Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 40
Filter
2.
Article in English | MEDLINE | ID: mdl-39135541

ABSTRACT

PURPOSE: Kinematically aligned total knee arthroplasty (KA TKA), as a pure resurfacing procedure, is based on matching implant thickness with bone cut and kerf thickness, plus cartilage wear. However, the assumption of a consistent 2 mm femoral cartilage thickness remains unproven. This study aimed to systematically review the available literature concerning magnetic resonance imaging (MRI) assessment of femoral cartilage thickness in non-arthritic patients. Our hypothesis was that cartilage thickness values would vary significantly among individuals, thereby challenging the established KA paradigm of 'one-cartilage-fits-all'. METHODS: Systematic literature searches (Pubmed, Scopus and Cochrane Library) followed PRISMA guidelines. English-language studies assessing distal and posterior femoral cartilage thickness using MRI in non-arthritic adults were included. Studies lacking numerical cartilage thickness data, involving post-operative MRI, considering total femoro-tibial cartilage thickness, or failing to specify the compartment of the knee being studied were excluded. RESULTS: Overall, 27 studies comprising 8170 MRIs were analysed. Weighted mean femoral cartilage thicknesses were: 2.05 ± 0.62 mm (mean range 1.06-2.6) for the distal medial condyle, 1.95 ± 0.4 mm (mean range 1.15-2.5) for the distal lateral condyle, 2.44 ± 0.5 mm (mean range 1.37-2.6) for the posterior medial condyle and 2.27 ± 0.38 mm (mean range 1.48-2.5) for the posterior lateral condyle. DISCUSSION: Femoral cartilage thickness varies significantly across patients. In KA TKA, relying on a fixed thickness of 2 mm may jeopardize the accurate restoration of individual anatomy, leading to errors in implant coronal and rotational alignment. An intraoperative assessment of cartilage thickness may be advisable to express the KA philosophy at its full potential. LEVEL OF EVIDENCE: Level IV.

3.
Orthop Rev (Pavia) ; 16: 120053, 2024.
Article in English | MEDLINE | ID: mdl-38947178

ABSTRACT

Introduction: Hip-knee-ankle angle (HKA) on Full Limb Radiographs (FLRs) is the gold standard for coronal knee alignment assessment. Despite the widespread utilization of the more convenient femorotibial angle (FTA) on either antero-posterior (AP) or postero-anterior (PA) short knee radiographs (SKRs), its definition and correlation with HKA remains controversial. This review is the first to systematically investigate FTA-HKA correlation and the effect of different FTA methods and SKRs. Methods: Systematic literature search (Pubmed, Scopus, Cochrane Library) followed PRISMA guidelines, to evaluate studies examining the FTA-HKA correlation. Meta-analyses compared the 3 most common FTA methods, knee center determination method and SKR types. Results: 17 studies (2597 patients, 3234 knees) were included. The strongest correlation with HKA (r = 0.78) was found for FTA Method 1 (angle formed by lines drawn from the midpoint of tibial spines to points 10 cm above and below the joint line). No significant differences were observed when grouping the FTA methods by knee center assessment (Group I, r = 0.78; Group II, r = 0.77). AP SKRs showed a trend towards stronger FTA-HKA correlation compared to PA SKRs, in both Method 1 (r = 0.79 vs 0.75) and Method 3 (r = 0.80 vs 0.66). Conclusion: Irrespective of its definition or type of SKR used, FTA lacks reliable accuracy in predicting the HKA in most knees. FLRs should be used whenever precise estimation of the patient's alignment is necessary. Caution is warranted in interpreting studies investigating knee alignment or knee arthroplasty outcomes based on FTA.

