1.
Clin Chem Lab Med ; 61(2): 302-310, 2023 01 27.
Article in English | MEDLINE | ID: mdl-36395058

ABSTRACT

OBJECTIVES: During 2020, the UK's Department of Health and Social Care (DHSC) established the Moonshot programme to fund various diagnostic approaches for the detection of SARS-CoV-2, the pathogen behind the COVID-19 pandemic. Mass spectrometry was one of the technologies proposed to increase testing capacity. METHODS: Moonshot funded a multi-phase development programme, bringing together experts from academia, industry and the NHS to develop a state-of-the-art targeted protein assay utilising enrichment and liquid chromatography tandem mass spectrometry (LC-MS/MS) to capture and detect low levels of tryptic peptides derived from SARS-CoV-2 virus. The assay relies on detection of target peptides, ADETQALPQRK (ADE) and AYNVTQAFGR (AYN), derived from the nucleocapsid protein of SARS-CoV-2, measurement of which allowed the specific, sensitive, and robust detection of the virus from nasopharyngeal (NP) swabs. The diagnostic sensitivity and specificity of LC-MS/MS was compared with reverse transcription quantitative real-time polymerase chain reaction (RT-qPCR) via a prospective study. RESULTS: Analysis of NP swabs (n=361) with a median RT-qPCR quantification cycle (Cq) of 27 (range 16.7-39.1) demonstrated diagnostic sensitivity of 92.4% (87.4-95.5), specificity of 97.4% (94.0-98.9) and near total concordance with RT-qPCR (Cohen's Kappa 0.90). Excluding Cq>32 samples, sensitivity was 97.9% (94.1-99.3), specificity 97.4% (94.0-98.9) and Cohen's Kappa 0.95. CONCLUSIONS: This unique collaboration between academia, industry and the NHS enabled development, translation, and validation of a SARS-CoV-2 method in NP swabs to be achieved in 5 months. This pilot provides a model and pipeline for future accelerated development and implementation of LC-MS/MS protein/peptide assays into the routine clinical laboratory.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , Pandemics , COVID-19/diagnosis , COVID-19 Testing , Tandem Mass Spectrometry/methods , Chromatography, Liquid , Prospective Studies , Clinical Laboratory Techniques/methods , Sensitivity and Specificity , Peptides
2.
Metabolites ; 11(8)2021 Jul 22.
Article in English | MEDLINE | ID: mdl-34436414

ABSTRACT

The introduction of tandem mass spectrometry (MS/MS) to clinical laboratories and the advent of expanded newborn screening (NBS) were crucial changes to public health programs worldwide. Speed, robustness, accuracy, selectivity, and specificity of analysis are all requirements of expanded NBS and are needed to minimize false positive results risks, to possibly eliminate false negatives, and to improve the positive predictive value of NBS. In this study, we firstly evaluated the analytical performances of the RenataDX Screening System, a fully integrated flow-injection MS/MS (FIA-MS/MS) IVD system for high-throughput dried blood spot (DBS) analysis in a routine NBS laboratory. Since a choice of several commercial NBS kits is available, we sought to compare NeoBaseTM 2 (PerkinElmer®) and MassChrom® (Chromsystems) non-derivatized kits on the RenataDX platform by evaluating their analytical performances. Moreover, we verified the degree of correlation between data obtained by the two different NBS MS/MS kits by FIA-MS/MS of over 500 samples. Our data suggest that both methods correlate well with clinically insignificant differences that do not impact the NBS result. Finally, while NeoBase™ 2 offers an easier and faster sample preparation, MassChrom® provides a cleaner sample extract which empirically should improve instrument reliability.

3.
Clin Chem ; 59(11): 1630-7, 2013 Nov.
Article in English | MEDLINE | ID: mdl-23902823

ABSTRACT

BACKGROUND: LC-MS is increasingly used for therapeutic drug monitoring of tacrolimus. A recent summary from an international proficiency-testing scheme demonstrated that the mass spectrometry respondents were the largest method group. However, these methods lack standardization, which may explain the relatively poor interlaboratory agreement for such methods. This study aimed to provide one path toward the standardization of tacrolimus quantification by use of LC-MS. METHODS: A 40-member whole blood tacrolimus proficiency panel was circulated to 7 laboratories, 4 in the US and 3 in Europe, offering routine LC-MS-based quantification of tacrolimus. All laboratories used a common LC-MS platform and followed the manufacturer's instructions that accompanied an LC-MS reagent kit intended for tacrolimus quantification in whole blood samples. Four patient pools were prepared that had sufficient volume to allow comparison with a tacrolimus reference measurement procedure. RESULTS: For the 40-member panel, the standardized MassTrak LC-MS assay demonstrated excellent agreement with a validated LC-MS method used by Analytical Services International (y = 1.02x - 0.02; r = 0.99). The CVs for the pooled patient samples ranged from 2.0% to 5.4%. The mean difference from the reference measurement procedure ranged from 0.4% to 4.4%. CONCLUSIONS: Tacrolimus assay standardization, which must include all facets of the analysis, is necessary to compare patient results between laboratories and to interpret consensus guidelines. LC-MS can provide accurate and precise measurement of tacrolimus between laboratories.


Subject(s)
Chromatography, Liquid/standards , Drug Monitoring/methods , Immunosuppressive Agents/therapeutic use , Tacrolimus/therapeutic use , Tandem Mass Spectrometry/standards , Humans , Immunosuppressive Agents/standards , Laboratory Proficiency Testing , Reference Standards , Tacrolimus/standards