Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
Braz J Cardiovasc Surg ; 38(2): I-V, 2023 03 23.
Article in English | MEDLINE | ID: mdl-36952550
2.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;38(2): I-V, 2023.
Article in English | LILACS-Express | LILACS | ID: biblio-1431511
5.
Cardiol Young ; 32(3): 415-419, 2022 Mar.
Article in English | MEDLINE | ID: mdl-34127174

ABSTRACT

BACKGROUND: Glenn procedure is performed for patients with cyanotic CHD and univentricular physiology and has a survival rate above 90%. AIM: To evaluate the risk factors associated with a poor outcome after Glenn procedure. METHODS: The data for this retrospective analysis were collected from a regional Brazilian registry of congenital heart surgeries (ASSIST initiative) from 2014 to 2019. Data from 97 patients who underwent the Glenn procedure were considered. The primary outcomes were prolonged mechanical ventilation (>24 hours post-operatively) or in-hospital death, alone and combined. RESULTS: The overall in-hospital mortality was 13.4% (n = 13). Prolonged mechanical ventilation occurred in 52% (n = 51) of the patients. Our analysis found that risk factors for death or prolonged post-operative mechanical ventilation were cardiopulmonary bypass duration and post-operative lactate, whereas weight-for-age z-score and age at surgery were risk factors for prolonged mechanical ventilation. Cardiopulmonary bypass duration increased (adjusted odds ratio: 1.02; 95 % CI: 1.01, 1.03) and age at surgery decreased (adjusted odds ratio: 0.96; 95 % CI: 0.93, 0.99) the odds of the combined outcome. CONCLUSIONS: Age at surgery, post-operative lactate, and low-weight-for-age z-score are associated with prolonged mechanical ventilation and death following the Glenn procedure.


Subject(s)
Fontan Procedure , Heart Defects, Congenital , Developing Countries , Fontan Procedure/methods , Heart Defects, Congenital/surgery , Hospital Mortality , Humans , Infant , Lactic Acid , Respiration, Artificial , Retrospective Studies , Risk Factors , Treatment Outcome
6.
J Card Surg ; 35(2): 328-334, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31782834

ABSTRACT

INTRODUCTION: The neutrophil-lymphocyte ratio (NLR) has been associated with worse outcomes in patients undergoing coronary artery bypass graft surgery. Little is known about this association in the pediatric population who require surgery for congenital heart defects, especially in patients with a single ventricle (SV). OBJECTIVE: To analyze the association of the preoperative NLR with outcomes in patients undergoing the bidirectional Glenn procedure. METHODS: This study involved a retrospective cohort analysis of 141 consecutive patients with SV undergoing the bidirectional Glenn procedure between January 2011 and December 2017 in two centers. The preoperative NLR was included in the last hemogram test before surgery. According to the NLR level, the patients were divided into group I (NLR < 1), group II (NLR between 1 and 2), and group III (NLR > 2). The primary endpoint was total hospital length of stay (LOS), and secondary endpoints were mechanical ventilation (MV) time, intensive care unit (ICU) LOS, ventricular dysfunction, complications, and middle-term mortality. RESULTS: The average follow-up duration was 48 months. There were 61, 47, and 33 patients in groups I, II, and III, respectively. Patients in group III exhibited an increased risk of prolonged total hospital LOS (P = .00). An increase in MV time (P = .03) and ICU LOS (P = .02) was also observed in this group, and these patients experienced greater mortality in 24 months following the surgery (P = .03). There was no association between the NLR and ventricular dysfunction (P = .26) and complications (P = .46). CONCLUSION: A high preoperative NLR was associated with worse outcomes in patients with SV physiology undergoing the bidirectional Glenn procedure.


Subject(s)
Cardiac Surgical Procedures/methods , Heart Defects, Congenital/surgery , Heart Ventricles/abnormalities , Heart Ventricles/surgery , Leukocyte Count , Lymphocyte Count , Neutrophils , Adult , Aged , Cohort Studies , Female , Follow-Up Studies , Humans , Male , Middle Aged , Postoperative Complications/epidemiology , Preoperative Period , Prognosis , Respiration, Artificial , Retrospective Studies , Time Factors
7.
Pediatr Cardiol ; 38(5): 981-990, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28500413

