Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
1.
J Control Release ; 365: 491-506, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38030083

ABSTRACT

Nanoparticle (NP) formulations are inherently polydisperse making their structural characterization and justification of specifications complex. It is essential, however, to gain an understanding of the physico-chemical properties that drive performance in vivo. To elucidate these properties, drug-containing poly(lactic acid) (PLA)-poly(ethylene glycol) (PEG) block polymeric NP formulations (or PNPs) were sub-divided into discrete size fractions and analyzed using a combination of advanced techniques, namely cryogenic transmission electron microscopy, small-angle neutron and X-ray scattering, nuclear magnetic resonance, and hard-energy X-ray photoelectron spectroscopy. Together, these techniques revealed a uniquely detailed picture of PNP size, surface structure, internal molecular architecture and the preferred site(s) of incorporation of the hydrophobic drug, AZD5991, properties which cannot be accessed via conventional characterization methodologies. Within the PNP size distribution, it was shown that the smallest PNPs contained significantly less drug than their larger sized counterparts, reducing overall drug loading, while PNP molecular architecture was critical in understanding the nature of in vitro drug release. The effect of PNP size and structure on drug biodistribution was determined by administrating selected PNP size fractions to mice, with the smaller sized NP fractions increasing the total drug-plasma concentration area under the curve and reducing drug concentrations in liver and spleen, due to greater avoidance of the reticuloendothelial system. In contrast, administration of unfractionated PNPs, containing a large population of NPs with extremely low drug load, did not significantly impact the drug's pharmacokinetic behavior - a significant result for nanomedicine development where a uniform formulation is usually an important driver. We also demonstrate how, in this study, it is not practicable to validate the bioanalytical methodology for drug released in vivo due to the NP formulation properties, a process which is applicable for most small molecule-releasing nanomedicines. In conclusion, this work details a strategy for determining the effect of formulation variability on in vivo performance, thereby informing the translation of PNPs, and other NPs, from the laboratory to the clinic.


Subject(s)
Nanoparticles , Polyethylene Glycols , Mice , Animals , Polyethylene Glycols/chemistry , Tissue Distribution , Polymers/chemistry , Polyesters/chemistry , Nanoparticles/chemistry , Particle Size , Drug Carriers/chemistry
2.
Anal Chem ; 95(40): 15078-15085, 2023 Oct 10.
Article in English | MEDLINE | ID: mdl-37715701

ABSTRACT

Quantitative analysis of binary mixtures of tris(2-phenylpyridinato)iridium(III) (Ir(ppy)3) and tris(8-hydroxyquinolinato)aluminum (Alq3) by using an artificial neural network (ANN) system to mass spectra was attempted based on the results of a VAMAS (Versailles Project on Advanced Materials and Standards) interlaboratory study (TW2 A31) to evaluate matrix-effect correction and to investigate interface determination. Monolayers of binary mixtures having different Ir(ppy)3 ratios (0, 0.25, 0.50, 0.75, and 1.00), and the multilayers containing these mixtures and pure samples were measured using time-of-flight secondary ion mass spectrometry (ToF-SIMS) with different primary ion beams, OrbiSIMS (SIMS with both Orbitrap and ToF mass spectrometers), laser desorption ionization (LDI), desorption/ionization induced by neutral clusters (DINeC), and X-ray photoelectron spectroscopy (XPS). The mass spectra were analyzed using a simple ANN with one hidden layer. The Ir(ppy)3 ratios of the unknown samples and the interfaces of the multilayers were predicted using the simple ANN system, even though the mass spectra of binary mixtures exhibited matrix effects. The Ir(ppy)3 ratios at the interfaces indicated by the simple ANN were consistent with the XPS results and the ToF-SIMS depth profiles. The simple ANN system not only provided quantitative information on unknown samples, but also indicated important mass peaks related to each molecule in the samples without a priori information. The important mass peaks indicated by the simple ANN depended on the ionization process. The simple ANN results of the spectra sets obtained by a softer ionization method, such as LDI and DINeC, suggested large ions such as trimers. From the first step of the investigation to build an ANN model for evaluating mixture samples influenced by matrix effects, it was indicated that the simple ANN method is useful for obtaining candidate mass peaks for identification and for assuming mixture conditions that are helpful for further analysis.

