1.
Article in English | MEDLINE | ID: mdl-34310299

ABSTRACT

We present a case report that shows an abscopal effect in the context of a safety and efficacy clinical trial for histotripsy as ablation technique in liver tumors. The abscopal effect appears in the form of reduction in the volume of nontreated tumor lesions in the same organ, as well as sustained reduction of tumor marker [carcinoembryonic antigen (CEA)] that extends weeks away of the procedure. Histotripsy is a novel noninvasive, nonthermal, and nonionizing precise ablation technique for tissue destruction guided by ultrasonography. We discuss the feasibility of this technique compared with other focal therapies and its possibilities as immune system enhancer.


Subject(s)
Ablation Techniques , High-Intensity Focused Ultrasound Ablation , Liver Neoplasms , Humans , Liver Neoplasms/diagnostic imaging , Ultrasonography
2.
Article in English | MEDLINE | ID: mdl-33856989

ABSTRACT

Histotripsy is a novel noninvasive nonthermal, nonionizing, and precise treatment technique for tissue destruction. Contrast-enhanced ultrasound (CEUS) improves the detection, characterization, and follow-up of hepatic lesions because it depicts accurately the vascular perfusion of both normal hepatic tissue and hepatic tumors. We present the spectrum of imaging findings of CEUS after histotripsy treatment of hepatic tumors. CEUS provides real-time information, a close approximation to the dimension of the lesion, and a clear definition of its margins. Hepatic tumors detected by ultrasound can be potentially treated using B-mode ultrasound-guided histotripsy and characterized and monitored with CEUS. CEUS has shown to be very useful after tissue treatment to monitor and assess the evolution of the treated zone. Histotripsy treated zones are practically isoechogenic and slightly heterogeneous, and their limits are difficult to establish using standard B-mode ultrasound. The use of CEUS after histotripsy showing uptake of contrast protruding into the treated zone is clinically relevant to identify residual tumors and establish the most appropriate management strategy avoiding unnecessary treatments. We here describe CEUS findings after histotripsy for hepatic tumors.


Subject(s)
Contrast Media , Liver Neoplasms , Humans , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/therapy , Ultrasonography
3.
J Neurosurg ; : 1-8, 2018 10 01.
Article in English | MEDLINE | ID: mdl-30485186

ABSTRACT

OBJECTIVE: Histotripsy is an ultrasound-based treatment modality relying on the generation of targeted cavitation bubble clouds, which mechanically fractionate tissue. The purpose of the current study was to investigate the in vivo feasibility, including dosage requirements and safety, of generating well-confined destructive lesions within the porcine brain utilizing histotripsy technology. METHODS: Following a craniectomy to open an acoustic window to the brain, histotripsy pulses were delivered to generate lesions in the porcine cortex. Large lesions with a major dimension of up to 1 cm were generated to demonstrate the efficacy of histotripsy lesioning in the brain. Gyrus-confined lesions were generated at different applied dosages and under ultrasound imaging guidance to ensure that they were accurately targeted and contained within individual gyri. Clinical evaluation as well as MRI and histological outcomes were assessed in the acute (≤ 6 hours) and subacute (≤ 72 hours) phases of recovery. RESULTS: Histotripsy was able to generate lesions with a major dimension of up to 1 cm in the cortex. Histotripsy lesions were seen to be well demarcated with sharp boundaries between treated and untreated tissues, with histological evidence of injuries extending ≤ 200 µm from their boundaries in all cases. In animals with lesions confined to the gyrus, no major hemorrhage or other complications resulting from treatment were observed. At 72 hours, MRI revealed minimal to no edema and no radiographic evidence of inflammatory changes in the perilesional area. Histological evaluation revealed the histotripsy lesions to be similar to subacute infarcts. CONCLUSIONS: Histotripsy can be used to generate sharply defined lesions of arbitrary shapes and sizes in the swine cortex. Lesions confined to within the gyri did not lead to significant hemorrhage or edema responses at the treatment site in the acute or subacute time intervals.