ABSTRACT

Central factors negatively affect the functional capacity of Fontan patients (FP), but "non-cardiac" factors, such as pulmonary function, may contribute to their exercise intolerance. We studied the pulmonary function in asymptomatic FP and its correlations with their functional capacity. Pulmonary function and cardiopulmonary exercise tests were performed in a prospective study of 27 FP and 27 healthy controls (HC). Cardiovascular magnetic resonance was used to evaluate the Fontan circulation. The mean age at tests, the mean age at surgery, and the median follow-up time of FP were 20(±6), 8(±3), and 11(8-17) years, respectively. Dominant ventricle ejection fraction was within normal range. The mean of peak VO2 expressed in absolute values (L/min), the relative values to body weight (mL/kg/min), and their predicted values were lower in FP compared with HC: 1.69 (±0.56) vs 2.81 (±0.77) L/min; 29.9 (±6.1) vs 41.5 (±9.3) mL/kg/min p < 0.001 and predicted VO2 Peak [71% (±14) vs 100% (±20) p < 0.001]. The absolute and predicted values of the forced vital capacity (FVC), forced expiratory volume in one second (FEV1), inspiratory capacity (IC), total lung capacity (TLC), diffusion capacity of carbon monoxide of the lung (DLCO), maximum inspiratory pressure (MIP), and sniff nasal inspiratory pressure (SNIP) were also significantly lower in the Fontan population compared to HC. An increased risk of restrictive ventilatory pattern was found in patients with postural deviations (OD:10.0, IC:1.02-97.5, p = 0.042). There was a strong correlation between pulmonary function and absolute peak VO2 [FVC (r = 0.86, p < 0.001); FEV1 (r = 0.83, p < 0.001); IC (r = 0.84, p < 0.001); TLC (r = 0.79, p < 0.001); and DLCO (r = 0.72, p < 0.001). The strength of the inspiratory muscles in absolute and predicted values was also reduced in FP [-79(±28) vs -109(±44) cmH2O (p = 0.004) and 67(±26) vs 89(±36) % (p = 0.016)]. Thus, we concluded that the pulmonary function was impaired in clinically stable Fontan patients and the static and dynamic lung volumes were significantly reduced compared with HC. We also demonstrated a strong correlation between absolute Peak VO2 with the FVC, FEV1, TLC, and DLCO measured by complete pulmonary test.


Subject(s)
Fontan Procedure/adverse effects , Heart Defects, Congenital/physiopathology , Heart Defects, Congenital/surgery , Lung/physiopathology , Respiration Disorders/physiopathology , Adolescent , Adult , Cross-Sectional Studies , Exercise Test , Exercise Tolerance/physiology , Female , Heart Defects, Congenital/complications , Humans , Male , Prospective Studies , Respiration Disorders/etiology , Respiratory Function Tests , Retrospective Studies , Young Adult
9.
Ann Thorac Surg ; 80(1): 330-1, 2005 Jul.
Article in English | MEDLINE | ID: mdl-15975399

ABSTRACT

We present the case of an asymptomatic 31-year-old man with perimembranous ventricular septal defect and aortic insufficiency due to a prolapsed right cusp. The ventricular septal defect was corrected with the rotation of the right cusp, and the Ross procedure was performed for the aortic insufficiency. The patient had an uneventful postoperative course. At immediate and first year follow-up examinations he presented with trivial aortic insufficiency and no residual ventricular septal defect. The patient remains asymptomatic with no medication.


Subject(s)
Cardiac Surgical Procedures , Heart Septal Defects, Ventricular/surgery , Heart Valve Diseases/surgery , Adult , Aortic Valve Insufficiency/surgery , Humans , Male
10.
J Thorac Cardiovasc Surg ; 124(5): 999-1006, 2002 Nov.
Article in English | MEDLINE | ID: mdl-12407385

ABSTRACT

OBJECTIVE: An experimental model with a reversible pulmonary trunk banding device was developed with the aim of inducing rapid ventricular hypertrophy. The device consists of an insufflatable cuff connected to a self-sealing button. METHODS: The right ventricles of 7 young goats (average weight, 8.7 kg) were submitted to systolic overload and evaluated according to the hemodynamic, echocardiographic, and morphologic aspects. Baseline biopsy specimens were taken from the myocardium for microscopic analysis. The device was implanted on the pulmonary trunk and inflated so that a 0.7 right ventricular/left ventricular pressure ratio was achieved. Echocardiographic and hemodynamic evaluations were performed every 24 hours. Systolic overload was maintained for 96 hours. The animals were then killed for morphologic study. Another 9 goats (average weight, 7.7 kg) were used for control right ventricular weight. RESULTS: The systolic right ventricular/pulmonary trunk pressure gradient varied from 10.1 +/- 4.3 mm Hg (baseline) to 60.0 +/- 11.0 mm Hg (final). Consequently, the right ventricular/left ventricular pressure ratio increased from 0.29 +/- 0.06 to 1.04 +/- 0.14. The protocol group showed a 74% increase in right ventricular mass when compared with the control group. Serial 2-dimensional echocardiography showed a 66% increase in right ventricular wall thickness. There was a 24% increase in the mean myocyte perimeter, and the myocyte area increased 61%. CONCLUSIONS: The device is easily adjustable percutaneously, enabling right ventricular hypertrophy in 96 hours of gradual systolic overload. This study suggests that the adjustable pulmonary trunk banding might provide better results for the 2-stage Jatene operation and for the failed atrial switch operations to convert to the double-switch operation.