3.
J Phys Chem A ; 127(39): 8220-8227, 2023 Oct 05.
Article in English | MEDLINE | ID: mdl-37733882

ABSTRACT

Nanoparticles used for medical applications commonly possess coatings or surface functionalities intended to provide specific behavior in vivo, for example, the use of PEG to provide stealth properties. Direct, quantitative measurement of the surface chemistry and composition of such systems in a hydrated environment has thus far not been demonstrated, yet such measurements are of great importance for the development of nanomedicine systems. Here we demonstrate the first use of cryo-XPS for the measurement of two PEG-functionalized nanomedicines: a polymeric drug delivery system and a lipid nanoparticle mRNA carrier. The observed differences between cryo-XPS and standard XPS measurements indicate the potential of cryo-XPS for providing quantitative measurements of such nanoparticle systems in hydrated conditions.


Subject(s)
Nanomedicine , Nanoparticles , Polyethylene Glycols/chemistry , Drug Delivery Systems , Nanoparticles/chemistry , Polymers
4.
Acta Orthop ; 94: 289-294, 2023 06 16.
Article in English | MEDLINE | ID: mdl-37345369

ABSTRACT

BACKGROUND AND PURPOSE: Physeal fractures represent 15-20% of all pediatric fractures and may lead to premature physeal closure (PPC). The aim of our study was to determine the incidence rates of physeal fractures in the lower limb and the proportion of PPC that lead to limb length discrepancy (LLD), and/or angular deformity (AD). PATIENTS AND METHODS: This retrospective study included 236 consecutive children with physeal fracture in the tibia, distal femur, or distal fibula. We estimated incidence rates and reviewed medical records and radiographs to obtain information regarding the development of PPC leading to LLD and AD. Of the 236 children, 100 had planned growth control or were referred for growth control due to symptoms of PPC. RESULTS: The total incidence rate was 35 (95% CI 30-39) per 100,000 person-years, with 1.2 (CI 0.5-23) for distal femur, 5.7 (CI 3.1-7.8) for proximal tibia, 14 (CI 11-17) for distal tibia, and 14 (CI 11-17) for distal fibula. The overall prevalence of PPC was 9.7% (CI 6.3-14), while the prevalence was 38% (CI 8.5-76) for distal femur, 15% (CI 5.9-31) for proximal tibia, 14% (CI 7.4--22) for distal tibia, and 1.1% (CI 0.3--59) for distal fibula. We found a significant higher hazard of PPC in fractures with ≥ 3 mm displacement (hazard ratio: 12, CI 1.5-97). CONCLUSION: 10% of children with physeal fractures developed PPC that led to LLD or AD. The highest hazard ratio was in children who had an initial fracture displacement. This study highlights the importance of routine and uniform growth evaluation after a physeal fracture.


Subject(s)
Fractures, Multiple , Tibial Fractures , Humans , Child , Incidence , Cohort Studies , Retrospective Studies , Tibial Fractures/diagnostic imaging , Tibial Fractures/epidemiology , Growth Plate/diagnostic imaging , Lower Extremity
5.
Anal Chim Acta ; 1262: 341234, 2023 Jun 29.
Article in English | MEDLINE | ID: mdl-37179055

ABSTRACT

The quantification of the drug associated to nanoparticle carriers, often expressed in terms of encapsulation efficiency, is a regulatory requirement. The establishment of independent methods to evaluate this parameter provides a means for measurement validation, which is critical in providing confidence in the methods and enabling the robust characterization of nanomedicines. Chromatography is traditionally used to measure drug encapsulation into nanoparticles. Here, we describe an additional independent strategy based on analytical centrifugation. The encapsulation of diclofenac into nanocarriers was quantified based on the mass difference between placebo (i.e. unloaded) and loaded nanoparticles. This difference was estimated using particle densities measured by differential centrifugal sedimentation (DCS) and size and concentration values measured by particle tracking analysis (PTA). The proposed strategy was applied to two types of formulations, namely poly(lactic-co-glycolic acid) (PLGA) nanoparticles and nanostructured lipid carriers, which were analysed by DCS operated in sedimentation and flotation modes, respectively. The results were compared to those from high performance liquid chromatography (HPLC) measurements. Additionally, X-ray photoelectron spectroscopy analysis was used to elucidate the surface chemical composition of the placebo and loaded nanoparticles. The proposed approach enables the monitoring of batch-to-batch consistency and the quantification of diclofenac association to PLGA nanoparticles from 0.7 ng to 5 ng of drug per 1 µg of PLGA, with good linear correlation between DCS and HPLC results (R2 = 0.975). Using the same approach, similar quantification in lipid nanocarriers was possible for a loading of diclofenac ≥1.1 ng per 1 µg of lipids, with results in agreement with the HPLC method (R2 = 0.971). Hence, the strategy proposed here expands the analytical tools available for evaluating nanoparticles encapsulation efficiency, being thus significant for increasing the robustness of drug-delivery nanocarriers characterization.