4.
J Ultrasound Med ; 31(11): 1795-802, 2012 Nov.
Article in English | MEDLINE | ID: mdl-23091251

ABSTRACT

We have developed a blood flow measurement system using Doppler ultrasound flow sensors fabricated of thin and flexible piezoelectric-polymer films. These flow sensors can be wrapped around a blood vessel and accurately measure flow. The innovation that makes this flow sensor possible is the diffraction-grating transducer. A conventional transducer produces a sound beam perpendicular to its face; therefore, when placed on the wall of a blood vessel, the Doppler shift in the backscattered ultrasound from blood theoretically would be 0. The diffraction-grating transducer produces a beam at a known angle to its face; therefore, backscattered ultrasound from the vessel will contain a Doppler signal. Flow sensors were fabricated by spin coating a poly(vinylidene fluoride-trifluoroethylene) copolymer film onto a flexible substrate with patterned gold electrodes. Custom-designed battery-operated continuous wave Doppler electronics along with a laptop computer completed the system. A prototype flow sensor was evaluated experimentally by measuring blood flow in a flow phantom and the infrarenal aorta of an adult New Zealand White rabbit. The flow phantom experiment demonstrated that the error in average velocity and volume blood flow was less than 6% for 30 measurements taken over a 2.5-hour period. The peak blood velocity through the rabbit infrarenal aorta measured by the flow sensor was 118 cm/s, within 1.7% of the measurement obtained using a duplex ultrasound system. The flow sensor and electronics operated continuously during the course of the 5-hour experiment after the incision on the animal was closed.


Subject(s)
Arteries/diagnostic imaging , Arteries/physiology , Postoperative Care/instrumentation , Prostheses and Implants , Refractometry/instrumentation , Transducers , Ultrasonography, Doppler/instrumentation , Animals , Blood Flow Velocity/physiology , Elastic Modulus , Equipment Design , Equipment Failure Analysis , Humans , Rabbits
5.
Article in English | MEDLINE | ID: mdl-22293745

ABSTRACT

A dual-curvature focused ultrasound phased-array transducer with a symmetric control has been developed for noninvasive ablative treatment of tumors. The 1.5-D array was constructed in-house and the electro-acoustic conversion efficiency was measured to be approximately 65%. In vitro experiments demonstrated that the array uses 256 independent elements to achieve 2-D wide-range high-intensity electronic focusing.


Subject(s)
High-Intensity Focused Ultrasound Ablation/instrumentation , Transducers , Animals , Computer Simulation , High-Intensity Focused Ultrasound Ablation/methods , Meat , Models, Biological , Neoplasms/therapy , Phantoms, Imaging , Swine
6.
Article in English | MEDLINE | ID: mdl-21989884

ABSTRACT

This paper describes the development of a high-frequency 256-element linear ultrasonic array utilizing an interdigitally bonded (IB) piezo-composite. Several IB composites were fabricated with different commercial and experimental piezoelectric ceramics and evaluated to determine a suitable formulation for use in high-frequency linear arrays. It was found that the fabricated fine-scale 2-2 IB composites outperformed 1-3 IB composites with identical pillar- and kerf-widths. This result was not expected and lead to the conclusion that dicing damage was likely the cause of the discrepancy. Ultimately, a 2-2 composite fabricated using a fine-grain piezoelectric ceramic was chosen for the array. The composite was manufactured using one IB operation in the azimuth direction to produce approximately 19-µm-wide pillars separated by 6-µm-wide kerfs. The array had a 50 µm (one wavelength in water) azimuth pitch, two matching layers, and 2 mm elevation length focused to 7.3 mm using a polymethylpentene (TPX) lens. The measured pulse-echo center frequency for a representative array element was 28 MHz and -6-dB bandwidth was 61%. The measured single-element transmit -6-dB directivity was estimated to be 50°. The measured insertion loss was 19 dB after compensating for the effects of attenuation and diffraction in the water bath. A fine-wire phantom was used to assess the lateral and axial resolution of the array when paired with a prototype system utilizing a 64-channel analog beamformer. The -6-dB lateral and axial resolutions were estimated to be 125 and 68 µm, respectively. An anechoic cyst phantom was also imaged to determine the minimum detectable spherical inclusion, and thus the 3-D resolution of the array and beamformer. The minimum anechoic cyst detected was approximately 300 µm in diameter.


