Article in English | MEDLINE | ID: mdl-29623248

ABSTRACT

Interstitial lung diseases (ILD) involve several abnormal imaging patterns observed in computed tomography (CT) images. Accurate classification of these patterns plays a significant role in precise clinical decision making of the extent and nature of the diseases. Therefore, it is important for developing automated pulmonary computer-aided detection systems. Conventionally, this task relies on experts' manual identification of regions of interest (ROIs) as a prerequisite to diagnose potential diseases. This protocol is time consuming and inhibits fully automatic assessment. In this paper, we present a new method to classify ILD imaging patterns on CT images. The main difference is that the proposed algorithm uses the entire image as a holistic input. By circumventing the prerequisite of manual input ROIs, our problem set-up is significantly more difficult than previous work but can better address the clinical workflow. Qualitative and quantitative results using a publicly available ILD database demonstrate state-of-the-art classification accuracy under the patch-based classification and shows the potential of predicting the ILD type using holistic image.

2.
Tomography ; 3(2): 114-122, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28856247

ABSTRACT

We present a new image quality assessment method for determining whether reducing radiation dose impairs the image quality of computed tomography (CT) in qualitative and quantitative clinical analyses tasks. In this Institutional Review Board-exempt study, we conducted a review of 50 patients (male, 22; female, 28) who underwent reduced-dose CT scanning on the first follow-up after standard-dose multiphase CT scanning. Scans were for surveillance of von Hippel-Lindau disease (N = 26) and renal cell carcinoma (N = 10). We investigated density, morphometric, and structural differences between scans both at tissue (fat, bone) and organ levels (liver, heart, spleen, lung). To quantify structural variations caused by image quality differences, we propose using the following metrics: dice similarity coefficient, structural similarity index, Hausdorff distance, gradient magnitude similarity deviation, and weighted spectral distance. Pearson correlation coefficient and Welch 2-sample t test were used for quantitative comparisons of organ morphometry and to compare density distribution of tissue, respectively. For qualitative evaluation, 2-sided Kendall Tau test was used to assess agreement among readers. Both qualitative and quantitative evaluations were designed to examine significance of image differences for clinical tasks. Qualitative judgment served as an overall assessment, whereas detailed quantifications on structural consistency, intensity homogeneity, and texture similarity revealed more accurate and global difference estimations. Qualitative and quantitative results indicated no significant image quality degradation. Our study concludes that low(er)-dose CT scans can be routinely used because of no significant loss in quantitative image information compared with standard-dose CT scans.

SELECTION OF CITATIONS
SEARCH DETAIL
...