Subject(s)
Heart Ventricles/pathology , Hypertrophy, Left Ventricular/etiology , Hypertrophy, Right Ventricular/etiology , Pulmonary Valve/pathology , Animals , Blood Pressure/physiology , Disease Models, Animal , Echocardiography, Doppler , Equipment Design/adverse effects , Goats , Heart Ventricles/cytology , Heart Ventricles/physiopathology , Hypertrophy, Left Ventricular/physiopathology , Hypertrophy, Right Ventricular/physiopathology , Microscopy , Models, Cardiovascular , Myocytes, Cardiac/metabolism , Organ Size/physiology , Pulmonary Valve/physiopathology , Stroke Volume/physiology , Systole/physiology , Ventricular Function, Left/physiology , Ventricular Pressure/physiology
11.
Rev. bras. cir. cardiovasc ; Rev. bras. cir. cardiovasc;15(4): 328-337, out.-dez. 2000. ilus, tab
Article in Portuguese | LILACS | ID: lil-281971

ABSTRACT

OBJETIVO: Um dispositivo de bandagem do tronco pulmonar (TP) com ajuste percutâneo foi desenvolvido com o objetivo de induzir a hipertrofia rápida do ventrículo subpulmonar. MATERIAL E MÉTODOS: Consiste de um manguito de silicone insuflável percutaneamente, através de um botão de silicone auto-selante. Os corações de 7 cabritos jovens (peso médio: 8,7 kg) foram submetidos à sobrecarga sistólica imposta pelo dispositivo e avaliados sob os aspectos hemodinâmicos, ecocardiográficos e morfológicos. Foram extraídas biópsias basais do miocárdio do ventrículo direito (VD) para análise microscópica (perímetro e área do miócito). O dispositivo foi implantado no TP. As pressões do VD, TP e aorta foram monitorizadas. Após convalescença, foi iniciado o protocolo de insuflação do dispositivo de bandagem do TP. Foi injetada água destilada no botão auto-selante (via percutânea), até que a pressão sistólica do VD atingisse 70 por cento da pressão sistólica do VE. As avaliações ecocardiográfica e hemodinâmica foram realizadas a cada 24 horas. A sobrecarga sistólica do VD foi mantida por um período de 96 horas, com insuflações progressivas no limite máximo tolerado, a cada 24 horas. Após esse período, os animais foram sacrificados para análise morfológica dos corações. Outros 9 cabritos (peso médio: 7,7 kg) foram utilizados como grupo controle, para análise do peso do VD. RESULTADOS: Após 96 horas de sobrecarga sistólica do VD, foi observado um aumento do gradiente sistólico VD/TP de 10,1 + ou - 4,3 mmHg para 60,0 + ou - 11,0 mmHg e da pressão sistólica no VD de 22,4 + ou - 4,1 mmHg para 71,0 + ou - 10,0 mmHg (p<0,0001). O ecocardiograma revelou aumento da espessura muscular do VD, de 4,4 + ou - 0,5 mm para 7,3 + ou - 1,7 mm (p=0,001). Quando comparado ao grupo controle, houve um ganho de peso de 74 por cento do VD submetido à sobrecarga sistólica (p<0,0001). À microscopia óptica, foi observado aumento de 27 por cento no perímetro e de 69 por cento na área dos miócitos (p=0,0001). CONCLUSÕES: O dispositivo proposto neste trabalho é efetivo e facilmente ajustável por via percutânea, possibilitando a hipertrofia do ventrículo subpulmonar em 96 horas de sobrecarga sistólica. A melhora na ajustabilidade da bandagem do TP poderá permitir melhores resultados da operação de Jatene em dois estágios, nos pacientes com transposição das grandes artérias


Subject(s)
Animals , Male , Bandages , Hypertrophy, Right Ventricular/etiology , Pulmonary Artery/surgery , Heart Ventricles/surgery , Catheterization , Insufflation/methods , Transposition of Great Vessels/surgery
SELECTION OF CITATIONS
SEARCH DETAIL