Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 19 de 19
Filter
1.
J Trauma ; 46(6): 1024-9; discussion 1029-30, 1999 Jun.
Article in English | MEDLINE | ID: mdl-10372618

ABSTRACT

BACKGROUND: Residual vertical displacement is often cited as being related to poor outcome in patients with pelvic injuries. This study attempts to clarify the relationship between residual vertical displacement and functional outcome. METHODS: From 1982 to 1989, over 500 patients with pelvic ring injuries were treated at two Level I trauma centers. Thirty-three patients with vertical shear (Tile C) fractures and residual displacement (2-52 mm) were evaluated. Outcomes were quantified by using SF-36 Short-Form Health Survey (SF-36) and the Iowa Pelvic Score (IPS). RESULTS: There was no correlation between IPS or SF-36 scales and residual vertical displacement. The IPS correlated (p<0.05) with seven of eight SF-36 categories, excluding mental health. Patients reporting limp and leg length discrepancy also correlated with the IPS and select SF-36. CONCLUSION: Pelvic injuries showed no correlation between functional outcome and residual vertical displacement suggesting other factors. The degree of residual vertical displacement does not affect functional outcome.


Subject(s)
Fractures, Bone/complications , Fractures, Bone/physiopathology , Pelvic Bones/injuries , Adolescent , Adult , Aged , Female , Fractures, Bone/therapy , Humans , Male , Middle Aged , Treatment Outcome
2.
Orthopedics ; 19(12): 1019-24, 1996 Dec.
Article in English | MEDLINE | ID: mdl-8972519

ABSTRACT

Nine high-energy pilon fractures with severe soft tissue injuries were treated by a medial external fixator with an articulated ankle-hinge and limited internal fixation (1.7 screws per case). A 100% union rate was achieved; however, there was a 100% complication rate associated with the fixator. Both B3 fractures required a vertical transarticular pin to maintain reduction. Seven C2 fractures suffered calcaneal screw loosening and drainage, necessitating removal of the fixator prior to union. Due to these complications, the articulated ankle hinge could not be utilized. At a minimum of 6 months follow up, eight of nine fractures had acceptable radiographic and early clinical results.


Subject(s)
External Fixators , Tibial Fractures/surgery , Adult , Equipment Design , External Fixators/adverse effects , Female , Fractures, Closed/surgery , Fractures, Open/surgery , Humans , Male , Middle Aged , Prospective Studies , Soft Tissue Injuries/surgery , Treatment Outcome
3.
Clin Orthop Relat Res ; (329): 152-9, 1996 Aug.
Article in English | MEDLINE | ID: mdl-8769447

ABSTRACT

Eighty patients with pelvic fractures, without hip, spine injuries with neurologic deficits, or traumatic cognitive deficits, 61% treated with external fixators, were reviewed with greater than 5 years of followup. The Short Form-36 General Health Survey, the Iowa pelvic scores, and additional questionnaires concerning return to previous sexual function, occupation, and recreation, and a perception of the worst sequelae of their pelvic trauma were administered. Fractures were classified according to Tile as 25 undisplaced Class A, 31 rotationally displaced Class B, and 24 vertically displaced Class C fractures. Injury severity scores, associated injuries, and mechanisms of injuries were similar across Tile classes. Statistical analysis compared Tile Classes A with B with C and Classes A with B and C. Variations by Tile class among the Short Form-36 survey, Iowa pelvic score, or questionnaire result's were not seen. Approximately 75% of patients returned to their previous sexual function and 80% to their previous occupation. Similarities comparing undisplaced with displaced pelvic fractures question whether reduction of pelvic ring injuries can alter patient long term functional outcomes.


Subject(s)
Fracture Fixation , Fractures, Closed/surgery , Pelvic Bones/injuries , Adolescent , Adult , Aged , Female , Fracture Fixation, Internal , Fractures, Closed/classification , Humans , Male , Middle Aged , Retrospective Studies
4.
Orthopedics ; 19(2): 109-16, 1996 Feb.
Article in English | MEDLINE | ID: mdl-8834286

