Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 52
Filter
1.
Odontology ; 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38514512

ABSTRACT

To evaluate the impact on the quality of filling with of low-fusion and conventional gutta-percha cones. Thirty-six maxillary canines were prepared and divided into three groups: I-conventional cone with Downpack at 200 °C at 4 mm from the WL; II-low-fusion cone with Downpack at 100 °C up to 4 mm from the WL; III-low-fusion cone with Downpack at 100 °C up to 7 mm from the WL. Temperature variations were measured in thirds on the external surface of the root. The bond strength was evaluated using the push-out test. The adhesive interface was analyzed by scanning electron microscopy. The bond strength and the temperature variation data were analyzed using analysis of variance and the failure type using the chi-square test. The low-fusion cone group with 7 mm Downpack showed higher bond strength (4.2 ± 2.7) compared with conventional cones (2.8 ± 1.6) and low-fusion cones with 4 mm Downpack (2.9 ± 1.6) (p < 0.05), with occurrence of a higher number of adhesive failures to the filling material and mixed failures. Relative to temperature variation, there was less temperature change in the apical third, in the low-fusion cone with Downpack 7 mm (1.0 ± 1.0) (p < 0.05). The use of low-fusion cones allowed the continuous wave condensation technique to be performed at a lower depth of Downpack at 100 °C at 7 mm, with less heating in the apical third, without compromising the quality of filling. Using gutta-percha cones with low fusion, which permits a lower condensation temperature and reduced Downpack depth, maintains the quality of filling, in order to minimize possible damage to the periapical tissues.

2.
J Mech Behav Biomed Mater ; 151: 106400, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38262184

ABSTRACT

AIM: To mensure the physicochemical properties of three ceramic cement endodontic sealers AH Plus Bioceramic, Bio-C Sealer and Bio-C Sealer Ion+ with an epoxy resin sealer, AH Plus. MATERIAL AND METHODS: These properties were measured: hardening time (HT), dimensional change (DC), solubility (SL), flow (FL) and radiopacity (RD). The distilled water obtained from the SL test was analyzed with atomic absorption spectrometry. A sample calculation was made considering n = 5 repetitions for each experimental sealer evaluated. Statistical analysis was performed using one-way ANOVA and post hoc Tukey tests (p < 0.05). RESULTS: For the HT, AH Plus (484 ± 2.76 min) and AH Plus Bioceramic (424 ± 1.23 min) set more slowly than of Bio-C Sealer (370 ± 4.50 min) and Bio-C Sealer Ion+ (380 ± 1.42 min) (p < 0.05). AH Plus Bioceramic (12.56 ± 2.71 %) was more soluble than Bio-C Sealer (6.69 ± 1.67 %), Bio-C Sealer Ion+ (5.67 ± 2.16 %) and AH Plus (0.15 ± 0.01 %) (p < 0.05). AH Plus (0.03 ± 0.01 %) had slight expansion while the cement-based sealers had shrinkage: AH Plus Bioceramic (-1.60 ± 0.63 %) and Bio-C Sealer (-1.38 ± 0.69 %), Bio-C Sealer Ion+ (-5.19 ± 1.23 %) (p < 0.05). Bio-C Sealer Ion+ (59.80 ± 0.86 mm) and Bio-C Sealer (58.60 ± 0.98 mm) had the highest flow compared with AH Plus (56.90 ± 0.56 mm) and AH Plus Bioceramic (49.50 ± 0.63 mm) (p < 0.05). AH Plus (9.17 ± 0.06 mmAl) and AH Plus Bioceramic (8.27 ± 0.84 mmAl) showed radiopacity values when compared with those of Bio-C Sealer (4.90 ± 0.08 mmAl) and Bio-C Sealer Ion+ (4.14 ± 0.05 mmAl) (p > 0.05). CONCLUSION: Ion release is inhered to these cement-based sealers and this result in calcium ion release.


