Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Cardiovasc Revasc Med ; 58: 79-87, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37474355

ABSTRACT

BACKGROUND: To assess the reproducibility of coronary tissue characterization by an Artificial Intelligence Optical Coherence Tomography software (OctPlus, Shanghai Pulse Medical Imaging Technology Inc.). METHODS: 74 patients presenting with multivessel ST-segment elevation myocardial infarction (STEMI) underwent optical coherence tomography (OCT) of the infarct-related artery at the end of primary percutaneous coronary intervention (PPCI) and during staged PCI (SPCI) within 7 days thereafter in the MATRIX (Minimizing Adverse Hemorrhagic Events by Transradial Access Site and angioX) Treatment-Duration study (ClinicalTrials.gov, NCT01433627). OCT films were run through the OctPlus software. The same region of interest between either side of the stent and the first branch was identified on OCT films for each patient at PPCI and SPCI, thus generating 94 pairs of segments. 42 pairs of segments were re-analyzed for intra-software difference. Five plaque characteristics including cholesterol crystal, fibrous tissue, calcium, lipid, and macrophage content were analyzed for various parameters (span angle, thickness, and area). RESULTS: There was no statistically significant inter-catheter (between PPCI and SPCI) or intra-software difference in the mean values of all the parameters. Inter-catheter correlation for area was best seen for calcification [intraclass correlation coefficient (ICC) 0.86], followed by fibrous tissue (ICC 0.87), lipid (ICC 0.62), and macrophage (ICC 0.43). Some of the inter-catheter relative differences for area measurements were large: calcification 9.75 %; cholesterol crystal 74.10 %; fibrous tissue 5.90 %; lipid 4.66 %; and macrophage 1.23 %. By the intra-software measurements, there was an excellent correlation (ICC > 0.9) for all tissue types. The relative differences for area measurements were: calcification 0.64 %; cholesterol crystal 5.34 %; fibrous tissue 0.19 %; lipid 1.07 %; and macrophage 0.60 %. Features of vulnerable plaque, minimum fibrous cap thickness and lipid area showed acceptable reproducibility. CONCLUSION: The present study demonstrates an overall good reproducibility of tissue characterization by the Artificial Intelligence Optical Coherence Tomography software. In future longitudinal studies, investigators may use discretion in selecting the imaging endpoints and sample size, accounting for the observed relative differences in this study.


Subject(s)
Coronary Artery Disease , Percutaneous Coronary Intervention , Plaque, Atherosclerotic , Humans , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/methods , Artificial Intelligence , Tomography, Optical Coherence , Reproducibility of Results , China , Longitudinal Studies , Software , Lipids , Cholesterol , Coronary Vessels/diagnostic imaging
2.
Cardiovasc Revasc Med ; 61: 26-34, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38042738

ABSTRACT

BACKGROUND: Recent clinical data indicate a different performance of biodegradable polymer (BP)-drug eluting stent (DES) compared to durable polymer (DP)-DES. Whether this can be explained by a beneficial impact of BP-DES stent design on the local hemodynamic forces distribution remains unclear. OBJECTIVES: To compare endothelial shear stress (ESS) distribution after implantation of ultrathin (us) BP-DES and DP-DES and examine the association between ESS and neointimal thickness (NIT) distribution in the two devices at 9 months follow up. METHODS AND RESULTS: We retrospectively identified patients from the BIOFLOW II trial that had undergone OCT imaging. OCT data were utilized to reconstruct the surface of the stented segment at baseline and 9 months follow-up, simulate blood flow, and measure ESS and NIT in the stented segment. The patients were divided into 3 groups depending on whether DP-DES (N = 8, n = 56,160 sectors), BP-DES with a stent diameter of >3 mm (strut thickness of 80 µm, N = 6, n = 36,504 sectors), or BP-DES with a stent diameter of ≤3 mm (strut thickness of 60 µm, N = 8, n = 50,040 sectors) were used for treatment. The ESS, and NIT distribution and the association of these two variables were estimated and compared among the 3 groups. RESULTS: In the DP-DES group mean NIT was 0.18 ± 0.17 mm and ESS 1.68 ± 1.66 Pa; for the BP-DES ≤3 mm group the NIT was 0.17 ± 0.11 mm and ESS 1.49 ± 1.24 Pa and for the BP-DES >3 mm group 0.20 ± 0.23 mm and 1.42 ± 1.24 Pa respectively (p < 0.001 for both NIT and ESS comparisons across groups). A negative correlation between NIT and baseline ESS was found, the correlation coefficient for all the stented segments was -0.33, p < 0.001. CONCLUSION: In this OCT sub-study of the BIOFLOW II trial, the NIT was statistically different between groups of patients treated with BP-DES and DP-DES. In addition, regions of low ESS were associated with increased NIT in all studied devices.


Subject(s)
Coronary Artery Disease , Drug-Eluting Stents , Percutaneous Coronary Intervention , Humans , Tomography, Optical Coherence , Absorbable Implants , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/therapy , Coronary Artery Disease/etiology , Polymers , Retrospective Studies , Treatment Outcome , Prosthesis Design , Stents , Percutaneous Coronary Intervention/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...