4.
Article in English | MEDLINE | ID: mdl-38984905

ABSTRACT

PURPOSE: Patient dissatisfaction rates following total knee arthroplasty (TKA) reported in the literature reach 20%. The optimal coronal alignment is still under debate. The aim of this retrospective study was to compare clinical outcomes in different coronal plane alignment of the knee (CPAK) phenotypes undergoing mechanically aligned (MA) TKA. The hypothesis was that knees with preoperative varus arithmetic hip-knee-ankle angle (aHKA) would achieve inferior clinical outcomes after surgery compared to other aHKA categories. Additionally, another objective was to assess CPAK phenotypes distribution in the study population. METHODS: A retrospective selection was made of 180 patients who underwent MA TKA from April 2021 to December 2022, with a 1-year follow-up. Coronal knee alignment was classified according to the CPAK classification. Clinical outcome evaluations were measured using the Knee Society Score (KSS), Oxford Knee Score (OKS), Short Form Survey 12 and Forgotten Joint Score (FJS). Differences in clinical outcomes were considered statistically significant with a p value <0 .05. RESULTS: Patients with varus aHKA achieved significantly inferior outcomes at final follow-up compared to other aHKA categories in KSS pt. 1 (79.7 ± 17.2 vs. 85.6 ± 14.7; p = 0.028), OKS (39.2 ± 9.2 vs. 42.2 ± 7.2; p = 0.019) and FJS (75.4 ± 31.0 vs. 87.4 ± 22.9; p =0 .003). The most common aHKA category was the varus category (39%). The most common CPAK phenotypes were apex distal Types I (23.9%), II (22.8%) and III (13.3%). CONCLUSION: MA TKA does not yield uniform outcomes across all CPAK phenotypes. Varus aHKA category shows significantly inferior results at final follow-up. The most prevalent CPAK categories are varus aHKA and apex distal JLO, with phenotypes I, II and III being the most common. However, their gender distribution varies significantly. LEVEL OF EVIDENCE: Level IV.

5.
Medicina (Kaunas) ; 60(7)2024 Jul 19.
Article in English | MEDLINE | ID: mdl-39064599

ABSTRACT

Background and Objectives: Knee osteoarthritis is a serious burden for modern countries. Timing of surgery and treatment choice are still a matter of controversy in the orthopedic literature. The purpose of this study was to ascertain the incidence and hospitalization trends of high tibial osteotomy in Italy from 2001 to 2016. Materials and Methods: Data are sourced from the National Hospital Discharge Reports (SDO) of the Italian Ministry of Health between 2001 and 2016. Results: A total of 34,402 high tibial osteotomies were performed over the study period in Italy. The cumulative incidence was 3.6 cases per 100,000 residents. The age classes 50-54, 55-59 showed the higher number of procedures. In pediatric patients (0-19 years), high tibial osteotomies are also largely performed. The majority of patients having surgery were men with a M/F ratio of 1.5. The mean age of patients was 44.2 ± 19.2 years. Males were significantly younger than females (43.3 ± 20.7 vs. 45.6 ± 17.7). The average length of hospitalization was 6.1 ± 7.3 days. Over the course of the analysis, a declining trend in hospital stay length was seen. The main primary diagnosis codes were "Varus knee" (736.42 ICD-9-CM code, 33.9%), "Osteoarthrosis, localized, primary, leg region" (715.16 ICD-9-CM code, 9.5%). Conclusions: Over the study period, high tibial osteotomies in Italy almost halved. Varus deformity and knee osteoarthritis are the leading causes requiring high tibial osteotomy. Except for the pediatric setting, results showed that from the 20-24 age class to the 50-54 age class, there was an increasing request for knee osteotomy, whereas in those aged >60 years, the incidence progressively decreased. The evident decline in HTO performed over the years in Italy seems to reflect a minor role for knee osteotomy in the management of knee OA, as it seems to be primarily reserved for younger male patients.


Subject(s)
Osteoarthritis, Knee , Osteotomy , Registries , Tibia , Humans , Italy/epidemiology , Male , Osteotomy/methods , Osteotomy/statistics & numerical data , Osteotomy/trends , Female , Middle Aged , Tibia/surgery , Osteoarthritis, Knee/surgery , Osteoarthritis, Knee/epidemiology , Adult , Aged , Adolescent , Child , Incidence , Child, Preschool , Length of Stay/statistics & numerical data , Infant , Young Adult
7.
BMC Surg ; 24(1): 172, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38822306

