Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 28
Filter
1.
J Esthet Restor Dent ; 36(7): 995-1009, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38687139

ABSTRACT

OBJECTIVES: To conduct a systematic review on the translucency of bulk-fill (BF) composite materials, evaluating the factors influencing it and its clinical implications. MATERIALS AND METHODS: A systematic search was performed on four databases (Embase, Medline/PubMed, Scopus, and Web of Science) for articles published until October 2, 2023. Search terms were: "translucency," "translucency parameter," "contrast," "contrast ratio," "bulk," "bulk-fill," "bulk fill," "composite," "resin," "resin based," "resin-based," "restoration," and "dental." In vitro studies, written in English language, investigating BF resin-based composites translucency were included. The risk of bias was performed with the RoBDEMAT tool. RESULTS: Of 590 screened articles, 13 were included in this review. They investigated 11 high-viscosity BF and 5 low viscosity ones. The limited number of the identified studies and the heterogeneity of the extracted data did not allow to conduct a meta-analysis. CONCLUSIONS: BF materials exhibit variability in translucency due to variations in experimental designs and the heterogeneous composition. CLINICAL SIGNIFICANCE: BFs may behave differently in masking the substrate or in blending capacity.


Subject(s)
Composite Resins , Composite Resins/chemistry , Humans , Materials Testing , Dental Restoration, Permanent/methods , Dental Materials/chemistry
2.
Bioengineering (Basel) ; 10(7)2023 Jul 10.
Article in English | MEDLINE | ID: mdl-37508847

ABSTRACT

Fulfilling a patient's request for a healthy, functional and esthetic smile represents a daily challenge for dental practitioners [...].

3.
Materials (Basel) ; 16(6)2023 Mar 14.
Article in English | MEDLINE | ID: mdl-36984216

ABSTRACT

BACKGROUND: To evaluate the effect of different experimental staining procedures on color stability and translucency of a nano-hybrid resin-based composite (RBC). METHODS: Forty-eight cylindrical-shaped specimens (10 × 2 mm) were prepared with a nano-hybrid RBC (Clearfil Majesty ES-2) and randomly divided in four groups according to the experimental staining procedure: G1) static immersion in a staining solution (coffee) (44 ± 1 °C); G2) staining cycling between coffee (44 ± 1°C) and distilled water (37 ± 1°C) with an experimental staining machine based on Arduino, an Open Source hardware development platform; G3) staining cycles as in G2 + brushing with a low abrasive toothpaste (Relative Dentin Abrasion RDA = 30) (Elmex Sensitive Professional); G4) staining cycles as in G3, with brushing performed with a very strong abrasive toothpaste (RDA = 90) (Lacult Active). Color parameters were recorded at the baseline (T0) after staining procedures (T1) and repolishing (T2) using a spectrophotometer. Color change (∆E00) and translucency (TP, CR) were evaluated. Data were statistically analyzed (p < 0.05). RESULTS: For ∆E00 after staining, Group 1 showed the highest color change and Group 3 the lowest. All groups were significantly different (p < 0.001) except for Group 2 vs. Group 4; after repolishing, Group 1 was significantly higher than Group 3 (p < 0.001), Group 2 (p < 0.001), and Group 4 (p = 0.003); Group 2 was higher than Group 3 (p < 0.001). For TP variable, after staining procedures, Group 2 was significantly higher than all other groups (p < 0.001), and Group 1 was significantly higher than Group 3 (p < 0.001) and Group 4 (p = 0.007). After repolishing, Group 4 was significantly lower than Group 3 (p = 0.008) and Group 2 (p = 0.027). Repolishing procedure significantly reduced color parameters. CONCLUSIONS: The investigated staining procedure induced significant differences in color stability and translucency. The use of a very strong abrasive toothpaste (RDA = 90) induced higher color change than a low abrasive one (RDA = 30). Repolishing procedures are able to partially reduce color change induced by artificial staining procedures.

4.
Compend Contin Educ Dent ; 44(2): 98-100, 2023 Feb.
Article in English | MEDLINE | ID: mdl-36802751

ABSTRACT

In recent years, the continuous evolution of dental resin-based composites (RBCs) has led to various restorative improvements, allowing for reliable clinical results together with excellent esthetics.1 A composite material can be defined as a union of two or more insoluble phases. From this union, a material with superior characteristics compared to the single components is produced. The main elements of dental RBCs are the organic resin matrix and inorganic filler particles.


Subject(s)
Composite Resins , Esthetics, Dental , Materials Testing , Dental Materials , Surface Properties
5.
J Esthet Restor Dent ; 35(4): 657-676, 2023 06.
Article in English | MEDLINE | ID: mdl-36789480

ABSTRACT

OBJECTIVES: To conduct a scoping review on color stability of bulk-fill compared to conventional resin-based composites exposed to colored beverages. MATERIALS AND METHODS: In vitro studies, investigating bulk-fill resin-based composites color stability submitted to artificial staining by colored beverages were included. Studies investigating color change induced by smoke and whitening treatments as well as papers not written in English language were excluded. A systematic search, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) was performed on four databases (Embase, Medline, Scopus, Web of Science) for articles published until October 01st 2022. The study selection was then performed by two authors who screened the abstracts independently and followed the JBI approach. RESULTS: Of 717 screened abstracts, 59 were selected for full-text analysis. Finally, 19 studies were included in this review. They investigated 19 different bulk-fill composites and different artificial-staining-by-liquids-protocols including coffee, red wine, tea, coke, and others. Seven papers reported higher color change in the investigated bulk fill materials than in conventional resin-based composites, while nine studies reported the opposite. SonicFill showed the highest color stability for most of the papers. CONCLUSIONS: The available evidence suggests that bulk-fill materials show variability in color stability. This behavior can be attributed to the heterogeneity of composition and staining procedures in the selected studies. CLINICAL SIGNIFICANCE: Clinicians should keep in mind that bulk-fill materials may change color when exposed to colorant drinks or food.