Subject(s)
Calcium , Root Canal Filling Materials , Calcium/chemistry , Root Canal Filling Materials/chemistry , Calcium Compounds/chemistry , Epoxy Resins/chemistry , Silicates/chemistry , Materials Testing
3.
Braz Oral Res ; 37: e096, 2023.
Article in English | MEDLINE | ID: mdl-38055514

ABSTRACT

The survival of endodontically treated teeth depends on the remaining tooth structure. The aim of this study was to evaluate the impact of different access cavities on root canal preparation, restorative protocol, and fracture resistance of endodontically treated teeth. Fifty-six mandibular molars were divided into control (n=8) and experimental (n=16) groups according to access cavity: Traditional, Conservative, and Truss; and redistributed (n=8) according to instrumentation protocols: Reciproc Blue and R-motion. After, teeth were scanned in micro-CT and then filled and redistributed according to composite resin restoration (n=8): Filtek One BulkFill and Filtek Z350. A new micro-CT scan was performed to analyze the restorative material. Then, samples were submitted to fracture resistance testing and the failure pattern was determined. Data were analyzed using paired T-test, ANOVA, Tukey, and chi-square tests (α=0.05). In Truss, R-Motion promoted less transportation in different thirds of root canals. Higher percentages of voids (5.05%) and filling material (11.7%) were observed in Truss. Fracture resistance values were higher for the control group, followed by Truss, Conservative, and Traditional. The predominant failure pattern was type-II. In Truss, reciprocating instruments with smaller taper showed less canal transportation. Also, Truss provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material. Thus, in Truss, reciprocating files with smaller taper showed less canal transportation, and these cavities provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material.


Subject(s)
Dental Caries , Root Canal Filling Materials , Tooth, Nonvital , Humans , Root Canal Preparation/methods , Molar , X-Ray Microtomography , Dental Pulp Cavity
4.
Clin Oral Investig ; 27(12): 7919-7933, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38032392

ABSTRACT

AIM: To evaluate the bond strength (BS) and analysis of the adhesive interface in root canals filled with bioceramic gutta percha sealers and cones. MATERIAL AND METHODS: Ninety-six maxillary canines were divided into eight groups according to the endodontic sealer (AH Plus, AH Plus Bioceramic, Bio-C Sealer or Bio-C Sealer Ion+ and gutta percha cones (conventional or bioceramic) tested. They were analyzed using the BS test, failure pattern, analysis of the adhesive interface by scanning electron microscopy and confocal laser scanning microscopy. The BS data were compared between groups using the analysis of variance test with the Turkey post-test. The chi-square test was used to assess the type of failure and the non-parametric Mann-Whitney and Kruse-Wallis tests (P < 0.05). RESULTS: Analysis of variance showed higher BS values for the groups of bioceramic gutta percha cones in Bio-C Sealer Ion+ (8.38 ± 4.27), AH Plus Bioceramic (6.19 ± 3.28), Bio-C Sealer (5.70 ± 3.18), AH Plus (4.61 ± 2.11) and for conventional gutta percha cones in AH Plus sealers (4.26 ± 2.35), Bio-C Sealer Ion + (3.63 ± 2.29), Bio-C Sealer (2.94 ± 2.32) and AH Plus Bioceramic (1.19 ± 0.89) (P < 0.05). Relative to the type of failure and adaptation of the types of filling material, a higher percentage of mixed failures was observed (gaps between 1 µm-10 µm) for the group with bioceramic gutta percha cones (P < 0.001). CONCLUSION: The bond between sealers and bioceramic gutta percha cones showed higher bond strength values and greater penetration into the dentin tubules. CLINICAL RELEVANCE: The filling the root canal system with bioceramic sealers should be associated with bioceramic gutta percha cones.


Subject(s)
Gutta-Percha , Root Canal Filling Materials , Gutta-Percha/chemistry , Root Canal Filling Materials/chemistry , Epoxy Resins/chemistry , Dental Pulp Cavity , Dental Cements , Root Canal Obturation , Materials Testing
5.
Article in English | MEDLINE | ID: mdl-37580223

ABSTRACT

OBJECTIVE: The objective of this study was to evaluate 2-dimensional (2D) and 3D morphometric parameters of C-shaped root canals on cone beam computed tomography (CBCT) and microcomputed tomography (microCT) images using nanocomputed tomography (nanoCT) as the reference standard. STUDY DESIGN: Sixty mandibular molars with C-shaped canals were individually scanned using nanoCT and microCT. Cone beam computed tomography acquisitions were then performed with 4 CBCT systems, using high and standard resolutions. The 2D parameters of roundness and major and minor diameters were obtained in the cross sections of the root canals at 1, 2, and 3 mm from the root apex. The 3D parameters of surface area, volume, and structure model index were measured considering the entire extension of the root canals. Absolute error (AE) in measurement was calculated against the nanoCT values. Data were statistically analyzed with the Shapiro-Wilk test and analysis of variance (α = 0.05). RESULTS: No significant differences in AE were discovered for the 2D parameters among microCT and the CBCT scans. The AE values for the 3D parameters of volume and surface area were significantly smaller in microCT compared to all CBCT units (P < .05). Significantly lower AE values for surface area were observed in high resolution compared to standard resolution for all CBCT units (P < .05). Structure model index did not differ significantly among microCT and all CBCT protocols. CONCLUSIONS: Cone beam computed tomography images showed accuracy for evaluating 2D parameters and over- and underestimation for 3D parameters.