Subject(s)
Ultrasonography/instrumentation , Animals , Cattle , Cysts/diagnostic imaging , Equipment Design , Eye/diagnostic imaging , Models, Biological , Phantoms, Imaging , Transducers , Ultrasonography/methods
7.
Biomed Opt Express ; 2(8): 2288-98, 2011 Aug 01.
Article in English | MEDLINE | ID: mdl-21833365

ABSTRACT

Detection of atherosclerotic plaque vulnerability has critical clinical implications for avoiding sudden death in patients with high risk of plaque rupture. We report on multimodality imaging of ex-vivo human carotid plaque samples using a system that integrates fluorescence lifetime imaging (FLIM), ultrasonic backscatter microscopy (UBM), and photoacoustic imaging (PAI). Biochemical composition is differentiated with a high temporal resolution and sensitivity at the surface of the plaque by the FLIM subsystem. 3D microanatomy of the whole plaque is reconstructed by the UBM. Functional imaging associated with optical absorption contrast is evaluated from the PAI component. Simultaneous recordings of the optical, ultrasonic, and photoacoustic data present a wealth of complementary information concerning the plaque composition, structure, and function that are related to plaque vulnerability. This approach is expected to improve our ability to study atherosclerotic plaques. The multimodal system presented here can be translated into a catheter based intraluminal system for future clinical studies.

8.
Ultrasonics ; 51(8): 953-9, 2011 Dec.
Article in English | MEDLINE | ID: mdl-21684568

ABSTRACT

In order to improve the lateral resolution and extend the field of view of a previously reported 48 element 30 MHz ultrasound linear array and 16-channel digital imaging system, the development of a 256 element 30 MHz linear array and an ultrasound imaging system with increased channel count has been undertaken. This paper reports the design and testing of a 64 channel digital imaging system which consists of an analog front-end pulser/receiver, 64 channels of Time-Gain Compensation (TGC), 64 channels of high-speed digitizer as well as a beamformer. A Personal Computer (PC) is used as the user interface to display real-time images. This system is designed as a platform for the purpose of testing the performance of high frequency linear arrays that have been developed in house. Therefore conventional approaches were taken it its implementation. Flexibility and ease of use are of primary concern whereas consideration of cost-effectiveness and novelty in design are only secondary. Even so, there are many issues at higher frequencies but do not exist at lower frequencies need to be solved. The system provides 64 channels of excitation pulsers while receiving simultaneously at a 20-120 MHz sampling rate to 12-bits. The digitized data from all channels are first fed through Field Programmable Gate Arrays (FPGAs), and then stored in memories. These raw data are accessed by the beamforming processor to re-build the image or to be downloaded to the PC for further processing. The beamformer that applies delays to the echoes of each channel is implemented with the strategy that combines coarse (8.3 ns) and fine delays (2 ns). The coarse delays are integer multiples of the sampling clock rate and are achieved by controlling the write enable pin of the First-In-First-Out (FIFO) memory to obtain valid beamforming data. The fine delays are accomplished with interpolation filters. This system is capable of achieving a maximum frame rate of 50 frames per second. Wire phantom images acquired with this system show a spatial resolution of 146 µm (lateral) and 54 µm (axial). Images with excised rabbit and pig eyeball as well as mouse embryo were also acquired to demonstrate its imaging capability.