Subject(s)
Diclofenac , Nanoparticles , Polylactic Acid-Polyglycolic Acid Copolymer , Polyglycolic Acid/chemistry , Lactic Acid/chemistry , Nanoparticles/chemistry , Lipids , Particle Size , Drug Carriers/chemistry
6.
Ultrason Sonochem ; 89: 106141, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36067646

ABSTRACT

Control over the agglomeration state of manufactured particle systems for drug and oligonucleotide intracellular delivery is paramount to ensure reproducible and scalable therapeutic efficacy. Ultrasonication is a well-established mechanism for the deagglomeration of bulk powders in dispersion. Its use in manufacturing requires strict control of the uniformity and reproducibility of the cavitation field within the sample volume to minimise within-batch and batch-to-batch variability. In this work, we demonstrate the use of a reference cavitating vessel which provides stable and reproducible cavitation fields over litre-scale volumes to assist the controlled deagglomeration of a novel non-viral particle-based plasmid delivery system. The system is the Nuvec delivery platform, comprising polyethylenimine-coated spiky silica particles with diameters of âˆ¼ 200 nm. We evaluated the use of controlled cavitation at different input powers and stages of preparation, for example before and after plasmid loading. Plasmid loading was confirmed by X-ray photoelectron spectroscopy and gel electrophoresis. The latter was also used to assess plasmid integrity and the ability of the particles to protect plasmid from potential degradation caused by the deagglomeration process. We show the utility of laser diffraction and differential centrifugal sedimentation in quantifying the efficacy of product de-agglomeration in the microscale and nanoscale size range respectively. Transmission electron microscopy was used to assess potential damages to the silica particle structure due to the sonication process.


Subject(s)
Nanomedicine , Polyethyleneimine , DNA , Oligonucleotides , Particle Size , Polyethyleneimine/chemistry , Reproducibility of Results , Silicon Dioxide
7.
Anal Bioanal Chem ; 414(15): 4331-4345, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35471249

ABSTRACT

Core-shell nanoparticles have attracted much attention in recent years due to their unique properties and their increasing importance in many technological and consumer products. However, the chemistry of nanoparticles is still rarely investigated in comparison to their size and morphology. In this review, the possibilities, limits, and challenges of X-ray photoelectron spectroscopy (XPS) for obtaining more insights into the composition, thickness, and homogeneity of nanoparticle coatings are discussed with four examples: CdSe/CdS quantum dots with a thick coating and a small core; NaYF4-based upconverting nanoparticles with a large Yb-doped core and a thin Er-doped coating; and two types of polymer nanoparticles with a poly(tetrafluoroethylene) core with either a poly(methyl methacrylate) or polystyrene coating. Different approaches for calculating the thickness of the coating are presented, like a simple numerical modelling or a more complex simulation of the photoelectron peaks. Additionally, modelling of the XPS background for the investigation of coating is discussed. Furthermore, the new possibilities to measure with varying excitation energies or with hard-energy X-ray sources (hard-energy X-ray photoelectron spectroscopy) are described. A discussion about the sources of uncertainty for the determination of the thickness of the coating completes this review. Graphical abstract.


Subject(s)
Nanoparticles , Quantum Dots , Nanoparticles/chemistry , Photoelectron Spectroscopy , Polymers , Polystyrenes
8.
Environ Sci Process Impacts ; 24(5): 794-804, 2022 May 25.
Article in English | MEDLINE | ID: mdl-35466972

ABSTRACT

This study compared the surface properties and rising velocities of pristine and weathered plastic production pellets, to evaluate impacts of environmental conditions. Rising velocities were measured for 140 weathered pellets collected from a Spanish beach and compared with pristine low-density polyethylene, high-density polyethylene and polypropylene pellets. A subset of 49 weathered pellets were analysed by Fourier-transform infrared spectroscopy (FTIR), with all found to be polyethylene. Experimental rising velocities for the weathered pellets varied widely, from (2.36 ± 0.01) cm s-1 to (10.56 ± 0.26) cm s-1, with a mean value of (5.79 ± 0.06) cm s-1. Theoretical rising velocities were consistently higher than experimental velocities for all pellet types: on average 136% of experimental values for weathered pellets. This discrepancy was more distinct for less spherical pellets, which were often more weathered. Flatter pellets often oscillated as they rose, which explains at least some of this finding. Atomic force microscopy (AFM) analysis revealed that the roughness of the pristine and weathered pellets was (59 ± 11) nm, and (74 ± 26) nm respectively. X-ray photoelectron spectroscopy (XPS) analysis showed that the proportion of surface oxidised carbon species were 2.3% and 4.0% of the total carbon signal for a pristine and a weathered pellet, respectively; consistent with photochemical reactions changing the surface chemistry of weathered pellets. As determined by density column, weathered pellets had slightly lower experimental densities than pristine pellets. Overall, this study illustrates why it is important that modelling studies on the environmental fate and/or movements of microplastics validate or correct predictions using experimental data.

