1.
Radiography (Lond) ; 30(1): 193-201, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38035433

ABSTRACT

INTRODUCTION: Radiographers' profession is constantly evolving, which demands adaptation of education and training programs to build up medical imaging and radiation therapy professionals (MIRTPs) that provide healthcare to improve patient experience and outcomes. This study aimed to map radiographers' practices, competences, and autonomy level in Western Switzerland. METHODS: Data was collected by 2 cross-sectional online surveys targeting Alumni, radiographers, clinical placement tutors and medical imaging equipment specialists from industry, with opened and closed-end questions. Descriptive statistics and thematic analysis were used to analyse the data. RESULTS: 81 Alumni and 93 Chief-Radiographers, clinical tutors, practitioner-radiographers and industry answered the questionnaires. The competences considered as the most "acquired or completely acquired" by the Alumni were: adopt a reflective posture on practice (90.1 %; 73/81), adopt ethical behaviour (90.1 %; 73/81), carrying out and providing radiological services for diagnostic, therapeutic and preventive purposes (81.5 %; 68/81), adapting communication to the other surrounding persons (81.5 %; 66/81), and check compliance of procedures with standards (69.1 %; 56/81). Similar results were referred by Employers. The autonomy of the participant radiographers was considered as average, and it focuses only the preparation of the patient and the protocol optimisation. The development and integration of research is weak as well as the application of competences regarding professionalism. CONCLUSIONS: A better link between educational institutions and clinical practice can help on the integration of research and evidence-based on practice, necessary to progress the radiographers' profession in Western Switzerland. The autonomy needs to be further developed and leadership courses must be integrated in the curricula to facilitate the implementation of new approaches to reinforce radiographer's profession. IMPLICATIONS FOR PRACTICE: Practice must be revised to integrate evidence-based; to facilitate research development, the managers need to increase support.


Subject(s)
Allied Health Personnel , Diagnostic Imaging , Humans , Cross-Sectional Studies , Switzerland , Radiography
2.
Radiography (Lond) ; 30(1): 359-366, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38141429

ABSTRACT

INTRODUCTION: Imaging of the cervical spine in general radiography is most frequently performed using an anti-scatter grid. The purpose of this study was to investigate the effects of a gridless setting on image quality and radiation dose during digital radiography of the anteroposterior (AP) and lateral (LAT) cervical spine. METHODS: A phantom study was performed with a variety of tube voltages (63-75 kV) with and without an anti-scatter grid. The tube current time product (mAs) and dose area product (DAP) were recorded and used to calculate effective dose (ED) and individual organ dose using PCXMC 2.0 software, as well as entrance surface dose (ESD) and objective image quality: signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR). Subjective visual image quality grading characteristics (VGC) was performed by five qualified radiographers. RESULTS: In a gridless setting, the AP and LAT positions showed significantly lower DAP (1.6 µGym2; 61.3 % and 1.6 µGym2; 51.2%), ESD (27.6 µGy; 57.3% and 77.2 µGy; 47.2%) and ED (4.2 µSv; 61.3% and 2.3 µSv; 48.9%). In a gridless setting in the AP position, there is a slight significant deterioration in image quality. In the lateral projection, on the other hand, the image quality without the use of grid was only significantly reduced in three of six criteria and there was no difference in the objective image quality between the two settings examined. CONCLUSION: The results of this study show that gridless setting significantly decreases radiation dose and image quality, but the quality in the lateral projection is still acceptable for diagnostic purpose. IMPLICATIONS FOR PRACTICE: The protocol without the use of the anti-scatter grid in cervical spine radiography leads to a reduction in the radiation dose in both projections, but the image quality in the AP is significantly reduced for all criteria examined, with a slight deterioration in image quality in the lateral projection.


Subject(s)
Cervical Vertebrae , Software , Adult , Humans , Radiation Dosage , Radiography , Cervical Vertebrae/diagnostic imaging , Phantoms, Imaging