Subject(s)
Ultrasonography/instrumentation , Animals , Embryo, Mammalian/diagnostic imaging , Equipment Design , Equipment Failure Analysis , Eye/diagnostic imaging , Image Enhancement/instrumentation , Mice , Microcomputers , Phantoms, Imaging , Rabbits , Swine , Transducers , User-Computer Interface
9.
Ultrasound Med Biol ; 37(3): 484-92, 2011 Mar.
Article in English | MEDLINE | ID: mdl-21276653

ABSTRACT

Building photoacoustic imaging (PAI) systems by using stand-alone ultrasound (US) units makes it convenient to take advantage of the state-of-the-art ultrasonic technologies. However, the sometimes limited receiving sensitivity and the comparatively narrow bandwidth of commercial US probes may not be sufficient to acquire high quality photoacoustic images. In this work, a high-speed PAI system has been developed using a commercial US unit and a custom built 128-element piezoelectric-polymer array (PPA) probe using a P(VDF-TrFE) film and flexible circuit to define the elements. Since the US unit supports simultaneous signal acquisition from 64 parallel receive channels, PAI data for synthetic image formation from a 64- or 128-element array aperture can be acquired after a single or dual laser firing, respectively. Therefore, two-dimensional (2-D) B-scan imaging can be achieved with a maximum frame rate up to 10 Hz, limited only by the laser repetition rate. The uniquely properties of P(VDF-TrFE) facilitated a wide -6 dB receiving bandwidth of over 120% for the array. A specially designed 128-channel preamplifier board made the connection between the array and the system cable, which not only enabled element electrical impedance matching but also further elevated the signal-to-noise ratio (SNR) to further enhance the detection of weak photoacoustic signals. Through the experiments on phantoms and rabbit ears, the good performance of this PAI system was demonstrated.


Subject(s)
Elasticity Imaging Techniques/instrumentation , Image Enhancement/instrumentation , Transducers , Animals , Equipment Design , Equipment Failure Analysis , Phantoms, Imaging , Rabbits , Reproducibility of Results , Sensitivity and Specificity
10.
Article in English | MEDLINE | ID: mdl-21244988

ABSTRACT

This paper reports the design, fabrication, and characterization of a 1-3 composite annular-array transducer. An interdigital bonded (IB) 1-3 composite was prepared using two IB operations on a fine-grain piezoelectric ceramic. The final composite had 19-µm-wide posts separated by 6-µm-wide polymer kerfs. A novel method to remove metal electrodes from polymer portions of the 1-3 composite was established to eliminate the need for patterning and aligning the electrode on the composite to the electrodes on a flexible circuit. Unloaded epoxy was used for both the matching and backing layers and a flexible circuit was used for interconnect. A prototype array was successfully fabricated and tested. The results were in reasonable agreement with those predicted by a circuit-analogous model. The average center frequency estimated from the measured pulse-echo responses of array elements was 33.5 MHz and the -6-dB fractional bandwidth was 57%. The average insertion loss recorded was 14.3 dB, and the maximum crosstalk between the nearest-neighbor elements was less than -37 dB. Images of a wire phantom and excised porcine eye were obtained to show the capabilities of the array for high-frequency ultrasound imaging.


Subject(s)
Lead/chemistry , Titanium/chemistry , Transducers , Ultrasonography/instrumentation , Zirconium/chemistry , Animals , Ceramics/chemistry , Electric Impedance , Equipment Design , Eye/diagnostic imaging , Phantoms, Imaging , Swine
11.
Ultrasound Med Biol ; 36(11): 1836-48, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20870346

