1.
BME Front ; 20222022.
Article in English | MEDLINE | ID: mdl-35928598

ABSTRACT

Large aperture ultrasonic arrays can be implemented by tiling together multiple pretested modules of high-density acoustic arrays with closely integrated multiplexing and buffering electronics to form a larger aperture with high yield. These modular arrays can be used to implement large 1.75D array apertures capable of focusing in elevation for uniform slice thickness along the axial direction which can improve image contrast. An important goal for large array tiling is obtaining high yield and sensitivity while reducing extraneous image artifacts. We have been developing tileable acoustic-electric modules for the implementation of large array apertures utilizing Application Specific Integrated Circuits (ASICs) implemented using 0.35 µ m high voltage (50 V) CMOS. Multiple generations of ASICs have been designed and tested. The ASICs were integrated with high-density transducer arrays for acoustic testing and imaging. The modules were further interfaced to a Verasonics Vantage imaging system and were used to image industry standard ultrasound phantoms. The first-generation modules comprise ASICs with both multiplexing and buffering electronics on-chip and have demonstrated a switching artifact which was visible in the images. A second-generation ASIC design incorporates low switching injection circuits which effectively mitigate the artifacts observed with the first-generation devices. Here, we present the architecture of the two ASIC designs and module types as well imaging results that demonstrate reduction in switching artifacts for the second-generation devices.

3.
Article in English | MEDLINE | ID: mdl-31567082

ABSTRACT

Tiled modular 2-D ultrasound arrays have the potential for realizing large apertures for novel diagnostic applications. This work presents an architecture for fabrication of tileable 2-D array modules implemented using 1-3 composites of high-bandwidth (BW) PIN-PMN-PT single-crystal piezoelectric material closely coupled with high-voltage CMOS application-specific integrated circuit (ASIC) electronics for buffering and multiplexing functions. The module, which is designed to be operated as a λ -pitch 1.75-D array, benefits from an improved electromechanical coupling coefficient and increased Curie temperature and is assembled directly on top of the ASIC silicon substrate using an interposer backing. The interposer consists of a novel 3-D printed acrylic frame that is filled with conducting and acoustically absorbing silver epoxy material. The ASIC comprises a high-voltage switching matrix with locally integrated buffering and is interfaced to a Verasonics Vantage 128, using a local field programmable gate array (FPGA) controller. Multiple prototype 5 ×6 element array modules have been fabricated by this process. The combined acoustic array and ASIC module was configured electronically by programming the switches to operate as a 1-D array with elements grouped in elevation for imaging and pulse-echo testing. The resulting array configuration had an average center frequency of 4.55 MHz, azimuthal element pitch of [Formula: see text], and exhibited average -20-dB pulsewidth of 592 ns and average -6-dB fractional BW of 77%.

4.
Article in English | MEDLINE | ID: mdl-30908207

ABSTRACT

This paper describes the development of a miniaturized 15-MHz side-looking phased-array transducer catheter. The array features a 2-2 linear composite with 64 piezoelectric elements mechanically diced into a piece of PMN-30%PT single crystal and separated by non-conductive epoxy kerfs at a 50-µm pitch, yielding a total active aperture of 3.2 mm in the azimuth direction and 1.8 mm in the elevation direction, with an elevation natural focal depth of 8.1 mm. The array includes non-conductive epoxy backing and two front matching layers. A custom flexible circuit connects the array piezoelectric elements to a bundle of 64 individual 48-AWG micro-coaxial cables enclosed within a 1.5-m long 10F catheter. Performance characterization was evaluated via finite element analysis simulations and afterwards compared against obtained measurement results, which showed an average center frequency of 17.7 MHz, an average bandwidth of 52.2% at -6 dB, and crosstalk less than -30 dB. Imaging of a tungsten fine-wire phantom resulted in axial and lateral spatial resolutions of approximately 90 µm and 420 ìm, respectively. The imaging capability was further evaluated with colorectal tissue-mimicking phantoms, demonstrating the potential suitability of the proposed phased-array transducer for the intraoperative assessment of surgical margins during minimally invasive colorectal surgery procedures.

5.
Article in English | MEDLINE | ID: mdl-24859667

ABSTRACT

This paper reports the design, fabrication, and characterization of a miniature high-frequency kerfless phased array prepared from a PMN-PT single crystal for forward-looking intravascular or endoscopic imaging applications. After lapping down to around 40 µm, the PMN-PT material was utilized to fabricate 32-element kerfless phased arrays using micromachining techniques. The aperture size of the active area was only 1.0 × 1.0 mm. The measured results showed that the array had a center frequency of 40 MHz, a bandwidth of 34% at -6 dB with a polymer matching layer, and an insertion loss of 20 dB at the center frequency. Phantom images were acquired and compared with simulated images. The results suggest that the feasibility of developing a phased array mounted at the tip of a forward-looking intravascular catheter or endoscope. The fabricated array exhibits much higher sensitivity than PZT ceramic-based arrays and demonstrates that PMN-PT is well suited for this application.


Subject(s)
Endosonography/instrumentation , Lead/radiation effects , Micro-Electrical-Mechanical Systems/instrumentation , Niobium/radiation effects , Oxides/radiation effects , Titanium/radiation effects , Transducers , Ultrasonography, Interventional/instrumentation , Ultrasonography/instrumentation , Crystallization , Equipment Design , Equipment Failure Analysis , Microarray Analysis/instrumentation , Phantoms, Imaging , Reproducibility of Results , Sensitivity and Specificity
6.
Article in English | MEDLINE | ID: mdl-23365943

ABSTRACT

A real-time integrated electrochemically-based dose tracking system for closed-loop drug delivery is presented. Thin film Pt sensors were integrated in an electrolytic MEMS drug delivery pump to allow dose tracking via electrochemical impedance measurement. Measurement electrode placement and composition were investigated. A bolus resolution of 230 nL was demonstrated. The sensor was calibrated for use with water (low conductivity) and 1 × PBS (high conductivity), the selected model aqueous drugs. The impedance response is dependent on delivered volume and not affected by actuation parameters. A graphical user interface was created for real-time impedance based dose tracking and leakage/blockage detection in the system. Drift in the impedance response of an idle system after perturbation (actuation) were investigated and mitigated through the use of Pt wire electrodes as opposed to thin film electrodes.


Subject(s)
Drug Delivery Systems/instrumentation , Computer Systems , Drug Delivery Systems/statistics & numerical data , Electric Impedance , Electrochemical Techniques , Electrodes , Electrolysis/instrumentation , Equipment Design , Humans