Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 10(1): 20953, 2020 Nov 25.
Article in English | MEDLINE | ID: mdl-33239661

ABSTRACT

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

2.
Sci Rep ; 10(1): 12005, 2020 07 20.
Article in English | MEDLINE | ID: mdl-32686728

ABSTRACT

The preparation of Fe-decorated sporopollenins was achieved using pollen grains and an ionic liquid as solvent and functionalizing agent. The integrity of the organic capsules was ascertained through scanning electron microscopy studies. The presence of Fe in the capsule was investigated using FT-IR, X-ray photoemission spectroscopy and energy-dispersive X-ray spectroscopy. Electron paramagnetic resonance and magnetization measurements allowed us to demonstrate the paramagnetic behavior of our Fe-functionalized sporopollenin. A few potential applications of pollen-based systems functionalized with magnetic metal ions via ionic liquids are discussed.

3.
Biosens Bioelectron ; 91: 870-877, 2017 May 15.
Article in English | MEDLINE | ID: mdl-28161627

ABSTRACT

Point-of-care applications and patients' real-time monitoring outside a clinical setting would require disposable and durable sensors to provide better therapies and quality of life for patients. This paper describes the fabrication and performances of a temperature and a pH sensor on a biocompatible and wearable board for healthcare applications. The temperature sensor was based on a reduced graphene oxide (rGO) layer that changed its electrical resistivity with the temperature. When tested in a human serum sample between 25 and 43°C, the sensor had a sensitivity of 110±10Ω/°C and an error of 0.4±0.1°C compared with the reference value set in a thermostatic bath. The pH sensor, based on a graphene oxide (GO) sensitive layer, had a sensitivity of 40±4mV/pH in the pH range between 4 and 10. Five sensor prototypes were tested in a human serum sample over one week and the maximum deviation of the average response from reference values obtained by a glass electrode was 0.2pH units. For biological applications, the temperature and pH sensors were successfully tested for in vitro cytotoxicity with human fibroblast cells (MRC-5) over 24h.


Subject(s)
Biosensing Techniques/instrumentation , Blood Chemical Analysis/instrumentation , Graphite/chemistry , Thermometers , Cell Line , Cell Survival , Equipment Design , Fibroblasts/cytology , Humans , Hydrogen-Ion Concentration , Materials Testing , Oxidation-Reduction , Oxides/chemistry , Temperature
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2016: 1898-1901, 2016 Aug.
Article in English | MEDLINE | ID: mdl-28324956

ABSTRACT

This article describes the fabrication and characterization of a pH sensor for monitoring the wound status. The pH sensitive layer consists of a graphene oxide (GO) layer obtained by drop-casting 5 µÎ of GO dispersion onto the working electrode of a screen-printed substrate. Sensitivity was 31.8 mV/pH with an accuracy of 0.3 unit of pH. Open-circuit potentiometry was carried out to measure pH in an exudate sample. The GO pH sensor proved to be reliable as the comparison with results obtained from a standard glass electrode pH-meter showed negligible differences (<; 0.09 pH units in the worst case) for measurements performed over a period of 4 days.


Subject(s)
Electrodes , Wounds and Injuries , Graphite , Humans , Hydrogen-Ion Concentration , Oxides , Potentiometry , Wound Healing
SELECTION OF CITATIONS
SEARCH DETAIL
...