ABSTRACT

In noninvasive high-intensity focused ultrasound (HIFU) treatment, formation of a large tissue lesion per sonication is desirable for reducing the overall treatment time. The goal of this study is to show the feasibility of enlarging tissue lesion size with a dual-focus therapeutic ultrasound transducer (DFTUT) by increasing the depth-of-focus (DOF). The proposed transducer consists of a disc- and an annular-type element of different radii of curvatures to produce two focal zones. To increase focal depth and to maintain uniform beamwidth of the elongated DOF, each element transmits ultrasound of a different center frequency: the inner element at a higher frequency for near field focusing and the outer element at a lower frequency for far field focusing. By activating two elements at the same time with a single transmitter capable of generating a dual-frequency mixed signal, the overall DOF of the proposed transducer may be extended considerably. A prototype transducer composed of a 4.1 MHz inner element and a 2.7 MHz outer element was fabricated to obtain preliminary experimental results. The feasibility the proposed technique was demonstrated through sound field, temperature and thermal dose simulations. The performance of the prototype transducer was verified by hydrophone measurements and tissue ablation experiments on a beef liver specimen. When several factors affecting the length and the uniformity of elongated DOF of the DFTUT are optimized, the proposed therapeutic ultrasound transducer design may increase the size of ablated tissues in the axial direction and, thus, decreasing the treatment time for a large volume of malignant tissues especially deep-seated targets.


Subject(s)
Neoplasms/therapy , Transducers , Ultrasonic Therapy/instrumentation , Equipment Design , Feasibility Studies , Hot Temperature , Humans
12.
Article in English | MEDLINE | ID: mdl-20639149

ABSTRACT

High-frequency (HF) ultrasound imaging has been shown to be useful for non-invasively imaging anatomical structures of the eye and small animals in biological and pharmaceutical research, achieving superior spatial resolution. Cardiovascular research utilizing mice requires not only realtime B-scan imaging, but also ultrasound Doppler to evaluate both anatomy and blood flow of the mouse heart. This paper reports the development of an HF ultrasound duplex imaging system capable of both B-mode imaging and Doppler flow measurements, using a 64-element linear array. The system included an HF pulsed-wave Doppler module, a 32-channel HF B-mode imaging module, a PC with a 200 MS/s 14-bit A/D card, and real-time LabView software. A 50 dB SNR and a depth of penetration of larger than 12 mm were achieved using a 35-MHz linear array with 50 µm pitch. The two-way beam widths were determined to be 165 to 260 µm and the clutter-energy-to-total-energy ratio (CTR) were 9.1 to 12 dB when the array was electronically focused at different focal points at depths from 4.8 to 9.6 mm. The system is capable of acquiring real-time B-mode images at a rate greater than 400 frames per second (fps) for a 4.8 x 13 mm field of view, using a 30- MHz 64-element linear array with 100 µm pitch. Sample in vivo cardiac high frame rate images and duplex images of mouse hearts are shown to assess its current imaging capability and performance for small animals.


Subject(s)
Image Processing, Computer-Assisted/methods , Signal Processing, Computer-Assisted , Ultrasonography, Doppler, Duplex/instrumentation , Ultrasonography, Doppler, Duplex/methods , Animals , Echocardiography, Doppler , Equipment Design , Heart/anatomy & histology , Mice , Mice, Inbred BALB C
13.
Ultrasound Med Biol ; 36(5): 733-42, 2010 May.
Article in English | MEDLINE | ID: mdl-20420969

