Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Publication year range
1.
J Radiol Case Rep ; 3(6): 16-20, 2009.
Article in English | MEDLINE | ID: mdl-22470665

ABSTRACT

A hydrocele is a collection of fluid in the space surrounding the testicle between the layers of the tunica vaginalis. Occasionally the scrotal hydrocele may extend through the inguinal canal, deep inguinal ring, and into the abdomen as an abdominoscrotal hydrocele. Traditionally, abdominoscrotal hydrocele have been evaluated and diagnosed with US. However if a relationship between the abdominal mass and the hydrocele is not clearly defined by sonography, the traditional modality for imaging the abdomen and the scrotum such as CT or MRI, should be considered because it can be difficult to clearly delineate the anatomy and the full extent of the abnormality. We present a rare case of a giant hemorrhagic abdominoscrotal hydrocele in a 24 year old man that required an elective operative laparotomy for complete excision of the abdominolscrotal mass.

2.
Eur J Radiol ; 64(1): 15-26, 2007 Oct.
Article in English | MEDLINE | ID: mdl-17412544

ABSTRACT

PURPOSE: To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. METHODS AND MATERIALS: Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference. RESULTS: In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%. CONCLUSIONS: 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect.


Subject(s)
Angiography, Digital Subtraction/methods , Intracranial Aneurysm/diagnostic imaging , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Middle Aged , Radiographic Image Enhancement/methods , Radiographic Image Interpretation, Computer-Assisted/instrumentation , Reproducibility of Results , Sensitivity and Specificity , Tomography, X-Ray Computed/instrumentation
3.
Radiol Med ; 108(5-6): 494-502, 2004.
Article in English, Italian | MEDLINE | ID: mdl-15722995

ABSTRACT

PURPOSE: Virtual stenting (VS) is a new tool in the 3D processing work station of rotational angiography (RA) systems. This tool enables the 3D visualization of a stent or stent-graft in the site of a stenotic, obstructive or aneurysmatic lesion to be treated. We report the preliminary results obtained with this software in the treatment of segmental stenotic, obstructive or aneurysmal lesions of the iliac artery. MATERIALS AND METHODS: Seventeen patients under-went rotational angiography and 3D reformations for one or more stenoses (19 cases), obstructive lesions (2 cases) or aneurysms (2 cases) of the common and/or external iliac artery and were treated with stents in 22/23 of cases. In all cases, the VS tool was applied to the stenotic-obstructive lesion on the identified on the 3D angiogram obtained before the stenting procedure. RESULTS: The measurements of the stents/stents-grafts (length, proximal and distal diameter) provided by the tool were compared to those of the stent deployed. In 22/23 procedures, the measurements of virtual stenting and those of the deployed stent showed a good level of concordance. The system failed to provide correct measurements in only one long and tortuous iliac aneurysm. CONCLUSIONS: The ''virtual stenting'' tool proved to be reliable and fast, and enabled a more objective selection of the stent to be deployed on a stenotic-obstructive lesion in almost all cases. In cases of aneurysms of marked tortuosity, the system tends to suggest an inappropriate stent. The possibility of manually defining the optimal stent path within the aneurysmal sac might be useful.


Subject(s)
Angiography/methods , Angioplasty, Balloon , Arterial Occlusive Diseases/diagnostic imaging , Arterial Occlusive Diseases/therapy , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/therapy , Iliac Artery , Stents , Aged , Aged, 80 and over , Constriction, Pathologic , Contrast Media , Female , Humans , Iliac Artery/diagnostic imaging , Imaging, Three-Dimensional , Male , Middle Aged , Software
SELECTION OF CITATIONS
SEARCH DETAIL
...