Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Phys Med ; 104: 129-135, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36401941

ABSTRACT

PURPOSE: Set up a lung SBRT end-to-end (e2e) test and perform a multicentre validation. MATERIAL AND METHODS: A group of medical physicists from four hospitals and the Italian Institute of Ionizing Radiation Metrology designed the present e2e test. One sub-group set up the test, while another tested its feasibility and ease of use. A satisfaction questionnaire was used to collect user feedback. Each participating centre (PC) received the ADAM breathing phantom, a microDiamond detector and radiochromic films. Following the e2e protocol, each PC performed its standard internal procedure for simulating, planning, and irradiating the phantom. Each PC uploaded its planning and treatment delivery data in a shared Google Drive. A single centre analyzed all the data. RESULTS: The e2e test was successfully performed by all PCs. Participants' comments indicated that ADAM was well suited to the purpose and the protocol well described. All PCs performed the test in static and dynamic modes. The ratio between measured and planned point dose obtained by PC1, PC2, PC3, PC4 was: 0.99, 0.96, 1.01 and 1.01 (static track) and 0.99, 1.02, 1.01 and 0.94 (dynamic track). The gamma passing rates (3 % global, 3 mm) between planned and measured dose maps were 98.5 %, 94.0 %, 99.1 % and 94.0 % (static track) and 99.5 %, 96.5 %, 86.0 % and 94.5 % (dynamic track) for PC1, PC2, PC3 and PC4, respectively. CONCLUSIONS: An e2e test for lung SBRT has been proposed and tested in a multicentre framework. The results and user feedback prove the validity of the proposed e2e test.


Subject(s)
Lung , Humans , Italy
2.
Phys Med ; 98: 122-130, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35537327

ABSTRACT

PURPOSE: To implement a semi-automatic planning technique for whole breast irradiation with two tangential IMRT fields and to test the produced dose distribution against clinical 3DCRT plans, for introducing the technique in clinical practice. METHODS: The Auto-Planning module of the Pinnacle3 (Philips) treatment planning system was used for generating a Treatment Technique on left-sided breast cancer patients treated in free breathing or in deep inspiration breath hold (DIBH) and to right-sided breast cancer patients. The technique was evaluated against 3DCRT clinical plans in terms of dosimetric plan parameters. Plan robustness toward patient displacements was assessed on a subset of patients by inducing shifts to the isocenter. RESULTS: A statistically significant improvement in target coverage and dose homogeneity was observed for autoIMRT. No statistically significant differences were observed for ipsilateral organs, except for the ipsilateral lung in left DIBH, where slightly lower Dmean and V18% are registered for autoIMRT. Slightly higher Dmean doses (although far below the constraints) to contralateral organs were observed for autoIMRT plans. AutoIMRT plans were shown to be as robust as 3DCRT plans toward isocenter shifts, with a maximum decrease in CTV coverage of -2.2% and -2.1% for autoIMRT and 3DCRT, respectively. Average planning times were 40 min for 3DCRT and 6 min for IMRT plans. CONCLUSIONS: The developed autoIMRT technique was proven to be advantageous for target coverage and homogeneity and sufficiently robust towards isocenter displacements. The use of automated planning consistently reduces the planning workload with improvements in plan quality.


Subject(s)
Breast Neoplasms , Radiotherapy, Intensity-Modulated , Unilateral Breast Neoplasms , Breast Neoplasms/radiotherapy , Breath Holding , Female , Heart/radiation effects , Humans , Organs at Risk/radiation effects , Planning Techniques , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods
3.
Phys Med ; 85: 158-164, 2021 May.
Article in English | MEDLINE | ID: mdl-34015617

