Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Radiol ; 2024 Feb 06.
Article in English | MEDLINE | ID: mdl-38319428

ABSTRACT

OBJECTIVES: This study aimed to externally validate the Birmingham Atypical Cartilage Tumour Imaging Protocol (BACTIP) recommendations for differentiation/follow-up of central cartilage tumours (CCTs) of the proximal humerus, distal femur, and proximal tibia and to propose BACTIP adaptations if the results provide new insights. METHODS: MRIs of 123 patients (45 ± 11 years, 37 men) with an untreated CCT with MRI follow-up (n = 62) or histopathological confirmation (n = 61) were retrospectively/consecutively included and categorised following the BACTIP (2003-2020 / Ghent University Hospital/Belgium). Tumour length and endosteal scalloping differences between enchondroma, atypical cartilaginous tumour (ACT), and high-grade chondrosarcoma (CS II/III/dedifferentiated) were evaluated. ROC-curve analysis for differentiating benign from malignant CCTs and for evaluating the BACTIP was performed. RESULTS: For lesion length and endosteal scalloping, ROC-AUCs were poor and fair-excellent, respectively, for differentiating different CCT groups (0.59-0.69 versus 0.73-0.91). The diagnostic performance of endosteal scalloping and the BACTIP was higher than that of lesion length. A 1° endosteal scalloping cut-off differentiated enchondroma from ACT + high-grade chondrosarcoma with a sensitivity of 90%, reducing the potential diagnostic delay. However, the specificity was 29%, inducing overmedicalisation (excessive follow-up). ROC-AUC of the BACTIP was poor for differentiating enchondroma from ACT (ROC-AUC = 0.69; 95%CI = 0.51-0.87; p = 0.041) and fair-good for differentiation between other CCT groups (ROC-AUC = 0.72-0.81). BACTIP recommendations were incorrect/unsafe in five ACTs and one CSII, potentially inducing diagnostic delay. Eleven enchondromas received unnecessary referrals/follow-up. CONCLUSION: Although promising as a useful tool for management/follow-up of CCTs of the proximal humerus, distal femur, and proximal tibia, five ACTs and one chondrosarcoma grade II were discharged, potentially inducing diagnostic delay, which could be reduced by adapting BACTIP cut-off values. CLINICAL RELEVANCE STATEMENT: Mostly, Birmingham Atypical Cartilage Tumour Imaging Protocol (BACTIP) assesses central cartilage tumours of the proximal humerus and the knee correctly. Both when using the BACTIP and when adapting cut-offs, caution should be taken for the trade-off between underdiagnosis/potential diagnostic delay in chondrosarcomas and overmedicalisation in enchondromas. KEY POINTS: • This retrospective external validation confirms the Birmingham Atypical Cartilage Tumour Imaging Protocol as a useful tool for initial assessment and follow-up recommendation of central cartilage tumours in the proximal humerus and around the knee in the majority of cases. • Using only the Birmingham Atypical Cartilage Tumour Imaging Protocol, both atypical cartilaginous tumours and high-grade chondrosarcomas (grade II, grade III, and dedifferentiated chondrosarcomas) can be misdiagnosed, excluding them from specialist referral and further follow-up, thus creating a potential risk of delayed diagnosis and worse prognosis. • Adapted cut-offs to maximise detection of atypical cartilaginous tumours and high-grade chondrosarcomas, minimise underdiagnosis and reduce potential diagnostic delay in malignant tumours but increase unnecessary referral and follow-up of benign tumours.