ABSTRACT

Twenty-nine patients with tibial diaphyseal fractures had external fixators applied to treat their initial fractures and underwent nonreamed solid core nailing for nonunion (> 22 weeks). Fifteen Alta, 11 Lottes, and 3 Rush nails were used. The original fracture grades were: 1 closed, 1 grade I, 7 grade II, 3 grade IIIA, and 17 grade IIIB. The duration of nonunion was 51 weeks (average: 22 to 173). The average duration of external fixation was 19 weeks (range: 9 to 47). The average interval from fixator removal to nail was 32 weeks (range: 0 to 156). Twenty-eight patients were seen at > 12 months' follow up (average: 35; range: 10 to 58) and completion of treatment. Twenty-seven patients' fractures united at an average of 14 weeks (range: 6 to 40). One patient required a reamed exchange nailing at 39 weeks and united 58 weeks post-exchange nailing. One patient had a persistent asymptomatic nonunion. One patient developed a stress fracture 49 months post nail requiring an exchange nailing. Eleven fractures had a pre-nail deformity of 10 degrees or more; 9 were corrected. Eight patients had pre-nail wound and five had pre-nail pin tract infections. Except for two cases, all of these infections were treated successfully with surgical debridement and/or antibiotics prior to nail insertion. Two patients had their nail inserted through active infections that could not be controlled with an unstable fracture. One patient healed uneventfully in 6 weeks. One required two subsequent debridements. There were no other infections. The authors conclude that nonreamed solid core nailing is an acceptable treatment for tibial diaphyseal nonunions following external fixation.


Subject(s)
External Fixators , Fracture Fixation, Intramedullary/instrumentation , Fractures, Ununited/surgery , Postoperative Complications/surgery , Tibial Fractures/surgery , Adult , Aged , Female , Follow-Up Studies , Fracture Healing/physiology , Fractures, Ununited/diagnostic imaging , Humans , Male , Middle Aged , Postoperative Complications/diagnostic imaging , Radiography , Reoperation , Retrospective Studies , Surgical Wound Infection/diagnostic imaging , Surgical Wound Infection/surgery , Tibial Fractures/diagnostic imaging
5.
Clin Orthop Relat Res ; (320): 119-24, 1995 Nov.
Article in English | MEDLINE | ID: mdl-7586814

ABSTRACT

A retrospective comparison of dynamic and static locking mode nonreamed nails in 88 closed, Grades I and II open tibial fractures is presented. Amount of time and number of reoperations required to unite fractures were compared for dynamic (Group 1, n = 31) and static locked (Group 2, n = 13) Winquist I and II fractures, and dynamic (Group 3, n = 14) and static locked (Group 4, n = 30) Winquist III, IV, and segmental fractures. Total reoperations also were compared; Tibias treated with dynamic nails united in an average of 20 weeks, with 3 reoperations; tibias treated with static locked nails united in an average of 30 weeks, with 21 reoperations. Group 1 fractures united in an average of 20 weeks, with 1 reoperation; Group 2 fractures united in an average of 32 weeks, with 4 reoperations. Group 3 fractures united in an average of 20 weeks; Group 4 fractures united in an average of 29 weeks, with 11 reoperations. In the group of tibias treated with dynamic nails, 3 additional operations were done; in the group of tibias treated with static locked nails, 7 additional operations were done. There was 1 infection and 3 deformities. Static locking mode appeared to delay union, especially when Groups 1 and 2 are compared; these fractures can be nailed without locking screws.


Subject(s)
Fracture Fixation, Intramedullary/instrumentation , Tibial Fractures/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Bone Nails , Female , Fracture Healing , Humans , Male , Middle Aged , Multiple Trauma , Reoperation , Retrospective Studies , Time Factors , Wounds, Nonpenetrating/complications
6.
J Orthop Sports Phys Ther ; 21(6): 373-80, 1995 Jun.
Article in English | MEDLINE | ID: mdl-7655481

ABSTRACT

Physical therapists commonly treat injuries that occur to the foot and ankle complex following trauma. The goals of rehabilitation typically focus on restoring motion and maximizing functional strength and proprioception. It is important to understand the normal biomechanics of the foot and ankle complex as well as the structural and biomechanical changes that occur following ankle fractures, calcaneal fractures, subtalar joint dislocations, and tarsometatarsal joint dislocations. The purpose of this paper is to provide a theoretical basis for the use of various types of foot orthotics in the biomechanical treatment of traumatic foot and ankle injuries.