9.
Methods Mol Biol ; 2208: 203-224, 2021.
Article in English | MEDLINE | ID: mdl-32856265

ABSTRACT

X-ray photoelectron spectroscopy is a highly surface-sensitive analytical technique, capable of providing quantitative information on the chemical composition of materials within the top ∼10 nm of their surface. For samples consisting of distinct underlayer and overlayer materials, the thickness of the coating can also be determined if it falls within this ∼10 nm information depth, which is often the case for peptide layers. Such measurements are simple to perform for flat samples and can also be performed on nanoparticulate samples provided that either the core radius or total particle radius are known. Here, we describe a straightforward protocol for obtaining such measurements from peptide coatings on both flat surfaces and nanoparticles, including preparation of nanoparticle samples from suspension, data acquisition, and analysis.


Subject(s)
Peptides/chemistry , Photoelectron Spectroscopy/methods , Nanoparticles/chemistry , Surface Properties
10.
J Vac Sci Technol A ; 38(6): 063208, 2020 Dec.
Article in English | MEDLINE | ID: mdl-33281279

ABSTRACT

We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ∼3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ∼5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ∼4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. We also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration.

11.
Forensic Sci Int ; 302: 109895, 2019 Sep.
Article in English | MEDLINE | ID: mdl-31419594

ABSTRACT

A scent lineup is generally a procedure whereby a dog's alerting behavior is used to establish that the dog detects two scents, one from a crime scene and one from a suspect, as deriving from the same person. The aim of this article is to compare methodologies of using dogs in scent lineups as a means of identifying perpetrators of crimes. It is hoped that this comparative approach, looking at countries where the method is currently or has in the past been used, will help determine what issues should be addressed in order to assure that the scent lineup will have a future as a forensic technique. Participants from eleven countries-Belgium, The Czech Republic, Finland, France, Germany, Hungary, Lithuania, The Netherlands, Poland, Russia, and the U.S.-completed a survey questionnaire regarding key aspects of the scent lineup procedures used by the police in their countries. Although there was broad overlap on certain matters, such as the use of control and zero trials, collection of decoy scents from individuals of similar gender and race as the suspect, materials for holding scent, frequency of cleaning and changing stations, and use and timing of rewards, there were significant differences in the degree of blindness required, who calls an alert (handler or experimenter), and whether handlers can work with more than one dog. The gap between recommendations and results available from the scientific literature and procedures used in police practice was greater for some countries than others, even taking into account that some scientific methodologies might be expensive or impractical given agency resources. The authors make recommendations about how to go forward if scent lineups are to remain a valid forensic technique.


Subject(s)
Criminal Law , Dogs/physiology , Odorants , Smell/physiology , Animals , Europe , Russia , Surveys and Questionnaires , United States
12.
RSC Adv ; 8(48): 27276-27282, 2018 Jul 30.
Article in English | MEDLINE | ID: mdl-35539986

ABSTRACT

The response of nanoparticles to exposure to ambient conditions and especially oxidation is fundamental to the application of nanotechnology. Bimetallic platinum-titanium nanoparticles of selected mass, 30 kDa and 90 kDa, were produced using a magnetron sputtering gas condensation cluster source and deposited onto amorphous carbon TEM grids. The nanoparticles were analysed with a Cs-corrected Scanning Transmission Electron Microscope (STEM) in High Angle Annular Dark Field (HAADF) mode. It was observed that prior to full Ti oxidation, Pt atoms were dispersed within a Ti shell. However, after full oxidation by prolonged exposure to ambient conditions prior to STEM, the smaller size 30 kDa particles form a single Pt core and the larger size 90 kDa particles exhibit a multi-core structure. Electron beam annealing induced a single core morphology in the larger particles. First principles density functional theory (DFT) calculations were employed to calculate the lowest energy structure of the Pt-Ti nanoparticles with and without the presence of oxygen. It was demonstrated that, as the concentration of oxygen increases, the lowest energy structure changes from dispersed Pt to multiple Pt cores and finally a single Pt core, which is in good agreement with the experimental observations.