2.
Skeletal Radiol ; 52(8): 1605-1618, 2023 Aug.
Article in English | MEDLINE | ID: mdl-36602575

ABSTRACT

This is, to our knowledge, the first case report with in-depth analysis of bone marrow and bone lesions with diffusion-weighted imaging and dynamic contrast-enhanced MRI in Erdheim-Chester disease to date. We present a case of a 70-year-old woman who was referred for an X-ray of the pelvis, right femur and right knee after complaints of migratory arthralgia in hip and knee five months after an initial hip and knee trauma. Bone lesions on X-ray were identified. This case report highlights the strength and complementary use of modern multimodality multiparametric imaging techniques in the clinical radiological manifestations of Erdheim-Chester disease, in the differential diagnosis and in treatment response assessment, which is classically performed using 18FDG PET-CT. Erdheim-Chester disease is a rare form of non-Langerhans' cell histiocytosis, mainly affecting individuals in their fifth-seventh decade of life and without sex predominance. Apart from the typical bilateral symmetric lesions in long bone diaphyseal and metaphyseal regions and classically sparing the epiphyses, this multisystemic disease causes significant morbidity by infiltrating critical organs (the central nervous system, cardiovascular system, retroperitoneum, lungs and skin). With non-traumatic bone pain being the most common complaint, Erdheim-Chester disease is diagnosed most often in an incidental setting on imaging. The imaging workup classically consists of a multimodality approach using conventional radiography, CT, MRI, bone scintigraphy and 18FDG PET-CT. This case report extends this evaluation with diffusion-weighted imaging and dynamic contrast-enhanced imaging techniques.


Subject(s)
Erdheim-Chester Disease , Female , Humans , Aged , Erdheim-Chester Disease/diagnostic imaging , Erdheim-Chester Disease/pathology , Positron Emission Tomography Computed Tomography , Fluorodeoxyglucose F18 , Tomography, X-Ray Computed , Magnetic Resonance Imaging
3.
J Clin Monit Comput ; 36(6): 1881-1890, 2022 12.
Article in English | MEDLINE | ID: mdl-35318567

ABSTRACT

The use of inhaled anesthetics has come under increased scrutiny because of their environmental effects. This has led to a shift where sevoflurane in O2/air has become the predominant gas mixture to maintain anesthesia. To further reduce environmental impact, lower fresh gas flows (FGF) should be used. An accurate model of sevoflurane consumption allows us to assess and quantify the impact of the effects of lowering FGFs. This study therefore tested the accuracy of the Gas Man® model by determining its ability to predict end-expired sevoflurane concentrations (FETsevo) in patients using a protocol spanning a wide range of FGF and vaporizer settings. After IRB approval, 28 ASA I-II patients undergoing a gynecologic or urologic procedure under general endotracheal anesthesia were enrolled. Anesthesia was maintained with sevoflurane in O2/air, delivered via a Zeus or FLOW-i workstation (14 patients each). Every fifteen min, FGF was changed to randomly selected values ranging from 0.2 to 6 L/min while the sevoflurane vaporizer setting was left at the discretion of the anesthesiologist. The FETsevo was collected every min for 1 h. For each patient, a Gas Man® simulation was run using patient weight and the same FGF, vaporizer and minute ventilation settings used during the procedure. For cardiac output, the Gas Man default setting was used (= Brody formula). Gas Man®'s performance was assessed by comparing measured with Gas Man® predicted FETsevo using linear regression and Varvel's criteria [median performance error (MDPE), median absolute performance error (MDAPE), and divergence]. Additional analysis included separating performance for the wash-in (0-15 min) and maintenance phase (15-60 min). For the FLOW-i, MDPE, MDAPE and divergence were 1% [- 6, 8], 7% [3, 15] and - 0.96%/h [- 1.14, - 0.88], respectively. During the first 15 min, MDPE and MDAPE were 18% [1, 51] and 21% [8, 51], respectively, and during the last 45 min 0% [- 7, 5] and 6% [2, 10], respectively. For the Zeus, MDPE, MDAPE and divergence were 0% [- 5, 8], 6% [3, 12] and - 0.57%/h [- 0.85, - 0.16], respectively. During the first 15 min, MDPE and MDAPE were 7% [- 6, 28] and 13% [6, 32], respectively, and during the last 45 min - 1% [- 5, 5] and 5% [2, 9], respectively. In conclusion, Gas Man® predicts FETsevo in O2/air in adults over a wide range of FGF and vaporizer settings using different workstations with both MDPE and MDAPE < 10% during the first hour of anesthesia, with better relative performance for simulating maintenance than wash-in. In the authors' opinion, this degree of performance suffices for Gas Man® to be used to quantify the environmental impact of FGF reduction in real life practice of the wash-in and maintenance period combined.


Subject(s)
Anesthetics, Inhalation , Methyl Ethers , Adult , Male , Humans , Female , Sevoflurane , Anesthesia, Inhalation/methods , Nebulizers and Vaporizers
SELECTION OF CITATIONS
SEARCH DETAIL
...