Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 31(4): 6862-6876, 2023 Feb 13.
Article in English | MEDLINE | ID: mdl-36823933

ABSTRACT

Morphology and functional metrics of retinal layers are important biomarkers for many human ophthalmic diseases. Automatic and accurate segmentation of retinal layers is crucial for disease diagnosis and research. To improve the performance of retinal layer segmentation, a multiscale joint segmentation framework for retinal optical coherence tomography (OCT) images based on bidirectional wave algorithm and improved graph theory is proposed. In this framework, the bidirectional wave algorithm was used to segment edge information in multiscale images, and the improved graph theory was used to modify edge information globally, to realize automatic and accurate segmentation of eight retinal layer boundaries. This framework was tested on two public datasets and two OCT imaging systems. The test results show that, compared with other state-of-the-art methods, this framework does not need data pre-training and parameter pre-adjustment on different datasets, and can achieve sub-pixel retinal layer segmentation on a low-configuration computer.


Subject(s)
Algorithms , Tomography, Optical Coherence , Humans , Tomography, Optical Coherence/methods , Retina/anatomy & histology
2.
Technol Health Care ; 30(S1): 501-512, 2022.
Article in English | MEDLINE | ID: mdl-35124624

ABSTRACT

BACKGROUND: The beamforming algorithm is key to the image quality of the medical ultrasound system. The generalized sidelobe canceler (GSC) beamforming can improve the image quality in lateral resolution, but the contrast is not improved correspondingly. OBJECTIVE: In our research, we try to optimize the generalized sidelobe canceler to obtain images that achieve an improvement in both lateral resolution and contrast. METHODS: We put forward a new beamforming algorithm which combines the generalized sidelobe canceler and Eigenspace-Wiener postfilter. According to eigenspace decomposition of the covariance matrix of the received data, the components of the Wiener postfilter can be calculated from the signal matrix and the noise matrix. Then, the adaptive weight vector of GSC is further constrained by the Eigenspace-Wiener postfilter, which make the output energy of the receiving array closer to the desired signal than the conventional GSC output. RESULTS: We compare the new beamforming algorithm with delay-and-sum (DS) beamforming, synthetic aperture (SA) beamforming, and GSC beamforming using the simulated and experimental data sets. The quantitative results show that our method reduces the FWHM by 85.5%, 80.5%, and 38.9% while improving the CR by 123.6%, 47.7%, 84.4% on basis of DS, SA, and GSC beamforming, respectively. CONCLUSIONS: The new beamforming algorithm can obviously improve the imaging quality of medical ultrasound imaging systems in both lateral resolution and contrast.


Subject(s)
Algorithms , Image Processing, Computer-Assisted , Humans , Image Processing, Computer-Assisted/methods , Phantoms, Imaging , Radiography , Ultrasonography/methods
3.
Biomed Opt Express ; 12(4): 1792-1803, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-33996198

ABSTRACT

Optical coherence tomography (OCT) is an important medical diagnosis technology, but OCT images are inevitably interfered by speckle noise and other factors, which greatly reduce the quality of the OCT image. In order to improve the quality of the OCT image quickly, a fast OCT image enhancement method is proposed based on the fusion equation. The proposed method consists of three parts: edge detection, noise suppression, and image fusion. In this paper, the improved wave algorithm is used to detect the image edge and its fine features, and the averaging uncorrelated images method is used to suppress speckle noise and improve image contrast. In order to sharpen image edges while suppressing the speckle noise, a sigmoid-energy conservation equation (SE equation) is designed to fuse the edge detection image and the noise suppression image. The proposed method was tested on two publicly available datasets. Results show that the proposed method can effectively improve image contrast and sharpen image edges while suppressing the speckle noise. Compared with other state-of-the-art methods, the proposed method has better image enhancement effect and speed. Under the same or better enhancement effect, the processing speed of the proposed method is 2 ∼ 34 times faster than other methods.

