Anal Methods ; 12(48): 5823-5832, 2020 12 23.
Article in English | MEDLINE | ID: mdl-33241801

ABSTRACT

A procedure for electroanalytical determination of the fungicide TBZ extracted and preconcentrated from tomatoes by the cloud-point extraction (CPE) technique was developed and validated in this work. The analytical technique used for this determination was HPLC coupled to an electrochemical detector (HPLC/EC), with a BDD electrode. The main variables of the CPE process were evaluated using a 24 full factorial design. The optimal condition of CPE was achieved by using Tergitol (19% v/v), NaCl (0.83 g), ultrasonic stirring time of 15 min and a temperature of 36 °C. Under these conditions, the preconcentration factor obtained was 5.7. The limits of detection (LOD) and quantification (LOQ) were 2.7 × 10-8 mol L-1 (or 5.4 µg L-1) and 5.5 × 10-8 mol L-1 (or 11 µg L-1), respectively. The average recovery values varied from 80.7% to 115.1% and the precision (average of 3 days) was less than 15%, indicating the good accuracy and precision of the method developed here. Upon applying the method to examine commercial tomatoes, TBZ was detected in one of the three analyzed samples.


Subject(s)
Pesticides , Solanum lycopersicum , Chromatography, High Pressure Liquid , Limit of Detection , Thiabendazole