ABSTRACT

BACKGROUND: Several studies have compared the pros and cons of simultaneous bilateral versus staged bilateral hip and knee replacement but the outcomes of these two surgical options remains a matter of controversy. This study aimed to evaluate demographic features, incidence and hospitalization rates of bilateral one stage total hip and knee arthroplasty in Italy. METHODS: The Italian Ministry of Health's National Hospital Discharge Reports (SDO) were used to gather data. This study referred to the adult population (+ 20 years of age) from 2001 to 2015 for hip arthroplasty and from 2001 to 2016 for knee arthroplasty. RESULTS: Overall, 1,544 bilateral simultaneous hip replacement were carried out. The incidence rate was 0.21 cases per 100,000 adult Italian residents. Male/female ratio was 1.1. The average days of hospital stay was 11.7 ± 11.8 days. The main primary codified diagnosis was: osteoarthrosis, localized, primary, pelvic region and thigh (ICD code: 715.15). 2,851 bilateral simultaneous knee replacement were carried out. The incidence rate was 0.37 cases per 100,000 adult Italian residents. Male/female ratio was 0.6. The average days of hospital stay was 7.7 ± 5.8 days. The main primary codified diagnosis was: osteoarthrosis, localized, primary, lower leg (ICD code: 715.16). CONCLUSIONS: The burden of hip and knee osteoarthrosis as a leading cause of bilateral joint replacement is significant in Italy. The national registers' longitudinal analysis may provide data for establishing international guidelines regarding the appropriate indications for one stage bilateral simultaneous hip or knee replacement versus two stage.


Subject(s)
Arthroplasty, Replacement, Hip , Arthroplasty, Replacement, Knee , Length of Stay , Humans , Male , Arthroplasty, Replacement, Hip/statistics & numerical data , Female , Arthroplasty, Replacement, Knee/statistics & numerical data , Italy/epidemiology , Middle Aged , Aged , Incidence , Adult , Length of Stay/statistics & numerical data , Osteoarthritis, Hip/surgery , Osteoarthritis, Hip/epidemiology , Aged, 80 and over , Osteoarthritis, Knee/surgery , Osteoarthritis, Knee/epidemiology , Retrospective Studies , Hospitalization/statistics & numerical data
8.
Knee ; 47: 151-159, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38394994

ABSTRACT

BACKGROUND: The safety and the clinical success of simultaneous bilateral total knee arthroplasty (BTKA) is controversial. The aim of this study was to compare complications and patient-reported outcomes following simultaneous BTKA (simBTKA) versus staged BKTA (staBTKA) in patients affected by bilateral symptomatic end-stage knee osteoarthritis (OA). METHODS: Data from patients who underwent simBTKA or staBTKA at a single institution from January 2017 to December 2020, with a minimum 1-year follow up period were retrospectively collected. Differences in terms of complications and clinical success were compared among the simBTKA and staBTKA patient groups. Alpha was set at 0.05. RESULTS: A total of 173 patients were included in this study. The results revealed no statistically significant differences between the two groups in terms of mortality, revision rate, readmission rate, local and systemic complications and patient-reported outcomes. SimBTKA group had a shorter operating room time (96 (73-119) vs. 195 (159-227); P < 0.0001), and length of hospital stay (4 (3-5) vs. 7 (6-9); P < 0.0001) compared with the staBTKA group. CONCLUSIONS: SimBTKA performed in a selected patient population at a high-volume center can be considered comparable to staBTKA in terms of safety, postoperative complications, 30-day readmissions and patient satisfaction. Consequently, reduced operating room time and hospital stay renders simBTKA a cost-effective and advantageous option, not only for patients, but also for healthcare institutes. Furthermore, the current study also highlights the importance of correct patient selection based on clinical preoperative characteristics.


Subject(s)
Arthroplasty, Replacement, Knee , Osteoarthritis, Knee , Patient Readmission , Patient Reported Outcome Measures , Postoperative Complications , Reoperation , Humans , Arthroplasty, Replacement, Knee/methods , Male , Female , Patient Readmission/statistics & numerical data , Aged , Osteoarthritis, Knee/surgery , Retrospective Studies , Middle Aged , Postoperative Complications/epidemiology
9.
Knee Surg Sports Traumatol Arthrosc ; 32(2): 405-417, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38298004

