Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
2.
Nat Methods ; 6(8): 593-5, 2009 Aug.
Article in English | MEDLINE | ID: mdl-19620973

ABSTRACT

We synthesized reversible terminators with tethered inhibitors for next-generation sequencing. These were efficiently incorporated with high fidelity while preventing incorporation of additional nucleotides, and we used them to sequence canine bacterial artificial chromosomes in a single-molecule system that provided even coverage for over 99% of the region sequenced. This single-molecule approach generated high-quality sequence data without the need for target amplification and thus avoided concomitant biases.


Subject(s)
Chromosomes, Artificial, Bacterial/chemistry , DNA/chemistry , Nucleotides/chemistry , Sequence Analysis, DNA/methods , Animals , Chromatography, High Pressure Liquid , Chromosomes, Artificial, Bacterial/genetics , Computer Simulation , Dogs , Nucleotides/genetics , Sensitivity and Specificity , Substrate Specificity
3.
Genome Res ; 14(9): 1749-55, 2004 Sep.
Article in English | MEDLINE | ID: mdl-15310656

ABSTRACT

We have developed and genotyped >15,000 SNP assays by using a primer extension genotyping assay with fluorescence polarization (FP) detection. Although the 80% success rate of this assay is similar to those of other SNP genotyping assays, we wanted to determine the reasons for the failures and find ways to improve the assay. We observed that the failed assays fell into three general patterns: PCR failure, excess of heterozygous genotypes, and loss of FP signal for one of the dye labels. After analyzing several hundred failed assays, we concluded that 5% of the assays had PCR failure and had to be redesigned. We also discovered that the other two categories of failures were due to misincorporation of one of the dye-terminators during the primer extension reaction as a result of primer shortening with a reverse reaction involving inorganic pyrophosphate, and to the quenching of R110-terminator after its incorporation onto the SNP primer. The relatively slow incorporation of R110 acycloterminators by AcycloPol compounds the problem with the R110 label. In this report, we describe the source of the problems and simple ways to correct these problems by adding pyrophosphatase, using quenching as part of the analysis, and replacing R110 by Texas red as one of the dye labels. With this new protocol, we have achieved approximately 95% success rate in assay development without the need for optimization.


Subject(s)
DNA Primers/chemistry , Diphosphates/metabolism , Fluorescence Polarization/methods , Polymorphism, Single Nucleotide/genetics , Alkaline Phosphatase , Genetic Testing , Genotype , Heterozygote , Humans , Polymerase Chain Reaction
SELECTION OF CITATIONS
SEARCH DETAIL
...