Subject(s)
Cone-Beam Computed Tomography , Dental Pulp Cavity , Humans , Dental Pulp Cavity/diagnostic imaging , X-Ray Microtomography , Cone-Beam Computed Tomography/methods , Molar/diagnostic imaging , Tooth Root , Mandible/diagnostic imaging
6.
Animals (Basel) ; 13(16)2023 Aug 16.
Article in English | MEDLINE | ID: mdl-37627438

ABSTRACT

Predicting species' ecological responses to landcovers within landscapes could guide conservation practices. Current modelling efforts derived from classic species-area relationships almost always predict richness monotonically increasing as the proportion of landcovers increases. Yet evidence to explain hump-shaped richness-landcover patterns is lacking. We tested predictions related to hypothesised drivers of peaked relationships between richness and proportion of natural landcover. We estimated richness from breeding bird atlases at different spatial scales (25 to 900 km2) in New York State and Southern Ontario. We modelled richness to gradients of natural landcover, temperature, and landcover heterogeneity. We controlled models for sampling effort and regional size of the species pool. Species richness peaks as a function of the proportion of natural landcover consistently across spatial scales and geographic regions sharing similar biogeographic characteristics. Temperature plays a role, but peaked relationships are not entirely due to climate-landcover collinearities. Heterogeneity weakly explains richness variance in the models. Increased amounts of natural landcover promote species richness to a limit in landscapes with relatively little (<30%) natural cover. Higher amounts of natural cover and a certain amount of human-modified landcovers can provide habitats for species that prefer open habitats. Much of the variation in richness among landscapes must be related to variables other than natural versus human-dominated landcovers.

7.
J Endod ; 49(9): 1154-1160, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37516237

ABSTRACT

INTRODUCTION: The aim of this study was to evaluate the influence on bond strength and interface quality of different canal drying protocols in roots filled with Bio-C Sealer (BCS; Angelus, Londrina, Paraná, Brazil). METHODS: Ninety-six roots of upper canines were prepared with an R50 file (Reciproc; VDW GmbH, Munich, Germany) and irrigated with 2.5% sodium hypochlorite and 17% EDTA under ultrasonic agitation. Roots were divided according to the drying protocol as follows: dry, the White Mac tip (Ultradent, Indaiatuba, SP, Brazil) for 5 seconds followed by aspiration with a capillary tip for 5 seconds and paper points; slightly moist, the White Mac tip followed by capillary aspiration without paper points; wet, the White Mac tip followed by a single paper point. The roots were filled with BCS or AH Plus (AHP; Dentsply Maillefer, Ballaigues, Switzerland) (n = 16) and sectioned for the push-out test after 3 months. Failure modes were assessed, and the interface morphology was analyzed under scanning electron microscopy. After 6 months, the other half of the roots were evaluated. Data were analyzed by analysis of variance/Tukey test at 5%. The chi-square test was used in the failure analysis and the Kruskal-Wallis/Dwass-Steel-Critchlow-Fligner for interface analysis. RESULTS: The AHP-filled roots had the highest bond strength when the canal was dried (P < .05). No difference was found for periods (P > .05). For BCS, the highest bond strength was found in the slightly moist canals (P < .05). A predominance of adhesive failures was observed. The dried canals filled with AHP had the highest percentage of good adaptation, whereas BCS had no difference. CONCLUSIONS: The best drying protocol for AHP is using the White Mac tip followed by capillary tip aspiration and paper points until complete dryness, and for BCS, it is using the White Mac tip followed by capillary aspiration without paper points.


