Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Small Anim Pract ; 64(11): 669-679, 2023 11.
Article in English | MEDLINE | ID: mdl-37452675

ABSTRACT

OBJECTIVES: To describe the change in the caudal vena cava to aorta ratio (CVC:Ao) ratio during fluid resuscitation of circulatory shock in dogs and compare these results with those of the physical examination and blood lactate. MATERIALS AND METHODS: Perfusion parameters and blood lactate were recorded at admission. An abdominal point-of-care ultrasound protocol was performed, during which the caudal vena cava to aorta ratio was measured on the spleno-renal view. Measurements were performed within 5 minutes before and after a 10 mL/kg crystalloid fluid bolus. Investigators were not blinded to therapeutic interventions. RESULTS: Twenty-nine dogs with physical signs of circulatory shock were enrolled. Caudal vena cava to aorta ratios were below reference interval in 28 of 29 dogs. After bolus administration, median caudal vena cava diameter increased by 0.14 cm (0.69 to 0.83 cm) and median aorta diameter increased by 0.03 cm (0.87 to 0.90 cm) and caudal vena cava to aorta ratio returned to within reference range in 65% of dogs (13/29). Bolus administration was associated with an increase in median caudal vena cava to aorta ratio of 0.10 (95% CI:0.05 to 0.16, P=0.0005). Blood lactate did not change significantly. Heart rate and capillary refill time decreased significantly after fluid bolus (heart rate: estimate=-19 bpm, 95% CI:-30 to -8, P=0.002; capillary refill time: estimate=-1.0 s, 95% CI:-1.3 to -0.7, P < 0.0001). CLINICAL SIGNIFICANCE: In this population of dogs with circulatory shock, the caudal vena cava to aorta ratio significantly increased after a fluid bolus. Future studies that implement blinding of the outcome assessors are warranted to confirm these findings.


Subject(s)
Aorta , Fluid Therapy , Dogs , Animals , Aorta/diagnostic imaging , Fluid Therapy/veterinary , Vena Cava, Inferior/diagnostic imaging , Ultrasonography/veterinary , Lactates
2.
J Small Anim Pract ; 59(3): 174-182, 2018 03.
Article in English | MEDLINE | ID: mdl-28960319

ABSTRACT

OBJECTIVES: The aims of this study were to describe a method for the sonographic assessment of volaemia, to determinate inter- and intra-operator variability and to assess the ability to detect blood loss after blood donation in healthy dogs. MATERIALS AND METHODS: The left kidney was identified in a spleno-renal view, and transverse views of the caudal vena cava and aorta were obtained in 12 dogs. Vessel diameters were measured in B-mode, in duplicate by two operators, and the caudal vena cava:aorta ratio was calculated. Intra- and inter-operator variabilities were assessed using a Bland-Altman method by plotting the differences between the repeated measurements obtained from the same subject by the same operator and by the two operators against their means. Before and after blood donation measurements were compared using paired t-tests or one-sample t-tests, if appropriate. RESULTS: Intra- and inter-operator variability was within the limit of agreement for the vast majority of measurements. After a blood donation of 9·8 ±2·2 mL/kg, the mean aorta measurements were not significantly different from those obtained before blood donation (1·11 versus 1·10, P=0·28), whereas the mean caudal vena cava measurements and caudal vena cava:aorta ratios were significantly lower (1·28 versus 1·01, P<0·0001; 1·17 versus 1·01, P=0·0001, respectively). CLINICAL SIGNIFICANCE: The low intra- and inter-operator variabilities in the caudal vena cava, aorta and caudal vena cava:aorta ratio measurements support their reliability and operator independency. The sonographic assessment of volaemia appears to be a promising non-invasive, repeatable point-of-care ultrasound protocol for assessment and monitoring of blood loss. Further studies are needed to assess the sonographic assessment of volaemia protocol in spontaneously bleeding dogs.


Subject(s)
Aorta/diagnostic imaging , Blood Donors , Blood Volume/veterinary , Dogs/physiology , Vena Cava, Inferior/diagnostic imaging , Animals , Dogs/anatomy & histology , Female , Male , Prospective Studies , Reproducibility of Results , Ultrasonography/veterinary
SELECTION OF CITATIONS
SEARCH DETAIL
...