ABSTRACT

PURPOSE: There is concern that using cementless components may increase polyethylene wear of the Oxford unicompartmental knee replacement (OUKR). Therefore, this study aimed to measure bearing wear at 10 years in patients from a randomized trial comparing Phase 3 cemented and cementless OUKRs and to investigate factors that may affect wear. It was hypothesized that there would be no difference in wear rate between cemented and cementless OUKRs. METHODS: Bearing thickness was determined using radiostereometric analysis at postoperative, 3-month, 6-month, 1-year, 2-year, 5-year and 10-year timepoints. As creep occurs early, wear rate was calculated using linear regression between 6 months and 10 years for 39 knees (20 cemented, 19 cementless). Associations between wear and implant, surgical and patient factors were analysed. RESULTS: The linear wear rate of the Phase 3 OUKR was 0.06 mm/year with no significant difference (p = 0.18) between cemented (0.054 mm/year) and cementless (0.063 mm/year) implants. Age, Oxford Knee Score, component size and bearing thickness had no correlation with wear. A body mass index ≥ 30 was associated with a significantly lower wear rate (p = 0.007) as was having ≥80% femoral component contact area on the bearing (p = 0.003). Bearings positioned ≥1.5 mm from the tibial wall had a significantly higher wear rate (p = 0.002). CONCLUSIONS: At 10 years, the Phase 3 OUKR linear wear rate is low and not associated with the fixation method. To minimize the risk of wear-related bearing fracture in the very long-term surgeons should consider using 4 mm bearings in very young active patients and ensure that components are appropriately positioned, which is facilitated by the current instrumentation. LEVEL OF EVIDENCE: Level III, retrospective comparative study.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Polyethylene , Retrospective Studies , Osteoarthritis, Knee/surgery , Prosthesis Design , Prosthesis Failure , Treatment Outcome
10.
J Clin Med ; 12(24)2023 Dec 11.
Article in English | MEDLINE | ID: mdl-38137685

ABSTRACT

Patient-Reported Outcome Measures (PROMs) are standardized questionnaires that gather information on health-related quality of life directly from patients. Since a significant statistical mean change may not correspond to a clinical improvement, there is a need to calculate a considerable change in scores. This is done by the Minimum Clinically Important Difference (MCID) and Patient Acceptable Symptom State (PASS). The objective of this article is to report the MCID and the PASS values of the WOMAC (Western Ontario and McMaster University) osteoarthritis index for patients undergoing Unicompartmental Knee Arthroplasty (UKA). A total of 37 patients (25 females and 12 males; mean age 68 ± 8.1 years and mean BMI 28.7 ± 4) who underwent UKA were enrolled. All patients were assessed using the WOMAC and the Oxford Knee Score (OKS) questionnaires before and six months following the procedure. To measure the cut-off values for MCID, distribution methods and anchor methods were applied, while the PASS was assessed only via anchor approaches. The MCID related to the WOMAC average global score was 90.7 ± 7.6, the average pain dimension score was 93.2 ± 6.6, the average stiffness dimension score was 92.6 ± 17, and the average physical function dimension score was 89.7 ± 7.6. In terms of PASS, the normalized WOMAC was 82.8, the pain dimension was 87.5, the stiffness dimension was 93.7, and the functional dimension was 83.1. A 34.5 amelioration in the WOMAC score, from initial evaluation to final follow-up, using change in OKS > 5 as anchor, indicates that the patients' health state improved to a clinically significant degree. A value at least of 82.8 in WOMAC score after treatment denotes that the symptom state is deemed acceptable by most of the patients.