Subject(s)
Ankle Injuries/therapy , Foot Injuries/therapy , Fractures, Bone/therapy , Ankle Injuries/diagnostic imaging , Ankle Injuries/physiopathology , Biomechanical Phenomena , Calcaneus/injuries , Calcaneus/physiology , Foot Injuries/diagnostic imaging , Foot Injuries/physiopathology , Fractures, Bone/diagnostic imaging , Fractures, Bone/physiopathology , Humans , Metatarsal Bones/injuries , Metatarsal Bones/physiology , Orthotic Devices , Radiography , Subtalar Joint/injuries , Subtalar Joint/physiology
7.
J Orthop Trauma ; 9(1): 66-75, 1995 Feb.
Article in English | MEDLINE | ID: mdl-7714657

ABSTRACT

The efficacy of nonreamed nailing as the treatment of choice of unstable blunt tibial diaphyseal fractures was studied. From March 1, 1990, through August 31, 1991, 72 patients with 74 fractures that required fixation were treated. One patient died and six were lost to follow-up, leaving 65 patients with 67 fractures. Follow-up averaged 21 months (range 5-43). Fisher's exact and logistic regression analyses were used to compare grades of open fractures, comminution as classified by Winquist, and dynamic and static nailings. The failure rates of 51 titanium and 16 stainless steel nails were compared. Times to union were compared by the log rank statistic method. The average time to union was 32 weeks with 26 (39%) additional operations required to achieve union; 13 dynamizations (12 successful), 12 exchange nailings (11 successful), and one plate and bone graft. The rate of reconstructive procedures to achieve union was a more sensitive indicator of difficulties achieving union than was time to union. Reoperation rates were 33% for closed or grade I and II fractures compared with 46% for grade III fractures (NS). Among closed grade I and II static versus dynamic nailing, times to union were 36 versus 25 weeks (p < 0.01), and the reoperation rates were 44% versus 13% (p < 0.04). Winquist I and II fractures required a 24% reoperation rate versus 53% for grade III and IV and segmental fractures (p < 0.01). Static locked fractures required a 48% reoperation rate versus 12% for dynamic locked fractures (p < 0.01). A logistic regression analysis demonstrated that locking mode was the most important factor in determining reoperation rates. Fifteen additional reoperations for infection, broken or painful implants, or to remodel bones that united with an incomplete circumference of cortex were performed. With an additional 12 elective nail removals, the total reoperations numbered 53 (79%). Titanium alloy nails had a 2% failure rate versus 25% for stainless steel nails (p < 0.01). Two of 28 (7%) grade III fractures became infected. All fractures united within 10 degrees of normal alignment and 1 cm of length. Nine (13%) united with an incomplete cortical circumference, refractory to dynamization and full weight bearing. Thirteen of the 58 (22%) fractures available for an evaluation of ankle motion were symptomatic, with < 10 degrees of dorsiflexion.(ABSTRACT TRUNCATED AT 400 WORDS)


Subject(s)
Bone Nails , Fracture Fixation, Intramedullary/methods , Multiple Trauma/complications , Tibial Fractures/surgery , Wounds, Nonpenetrating/complications , Adolescent , Adult , Aged , Aged, 80 and over , Female , Fracture Fixation, Intramedullary/instrumentation , Humans , Male , Middle Aged , Reoperation , Tibial Fractures/complications , Treatment Outcome
8.
J Orthop Trauma ; 8(6): 494-503, 1994 Dec.
Article in English | MEDLINE | ID: mdl-7869164

ABSTRACT

The treatment and results of 13 blunt femoral fractures with an arterial injury were reviewed. Two of the 13 patients (15%) sustained segmental (two levels) arterial injuries. Stabilization of the femur fractures were performed before arterial repair in 10 of the 13 femurs. The results were determined at an average of 4.5 years. For the eight open fractures, two patients had above-knee amputations, no limb regained > 90 degrees of knee motion, four patients required a brace or cane, and three patients have intermittent wound drainage. The five closed fractures all regained full function with full knee motion. Due to the 15% incidence of segmental arterial injury, "wide-field" arteriography is advised for the evaluation of this injury. Femoral stabilization may be performed before arterial repair if the procedure does not encroach on the viability of the limb. The functional results depend on the soft-tissue damage, as illustrated by the poor results seen in open fractures.


