Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Radiat Oncol ; 14(1): 125, 2019 Jul 11.
Article in English | MEDLINE | ID: mdl-31296245

ABSTRACT

PURPOSE: To determine the accuracy of a surface guided radiotherapy (SGRT) system for positioning of breast cancer patients in breath-hold (BH) with respect to cone-beam computed tomography (CBCT). Secondly, to evaluate the thorax position stability during BHs with SGRT, when using an air-volume guidance system. METHODS AND MATERIALS: Eighteen left-sided breast cancer patients were monitored with SGRT during CBCT and treatment, both in BH. CBCT scans were matched on the target volume and the patient surface. The setup error differences were evaluated, including with linear regression analysis. The intra-fraction variability and stability of the air-volume guided BHs were determined from SGRT measurements. The variability was determined from the maximum difference between the different BH levels within one treatment fraction. The stability was determined from the difference between the start and end position of each BH. RESULTS: SGRT data correlated well with CBCT data. The correlation was stronger for surface-to-CBCT (0.61) than target volume-to-CBCT (0.44) matches. Systematic and random setup error differences were ≤ 2 mm in all directions. The 95% limits of agreement (mean ± 2SD) were 0.1 ± 3.0, 0.6 ± 4.1 and 0.4 ± 3.4 mm in the three orthogonal directions, for the surface-to-CBCT matches. For air-volume guided BHs, the variability detected with SGRT was 2.2, 2.8 and 2.3 mm, and the stability - 1.0, 2.1 and 1.5 mm, in three orthogonal directions. Furthermore, the SGRT system could detect unexpected patient movement, undetectable by the air-volume BH system. CONCLUSION: With SGRT, left-sided breast cancer patients can be positioned and monitored continuously to maintain position errors within 5 mm. Low intra-fraction variability and good stability can be achieved with the air-volume BH system, however, additional patient position information is available with SGRT, that cannot be detected with air-volume BH systems.


Subject(s)
Brachytherapy/methods , Breast Neoplasms/radiotherapy , Breath Holding , Cone-Beam Computed Tomography/methods , Imaging, Three-Dimensional/methods , Patient Positioning , Radiotherapy, Image-Guided/methods , Female , Humans , Image Processing, Computer-Assisted/methods , Prognosis , Radiation Monitoring
2.
Radiother Oncol ; 108(2): 269-72, 2013 Aug.
Article in English | MEDLINE | ID: mdl-24055289

ABSTRACT

In 2005, we introduced hypofractionated 3-dimensional conformal radiotherapy with a simultaneous integrated boost (3D-CRT-SIB) technique after breast conserving surgery. In a consecutive series of 752 consecutive female invasive breast cancer patients (stages I-III) the 5-year actuarial rate for local control was 98.9%. This new technique gives excellent 5-year local control.


Subject(s)
Breast Neoplasms/mortality , Breast Neoplasms/radiotherapy , Neoplasm Recurrence, Local/pathology , Radiotherapy, Conformal/methods , Aged , Aged, 80 and over , Breast Neoplasms/pathology , Breast Neoplasms/surgery , Cohort Studies , Combined Modality Therapy , Confidence Intervals , Disease-Free Survival , Dose Fractionation, Radiation , Female , Follow-Up Studies , Humans , Imaging, Three-Dimensional , Mastectomy, Segmental/methods , Middle Aged , Neoplasm Invasiveness/pathology , Neoplasm Recurrence, Local/mortality , Neoplasm Recurrence, Local/therapy , Neoplasm Staging , Netherlands , Radiotherapy Dosage , Radiotherapy, Adjuvant , Retrospective Studies , Risk Assessment , Survival Analysis , Time Factors , Treatment Outcome
3.
Int J Radiat Oncol Biol Phys ; 83(4): e471-7, 2012 Jul 15.
Article in English | MEDLINE | ID: mdl-22494592

ABSTRACT

PURPOSE: To evaluate toxicity and cosmetic outcome (CO) in breast cancer survivors treated with three-dimensional conformal radiotherapy with a hypofractionated, simultaneous integrated boost (3D-CRT-SIB) and to identify risk factors for toxicity, with special focus on the impact of age. METHODS AND MATERIALS: Included were 940 consecutive disease-free patients treated for breast cancer (Stage 0-III) with 3D-CRT-SIB, after breast-conserving surgery, from 2005 to 2010. Physician-rated toxicity (Common Terminology Criteria for Adverse Events version 3.0) and CO were prospectively assessed during yearly follow-up, up to 5 years after radiotherapy. Multivariate logistic regression analyses using a bootstrapping method were performed. RESULTS: At 3 years, toxicity scores of 436 patients were available. Grade ≥ 2 fibrosis in the boost area was observed in 8.5%, non-boost fibrosis in 49.4%, pain to the chest wall in 6.7%, and fair/poor CO in 39.7% of cases. Radiotherapy before chemotherapy was significantly associated with grade ≥ 2 boost fibrosis at 3 years (odds ratio [OR] 2.8, 95% confidence interval [CI] 1.3-6.0). Non-boost fibrosis was associated with re-resection (OR 2.2, 95% CI 1.2-4.0) and larger tumors (OR 1.1, 95% CI 1.0-1.1). At 1 year, chest wall pain was significantly associated with high boost dosage (OR 2.1, 95% CI 1.2-3.7) and younger age (OR 0.4, 95% CI 0.2-0.7). A fair/poor CO was observed more often after re-resection (OR 4.5, 95% CI 2.4-8.5), after regional radiotherapy (OR 2.9, 95% CI 1.2-7.1), and in larger tumors (OR 1.1, 95% CI 1.0-1.1). CONCLUSIONS: Toxicity and CO are not impaired after 3D-CRT-SIB. Fibrosis was not significantly associated with radiotherapy parameters. Independent risk factors for fibrosis were chemotherapy after radiotherapy, re-resection, and larger tumor size. Re-resection was most predictive for worse CO. Age had an impact on chest wall pain occurrence.