ABSTRACT

Optical coherence tomography (OCT) and ultrasound (US) are methods widely used for diagnostic imaging of the eye. These techniques detect discontinuities in optical refractive index and acoustic impedance, respectively. Because these both relate to variations in tissue density or composition, OCT and US images share a qualitatively similar appearance. In photoacoustic imaging (PAI), short light pulses are directed at tissues, pressure is generated due to a rapid energy deposition in the tissue volume and thermoelastic expansion results in generation of broadband US. PAI thus depicts optical absorption, which is independent of the tissue characteristics imaged by OCT or US. Our aim was to demonstrate the application of PAI in ocular tissues and to do so with lateral resolution comparable to OCT. We developed two PAI assemblies, both of which used single-element US transducers and lasers sharing a common focus. The first assembly had optical and 35-MHz US axes offset by a 30 degrees angle. The second assembly consisted of a 20-MHz ring transducer with a coaxial optics. The laser emitted 5-ns pulses at either 532 nm or 1064 nm, with spot sizes at the focus of 35 microm for the angled probe and 20 microm for the coaxial probe. We compared lateral resolution by scanning 12.5 microm diameter wire targets with pulse/echo US and PAI at each wavelength. We then imaged the anterior segment in whole ex vivo pig eyes and the choroid and ciliary body region in sectioned eyes. PAI data obtained at 1064 nm in the near infrared had higher penetration but reduced signal amplitude compared to that obtained using the 532 nm green wavelength. Images were obtained of the iris, choroid and ciliary processes. The zonules and anterior cornea and lens surfaces were seen at 532 nm. Because the laser spot size was significantly smaller than the US beamwidth at the focus, PAI images had superior resolution than those obtained using conventional US.


Subject(s)
Elasticity Imaging Techniques/instrumentation , Eye/diagnostic imaging , Ophthalmoscopes , Transducers , Animals , Equipment Design , Equipment Failure Analysis , In Vitro Techniques , Reproducibility of Results , Sensitivity and Specificity , Swine
14.
Article in English | MEDLINE | ID: mdl-20040413

ABSTRACT

High-frequency PIN-PMN-PT single crystal ultrasound transducers at center frequencies of 35 MHz and 60 MHz were successfully fabricated using lead indium niobate-lead magnesium niobate-lead titanate (0.23PIN- 0.5PMN-0.27PT) single crystal. The new PIN-PMN-PT single crystal has higher coercivity (6.0 kV/cm) and higher Curie temperature (160 degrees C) than PMN-PT crystal. Experimental results showed that the PIN-PMN-PT transducers have similar performance but better thermal stability compared with the PMN-PT transducers.


Subject(s)
Ceramics , Transducers , Ultrasonography/instrumentation , Computer-Aided Design , Crystallization/methods , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Sensitivity and Specificity
15.
Article in English | MEDLINE | ID: mdl-19963529

ABSTRACT

Our Bioengineering Research Partnership grant, -High Frequency Ultrasound Arrays for Cardiac Imaging", including the individuals cited at the end of this paper - Douglas N. Stephens (UC Davis), Matthew O'Donnell (UW Seattle), Kai Thomenius (GE Global Research), Aaron M. Dentinger (GE Global Research), Douglas Wildes (GE Global Research), Peter Chen (St. Jude Medical), K. Kirk Shung (University of Southern California), Jonathan M. Cannata (University of Southern California), Butrus (Pierre) T. Khuri-Yakub (Stanford University), Omer Oralkan (Stanford University), Aman Mahajan (UCLA School of Medicine), Kalyanam Shivkumar (UCLA School of Medicine) and David J. Sahn (Oregon Health & Science University) - is in its sixth year of NIH funding, having proposed to develop a family of high frequency miniaturized forward and side-looking ultrasound imaging devices equipped with electrophysiology mapping and localization sensors and eventually to include a family of capactive micromachined ultrasonic transducer (cMUT) devices - a forward-looking cMUT MicroLinear array and a ring array capable of 3-dimensional imaging and a 5Fr lumen large enough to admit an electrode and ablation devices.