4.
Sensors (Basel) ; 20(4)2020 Feb 19.
Article in English | MEDLINE | ID: mdl-32092995

ABSTRACT

Aiming at the problems of feature point calibration method of 3D light detection and ranging (LiDAR) and camera calibration that are calibration boards in various forms, incomplete information extraction methods and large calibration errors, a novel calibration board with local gradient depth information and main plane square corner information (BWDC) was designed. In addition, the "three-step fitting interpolation method" was proposed to select feature points and obtain the corresponding coordinates of feature points in the LiDAR coordinate system and camera pixel coordinate system based on BWDC. Finally, calibration experiments were carried out, and the calibration results were verified by methods such as incremental verification and reprojection error comparison. The calibration results show that using BWDC and the "three-step fitting interpolation method" can solve quite accurate coordinate transformation matrix and intrinsic and external parameters of sensors, which dynamically change within 0.2% in the repeatable experiments. The difference between the experimental value and the actual value in the incremental verification experiment is about 0.5%. The average reprojection error is 1.8312 pixels, and the value changes at different distances do not exceed 0.1 pixels, which also show that the calibration method is accurate and stable.

5.
Sensors (Basel) ; 19(23)2019 Nov 28.
Article in English | MEDLINE | ID: mdl-31795112

ABSTRACT

Simultaneous measurement of temperature and strain was demonstrated using a polarization-maintaining few-mode Bragg grating (PM-FMF-FBG) based on the wavelength and phase modulation of the even L P 11 mode. The wavelength shift sensitivity and the interrogated phase sensitivity of the temperature and strain were measured to be 10 pm·°C-1 and 0.73 pm·µÎµ-1 and -3.2 × 10-2 rad·°C-1 and 4 × 10-4 rad·µÎµ-1, respectively, with a discrimination efficiency of 98%. The polarization interference led to selective polarization excitation of the reflection spectra, and the calculated phase sensitivity agreed with the experimental results.

6.
J Xray Sci Technol ; 27(6): 995-1006, 2019.
Article in English | MEDLINE | ID: mdl-31594279

ABSTRACT

BACKGROUND: Optical coherence tomography (OCT) is a non-invasive diagnosing tool used in clinics. Due to its high resolution (<10um), it is appropriate for the early detection of tiny infections. It has been widely used in diagnosis and treatment of diseases, evaluation of therapeutic efficacy, and monitoring of various physiological and pathological processes. OBJECTIVE: To systemically review literature to summarize the clinic application of OCT in recent years. METHODS: For clinic applications that OCT has been applied, we selected studies that describe the most relevant works. The discussion included: 1) which tissue could be used in the OCT detection, 2) which character of different tissue could be used as diagnosing criteria, 3) which diseases and pathological process have been diagnosed or monitored using OCT imaging, and 4) the recent development of clinic OCT diagnosing. RESULTS: The literature showed that the OCT had been listed as a routine test choice for ophthalmic diseases, while the first commercial product for cardiovascular OCT detection had gotten clearance. Meanwhile, as the development of commercial benchtop OCT equipment and tiny fiber probe, the commercial application of OCT in dermatology, dentistry, gastroenterology and urology also had great potential in the near future. CONCLUSIONS: The analysis and discussions showed that OCT, as an optical diagnosing method, has been used successfully in many clinical fields, and has the potential to be a standard inspection method in several clinic fields, such as dermatology, dentistry and cardiovascular.


Subject(s)
Tomography, Optical Coherence , Cardiovascular Diseases/diagnostic imaging , Eye Diseases/diagnostic imaging , Gastrointestinal Diseases/diagnostic imaging , Humans , Image Processing, Computer-Assisted , Skin Diseases/diagnostic imaging , Tomography, Optical Coherence/instrumentation , Tomography, Optical Coherence/methods , Tooth Diseases/diagnostic imaging , Urologic Diseases/diagnostic imaging
7.
Opt Express ; 26(20): 26646-26662, 2018 Oct 01.
Article in English | MEDLINE | ID: mdl-30469747

ABSTRACT

Illuminance nonuniformity caused by natural vignetting can seriously affect the display quality of large-field-of-view (FOV) waveguide displays. In this paper, an optimization method based on the differential evolution algorithm is proposed for in-coupling grating design to improve coupling efficiency and compensate for natural vignetting. The in-coupling grating parameters are optimized to achieve efficiency distributions in which efficiency increases continuously with incidence angle, realizing uniform illuminance over a large FOV of 45°. The angular uniformity reaches 0.89. Additionally, average diffraction efficiency reaches 89.13% for transverse-electric polarization at 532 nm and 76% in the wavelength region between 450 and 700 nm.

SELECTION OF CITATIONS
SEARCH DETAIL
...