1.
Anaesthesia ; 79(2): 156-167, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37921438

ABSTRACT

It is unclear if cardiopulmonary resuscitation is an aerosol-generating procedure and whether this poses a risk of airborne disease transmission to healthcare workers and bystanders. Use of airborne transmission precautions during cardiopulmonary resuscitation may confer rescuer protection but risks patient harm due to delays in commencing treatment. To quantify the risk of respiratory aerosol generation during cardiopulmonary resuscitation in humans, we conducted an aerosol monitoring study during out-of-hospital cardiac arrests. Exhaled aerosol was recorded using an optical particle sizer spectrometer connected to the breathing system. Aerosol produced during resuscitation was compared with that produced by control participants under general anaesthesia ventilated with an equivalent respiratory pattern to cardiopulmonary resuscitation. A porcine cardiac arrest model was used to determine the independent contributions of ventilatory breaths, chest compressions and external cardiac defibrillation to aerosol generation. Time-series analysis of participants with cardiac arrest (n = 18) demonstrated a repeating waveform of respiratory aerosol that mapped to specific components of resuscitation. Very high peak aerosol concentrations were generated during ventilation of participants with cardiac arrest with median (IQR [range]) 17,926 (5546-59,209 [1523-242,648]) particles.l-1 , which were 24-fold greater than in control participants under general anaesthesia (744 (309-2106 [23-9099]) particles.l-1 , p < 0.001, n = 16). A substantial rise in aerosol also occurred with cardiac defibrillation and chest compressions. In a complimentary porcine model of cardiac arrest, aerosol recordings showed a strikingly similar profile to the human data. Time-averaged aerosol concentrations during ventilation were approximately 270-fold higher than before cardiac arrest (19,410 (2307-41,017 [104-136,025]) vs. 72 (41-136 [23-268]) particles.l-1 , p = 0.008). The porcine model also confirmed that both defibrillation and chest compressions generate high concentrations of aerosol independent of, but synergistic with, ventilation. In conclusion, multiple components of cardiopulmonary resuscitation generate high concentrations of respiratory aerosol. We recommend that airborne transmission precautions are warranted in the setting of high-risk pathogens, until the airway is secured with an airway device and breathing system with a filter.


Subject(s)
Cardiopulmonary Resuscitation , Out-of-Hospital Cardiac Arrest , Humans , Animals , Swine , Cardiopulmonary Resuscitation/methods , Out-of-Hospital Cardiac Arrest/therapy , Heart , Respiration , Exhalation
2.
Anaesthesia ; 77(1): 22-27, 2022 01.
Article in English | MEDLINE | ID: mdl-34700360

ABSTRACT

Manual facemask ventilation, a core component of elective and emergency airway management, is classified as an aerosol-generating procedure. This designation is based on one epidemiological study suggesting an association between facemask ventilation and transmission during the SARS-CoV-1 outbreak in 2003. There is no direct evidence to indicate whether facemask ventilation is a high-risk procedure for aerosol generation. We conducted aerosol monitoring during routine facemask ventilation and facemask ventilation with an intentionally generated leak in anaesthetised patients. Recordings were made in ultraclean operating theatres and compared against the aerosol generated by tidal breathing and cough manoeuvres. Respiratory aerosol from tidal breathing in 11 patients was reliably detected above the very low background particle concentrations with median [IQR (range)] particle counts of 191 (77-486 [4-1313]) and 2 (1-5 [0-13]) particles.l-1 , respectively, p = 0.002. The median (IQR [range]) aerosol concentration detected during facemask ventilation without a leak (3 (0-9 [0-43]) particles.l-1 ) and with an intentional leak (11 (7-26 [1-62]) particles.l-1 ) was 64-fold (p = 0.001) and 17-fold (p = 0.002) lower than that of tidal breathing, respectively. Median (IQR [range]) peak particle concentration during facemask ventilation both without a leak (60 (0-60 [0-120]) particles.l-1 ) and with a leak (120 (60-180 [60-480]) particles.l-1 ) were 20-fold (p = 0.002) and 10-fold (0.001) lower than a cough (1260 (800-3242 [100-3682]) particles.l-1 ), respectively. This study demonstrates that facemask ventilation, even when performed with an intentional leak, does not generate high levels of bioaerosol. On the basis of this evidence, we argue facemask ventilation should not be considered an aerosol-generating procedure.


Subject(s)
Masks , Respiratory Aerosols and Droplets/chemistry , Adult , Aged , Cough/etiology , Female , Humans , Male , Middle Aged , Severe acute respiratory syndrome-related coronavirus/isolation & purification , Severe Acute Respiratory Syndrome/pathology , Severe Acute Respiratory Syndrome/virology
3.
Anaesthesia ; 76(12): 1577-1584, 2021 12.
Article in English | MEDLINE | ID: mdl-34287820