Subject(s)
Dental Bonding , Root Canal Filling Materials , Root Canal Filling Materials/chemistry , Epoxy Resins/chemistry , Dental Bonding/methods , Dentin , Root Canal Preparation/methods , Dental Cements
8.
Braz Oral Res ; 37: e056, 2023.
Article in English | MEDLINE | ID: mdl-37255076

ABSTRACT

To investigate the influence of the remaining volume of a new intracanal medication based on bioceramic compounds on the bond strength (BS) and formation of an adhesive interface between calcium silicate-based and epoxy resin-based root canal sealers. For this purpose, the specimens were distributed according to the intracanal medication (n = 26): Bio-C Temp (BCT) and Ultracal XS (UXS). The roots were scanned in microCT, and after 7 days, the medication was removed. Then a new scan was performed to evaluate the volume of medication remaining. Subsequently, 40 specimens were redistributed into 2 subgroups (n = 10) and filled according to the sealer used: AH Plus (AHP) and Bio-C Sealer (BCS), to assess the bond strength by using the push-out test, and the adhesive interface by confocal laser fluorescence microscopy (CLSM) and scanning electron microscopy (SEM). The t test showed a smaller remainder of BCT (1.77 ± 0.86) compared with UXS (10.47 ± 5.78), irrespective of the root third evaluated. The BS showed that teeth with BCT + BCS had higher bond strength values (3.70 ± 1.22) when compared to the other groups: BCT + AHP (2.15 ± 1.07), UXS + BCS (3.18 ± 1.09) and UXS + AHP (2.11 ± 1.02) (p<0.001). The cervical third had higher BS when compared with the middle and apical thirds (p < 0.001), and higher number of adhesive failures. The adhesive interface in SEM and CLSM images showed better adaptation for the association between BCT + BCS. Intracanal medication and silicate-based endodontic sealer appeared to interact chemically by forming a biomineralizing layer, allowing for an increase in the bond strength and forming an adhesive interface between the materials, with no or less gap formation.


Subject(s)
Dental Bonding , Root Canal Filling Materials , Root Canal Filling Materials/chemistry , Dental Pulp Cavity , Dentin , Epoxy Resins/chemistry , Dental Bonding/methods , Materials Testing
9.
Aust Endod J ; 49(1): 130-139, 2023 Apr.
Article in English | MEDLINE | ID: mdl-35649116

ABSTRACT

Shaping ability evaluation of taper ./01 instruments in large root canals, by microcomputed tomography (micro-CT) and scanning electron microscopy (SEM). Maxillary central incisors with large diameter root canals were divided into two groups (n = 10): XP-Endo Shaper (FKG-Dentaire, Switzerland) and manual instrumentation (FKG-Dentaire). Two- and three-dimensional parameters from cervical to apical root thirds were evaluated by micro-CT. Apical stop was evaluated by SEM images. Data were analysed by ANOVA and Tukey tests (α = 5%). XP-Endo Shaper allowed a regular biomechanical preparation with less dentinal wear compared with manual instrumentation, which showed excessive wear of the thin root canal walls (p < 0.05). Roundness and SMI showed similarity between both protocols (p > 0.05). XP-Endo Shaper SEM showed a regular and well-defined shape of the apical foramen suggesting the formation of the apical stop. Reduced diameter and taper instruments promoted a conservative wear and a well-defined apical stop formation in large root canals.


Subject(s)
Dental Pulp Cavity , Root Canal Preparation , Dental Pulp Cavity/diagnostic imaging , X-Ray Microtomography , Root Canal Preparation/methods , Root Canal Therapy , Tooth Apex/diagnostic imaging
10.
Braz. oral res. (Online) ; 37: e056, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1439745

ABSTRACT

Abstract To investigate the influence of the remaining volume of a new intracanal medication based on bioceramic compounds on the bond strength (BS) and formation of an adhesive interface between calcium silicate-based and epoxy resin-based root canal sealers. For this purpose, the specimens were distributed according to the intracanal medication (n = 26): Bio-C Temp (BCT) and Ultracal XS (UXS). The roots were scanned in microCT, and after 7 days, the medication was removed. Then a new scan was performed to evaluate the volume of medication remaining. Subsequently, 40 specimens were redistributed into 2 subgroups (n = 10) and filled according to the sealer used: AH Plus (AHP) and Bio-C Sealer (BCS), to assess the bond strength by using the push-out test, and the adhesive interface by confocal laser fluorescence microscopy (CLSM) and scanning electron microscopy (SEM). The t test showed a smaller remainder of BCT (1.77 ± 0.86) compared with UXS (10.47 ± 5.78), irrespective of the root third evaluated. The BS showed that teeth with BCT + BCS had higher bond strength values (3.70 ± 1.22) when compared to the other groups: BCT + AHP (2.15 ± 1.07), UXS + BCS (3.18 ± 1.09) and UXS + AHP (2.11 ± 1.02) (p<0.001). The cervical third had higher BS when compared with the middle and apical thirds (p < 0.001), and higher number of adhesive failures. The adhesive interface in SEM and CLSM images showed better adaptation for the association between BCT + BCS. Intracanal medication and silicate-based endodontic sealer appeared to interact chemically by forming a biomineralizing layer, allowing for an increase in the bond strength and forming an adhesive interface between the materials, with no or less gap formation.

