Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Br J Radiol ; 89(1066): 20160264, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27452265

ABSTRACT

OBJECTIVE: After breast conservative surgery (BCS) and whole-breast radiotherapy (WBRT), the use of boost irradiation is recommended especially in patients at high risk. However, the standard technique and the definition of the boost volume have not been well defined. METHODS: We retrospectively compared an anticipated pre-operative photon boost on the tumour, administered with low-dose fractionated radiotherapy, and neoadjuvant chemotherapy with two different sequential boost techniques, administered after BCS and standard adjuvant WBRT: (1) a standard photon beam (2) and an electron beam technique on the tumour bed of the same patients. The plans were analyzed for the dosimetric coverage of the CT-delineated irradiated volume. The minimal dose received by 95% of the target volume (D95), the minimal dose received by 90% of the target volume (D90) and geographic misses were evaluated. RESULTS: 15 patients were evaluated. The sequential photon and electron boost techniques resulted in inferior target volume coverage compared with the anticipated boost technique, with a median D95 of 96.3% (range 94.7-99.6%) and 0.8% (range 0-30%) and a median D90 of 99.1% (range 90.2-100%) and 54.7% (range 0-84.8%), respectively. We observed a geographic miss in 26.6% of sequential electron plans. The results of the anticipated boost technique were better: 99.4% (range 96.5-100%) and 97.1% (range 86.2-99%) for median D90 and median D95, respectively, and no geographic miss was observed. We observed a dose reduction to the heart, with left-sided breast irradiation, using the anticipated pre-operative boost technique, when analyzed for all dose-volume parameters. When compared with the sequential electron plans, the pre-operative photon technique showed a higher median ipsilateral lung Dmax. CONCLUSION: Our data show that an anticipated pre-operative photon boost results in a better coverage with respect to the standard sequential boost while also saving the organs at risk and consequently fewer side effects. ADVANCES IN KNOWLEDGE: This is the first dosimetric study that evaluated the association between an anticipated boost and neoadjuvant chemotherapy treatment.


Subject(s)
Breast Neoplasms/radiotherapy , Adult , Aged , Antineoplastic Combined Chemotherapy Protocols/therapeutic use , Breast Neoplasms/drug therapy , Breast Neoplasms/surgery , Dose Fractionation, Radiation , Female , Heart/radiation effects , Humans , Mastectomy, Segmental , Middle Aged , Neoadjuvant Therapy , Neoplasm Grading , Neoplasm Staging , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Retrospective Studies , Tomography, X-Ray Computed , Treatment Outcome
2.
Tumori ; 102(2): 184-9, 2016.
Article in English | MEDLINE | ID: mdl-26350194

ABSTRACT

PURPOSE: Breast cancer survivors have a high risk of cardiac death as a consequence of heart irradiation during left breast tangential radiotherapy (RT). This study compares the cardiac dose delivered by standard 3D conformal tangential RT (CRT) to that delivered by prospective-gating RT (PGRT) or 5-field intensity-modulated RT (IMRT). METHODS: Patients with early left breast cancer, referred for adjuvant RT to our institution, were enrolled in this study. For each patient, 2 simulation computed tomography scans were acquired: the first during free breathing, and the second on prospective gating during deep inspiration breath-hold. The scans were monitored by the Varian RPM™ respiratory gating system. For each patient, 3 treatment plans were performed: a 3D-CRT and an IMRT plan, each based on the free-breathing scan, and a PGRT plan, based on the deep inspiration breath-hold scan. Dose-volume histograms were compared by means of the Friedman test. RESULTS: The median mean heart dose was 3 Gy (range 0.9-7.3 Gy) in the CRT plans, 1.9 Gy (range 0.5-3.6 Gy) in the PGRT plans, and 4.5 Gy (range 1.1-10.5 Gy) in the IMRT plans (p = 0.001). The mean heart V25 was 1.2% (range 0%-9.7%), 0% (range 0%-2.0%), and 0.2% (range 0%-7.3%) for CRT, PGRT, and IMRT plans, respectively (p<0.001). CONCLUSIONS: Prospective-gating RT to the left breast offered the best protection of heart and lung, as well as a lower irradiation of the contralateral breast, compared to CRT or IMRT.


Subject(s)
Breast Neoplasms/radiotherapy , Heart/radiation effects , Radiotherapy, Conformal/adverse effects , Respiration , Adult , Aged , Breast Neoplasms/surgery , Breath Holding , Female , Humans , Inhalation , Middle Aged , Radiotherapy Dosage , Radiotherapy, Adjuvant/adverse effects , Radiotherapy, Adjuvant/methods , Radiotherapy, Conformal/methods , Radiotherapy, Intensity-Modulated/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...