11.
Knee ; 45: 137-146, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37925804

ABSTRACT

BACKGROUND: In recent years, kinematic alignment (KA) is becoming a valid alternative to mechanical alignment (MA) in total knee arthroplasty (TKA). However, to avoid early failures, the restricted kinematic alignment (rKA) approach has been developed to restore native knee kinematics without reproducing extreme knee phenotype. This systematic review aims to evaluate clinical and radiological outcomes between rKA and MA for TKA. METHODS: A systematic literature search was conducted following PRISMA guidelines on Pubmed, Scopus and Cochrane Library. The following search string was adopted: (((restricted kinematic) AND (mechanical)) AND (alignment)) AND (knee). We included studies that analyzed rKA versus MA in terms of clinical outcomes and complications with a minimum of 6 months of follow up. The following rKA- and MA-related data were evaluated: patient-reported outcome scores (PROMs), radiographic analysis of lower limb alignment, and complications. Criteria from the Methodological Index for Non-Randomized Studies were used to assess the methodological quality of the articles. RESULTS: This systematic review included seven clinical studies with a total of 892 knees (471 for MA group and 421 for rKA group, respectively). Overall, post-operative PROMs were similar between rKA and MA. Moreover, rKA reached better results regarding Forgotten Joint Score and post-operative patient satisfaction. Finally, no higher complication rate was observed with the rKA approach. CONCLUSION: The rKA aims to restore native knee kinematics, avoiding extreme deformities. Clinical outcomes are not inferior or even better for rKA compared with MA, without increasing the risk of short-middle-term implant failure. However, there is a high heterogeneity regarding the 'restricted' protocols used.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Biomechanical Phenomena , Arthroplasty, Replacement, Knee/methods , Knee Joint/diagnostic imaging , Knee Joint/surgery , Lower Extremity , Radiography , Osteoarthritis, Knee/surgery
12.
J Clin Med ; 12(18)2023 Sep 16.
Article in English | MEDLINE | ID: mdl-37762946

ABSTRACT

Instability is one of the causes of failure in total knee arthroplasty (TKA). The aim of this study was to analyze the correlation between objective ligament laxity and the clinical outcome of mechanically aligned TKA. Fifty-one knees in 47 patients were evaluated at a minimum follow-up of 6 months. The correlation between the angular displacement and functional scores (Knee Society Score and Knee Injury and Osteoarthritis Score) was analyzed. A negative correlation (p-value < 0.05) was observed between medial laxity ≥5° at 0, 30, 60, and 90° of flexion and the outcome measures. Lateral laxity did not correlate with the clinical outcome. At 30° of knee flexion, a total varus and valgus laxity ≥10° was related to poorer outcomes. The same amount of angular displacement did not influence the outcome in the other flexion angles. There was no difference in single-radius vs multi-radius implants in terms of medial and lateral laxity and clinical outcome. A valgus displacement ≥5° measured at 0, 30, 60, and 90 degrees of flexion correlated with an inferior clinical outcome. In contrast, the same amount of displacement measured on the lateral compartment did not influence the clinical outcome after TKA.

13.
Orthop Rev (Pavia) ; 15: 73916, 2023.
Article in English | MEDLINE | ID: mdl-37405275

ABSTRACT

Introduction: The role of unicompartmental knee arthroplasty (UKA) in spontaneous osteonecrosis of the knee (SONK) is still controversial. Materials and methods: We performed a systematic review to evaluate all available current literature on UKA in the setting of SONK. A comprehensive electronic research was performed using the PubMed, Embase, Web of Science, and Cochrane databases with keywords related to SONK and knee arthroplasty. Studies were selected with predetermined inclusion criteria: 1) studies that specifically assessed SONK treated with UKA; 2) studies reporting implant survival rate and global clinical outcomes; 3) studies with a minimum follow up of 1 year. We excluded articles not written in English, articles that did not differentiate between primary and secondary osteonecrosis and articles published before 2000. Results: The overall research process produced 19 studies. We extrapolated data of a total of 717 unicompartimental knee arthroplasty procedures (1,39% lateral UKA, 98,61% medial UKA). Extracted data include years of follow-up, patient demographics, laterality of lesion, radiological findings, unicompartimental knee arthroplasty implants, reason of revision, revision rate, maximum knee flexion, knee clinical outcomes score, and Kaplan-Meier survival curves. The data collected show that UKA had acceptable survival rates as well as revision rates and good clinical outcomes both in the short- and long-term. Conclusion: UKA is an optimal treatment choice for primary SONK when correctly indicated in a carefully selected subset of patients, with no significant difference compared to osteoarthritis. Attention must be paid to distinguish the primary from secondary SONK, as the latter could lead to worse outcomes.