Subject(s)
Femoral Artery/injuries , Femoral Fractures/complications , Femoral Fractures/surgery , Popliteal Artery/injuries , Adolescent , Adult , Female , Femoral Fractures/diagnostic imaging , Fractures, Closed/complications , Fractures, Closed/surgery , Fractures, Open/complications , Fractures, Open/surgery , Humans , Male , Middle Aged , Radiography , Retrospective Studies , Treatment Outcome , Wounds, Nonpenetrating/complications
9.
Orthopedics ; 17(1): 19-29, 1994 Jan.
Article in English | MEDLINE | ID: mdl-8121831

ABSTRACT

Forty acute blunt fractures of the humeral diaphysis were treated with Seidel nails (9-mm diameter) between April 1988 and August 1992. Follow up was available for 36 patients. Average Injury Severity Score (ISS) was 22. Forty-eight pelvic and lower extremity fractures necessitated humeral weight bearing in 23 patients. Patients were grouped by canal diameter measured at the point of distal humeral fixation: < or = 9 mm or > or = 10 mm. Data were analyzed with regard to complications, fracture pattern, and time to union. Due to difficulties reaming the humeral canal, five different reaming systems were used. In the < or = 9 mm group (N = 12), there were seven complications (58%). Two patients had iatrogenic comminution distal to the nail. The two open fractures in this group (II, IIIA) developed wound infections, and one, osteomyelitis. Three patients had nonunions: one was lost to follow up at 6 months, and two united at 41 and 74 weeks after exchange nailing and bone grafting. Average time to union was 21 weeks. Six of the seven complications occurred in patients who required reaming of a long, tight segment of distal canal. In the > or = 10 mm group (N = 24), there was one complication of iatrogenic comminution (4%). There were four open fractures (three, grade II; one, IIIB) with no infections. All fractures united (average = 10 weeks). The differences in complications (P = .001) and union (P = .04) between groups were significant. Other complications were not associated with canal diameter or union. There were seven radiographic failures of the distal locking device (19%). Four nails (11%) were left prominent in the shoulder due to technical or equipment failures, and were eventually removed. Four patients (11%) had residual shoulder stiffness (three due to neurologic injury). These primary data suggest use of the Seidel nail is associated with a higher complication rate in humeri with canal diameters < or = 9 mm.


Subject(s)
Fracture Fixation, Intramedullary/adverse effects , Humeral Fractures/surgery , Adolescent , Adult , Aged , Aged, 80 and over , Bone Nails , Female , Fracture Fixation, Intramedullary/methods , Humans , Humeral Fractures/diagnostic imaging , Humeral Fractures/etiology , Male , Middle Aged , Multiple Trauma/surgery , Radiography , Wounds, Gunshot/complications , Wounds, Gunshot/surgery , Wounds, Nonpenetrating/complications , Wounds, Nonpenetrating/surgery
10.
J Trauma ; 35(5): 671-5; discussion 676-7, 1993 Nov.
Article in English | MEDLINE | ID: mdl-8230327

ABSTRACT

PURPOSE: To analyze the effect on mortality of a protocol for early mobilization with external fixation of patients with pelvic ring injuries. METHODS: From 1981 through 1988, 605 patients with pelvic ring fractures and dislocations were treated. In 1982, a protocol for early external fixation of hemodynamically unstable patients and those with structurally unstable pelvic fracture patterns to achieve early mobilization to an upright chest position was initiated. Mortality rates were compared between 1981 (pre-protocol), 1982 (transitional), and 1983 through 1988, after initiation of a protocol of care that included external fixation of the pelvic injury. No statistical changes occurred from 1983 through 1988. RESULTS: Mortality rates in pelvic ring injury patients fell from 26% in 1981, to 6% in 1983 through 1988 (p < 0.001), whereas during the study period the mean injury Severity Score (ISS), 23, did not change. The mortality rate of a group of consecutive patients with comparable ISSs, but without pelvic ring injuries did not change. The mortality rate in patients with systolic blood pressure < 100 mm Hg at admission fell from 41% in 1981 to 21% 1983 through 1988 (p = 0.0001). Mortality in patients with closed head injuries associated with pelvic ring injuries fell from 43% in 1981 to 7% from 1983 through 1988 (p = 0.0001). The proportion of patients undergoing external fixation rose from 3% in 1981 to 31% in 1983 through 1988 (p = 0.0001). CONCLUSIONS: An organized protocol including external fixation and early patient mobilization to an upright chest position reduced mortality associated with injuries of the pelvic ring. Orthopedic stabilization of major skeletal injuries should be viewed as part of patient resuscitation, not reconstruction.