11.
Braz. oral res. (Online) ; 37: e096, 2023. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1520524

ABSTRACT

Abstract The survival of endodontically treated teeth depends on the remaining tooth structure. The aim of this study was to evaluate the impact of different access cavities on root canal preparation, restorative protocol, and fracture resistance of endodontically treated teeth. Fifty-six mandibular molars were divided into control (n=8) and experimental (n=16) groups according to access cavity: Traditional, Conservative, and Truss; and redistributed (n=8) according to instrumentation protocols: Reciproc Blue and R-motion. After, teeth were scanned in micro-CT and then filled and redistributed according to composite resin restoration (n=8): Filtek One BulkFill and Filtek Z350. A new micro-CT scan was performed to analyze the restorative material. Then, samples were submitted to fracture resistance testing and the failure pattern was determined. Data were analyzed using paired T-test, ANOVA, Tukey, and chi-square tests (α=0.05). In Truss, R-Motion promoted less transportation in different thirds of root canals. Higher percentages of voids (5.05%) and filling material (11.7%) were observed in Truss. Fracture resistance values were higher for the control group, followed by Truss, Conservative, and Traditional. The predominant failure pattern was type-II. In Truss, reciprocating instruments with smaller taper showed less canal transportation. Also, Truss provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material. Thus, in Truss, reciprocating files with smaller taper showed less canal transportation, and these cavities provided higher values of fracture resistance, although it presented a higher percentage of voids and remaining filling material.

12.
Braz Oral Res ; 36: e115, 2022.
Article in English | MEDLINE | ID: mdl-36287426

ABSTRACT

This study evaluate shaping ability of heat-treated NiTi-alloy instruments associated with different final irrigation protocols in flattened root canals. Thirty human mandibular incisors with flattened root canals were divided into 5 groups (n = 10): (XP) Original Protocol XP-endo Shaper; (XP-WT) Original Protocol XP-endo Shaper with working time variation; (XP-K) XP-endo Shaper with kinematics variation; (XP-WTK) XP-endo Shaper with kinematics and working time variations; (Hyflex) Hyflex CM. For the variation in working time protocols the same sample of the XP-endo Shaper groups with and without kinematic variation were used. To evaluate final irrigation protocols, groups 1, 3 and 5 were submitted to 3 protocols: (NI) No irrigation (n = 2); (CI) conventional irrigation (n = 4), and (EndoVac) irrigation (n = 4). The samples were scanned by microcomputed tomography and prepared for scanning electron microscopy evaluation. Quantitative data were evaluated using the parametric ANOVA test, with statistical significance level set at 5%, and qualitative data obtained were compared to establish the agreement between examiners through the Kappa test. It was observed that in the analysis of XP-endo Shaper protocols, the additional working time did not cause difference in any of parameters evaluated (p > 0.05) in relation to time recommended by manufacturer. Compared to Hyflex, XP-K showed highest mean volume increase (p < 0.05) and lowest percentage of untouched walls (p < 0.05). In the qualitative evaluation, final irrigation protocol with EndoVac provided the best cleaning results when associated with XP-K and with Hyflex. Thus, supplementary techniques are effective tools to enhance cleaning and to promote higher touch of walls during root canal preparation.


Subject(s)
Dental Pulp Cavity , Hot Temperature , Humans , Dental Pulp Cavity/diagnostic imaging , X-Ray Microtomography , Root Canal Preparation , Alloys
13.
Front Cardiovasc Med ; 9: 847809, 2022.
Article in English | MEDLINE | ID: mdl-35811697

ABSTRACT

Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) employs angiotensin-converting enzyme 2 (ACE2) as its receptor for cell entrance, and studies have suggested that upon viral binding, ACE2 catalytic activity could be inhibited; therefore, impacting the regulation of the renin-angiotensin-aldosterone system (RAAS). To date, only few studies have evaluated the impact of SARS-CoV-2 infection on the blood levels of the components of the RAAS. The objective of this study was to determine the blood levels of ACE, ACE2, angiotensin-II, angiotensin (1-7), and angiotensin (1-9) at hospital admission and discharge in a group of patients presenting with severe or critical evolution of coronavirus disease 2019 (COVID-19). We showed that ACE, ACE2, angiotensin (1-7), and angiotensin (1-9) were similar in patients with critical and severe COVID-19. However, at admission, angiotensin-II levels were significantly higher in patients presenting as critical, compared to patients presenting with severe COVID-19. We conclude that blood levels of angiotensin-II are increased in hospitalized patients with COVID-19 presenting the critical outcome of the disease. We propose that early measurement of Ang-II could be a useful biomarker for identifying patients at higher risk for extremely severe progression of the disease.