ABSTRACT

PURPOSE: To determine the targeting accuracy of brain radiosurgery when planning procedures employing different MRI and MRI + CT combinations are adopted. MATERIALS AND METHOD: A new phantom, the BrainTool, has been designed and realized to test image co-registration and targeting accuracy in a realistic anatomical situation. The phantom was created with a 3D printer and materials that mimic realistic brain MRI and CT contrast using a model extracted from a synthetic MRI study of a human brain. Eight markers distributed within the BrainTool provide for assessment of the accuracy of image registrations while two cavities that host an ionization chamber are used to perform targeting accuracy measurements with an iterative cross-scan method. Two procedures employing 1.5 T MRI-only or a combination of MRI (taken with 1.5 T or 3 T scanners) and CT to carry out Gamma Knife treatments were investigated. As distortions can impact targeting accuracy, MR images were preliminary evaluated to assess image deformation extent using GammaTool phantom. RESULTS: MR images taken with both scanners showed average and maximum distortion of 0.3 mm and 1 mm respectively. The marker distances in co-registered images resulted below 0.5 mm for both MRI scans. The targeting mismatches obtained were 0.8 mm, 1.0 mm and 1.2 mm for MRI-only and MRI + CT (1,5T and 3 T), respectively. CONCLUSIONS: Procedures using a combination of MR and CT images provide targeting accuracies comparable to those of MRI-only procedures. The BrainTool proved to be a suitable tool for carrying out co-registration and targeting accuracy of Gamma Knife brain radiosurgery treatments.


Subject(s)
Radiosurgery , Brain/diagnostic imaging , Brain/surgery , Humans , Magnetic Resonance Imaging , Phantoms, Imaging
4.
Photochem Photobiol Sci ; 19(1): 34-39, 2020 Jan 22.
Article in English | MEDLINE | ID: mdl-31799583

ABSTRACT

In the field of photodynamic therapy (PDT), optimization of the in vivo therapeutic efficacy needs a comprehensive study of the photo-killing action spectrum that depends on both the photosensitizer (PS) absorption and the tissue optical properties. This is especially true in the case of gastric infections by Helicobacter pylori: PS absorption has been largely investigated in vitro, while the contribution of tissue optical properties and illumination geometry has been poorly studied, despite being parameters that reflect the specific in vivo conditions. To investigate their influence, we focussed on the case of a point-like light source positioned in the antrum. This models a therapeutic device developed by our team which consists of a LED-based ingestible pill. By a simple 3D illumination model, our approach mediates light-tissue interaction over the illuminated stomach wall surface, then calculates its average transmittance T by means of a 1D model representative of the mean gastric mucosa structure. Finally, by merging T(λ) with the photosensitizers' absorption we obtained the in vivo action spectrum. This shows two peaks at about 500 and 630 nm, indicating a noticeable influence of the tissue with respect to in vitro studies, where the action spectrum reflects PS absorption only. Our approach defines one average action spectrum for this specific therapeutic context, which reflects the need to choose one emission spectrum for the light source used. The proposed methodology could be applied to any other illumination geometry of cave organs, provided appropriate model modifications for the light source and tissue characteristics are made.


Subject(s)
Anti-Bacterial Agents/pharmacology , Gastric Mucosa/drug effects , Helicobacter Infections/drug therapy , Helicobacter pylori/drug effects , Photochemotherapy , Photosensitizing Agents/pharmacology , Gastric Mucosa/microbiology , Helicobacter Infections/microbiology , Humans , Microbial Sensitivity Tests
5.
Phys Med Biol ; 64(2): 025020, 2019 01 18.
Article in English | MEDLINE | ID: mdl-30561374

ABSTRACT

Aim of the present study was to evaluate the accuracy which can be obtained with helical TomoTherapy® (HT, Accuray) systems in the case of multiple intracranial targets treatments. Set-up accuracy was measured, for different registration options and MegaVoltage CT (MVCT) slice thickness, by applying known misalignments to an ad-hoc developed phantom. End-to-end (E2E) tests were performed to assess the delivery accuracy in phantoms containing multiple targets by using radiochromic films: measured dose distribution centroids were compared with physical and calculated target positions on axial and coronal planes. A Gamma index analysis was carried out on planned and measured planar dose maps. The bone and tissue algorithm with the fine MVCT reconstruction grid gave the best results among the automatic options. The most accurate registration modality resulted to be the manual one with a sub-voxel accuracy shifts and a capability in the detection of rotations within 0.3°. For the E2E along the coronal plane (six targets), a mean deviation between measured dose distribution centroids and physical barycenters of 0.6 mm (range 0.1 mm-1.3 mm) was observed. Along the axial plane (five targets), a mean deviation of 1.2 mm (range 0.7 mm-2.1 mm) was found for the centroids shifts. Gamma index (5%, 1 mm, local) passing rates higher than 87.5% between planned and delivered dose distributions were measured. These results demonstrate that multiple brain lesion HT treatments are feasible with an accuracy at least comparable to frameless linac-based delivery, when a set-up capable to assure angular corrections and a reliable patient immobilization is employed.