Subject(s)
Early Ambulation , Fracture Fixation , Fractures, Bone/mortality , Fractures, Bone/therapy , Joint Dislocations/mortality , Joint Dislocations/therapy , Pelvic Bones/injuries , Clinical Protocols , Craniocerebral Trauma/complications , Craniocerebral Trauma/mortality , External Fixators , Humans , Injury Severity Score , Multiple Trauma/complications , Multiple Trauma/mortality , Pennsylvania/epidemiology , Time Factors
11.
Orthopedics ; 16(11): 1219-23, 1993 Nov.
Article in English | MEDLINE | ID: mdl-8290395

ABSTRACT

At three institutions, 71 humeral intramedullary nails were inserted into the shoulder; 67 were reviewed at 6 months and at completion of treatment. Fifty-one utilized the anterior acromial approach and 16 were inserted lateral to the acromion. Shoulder motion was rated as: excellent (asymptomatic and within 15 degrees of normal); good (normal daily function within normal motion); and poor. Nails were also inserted into the humeral diaphysis of eight cadaver shoulders. Fifty-one nails were inserted via the anterior acromial incision; 48 were graded as excellent, one as good, and two with traumatic axillary neuropathy and reflex sympathetic dystrophy as poor: Sixteen nails were inserted lateral to the acromion; 8 were rated, 7 good, and 1 poor. Motion returned in an average of 17 weeks (range:0-29). The greatest clinical concern is not ultimate shoulder function, but the rate of return. The authors conclude that either the anterior acromial approach or an extraarticular entry portal must be utilized for antegrade humeral diaphyseal nailing.


Subject(s)
Fracture Fixation, Intramedullary/methods , Shoulder Fractures/surgery , Acromion , Fracture Fixation, Intramedullary/adverse effects , Humans , Treatment Outcome
12.
J Orthop Trauma ; 7(5): 443-9, 1993.
Article in English | MEDLINE | ID: mdl-8229381

ABSTRACT

We present a protocol for diagnosis of all femoral neck fractures associated with ipsilateral femoral diaphyseal fractures. A 30% incidence of delayed diagnosis has been reported by other investigators. Between 1982 and 1990, we have treated 32 patients with ipsilateral femoral neck and shaft fractures due to blunt trauma. Only 22 femoral neck fractures were diagnosed on prediaphyseal fixation radiographs. This left the 10 patients in this study who had normal prediaphyseal fixation radiographs and were subsequently found to have femoral neck fractures. The ipsilateral femoral neck fractures were found through a retrospective chart and radiographic review of all 555 femoral diaphyseal fractures identified through our trauma and fracture registries. The clinical and radiologic techniques for diagnosing the femoral neck fractures were presented. The time to union of the femoral shaft and neck was determined, and a preliminary radiologic assessment of the vascularity of the femoral head was made. Ten femoral neck fractures (31%) with normal preoperative radiographs were diagnosed after femoral diaphyseal fixation. One patient did not have a post-diaphyseal fixation radiograph. An incidental radiograph at 6 weeks showed a mildly displaced femoral neck fracture in an asymptomatic patient. At 16 weeks the patient became symptomatic, and a repeat radiograph showed the fracture. Five fractures were diagnosed in asymptomatic patients on routine post-femoral fixation radiographs. Two patients had normal post-femoral fixation radiographs, became symptomatic, and had their femoral neck fractures diagnosed on repeat radiographs at 3 and 7 days. One patient had normal pre- and postfixation radiographs, and on a 25-day routine femoral radiograph, the femoral neck fracture was diagnosed.(ABSTRACT TRUNCATED AT 250 WORDS)


Subject(s)
Femoral Fractures/complications , Femoral Neck Fractures/diagnosis , Femoral Neck Fractures/therapy , Adolescent , Adult , Clinical Protocols , Female , Femoral Fractures/therapy , Femoral Neck Fractures/diagnostic imaging , Femoral Neck Fractures/etiology , Humans , Male , Middle Aged , Radiography , Retrospective Studies , Wounds, Nonpenetrating/complications
13.
J Orthop Trauma ; 7(3): 279-85, 1993.
Article in English | MEDLINE | ID: mdl-8326435