Subject(s)
Breast Neoplasms/radiotherapy , Esthetics , Mastectomy, Segmental/methods , Radiotherapy, Conformal/methods , Age Factors , Antineoplastic Agents/adverse effects , Breast Neoplasms/drug therapy , Breast Neoplasms/pathology , Breast Neoplasms/surgery , Carcinoma, Intraductal, Noninfiltrating/drug therapy , Carcinoma, Intraductal, Noninfiltrating/pathology , Carcinoma, Intraductal, Noninfiltrating/radiotherapy , Carcinoma, Intraductal, Noninfiltrating/surgery , Dose Fractionation, Radiation , Female , Follow-Up Studies , Humans , Middle Aged , Odds Ratio , Prospective Studies , Radiation Injuries/pathology , Radiotherapy, Conformal/adverse effects , Regression Analysis , Retreatment , Risk Factors , Tumor Burden
4.
Radiother Oncol ; 100(2): 215-20, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21640422

ABSTRACT

PURPOSE: To report on local control and survival after breast conserving therapy (BCT) including three-dimensional conformal simultaneous integrated boost irradiation (3D-CRT-SIB) and on the influence of age on outcome. PATIENT AND METHODS: For this study, 752 consecutive female breast cancer patients (stages I-III), treated with 3D-CRT-SIB at the University Medical Center Groningen from 2005 to 2008, were retrospectively identified. Median age was 58.4 (range 26-84) years. The SIB fractionation used was: 28×1.8Gy (whole breast) and 28×2.3Gy or 2.4Gy (tumour bed). Next to outcome, we estimated the effect of age on the recurrence-free period (RFP) by multivariate Cox regression survival analysis. RESULTS: Median follow-up was 41 (range 3-65) months. Local control was 99.6% at 3 years (6 ipsilateral recurrences). The 3-year locoregional control, RFP and overall survival (OS) rates were 99.2%, 95.5%, and 97.1%, respectively. In multivariate analysis, tumours >2cm (hazard ratio (HR) 3.11; 95% confidence interval (CI) 1.57-6.17) and triple negativity (HR 3.03; 95% CI 1.37-6.67) and not age were associated with impaired RFP. CONCLUSIONS: At 3 years, the 3D-CRT-SIB technique in BCT results in excellent local control and OS. Age was not a risk factor for any recurrence.


Subject(s)
Breast Neoplasms/therapy , Dose Fractionation, Radiation , Mastectomy, Segmental , Radiotherapy, Conformal/methods , Adult , Aged , Aged, 80 and over , Breast Neoplasms/mortality , Combined Modality Therapy , Female , Humans , Middle Aged , Multivariate Analysis , Neoplasms, Second Primary/epidemiology , Radiotherapy, Conformal/adverse effects , Retrospective Studies , Treatment Failure
5.
Radiother Oncol ; 93(3): 447-53, 2009 Dec.
Article in English | MEDLINE | ID: mdl-19765847

ABSTRACT

BACKGROUND AND PURPOSE: To determine the consequences of target volume (TV) modifications, based on the additional use of PET information, on radiation planning, assuming PET/CT-imaging represents the true extent of the tumour. MATERIALS AND METHODS: For 21 patients with esophageal cancer, two separate TV's were retrospectively defined based on CT (CT-TV) and co-registered PET/CT images (PET/CT-TV). Two 3D-CRT plans (prescribed dose 50.4 Gy) were constructed to cover the corresponding TV's. Subsequently, these plans were compared for target coverage, normal tissue dose-volume histograms and the corresponding normal tissue complication probability (NTCP) values. RESULTS: The addition of PET led to the modification of CT-TV with at least 10% in 12 of 21 patients (57%) (reduction in 9, enlargement in 3). PET/CT-TV was inadequately covered by the CT-based treatment plan in 8 patients (36%). Treatment plan modifications resulted in significant changes (p<0.05) in dose distributions to heart and lungs. Corresponding changes in NTCP values ranged from -3% to +2% for radiation pneumonitis and from -0.2% to +1.2% for cardiac mortality. CONCLUSIONS: This study demonstrated that TV's based on CT might exclude PET-avid disease. Consequences are under dosing and thereby possibly ineffective treatment. Moreover, the addition of PET in radiation planning might result in clinical important changes in NTCP.


Subject(s)
Adenocarcinoma/diagnostic imaging , Adenocarcinoma/radiotherapy , Carcinoma, Squamous Cell/diagnostic imaging , Esophageal Neoplasms/diagnostic imaging , Esophageal Neoplasms/radiotherapy , Positron-Emission Tomography , Radiotherapy Planning, Computer-Assisted , Aged , Carcinoma, Squamous Cell/radiotherapy , Female , Fluorodeoxyglucose F18 , Humans , Male , Middle Aged , Radiopharmaceuticals , Radiotherapy Dosage , Radiotherapy, Conformal , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL
...