on NIF hohlraum experiments. We find evidence of a correlation between measured hard X-rays generated from the hot electron bremsstrahlung and the TPD emission.

3.
Rev Sci Instrum ; 87(11): 11E316, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27910471

ABSTRACT

Current two-dimensional X-ray imaging at the National Ignition Facility (NIF) uses time resolved pinhole cameras with ∼10-25 µm pinholes. This method has limitations in the smallest resolvable features that can be imaged with reasonable photon statistics for inertial confinement fusion (ICF) applications. ICF sources have a broadband self-emission spectrum that causes the pinhole images obtained, through thin foil filters, to contain a similarly broadband spectrum complicating the interpretation of structure in the source. In order to study phenomena on the scale of ∼5 µm, such as dopant mix in the ICF capsule, a narrow energy band, higher spatial resolution microscope system with improved signal/noise has been developed using X-ray optics. Utilizing grazing incidence mirrors in a Kirkpatrick-Baez microscope (KBM) configuration [P. Kirkpatrick and A. V. Baez, J. Opt. Soc. Am. 38, 766-774 (1948)], an X-ray microscope has been designed and fielded on NIF with four imaging channels. The KBM has ∼12 × magnification, <8 µm resolution, and higher throughput in comparison to similar pinhole systems. The first KBM mirrors are coated with a multilayer mirror to allow a "narrow band" energy response at 10.2 keV with ΔE ∼ 3 keV. By adjusting the mirror coating only, the energy response can be matched to the future experimental requirements. Several mirror packs have been commissioned and are interchangeable in the diagnostic snout.

SELECTION OF CITATIONS
SEARCH DETAIL
...