Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Knee Surg Sports Traumatol Arthrosc ; 28(1): 320-325, 2020 Jan.
Article in English | MEDLINE | ID: mdl-29627930

ABSTRACT

PURPOSE: To assess whether early rehabilitation could be safe after flexor digitorum longus (FDL) tendon transfer, the current biomechanical study aimed to measure tendon displacement under cyclic loading and load to failure, comparing a traditional tendon-to-tendon (TT) repair with interference screw fixation (ISF). METHODS: 24 fresh-frozen cadaveric below knee specimens underwent FDL tendon transfer. In 12 specimens a TT repair was performed via a navicular bone tunnel. In a further 12 specimens ISF was performed. Using a materials testing machine, the FDL tendon was cycled 1000 times to 150 N and tendon displacement at the insertion site measured. A final load to failure test was then performed. Statistical analysis was performed using two-way ANOVA and an independent t test, with a significance level of p < 0.05. RESULT: No significant difference in tendon displacement occurred after cyclic loading, with mean tendon displacements of 1.9 ± 1.2 mm (mean ± SD) in the TT group and 1.8 ± 1.5 mm in the ISF group (n.s.). Two early failures occurred in the ISF group, none in the TT group. Mean load to failure was significantly greater following TT repair (459 ± 96 N), compared with ISF (327 ± 76 N), p = 0.002. CONCLUSION: Minimal tendon displacement of less than 2 mm occurred during cyclic testing in both groups. The two premature failures and significantly reduced load to failure observed in the ISF group, however, indicate that the traditional TT technique is more robust. Regarding clinical relevance, this study suggests that early active range of motion and protected weight bearing may be safe following FDL tendon transfer for stage 2 tibialis posterior tendon dysfunction.


Subject(s)
Tarsal Bones/surgery , Tendon Transfer/methods , Adult , Biomechanical Phenomena , Bone Screws , Foot/surgery , Humans , Male , Middle Aged , Tendons/surgery , Weight-Bearing
2.
Foot Ankle Int ; 39(7): 858-864, 2018 07.
Article in English | MEDLINE | ID: mdl-29582684

ABSTRACT

BACKGROUND: Tibialis posterior (TP) tendon transfer is an effective treatment for foot drop. Currently, standard practice is to immobilize the ankle in a cast for 6 weeks nonweightbearing, risking postoperative stiffness. To assess whether early active dorsiflexion and protected weightbearing could be safe, the current study assessed tendon displacement under cyclic loading and load to failure, comparing the Pulvertaft weave (PW) to interference screw fixation (ISF) in a cadaveric foot model. METHODS: Twenty-four cadaveric ankles had TP tendon transfer performed, 12 with the PW technique and 12 with ISF to the cuboid. The TP tendon was cycled 1000 times at 50 to 150 N and then loaded to failure in a materials testing machine. Tendon displacement at the insertion site was recorded every 100 cycles. An independent t test and 2-way analysis of variance were performed to compare techniques, with a significance level of P < .05. RESULTS: Mean tendon displacement was similar in the PW group (2.9 ± 2.5 mm [mean ± SD]) compared with the ISF group (2.4 ± 1.1 mm), P = .35. One specimen in the ISF group failed early by tendon pullout. None of the PW group failed early, although displacement of 8.9 mm was observed in 1 specimen. Mean load to failure was 419.1 ± 82.6 N in the PW group in comparison to 499.4 ± 109.6 N in the ISF group, P = .06. CONCLUSION: For TP tendon transfer, ISF and PW techniques were comparable, with no differences in tendon displacement after cyclical loading or load to failure. Greater variability was observed in the PW group, suggesting it may be a less reliable technique. CLINICAL RELEVANCE: The results indicate that early active dorsiflexion and protected weightbearing may be safe for clinical evaluation, with potential benefits for the patient compared with cast immobilization.


Subject(s)
Bone Screws , Peroneal Neuropathies/surgery , Tendon Transfer/methods , Biomechanical Phenomena , Cadaver , Humans , Muscle, Skeletal/surgery , Supination , Tarsal Bones/surgery , Tendon Transfer/instrumentation , Tendons/transplantation , Tibia
SELECTION OF CITATIONS
SEARCH DETAIL
...