Subject(s)
Atrial Fibrillation/diagnostic imaging , Cardiac Catheterization/methods , Ultrasonography, Interventional/classification , Adult , Aged , Animals , Atrial Fibrillation/epidemiology , Body Surface Potential Mapping/instrumentation , Cardiac Catheterization/instrumentation , Electrophysiologic Techniques, Cardiac , Equipment Design , Heart Atria/diagnostic imaging , Humans , Middle Aged , Models, Animal , Pulmonary Veins/diagnostic imaging , Swine , Ultrasonography, Interventional/instrumentation , United States/epidemiology
16.
Rev Sci Instrum ; 80(6): 065104, 2009 Jun.
Article in English | MEDLINE | ID: mdl-19566223

ABSTRACT

We report a tissue diagnostic system which combines two complementary techniques of time-resolved laser-induced fluorescence spectroscopy (TR-LIFS) and ultrasonic backscatter microscopy (UBM). TR-LIFS evaluates the biochemical composition of tissue, while UBM provides tissue microanatomy and enables localization of the region of diagnostic interest. The TR-LIFS component consists of an optical fiber-based time-domain apparatus including a spectrometer, gated multichannel plate photomultiplier, and fast digitizer. It records the fluorescence with high sensitivity (nM concentration range) and time resolution as low as 300 ps. The UBM system consists of a transducer, pulser, receiving circuit, and positioning stage. The transducer used here is 45 MHz, unfocused, with axial and lateral resolutions 38 and 200 microm. Validation of the hybrid system and ultrasonic and spectroscopic data coregistration were conducted both in vitro (tissue phantom) and ex vivo (atherosclerotic tissue specimens of human aorta). Standard histopathological analysis of tissue samples was used to validate the UBM-TRLIFS data. Current results have demonstrated that spatially correlated UBM and TR-LIFS data provide complementary characterization of both morphology (necrotic core and calcium deposits) and biochemistry (collagen, elastin, and lipid features) of the atherosclerotic plaques at the same location. Thus, a combination of fluorescence spectroscopy with ultrasound imaging would allow for better identification of features associated with tissue pathologies. Current design and performance of the hybrid system suggests potential applications in clinical diagnosis of atherosclerotic plaque.


Subject(s)
Microscopy, Acoustic/instrumentation , Microscopy, Acoustic/methods , Spectrometry, Fluorescence , Ultrasonics , Aorta/diagnostic imaging , Aorta/pathology , Atherosclerosis/diagnostic imaging , Atherosclerosis/pathology , Calibration , Collagen Type I/chemistry , Elastin/chemistry , Equipment Design , Humans , Lasers , Phantoms, Imaging , Spectrometry, Fluorescence/instrumentation , Spectrometry, Fluorescence/methods , Time Factors
17.
Appl Phys Lett ; 94(3): 33902, 2009 Jan 19.
Article in English | MEDLINE | ID: mdl-19529786

ABSTRACT

We report a photoacoustic imager that utilizes a focused laser beam in combination with a 20 MHz ultrasound focusing transducer to obtain micron-resolution tissue images over a long working distance. The imager is based on a ring transducer that combines ultrasonic and laser beams collinearly and confocally in a monolithic element. The combination of focused laser beam and short pulse irradiation led to significant improvement in lateral and axial resolutions compared to the pulse-echo ultrasonic imaging technique or photoacoustic imaging with an unfocused laser. Potential applications include clinical examination of the eye and characterization of thin and superficial tissues.

18.
Article in English | MEDLINE | ID: mdl-18599429

ABSTRACT

A high-frequency angled needle ultrasound transducer with an aperture size of 0.4 x 0.56 mm2 was fabricated using a lead zinc niobate-lead titanate (PZN- 7%PT) single crystal as the active piezoelectric material. The single crystal was bonded to a conductive silver particle matching layer and a conductive epoxy backing material through direct contact curing. A parylene outer matching layer was formed by vapor deposition. Angled needle probe configuration was achieved by dicing at 45 degrees to the single crystal poling direction to satisfy a clinical request for blood flow measurement in the posterior portion of the eye. The electrical impedance magnitude and phase of the transducer were 42 Omega and -63 degrees , respectively. The measured center frequency and the fractional bandwidth at -6 dB were 43 MHz and 45%, respectively. The two-way insertion loss was approximately 17 dB. Wire phantom imaging using fabricated PZN-7%PT single crystal transducers was obtained and spatial resolutions were assessed.