ABSTRACT

From July 1982 to March 1990, 32 patients had an external fixator applied to treat a tibial diaphyseal fracture and subsequently underwent intramedullary nailing: 16 with reamed and 16 with nonreamed solid core nails. Indications for surgery were 12 atrophic and 1 hypertrophic nonunion in each group. The balance were either planned conversions or inadequate external fixators due to head injuries. All but one were seen by an author at a minimum of 1 year. Among the reamed nails, 3 fractures were grade III B. Two patients had pin tract infections, and there were no prenail wound infections. All infections were clinically inactive at the time of nail insertion. Postnail, 7 patients became infected, requiring 12 debridements and 2 procedures to achieve union. One patient had a plate applied 44 weeks postnail and was lost 48 weeks postnail with a persistent infected nonunion. The average time to union was 26 weeks. In the nonreamed solid core group, 2 fractures were grade III A and 5 grade III B. There were 2 pin and 5 prenail wound infections. One nail was inserted across an active pin tract infection. One tibia became infected postnail (p = .04). The fractures united at an average of 14 weeks postnail (p = .036). Two debridements to control infection but no further procedures to achieve union were necessary (p = .003). When tibial reconstructions following external fixation are required, nonreamed solid core nails are efficacious and may be preferable to reamed nails.


Subject(s)
Bone Nails , External Fixators , Fracture Fixation, Intramedullary/instrumentation , Tibial Fractures/surgery , Adolescent , Adult , Debridement , Female , Fractures, Ununited/surgery , Humans , Male , Middle Aged , Prosthesis Design , Prosthesis-Related Infections/surgery , Wound Infection/surgery
14.
Orthopedics ; 15(8): 907-16, 1992 Aug.
Article in English | MEDLINE | ID: mdl-1508766

ABSTRACT

From January 1982 through December 1988, 150 patients with 153 Winquist Class III and IV comminuted diaphyseal femur fractures due to high energy blunt trauma were treated with immediate plate fixation. A total of 260 major general surgical systems were injured in 150 patients. Forty-nine patients did not have adequate preoperative spine radiographs due to positioning or time factors. Nineteen patients had spine fractures; nine were diagnosed post-femoral fixation. The average injury severity score (ISS) was 22.7. Three patients died (2%). Our institution predicted mortality with this ISS for patients without pelvic or femur fractures at 15% (P = .0003). Six patients moved to other states and three were lost to follow up due to noncompliance. One of us reviewed 141 fractures in 138 patients at a minimum of 12 months follow up and completion of treatment. Forty-nine fractures were open; 8 grade I, 25 grade II, 10 grade IIIA, 4 IIIB, 2 IIIC. A total of 153 pelvic or ipsilateral major orthopedic injuries were present in 141 fractures. An additional 188 major associated orthopedic injuries were noted. The average time to union was 17.2 weeks. One plate was applied in 11 degrees of varus. Five plates failed from fatigue and five from repeat traumas. Seven plate failures were rodded and healed within 8 weeks. There was one persistent nonunion. One fracture, open IIIC, became infected after uniting. One patient has 110 degrees of knee motion and 140 fractures have greater than 130 degrees of knee motion. Plate fixation is a safe technique for immediate femoral stabilization in the face of high energy blunt trauma. Failures occur late and are easy to reconstruct. Intramedullary nails are the preferred method of reconstruction. Ultimate knee function is excellent. Infection rates (1/49) in open fractures are acceptably low.


Subject(s)
Femoral Fractures/surgery , Fracture Fixation, Intramedullary/methods , Multiple Trauma/surgery , Adult , Bone Nails , Femoral Fractures/complications , Femoral Fractures/diagnostic imaging , Femur/diagnostic imaging , Humans , Injury Severity Score , Radiography , Time Factors , Treatment Outcome , Wounds, Nonpenetrating/surgery
15.
Orthopedics ; 14(3): 239-46, 1991 Mar.
Article in English | MEDLINE | ID: mdl-2020623

ABSTRACT

Forty-two humeral diaphyseal fractures in 41 patients were treated at three centers between April 1988 and November 1989. There were 28 acute fractures; four were open. Average time to union was 8 weeks. There were no infections. Six patients with seven pathologic fractures due to metastatic disease died during the course of this study, but the nail had allowed them to be functional with minimal surgical dissection. Five of six nonunions united with one procedure. There was one residual nonunion in a patient with a wide canal and an arthrodesed shoulder above the nonunion. There were three preoperative radial and two preoperative axillary nerve palsies, and no iatrogenic nerve palsies. In all patients with anterior deltoid incisions, shoulder motion returned reliably, but took as long as 6 months. Four rods were left prominent in the rotator cuff and the patients had symptoms of impingement until rod removal. Six patients had restricted shoulder function, one due to a fracture of the humeral head and five from a lateral deltoid incision. This incision was used in 12 cases. There were no stiff shoulders when using an anterior deltoid incision.