14.
Adv Exp Med Biol ; 1370: 267-278, 2022.
Article in English | MEDLINE | ID: mdl-35882802

ABSTRACT

Adaptation of islet ß-cell mass and function under limiting or excess nutrient availability is critical for maintenance of glucose homeostasis. Taurine regulates islet function of obese mice in normal and low dietary protein conditions, but whether this involves remodeling of the endocrine pancreas architecture is not well understood. Here, we carried functional and morphometric evaluation of the endocrine pancreas of normal and protein-restricted mice fed a high-fat diet (HFD) and investigated the role of taurine supplementation. Weaned mice were placed in a normal (C) or a low-protein diet (R) for 6 weeks, followed by HFD for 8 weeks (CH and RH). Half of HFD groups received 5% taurine supplementation since weaning (CHT and RHT) until the end of the experiment. Isolated islets from both CH and RH groups showed increased insulin release in association with increased pancreas weight and independently of changes in islet or ß-cell area. In normal protein CHT mice, taurine supplementation prevented obesity-induced insulin hypersecretion and promoted increased islet and ß-cell areas in association with increased protein expression of the proliferation marker, PCNA. On a low-protein background, taurine effects on islet function and morphology were blunted, but it prevented obesity-induced DNA fragmentation. In summary, taurine regulates islet function and morphology to improve the adaptive response to diet-induced obesity, but these effects are dependent on adequate dietary protein levels.


Subject(s)
Islets of Langerhans , Taurine , Animals , Diet, High-Fat/adverse effects , Dietary Proteins/metabolism , Dietary Supplements , Insulin/metabolism , Islets of Langerhans/metabolism , Mice , Obesity/drug therapy , Obesity/metabolism , Taurine/metabolism , Taurine/pharmacology
15.
Int Endod J ; 55(1): 124-136, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34687053

ABSTRACT

AIM: To evaluate the shaping ability of several heat-treated nickel-titanium systems used to prepare root canals with moderate and severe curvature, in extracted mandibular molars, by micro-computed tomography, considering their variation in kinematics and design. METHODOLOGY: Curved-mesial roots of mandibular molars were randomly selected and assigned into 4 balanced experimental groups (n = 10), established by determining homogeneous 3D parameters of volume and surface area: R-Motion (RM) size 30, 0.04 taper (RM; FKG Dentaire), Reciproc Blue (RCB) size 25, 0.08 taper (RCB; VDW GmbH), HyFlex CM (HFX) size 30, 0.04 taper (HFX; Coltène Whaledent) and XP-endo Shaper size (XPS) 30, 0.01 taper (XPS; FKG Dentaire). The volume of irrigation was established at 10 ml of 2.5% NaOCl. Throughout the entire root canal preparation procedures, the samples were fixed in a vice submerged in a container with water monitored at 37°C. Dimensional cross-sectional measures of area, perimeter, roundness, major/minor diameters and 3-dimensional (volume, surface area, structure model index - SMI) parameters as well as the smallest dentine thickness along the cervical and middle root thirds were evaluated by micro-CT. Data were analysed using analysis of variance and post hoc Tukey tests (α = 5%). RESULTS: Reciproc Blue and XPS had significantly greater mean increases in cross-sectional area measurements, only in the middle third, when compared with RM and HFX (p < .05). RM, RCB and XPS had a similar increase in measurements of length and width of perimeter (p > .05), and HFX had significantly lower mean increases in perimeter values only when compared with XPS (p < .05). RCB and XPS had significantly greater mean increases in volume when compared with RM and HFX (p < .05). RM had a significantly lower difference in SMI after preparation, compared with RCB, HFX and XPS (p < .05). The smallest dentine thickness was observed after the use of RCB (p < .05), in the danger and safety zones. CONCLUSIONS: XP-endo Shaper and RM had a shaping ability similar to that of instruments with larger tapers, achieved with less dentine removal in danger and safe zones in curved-mesial canals of extracted molar teeth treated on a laboratory benchtop.