15.
Knee Surg Sports Traumatol Arthrosc ; 31(2): 407-412, 2023 Feb.
Article in English | MEDLINE | ID: mdl-34596693

ABSTRACT

PURPOSE: Postoperative instability represents one of the most common complications following primary total knee arthroplasty (TKA). To prevent this outcome, valgus deformities have been historically treated using more constrained implants. The purpose of this study was to evaluate the outcome of treating a moderate valgus deformity by combining a surgical technique used to release the postero-lateral soft tissue envelope with the use of a medially congruent (MC) TKA design without using classical, semi-constrained inserts. METHODS: Seventy-nine MC TKAs were performed by three surgeons at three institutions between 2016 and 2018 as part of a multicenter, international study. Inclusion criteria were: radiographic late-stage osteoarthritic knees with Ranawat's type 1 or 2 classification of valgus deformity and integrity of the medial capsular-ligament complex (less than 10 mm of medial opening during valgus stress test at 10° of knee flexion). Exclusion criteria were: BMI > 40; neuromuscular, metabolic, or immunologic disorders; or the inability to complete outcome measures or radiographic assessment. RESULTS: Seventy-seven patients (79 knees), 59 males and 18 females, were evaluated at 2-year minimum follow-up according to the Knee Society Score (KSS) and Forgotten Joint Score (FJS). Mean age at surgery was 70 years (range 48-91). The mean range of motion (ROM) improved from 110° (range 85°-130°) preoperatively to 121° (range 105°-135°) (p < 0.001) at the time of the last follow-up. Preoperative knee extension significantly improved from 3° (range - 15° to 20°) to 1° (range - 5° to 5°) of flexion at the last follow-up in all the patients. KSS and KSS Functional scores were 89 (range 65-100) and 82 points (range 55-100), respectively. The FJS obtained at the last follow-up was 72 (range 49-88). Two patients (2.5%) had major postoperative complications (one periprosthetic joint infection; one postoperative patellar fracture) requiring surgical interventions. CONCLUSIONS: In different surgeon's hands, the use of a modern medially congruent TKA design yielded good clinical outcomes at 2 years in a consecutive series of TKA in valgus arthritic knees. Postoperative instability was not recorded in this series and this finding was related to the high conformity design of the MC polyethylene insert, which significantly differs from classical posterior-stabilized (PS) designs. LEVEL OF EVIDENCE: IV.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Male , Female , Humans , Middle Aged , Aged , Aged, 80 and over , Arthroplasty, Replacement, Knee/methods , Knee Joint/diagnostic imaging , Knee Joint/surgery , Range of Motion, Articular , Polyethylene
16.
J Clin Med ; 11(8)2022 Apr 17.
Article in English | MEDLINE | ID: mdl-35456339

ABSTRACT

This systematic review of the literature aimed to highlight which criteria are described in the literature to define when a patient, after rotator cuff repair (RCR), is ready for return-to-play (RTP), which includes return to unrestricted activities, return to work, leisure, and sport activities. An online systematic search on the US National Library of Medicine (PubMed/MEDLINE), SCOPUS, Web of Science (WOS), and the Cochrane Database of Systematic Reviews, was performed with no data limit until December 2021. A total of 24 studies that reported at least one criterion after RCR were included. Nine criteria were identified and among these, the most reported criterion was the time from surgery, which was used by 78% of the studies; time from surgery was used as the only criterion by 54% of the studies, and in combination with other criteria, in 24% of the studies. Strength and ROM were the most reported criteria after time (25%). These results are in line with a previous systematic review that aimed to identify RTP criteria after surgical shoulder stabilization and with a recent scoping review that investigated RTP criteria among athletes after RCR and anterior shoulder stabilization. Compared to this latest scoping review, our study adds the methodological strength of being conducted according to the Prisma guidelines; furthermore, our study included both athletes and non-athletes to provide a comprehensive view of the criteria used after RCR; moreover, ten additional recent manuscripts were examined with respect to the scoping review.

17.
J Clin Med ; 10(19)2021 Sep 22.
Article in English | MEDLINE | ID: mdl-34640308

ABSTRACT

This systematic review aimed to investigate the clinical and functional outcomes and complication rate of simultaneous anterior cruciate ligament reconstruction (ACLR) and unicompartmental knee arthroplasty (UKA). A systematic search in PubMed-Medline, Cochrane Library, and Google Scholar was carried out to identify eligible randomized clinical trials, observational studies, or case series that reported on clinical and functional results of combined ACLR and UKA in adults with a unicompartmental knee osteoarthritis and ACL deficiency. Four retrospective studies and three prospective studies were included in this review. A total of 169 patients were included with a mean follow-up of 6.3 years. The Mean Oxford Knee Score improved from 29.4 to 43.9 at the final follow-up. All the other reported scores significantly improved after surgery. The overall revision rate was 3.5%. The MINORS score ranged from 8 to 14. Association analysis of MINORS score and year of publication, through Pearson's coefficient, showed no significant association (p = -0.089). Simultaneous ACLR and UKA is a safe procedure with a significant postoperative improvement of functional and clinical outcomes for patients with ACL injury that complain of knee instability and isolated medial compartment pain.