Subject(s)
Fracture Fixation, Intramedullary , Humeral Fractures/surgery , Adult , Aged , Bone Nails , Female , Fracture Fixation, Intramedullary/instrumentation , Fractures, Closed/surgery , Fractures, Open/surgery , Humans , Humeral Fractures/diagnostic imaging , Male , Middle Aged , Prosthesis Design , Radiography , Range of Motion, Articular , Shoulder Joint/physiology
16.
Skeletal Radiol ; 20(4): 251-4, 1991.
Article in English | MEDLINE | ID: mdl-1853215

ABSTRACT

A total of 304 patients with injuries to the femoral shaft and ipsilateral hip presented between 1984 and 1990. Some 253 of them suffered fractures of the femoral shaft and dislocated hips or fractures of the acetabulum, and 51 of these sustained fractures of the femoral shaft and neck or trochanteric region. Of this latter group, 20 patients had a combination of femoral shaft and neck fractures, and 31 had a combination of femoral shaft and trochanteric fractures. All of the trochanteric injuries were demonstrated on the initial radiographs. However, in 11 of the patients with combined femoral shaft and neck fractures, the diagnosis was delayed by as much as 4 weeks. This delay related to the fact that these fractures tended not to separate in the initial evaluation period and that there was external rotation of the proximal femoral fragment due to the femoral shaft fracture. Good preoperative and, in particular, good postoperative radiography of the hip is essential to make the diagnosis. Although orthopedic surgeons have been aware of this combination of injuries since 1953, radiologists have not.


Subject(s)
Femoral Fractures/complications , Femoral Neck Fractures/complications , Adult , Female , Femoral Fractures/diagnostic imaging , Femoral Fractures/surgery , Femoral Neck Fractures/diagnostic imaging , Femoral Neck Fractures/surgery , Fracture Fixation, Internal , Hip Fractures/complications , Hip Fractures/diagnostic imaging , Hip Fractures/surgery , Humans , Male , Radiography
17.
J Orthop Trauma ; 5(4): 392-4, 1991.
Article in English | MEDLINE | ID: mdl-1761998

ABSTRACT

The abduction lordotic view is a previously unreported radiographic technique for visualization of the clavicle. Use of this technique, a simple office procedure, combined with a standard anteroposterior view allows almost 90 degrees visualization of the clavicle. It is recommended particularly for the assessment of clavicular healing.


Subject(s)
Clavicle/diagnostic imaging , Fractures, Bone/diagnostic imaging , Technology, Radiologic , Clavicle/injuries , Fractures, Bone/surgery , Humans , Posture , Radiography
18.
J Orthop Trauma ; 5(4): 469-74, 1991.
Article in English | MEDLINE | ID: mdl-1762010

ABSTRACT

A study was undertaken to review the results of donor site morbidity of cancellous bone grafts obtained from the proximal tibial metaphysis. Two hundred six patients who underwent 230 proximal tibial bone graft harvestings were reviewed. Patients with lower-extremity fractures or nonunions who required cancellous bone grafts and would be non-weight-bearing for at least 6 weeks were selected to undergo the procedure. Minimum length of follow-up was 4 months, with an average length of follow up of 20.4 months. The proximal tibial metaphysis was found to supply an adequate amount of graft for all procedures involved, with a complication rate related to graft donor site of 1.3%. This compares favorably to a previously published report on bone grafts taken primarily from the iliac crest. The postoperative appearance of the proximal tibia may be permanently altered by the procedure, but weight-bearing after 6 weeks appears safe. The proximal tibial metaphysis is a useful site for obtaining cancellous bone graft and is associated with a low morbidity.


Subject(s)
Bone Transplantation , Fractures, Bone/surgery , Tibia/transplantation , Transplantation, Autologous , Fractures, Bone/diagnostic imaging , Fractures, Bone/physiopathology , Humans , Postoperative Complications/etiology , Radiography , Retrospective Studies , Tissue and Organ Procurement/methods , Wound Healing
19.
SELECTION OF CITATIONS
SEARCH DETAIL
...