Subject(s)
Dental Pulp Cavity , Root Canal Preparation , Dental Pulp Cavity/diagnostic imaging , Equipment Design , Molar/diagnostic imaging , Molar/surgery , Nickel , Titanium , X-Ray Microtomography
16.
Braz. oral res. (Online) ; 36: e115, 2022. tab, graf
Article in English | LILACS-Express | LILACS, BBO - Dentistry | ID: biblio-1403967

ABSTRACT

Abstract This study evaluate shaping ability of heat-treated NiTi-alloy instruments associated with different final irrigation protocols in flattened root canals. Thirty human mandibular incisors with flattened root canals were divided into 5 groups (n = 10): (XP) Original Protocol XP-endo Shaper; (XP-WT) Original Protocol XP-endo Shaper with working time variation; (XP-K) XP-endo Shaper with kinematics variation; (XP-WTK) XP-endo Shaper with kinematics and working time variations; (Hyflex) Hyflex CM. For the variation in working time protocols the same sample of the XP-endo Shaper groups with and without kinematic variation were used. To evaluate final irrigation protocols, groups 1, 3 and 5 were submitted to 3 protocols: (NI) No irrigation (n = 2); (CI) conventional irrigation (n = 4), and (EndoVac) irrigation (n = 4). The samples were scanned by microcomputed tomography and prepared for scanning electron microscopy evaluation. Quantitative data were evaluated using the parametric ANOVA test, with statistical significance level set at 5%, and qualitative data obtained were compared to establish the agreement between examiners through the Kappa test. It was observed that in the analysis of XP-endo Shaper protocols, the additional working time did not cause difference in any of parameters evaluated (p > 0.05) in relation to time recommended by manufacturer. Compared to Hyflex, XP-K showed highest mean volume increase (p < 0.05) and lowest percentage of untouched walls (p < 0.05). In the qualitative evaluation, final irrigation protocol with EndoVac provided the best cleaning results when associated with XP-K and with Hyflex. Thus, supplementary techniques are effective tools to enhance cleaning and to promote higher touch of walls during root canal preparation.

17.
Front Endocrinol (Lausanne) ; 12: 701994, 2021.
Article in English | MEDLINE | ID: mdl-34552556

ABSTRACT

Obesity and insulin resistance (IR) are well-studied risk factors for systemic cardiovascular disease, but their impact on pulmonary hypertension (PH) is not well clarified. This study aims to investigate if diet-induced obesity induces PH and if peroxisome-proliferator-activated receptor (PPAR-γ) and/or endoplasmic reticulum (ER) stress are involved in this process. Mice were maintained on a high-fat diet (HFD) for 4 months, and IR and PH were confirmed. In a separate group, after 4 months of HFD, mice were treated with pioglitazone (PIO) or 4-phenylbutyric acid for the last month. The results demonstrated that HFD for at least 4 months is able to increase pulmonary artery pressure, which is maintained, and this animal model can be used to investigate the link between IR and PH, without changes in ER stress in the pulmonary artery. There was also a reduction in circulating adiponectin and in perivascular adiponectin expression in the pulmonary artery, associated with a reduction in PPAR-γ expression. Treatment with PIO improved IR and PH and reversed the lower expression of adiponectin and PPAR-γ in the pulmonary artery, highlighting this drug as potential benefit for this poorly recognized complication of obesity.


Subject(s)
Diet, High-Fat/adverse effects , Endoplasmic Reticulum Stress , Hypertension, Pulmonary/pathology , Insulin Resistance , Obesity/complications , PPAR gamma/antagonists & inhibitors , Pulmonary Artery/pathology , Animals , Hypertension, Pulmonary/etiology , Hypertension, Pulmonary/metabolism , Male , Mice , Mice, Inbred C57BL , Mice, Obese , PPAR gamma/genetics , PPAR gamma/metabolism , Pulmonary Artery/metabolism
18.
Viruses ; 13(2)2021 02 16.
Article in English | MEDLINE | ID: mdl-33669276