18.
J Clin Med ; 10(16)2021 Aug 05.
Article in English | MEDLINE | ID: mdl-34441765

ABSTRACT

BACKGROUND: Proprioception is an important part of the somatosensory system involved in human motion control, which is fundamental for activities of daily living, exercise, and sport-specific gestures. When total knee arthroplasty (TKA) is performed, the posterior cruciate ligament (PCL) can be retained, replaced, or discarded. The PCL seems to be responsible for maintaining the integrity of the joint position sense (JPS) and joint kinesthesia. The aim of this review was to assess the effect of PCL on knee joint proprioception in total knee replacement. METHODS: This systematic review was conducted within five electronic databases: PubMed, Scopus, Web of Science, Cochrane, and PEDro with no data limit from inception to May 2021. RESULTS: In total 10 publications were evaluated. The analysis was divided by proprioception assessment method: direct assessment (JPS, kinesthesia) and indirect assessment (balance). CONCLUSIONS: The current evidence suggest that the retention of the PCL does not substantially improve the joint proprioception after TKA. Due to the high heterogeneity of the studies in terms of design, proprioception outcomes, evaluation methods, further studies are needed to confirm the conclusions. In addition, future research should focus on the possible correlation between joint proprioception and walking function.

19.
J Clin Med ; 10(16)2021 Aug 15.
Article in English | MEDLINE | ID: mdl-34441889

ABSTRACT

Thanks to modern surgical techniques and implants, traditional exclusion criteria for unicompartmental knee arthroplasty (UKA) are no longer considered contraindications. The aim of this study is to clarify the impact of obesity on functional outcomes and revision rates of UKA. We performed a comprehensive systematic review using PubMed-Medline, Google Scholar and Cochrane Central. Then, we extracted data related to body mass index (BMI), age and follow-up, functional outcome scores and rate of revisions (all-cause, aseptic and septic). Patients were stratified according to BMI into two groups: non-obese (BMI < 30) and obese (BMI ≥ 30). We identified 22 eligible studies, of which 13 were included in the meta-analysis. Patients with a BMI > 30 had a significantly higher likelihood for revision (p = 0.02), while the risk of septic revision was similar (p = 0.79). The clinical outcome measures showed a significant difference in favor of patients with a BMI < 30 (p < 0.0001). The improvements in Oxford Knee Score and Knee Society Score were significant in both obese and non-obese patients, although the latter showed inferior results. The results of this systematic review and meta-analysis show that BMI is not a contraindication to UKA. However, obese patients have a higher risk for aseptic failure and lower improvement in clinical scores compared to non-obese patients.

20.
J Clin Med ; 10(15)2021 Jul 29.
Article in English | MEDLINE | ID: mdl-34362138

ABSTRACT

Despite the globally ascertained success of Total Knee Arthroplasty (TKA) procedure, 20% of patients are still unsatisfied with the surgery results. The purpose of the study is to identify the functional and radiological outcomes of the computer-assisted (CAS) TKA compared to the conventional technique. The clinical databases and medical records of both clinical sites were retrospectively analyzed, and then according to study time-lapse, inclusion, and exclusion criteria, eligible patients were retrieved and included. A total of 42 patients that underwent to CAS TKA (NAVI) and 61 patients that underwent to Conventional TKA (CONV) were included. The NAVI group reported a statistically significant higher surgical time. A lower intraoperative blood loss was found in the computer-assisted group, though this difference was not statistically significant. Implant survival analysis at two years did not show differences between groups during the follow-up period. At two years, follow-up postoperative intergroup analysis showed no statistically significant difference between groups. According to the radiologic analysis, the NAVI group showed comparable outcomes to the conventional group. The present study showed that there was no clinical and radiological difference between CAS arthroplasty and conventional technique.

SELECTION OF CITATIONS
SEARCH DETAIL