Subject(s)
Lead/chemistry , Lead/radiation effects , Needles , Niobium/chemistry , Niobium/radiation effects , Titanium/chemistry , Titanium/radiation effects , Transducers , Ultrasonography/methods , Zinc/chemistry , Zinc/radiation effects , Computer-Aided Design , Equipment Design , Equipment Failure Analysis
19.
Article in English | MEDLINE | ID: mdl-19126492

ABSTRACT

Concentric annular type dual element transducers for second harmonic imaging at 20 MHz / 40 MHz were designed and fabricated to improve spatial resolution and depth of penetration for ophthalmic imaging applications. The outer ring element was designed to transmit the 20 MHz signal and the inner circular element was designed to receive the 40 MHz second harmonic signal. Lithium niobate (LiNbO(3)), with its low dielectric constant, was used as the piezoelectric material to achieve good electrical impedance matching. Double matching layers and conductive backing were used and optimized by KLM modeling to achieve high sensitivity and wide bandwidth for harmonic imaging and superior time-domain characteristics. Prototype transducers were fabricated and evaluated quantitatively and clinically. The average measured center frequency for the transmit ring element was 21 MHz and the one-way --3 dB bandwidth was greater than 50%. The 40 MHz receive element functioned at 31 MHz center frequency with acceptable bandwidth to receive attenuated and frequency downshifted harmonic signal. The lateral beam profile for the 20 MHz ring elements at the focus matched the Field II simulated results well, and the effect of outer ring diameter was also examined. Images of a posterior segment of an excised pig eye and a choroidal nevus of human eye were obtained both for single element and dual element transducers and compared to demonstrate the advantages of dual element harmonic imaging.


Subject(s)
Electrochemistry/instrumentation , Transducers , Ultrasonography/instrumentation , Ultrasonography/methods , Animals , Electric Impedance , Equipment Design , Equipment Failure Analysis , Eye/diagnostic imaging , Humans , Niobium/chemistry , Oxides/chemistry , Reproducibility of Results , Sensitivity and Specificity , Swine
20.
Proc IEEE Ultrason Symp ; : 570-573, 2008.
Article in English | MEDLINE | ID: mdl-21894259

ABSTRACT

We report the development and validate a multi-modal tissue diagnostic technology, which combines three complementary techniques into one system including ultrasound backscatter microscopy (UBM), photoacoustic imaging (PAI), and time-resolved laser-induced fluorescence spectroscopy (TR-LIFS). UBM enables the reconstruction of the tissue microanatomy. PAI maps the optical absorption heterogeneity of the tissue associated with structure information and has the potential to provide functional imaging of the tissue. Examination of the UBM and PAI images allows for localization of regions of interest for TR-LIFS evaluation of the tissue composition. The hybrid probe consists of a single element ring transducer with concentric fiber optics for multi-modal data acquisition. Validation and characterization of the multi-modal system and ultrasonic, photoacoustic, and spectroscopic data coregistration were conducted in a physical phantom with properties of ultrasound scattering, optical absorption, and fluorescence. The UBM system with the 41 MHz ring transducer can reach the axial and lateral resolution of 30 and 65 µm, respectively. The PAI system with 532 nm excitation light from a Nd:YAG laser shows great contrast for the distribution of optical absorbers. The TR-LIFS system records the fluorescence decay with the time resolution of ~300 ps and a high sensitivity of nM concentration range. Biological phantom constructed with different types of tissues (tendon and fat) was used to demonstrate the complementary information provided by the three modalities. Fluorescence spectra and lifetimes were compared to differentiate chemical composition of tissues at the regions of interest determined by the coregistered high resolution UBM and PAI image. Current results demonstrate that the fusion of these techniques enables sequentially detection of functional, morphological, and compositional features of biological tissue, suggesting potential applications in diagnosis of tumors and atherosclerotic plaques.