ABSTRACT

Many guidelines consider supraglottic airway use to be an aerosol-generating procedure. This status requires increased levels of personal protective equipment, fallow time between cases and results in reduced operating theatre efficiency. Aerosol generation has never been quantitated during supraglottic airway use. To address this evidence gap, we conducted real-time aerosol monitoring (0.3-10-µm diameter) in ultraclean operating theatres during supraglottic airway insertion and removal. This showed very low background particle concentrations (median (IQR [range]) 1.6 (0-3.1 [0-4.0]) particles.l-1 ) against which the patient's tidal breathing produced a higher concentration of aerosol (4.0 (1.3-11.0 [0-44]) particles.l-1 , p = 0.048). The average aerosol concentration detected during supraglottic airway insertion (1.3 (1.0-4.2 [0-6.2]) particles.l-1 , n = 11), and removal (2.1 (0-17.5 [0-26.2]) particles.l-1 , n = 12) was no different to tidal breathing (p = 0.31 and p = 0.84, respectively). Comparison of supraglottic airway insertion and removal with a volitional cough (104 (66-169 [33-326]), n = 27), demonstrated that supraglottic airway insertion/removal sequences produced <4% of the aerosol compared with a single cough (p < 0.001). A transient aerosol increase was recorded during one complicated supraglottic airway insertion (which initially failed to provide a patent airway). Detailed analysis of this event showed an atypical particle size distribution and we subsequently identified multiple sources of non-respiratory aerosols that may be produced during airway management and can be considered as artefacts. These findings demonstrate supraglottic airway insertion/removal generates no more bio-aerosol than breathing and far less than a cough. This should inform the design of infection prevention strategies for anaesthetists and operating theatre staff caring for patients managed with supraglottic airways.


Subject(s)
Airway Extubation/standards , Environmental Monitoring/standards , Intubation, Intratracheal/standards , Operating Rooms/standards , Particle Size , Supraglottitis/therapy , Airway Extubation/methods , Airway Management/methods , Airway Management/standards , Cough/therapy , Environmental Monitoring/methods , Humans , Intubation, Intratracheal/methods , Operating Rooms/methods , Personal Protective Equipment/standards , Prospective Studies
4.
J Hosp Infect ; 110: 194-200, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33549768

ABSTRACT

BACKGROUND: Reducing COVID-19 transmission relies on controlling droplet and aerosol spread. Fluorescein staining reveals microscopic droplets. AIM: To compare the droplet spread in non-laminar and laminar air flow operating theatres. METHODS: A 'cough-generator' was fixed to a theatre trolley at 45°. Fluorescein-stained 'secretions' were projected on to a series of calibrated targets. These were photographed under UV light and 'source detection' software measured droplet splatter size and distance. FINDINGS: The smallest droplet detected was ∼120 µm and the largest ∼24,000 µm. An average of 25,862 spots was detected in the non-laminar theatre, compared with 11,430 in the laminar theatre (56% reduction). The laminar air flow mainly affected the smaller droplets (<1000 µm). The surface area covered with droplets was: 6% at 50 cm, 1% at 2 m, and 0.5% at 3 m in the non-laminar air flow; and 3%, 0.5%, and 0.2% in the laminar air flow, respectively. CONCLUSION: Accurate mapping of droplet spread in clinical environments is possible using fluorescein staining and image analysis. The laminar air flow affected the smaller droplets but had limited effect on larger droplets in our 'aerosol-generating procedure' cough model. Our results indicate that the laminar air flow theatre requires similar post-surgery cleaning to the non-laminar, and staff should consider full personal protective equipment for medium- and high-risk patients.


Subject(s)
Aerosols , Air Microbiology , COVID-19/prevention & control , COVID-19/transmission , Disease Transmission, Infectious/statistics & numerical data , Environment, Controlled , Operating Rooms/statistics & numerical data , Humans , SARS-CoV-2
6.
Anaesthesia ; 76(2): 174-181, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33022093

ABSTRACT

The potential aerosolised transmission of severe acute respiratory syndrome coronavirus-2 is of global concern. Airborne precaution personal protective equipment and preventative measures are universally mandated for medical procedures deemed to be aerosol generating. The implementation of these measures is having a huge impact on healthcare provision. There is currently a lack of quantitative evidence on the number and size of airborne particles produced during aerosol-generating procedures to inform risk assessments. To address this evidence gap, we conducted real-time, high-resolution environmental monitoring in ultraclean ventilation operating theatres during tracheal intubation and extubation sequences. Continuous sampling with an optical particle sizer allowed characterisation of aerosol generation within the zone between the patient and anaesthetist. Aerosol monitoring showed a very low background particle count (0.4 particles.l-1 ) allowing resolution of transient increases in airborne particles associated with airway management. As a positive reference control, we quantitated the aerosol produced in the same setting by a volitional cough (average concentration, 732 (418) particles.l-1 , n = 38). Tracheal intubation including facemask ventilation produced very low quantities of aerosolised particles (average concentration, 1.4 (1.4) particles.l-1 , n = 14, p < 0.0001 vs. cough). Tracheal extubation, particularly when the patient coughed, produced a detectable aerosol (21 (18) l-1 , n = 10) which was 15-fold greater than intubation (p = 0.0004) but 35-fold less than a volitional cough (p < 0.0001). The study does not support the designation of elective tracheal intubation as an aerosol-generating procedure. Extubation generates more detectable aerosol than intubation but falls below the current criterion for designation as a high-risk aerosol-generating procedure. These novel findings from real-time aerosol detection in a routine healthcare setting provide a quantitative methodology for risk assessment that can be extended to other airway management techniques and clinical settings. They also indicate the need for reappraisal of what constitutes an aerosol-generating procedure and the associated precautions for routine anaesthetic airway management.


Subject(s)
Aerosols , Airway Extubation , COVID-19/transmission , Intubation, Intratracheal , Airway Management , Anesthesia , Anesthetists , Cough , Environmental Monitoring , Humans , Operating Rooms , Particle Size , Patients , Personal Protective Equipment , Prospective Studies , Respiration, Artificial , SARS-CoV-2 , Ventilation