13.
J Phys Chem C Nanomater Interfaces ; 120(42): 24070-24079, 2016 Oct 27.
Article in English | MEDLINE | ID: mdl-27818719

ABSTRACT

We report the results of a VAMAS (Versailles Project on Advanced Materials and Standards) inter-laboratory study on the measurement of the shell thickness and chemistry of nanoparticle coatings. Peptide-coated gold particles were supplied to laboratories in two forms: a colloidal suspension in pure water and; particles dried onto a silicon wafer. Participants prepared and analyzed these samples using either X-ray photoelectron spectroscopy (XPS) or low energy ion scattering (LEIS). Careful data analysis revealed some significant sources of discrepancy, particularly for XPS. Degradation during transportation, storage or sample preparation resulted in a variability in thickness of 53 %. The calculation method chosen by XPS participants contributed a variability of 67 %. However, variability of 12 % was achieved for the samples deposited using a single method and by choosing photoelectron peaks that were not adversely affected by instrumental transmission effects. The study identified a need for more consistency in instrumental transmission functions and relative sensitivity factors, since this contributed a variability of 33 %. The results from the LEIS participants were more consistent, with variability of less than 10 % in thickness and this is mostly due to a common method of data analysis. The calculation was performed using a model developed for uniform, flat films and some participants employed a correction factor to account for the sample geometry, which appears warranted based upon a simulation of LEIS data from one of the participants and comparison to the XPS results.

14.
Surf Interface Anal ; 48(5): 274-282, 2016 May.
Article in English | MEDLINE | ID: mdl-27087712

ABSTRACT

This paper extends a straightforward technique for the calculation of shell thicknesses in core-shell nanoparticles to the case of core-shell-shell nanoparticles using X-ray Photoelectron Spectroscopy (XPS) data. This method can be applied by XPS analysts and does not require any numerical simulation or advanced knowledge, although iteration is required in the case where both shell thicknesses are unknown. The standard deviation in the calculated thicknesses vs simulated values is typically less than 10%, which is the uncertainty of the electron attenuation lengths used in XPS analysis.

15.
Langmuir ; 31(4): 1445-53, 2015 Feb 03.
Article in English | MEDLINE | ID: mdl-25557338

ABSTRACT

Nanocrystalline thin films of PbS are obtained in a straightforward reaction by precipitation at the interface between toluene (containing a Pb precursor) and water (containing Na2S). Lead thiobiuret [Pb(SON(CN(i)Pr2)2)2] and lead diethyldithiocarbamate [Pb(S2CNEt2)2] precursors are used. The films are characterized by X-ray diffraction and electron microscopy, revealing typical particle sizes of 10-40 nm and preferred (200) orientation. Synchrotron-excited depth-profiling X-ray photoelectron spectroscopy (XPS) is used to determine the depth-dependent chemical composition as a function of surface aging in air for periods of up to 9 months. The as-synthesized films show a 1:1 Pb/S composition. Initial degradation occurs to form lead hydroxide and small quantities of surface-adsorbed -SH species. A lead-deficient Pb1-xS phase is produced as the aging proceeds. Oxidation of the sulfur occurs later to form sulfite and sulfate products that are highly localized at the surface layers of the nanocrystals. These species show logarithmic growth kinetics, demonstrating that the sulfite/sulfate layer acts to passivate the nanocrystals. Our results demonstrate that the initial reaction of the PbS nanocrystals (forming lead hydroxide) is incongruent. The results are discussed in the context of the use of PbS nanocrystals as light-harvesting elements in next-generation solar technology.

16.
Langmuir ; 30(29): 8761-9, 2014 Jul 29.
Article in English | MEDLINE | ID: mdl-25003716

ABSTRACT

Synchrotron radiation photoelectron spectroscopy and near-edge X-ray absorption fine structure (NEXAFS) techniques have been used to study the adsorption of dopamine on a rutile TiO2 (110) single crystal. Photoemission results suggest that dopamine bonds through the oxygen molecules in a bidentate fashion. From the data, it is ambiguous whether the oxygens bond to the same 5-fold coordinated surface titanium atom or bridges across two, although based on the bonding of pyrocatechol on rutile TiO2 (110), it is likely that the dopamine bridges two titanium atoms. Using the searchlight effect, the carbon K-edge near-edge X-ray absorption fine structure NEXAFS spectra recorded for dopamine on rutile TiO2 (110) show the phenyl ring to be oriented at 78° ± 5° from the surface and twisted 11 ± 10° relative to the (001) direction.


Subject(s)
Dopamine/chemistry , Nanoparticles/chemistry , Titanium/chemistry , Adsorption , Carbon/chemistry , Crystallography, X-Ray , Molecular Conformation , Oxygen/chemistry , Particle Size , Photoelectron Spectroscopy , Surface Properties , Thermodynamics
SELECTION OF CITATIONS
SEARCH DETAIL
...