Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Anal Bioanal Chem ; 410(21): 5113-5122, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29943265

ABSTRACT

Material morphology-dependent cataluminescence (CTL) sensing characteristic and application are presented in this work. Hierarchical hollow microspheres CeO2 were synthesized via the hydrothermal reaction of glucose and N, N-dimethyl-formamide (Glu-DMF). SEM, XRD, TEM, HRTEM and BET were used to characterize the prepared CeO2 materials. Compared with CeO2 cubics (CeO2 Cubs), CeO2 hierarchical hollow microspheres (CeO2 HMs) show an enhanced CTL response to carbon disulfide. The response and recovery times of CeO2 HMs-based CTL sensor towards carbon disulfide are about 8 s and 20 s, respectively. CeO2 HMs exhibits a linear CTL response to carbon disulfide in the concentration range of 0.50~10 µg•mL-1 with an excellent sensitivity and selectivity. These results suggest that CeO2 HMs will be a highly promising CTL sensing material for the detection and monitoring carbon disulfide. Graphical abstract CeO2 hierarchical hollow microspheres (CeO2 HMs) were synthesized via the hydrothermal reaction of glucose and N, N-dimethyl-formamide (Glu-DMF). Meanwhile, the prepared CeO2 HMs shows commendable CTL response towards carbon disulfide. Due to the excellent analytical performance of designed CeO2 HMs-based sensor for carbon disulfide, it has potential application value in various locations.

2.
Talanta ; 82(2): 733-8, 2010 Jul 15.
Article in English | MEDLINE | ID: mdl-20602962

ABSTRACT

This work proposed a gas sensor for the determination of tert-butyl mercaptan, one of the highly toxic volatile sulfur compounds, which was based on cataluminescence emission during its catalytic oxidation on the surface of nanosized V(2)O(5). The cataluminescence characteristics and the optimum conditions, including the morphology of sensing material, the wavelength of cataluminescence emission, the oxygen flow rate and working temperature were investigated in detail. Under the optimized conditions, the calibration curve of the relative cataluminescence intensity versus the concentration of tert-butyl mercaptan vapor was made, with the linear range of 5.6-196 microg mL(-1) and the detection limit of 0.5 microg mL(-1) (S/N=3). The relative standard deviation (R.S.D.) (n=5) of relative cataluminescence intensity for 84 microg mL(-1) tert-butyl mercaptan was 3.6%. There is no or weak response to some common substances, such as formic acid, alcohol (methanol, ethanol, propanol, isopropanol, n-butanol, isoamyl alcohol), o-dichlorobenzene, acetonitrile, ethyl acetate, aldehyde (formaldehyde, acetaldehyde and propanal), 1,2-dichloroethane and ammonia. Furthermore, the proposed sensor was successfully used for determining tert-butyl mercaptan in four artificial samples, with a good recovery. The results demonstrated that the proposed gas sensor had a promising capability for the tert-butyl mercaptan in routine monitoring.


Subject(s)
Nanoparticles/chemistry , Sulfhydryl Compounds/analysis , Sulfhydryl Compounds/classification , Vanadium Compounds/chemistry , Catalysis , Gases , Luminescent Measurements/methods , Microscopy, Electron, Scanning
SELECTION OF CITATIONS
SEARCH DETAIL
...