ABSTRACT

Background: Coronavirus disease 19 (COVID-19) can develop into a severe respiratory syndrome that results in up to 40% mortality. Acute lung inflammatory edema is a major pathological finding in autopsies explaining O2 diffusion failure and hypoxemia. Only dexamethasone has been shown to reduce mortality in severe cases, further supporting a role for inflammation in disease severity. SARS-CoV-2 enters cells employing angiotensin-converting enzyme 2 (ACE2) as a receptor, which is highly expressed in lung alveolar cells. ACE2 is one of the components of the cellular machinery that inactivates the potent inflammatory agent bradykinin, and SARS-CoV-2 infection could interfere with the catalytic activity of ACE2, leading to the accumulation of bradykinin. Methods: In this case control study, we tested two pharmacological inhibitors of the kinin-kallikrein system that are currently approved for the treatment of hereditary angioedema, icatibant, and inhibitor of C1 esterase/kallikrein, in a group of 30 patients with severe COVID-19. Results: Neither icatibant nor inhibitor of C1 esterase/kallikrein resulted in changes in time to clinical improvement. However, both compounds were safe and promoted the significant improvement of lung computed tomography scores and increased blood eosinophils, which are indicators of disease recovery. Conclusions: In this small cohort, we found evidence for safety and a beneficial role of pharmacological inhibition of the kinin-kallikrein system in two markers that indicate improved disease recovery.


Subject(s)
Bradykinin/analogs & derivatives , COVID-19 Drug Treatment , Complement C1 Inhibitor Protein/therapeutic use , Kallikrein-Kinin System/drug effects , Kallikreins/antagonists & inhibitors , Adult , Aged , Bradykinin/therapeutic use , Case-Control Studies , Drug Repositioning , Female , Humans , Lung/drug effects , Lung/pathology , Male , Middle Aged
19.
Aust Endod J ; 46(3): 452-457, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32896059

ABSTRACT

Internal root resorption is characterised by progressive loss of tooth substance initiating at the root canal wall as a result of clastic activity. This report describes a case of a perforating internal root resorption on a maxillary central incisor in a 25-year-old patient. The perforating internal root resorption was firstly diagnosed with periapical radiographs and assessed with full detail with the aid of CBCT, allowing determination of the extension and areas involved in the resorption lesion, as well as the treatment planning. According to these findings, a MTA barrier was performed on the root, -coronally to the resorption lesion, leaving the root apically to the resorption lesion untouched. Clinical findings and periapical radiographs indicated complete resolution of the radiolucency associated with the resorptive defect, with reestablishment of lamina dura along the root and occlusion of the lumen of the root canal in the apical segment, after a 5-year follow-up.


Subject(s)
Root Canal Filling Materials , Root Resorption , Adult , Aluminum Compounds , Calcium Compounds/therapeutic use , Drug Combinations , Follow-Up Studies , Humans , Oxides , Root Canal Filling Materials/therapeutic use , Root Resorption/diagnostic imaging , Root Resorption/therapy , Silicates/therapeutic use
20.
Int Dent J ; 70(5): 328-339, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32501563

ABSTRACT

OBJECTIVES: The extent to which dentists are happy with their profession and their life has not been well studied. The present study aimed to explore the level of happiness, satisfaction with life and psychological well-being among a sample of dental professionals from 21 countries. MATERIALS AND METHODS: The sample comprised 2,200 dentists from 21 countries. Three scales - Subjective Happiness Scale (SHS), Satisfaction With Life Scale (SWLS), and Affect Balance Scale (ABS) - were used to measure the subjective responses. Data related to demographic and social characteristics were recorded. Mann-Whitney and Kruskal-Wallis tests were used as appropriate. Scales were correlated, and multiple linear regression analyses were employed to identify the independent determinants of SHS, SWLS and ABS. Data were analysed using the SPSS software program; a value of P <0.05 was considered significant. RESULTS: The overall mean scores of SHS, SWLS and ABS were 18.53 ± 5.06, 23.06 ± 6.25 and 1.26 ± 2.40, respectively, with significant differences found across countries: dentists working in Croatia, Peru and Serbia recorded the highest scores, unlike dentists practicing in Yemen, Syria, and Iraq, who recorded the lowest scores. There were significant, moderately positive correlations between the various scales: SHS and SWLS: r = 0.535, P < 0.001; SHS and ABS: r = 0.58, P < 0.001; and SWLS and ABS: r = 0.533, P < 0.001. Country of practice, age, qualification and monthly income were the significant independent predictors of SHS, SWLS and ABS. CONCLUSION: Country of residence and social characteristics were associated with dentists' responses regarding their feelings and subjective well-being.


Subject(s)
Happiness , Personal Satisfaction , Croatia , Dentists , Humans , Iraq , Quality of Life , Surveys and Questionnaires
SELECTION OF CITATIONS
SEARCH DETAIL
...