Subject(s)
Algorithms , Brain Neoplasms/diagnostic imaging , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Humans , Radiotherapy Dosage
6.
Sci Rep ; 7(1): 385, 2017 03 24.
Article in English | MEDLINE | ID: mdl-28341859

ABSTRACT

Ion irradiation is a widely employed tool to fabricate diamond micro- and nano-structures for applications in integrated photonics and quantum optics. In this context, it is essential to accurately assess the effect of ion-induced damage on the variation of the refractive index of the material, both to control the side effects in the fabrication process and possibly finely tune such variations. Several partially contradictory accounts have been provided on the effect of the ion irradiation on the refractive index of single crystal diamond. These discrepancies may be attributable to the fact that in all cases the ions are implanted in the bulk of the material, thus inducing a series of concurrent effects (volume expansion, stress, doping, etc.). Here we report the systematic characterization of the refractive index variations occurring in a 38 µm thin artificial diamond sample upon irradiation with high-energy (3 MeV and 5 MeV) protons. In this configuration the ions are fully transmitted through the sample, while inducing an almost uniform damage profile with depth. Therefore, our findings conclusively identify and accurately quantify the change in the material polarizability as a function of ion beam damage as the primary cause for the modification of its refractive index.


Subject(s)
Diamond/chemistry , Diamond/radiation effects , Optical Phenomena , Optics and Photonics , Protons , Refractometry
7.
Opt Express ; 20(17): 19382-94, 2012 Aug 13.
Article in English | MEDLINE | ID: mdl-23038581

ABSTRACT

An accurate control of the optical properties of single crystal diamond during microfabrication processes such as ion implantation plays a crucial role in the engineering of integrated photonic devices. In this work we present a systematic study of the variation of both real and imaginary parts of the refractive index of single crystal diamond, when damaged with 2 and 3 MeV protons at low-medium fluences (range: 10(15) - 10(17) cm(-2)). After implanting in 125 × 125 µm(2) areas with a scanning ion microbeam, the variation of optical pathlength of the implanted regions was measured with laser interferometric microscopy, while their optical transmission was studied using a spectrometric set-up with micrometric spatial resolution. On the basis of a model taking into account the strongly non-uniform damage profile in the bulk sample, the variation of the complex refractive index as a function of damage density was evaluated.


Subject(s)
Diamond/chemistry , Diamond/radiation effects , Models, Chemical , Refractometry/methods , Computer Simulation , Light , Protons , Scattering, Radiation
8.
Anal Chem ; 84(5): 2260-7, 2012 Mar 06.
Article in English | MEDLINE | ID: mdl-22242935

ABSTRACT

The independent verification in a forensics context of quartz grain morphological typing by scanning electron microscopy was demonstrated using particle-induced X-ray emission (PIXE) and particle-induced γ-ray emission (PIGE). Surface texture analysis by electron microscopy and high-sensitivity trace element mapping by PIXE and PIGE are independent analytical techniques for identifying the provenance of quartz in sediment samples in forensic investigations. Trace element profiling of the quartz grain matrix separately from the quartz grain inclusions served to differentiate grains of different provenance and indeed went some way toward discriminating between different quartz grain types identified in a single sample of one known forensic provenance. These results confirm the feasibility of independently verifying the provenance of critical samples from forensic cases.

9.
Phys Rev Lett ; 105(23): 233903, 2010 Dec 03.
Article in English | MEDLINE | ID: mdl-21231462

ABSTRACT

We demonstrate the feasibility of fabricating light-waveguiding microstructures in bulk single-crystal diamond by means of direct ion implantation with a scanning microbeam, resulting in the modulation of the refractive index of the ion-beam damaged crystal. Direct evidence of waveguiding through such buried microchannels is obtained with a phase-shift micro-interferometric method allowing the study of the multimodal structure of the propagating electromagnetic field. The possibility of defining optical and photonic structures by direct ion writing opens a range of new possibilities in the design of quantum-optical devices in bulk single-crystal diamond.

SELECTION OF CITATIONS
SEARCH DETAIL
...