Subject(s)
Coffee , Dental Materials , Materials Testing , Staining and Labeling
6.
Polymers (Basel) ; 15(2)2023 Jan 16.
Article in English | MEDLINE | ID: mdl-36679343

ABSTRACT

BACKGROUND: This systematic review aims to evaluate the color stability of resin composite CAD/CAM blocks (CCB) when submitted to staining solutions. METHODS: A systematic search was performed on different databases (Embase, Medline, Scopus, Web of Science). Search terms were: 'polymer infiltrated', 'polymer-based', 'resin nanoceramic', 'resin ceramic', 'hybrid composite', 'hybrid ceramic', 'composite ceramic', 'resin infiltrated', 'CAD-CAM', 'CAD/CAM', 'color stability', 'staining', 'staining susceptibility', 'color change', 'color difference'. INCLUSION CRITERIA: in vitro articles published in the English language until 18 September 2022 without initial time restriction evaluating the color stability of CCB when submitted to staining solutions. EXCLUSION CRITERIA: studies investigating color change induced by smoke or whitening treatments; studies not including a clinical evaluation of the results using the thresholds for color perceptibility and acceptability. Risk of bias assessment using the QUIN tool. FINDINGS: Out of the 378 initially retrieved articles, 19 were included in this review. They investigated 17 different CCBs and different artificial staining by liquid protocols, including coffee, red wine, tea, and cola. CCBs exceeded clinical acceptability thresholds for color shift in 18 out of 19 studies, with a significantly higher color stability than conventional hybrid resin-based composites (RBCs), and a significantly lower color stability than ceramic materials. The identified differences in CCBs in color stability can be attributed to the material's composition, but also to the heterogeneity of staining procedures. Interpretation and clinical implication: Clinicians should be aware that, although to a lower degree when compared to RBCs used in direct or indirect procedures, CCBs undergo color changes to a higher degree in comparison to ceramic materials.

7.
J Esthet Restor Dent ; 35(2): 309-321, 2023 03.
Article in English | MEDLINE | ID: mdl-36602255

ABSTRACT

OBJECTIVE: To conduct a systematic review on color stability of dental resin-based composites (RBC) exposed to conventional and electronic cigarettes. MATERIALS AND METHODS: In vitro studies reporting on the color stability of RBC exposed to conventional cigarettes or to e-cigarettes: both Tobacco Heating Systems (THS) and Electronic Nicotine Delivery Systems (ENDS). The quality of the included studies was assessed with the QUIN tool (risk-of-bias tool for assessing in vitro studies conducted in dentistry). A systematic search, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) was performed on four (n = 4) databases (Embase, Medline, Scopus, Web of Science) for articles published until March 28th, 2022. RESULTS: Of the 365 screened articles, 13 were included in this review. All the included articles analyzed conventional cigarette smoke (CS), four analyzed Electronic Nicotine Delivery Systems (ENDS) and two Tobacco Heating Systems (THS). In terms of study design, smoke exposure time, smoke flow, type and number of cigarettes a high variability was reported. CONCLUSIONS: The available evidence suggests that CS smoke significantly affects color stability. Electronic cigarettes show less color change that seems to be easily recovered under clinical acceptability thresholds, although evidence is scarce. CLINICAL SIGNIFICANCE: Clinicians should be aware, and should therefore warn their patients, that RBCs are subjected to irreversible color change if exposed to smoke. Electronic cigarettes (both ENDS and THS) induce less color change that can be recovered with repolishing or whitening procedures.


Subject(s)
Electronic Nicotine Delivery Systems , Humans , Dental Materials , Nicotiana , Smoking
8.
Bioengineering (Basel) ; 9(12)2022 Dec 06.
Article in English | MEDLINE | ID: mdl-36550979

ABSTRACT

The long-term survival of restorations in the oral cavity has always been one of the most significant challenges in modern dental practice [...].

9.
Dent Mater J ; 41(6): 791-799, 2022 Nov 30.
Article in English | MEDLINE | ID: mdl-36070929

ABSTRACT

The objective of this study was to review the experimental in vitro procedures employed to assess the color stability of resin-based composites exposed to smoke. A literature search was performed on four databases (Pubmed, Scopus, Embase, and Web of Science). The quality of the included papers was assessed with the Cochrane risk-of-bias tool (RoB 2). In total, 25 studies were selected for full-text reading, from which 12 were included in the review. The assessed variables were: dimensions, shape, time before exposure, finishing, smoke-type, exposure time, brushing simulation, color, measuring system, repolishing. A disk-shaped specimen was used in most studies (n=10) with a 2 mm thickness (n=7) in custom made devices equipped with vacuum pumps or in Vitrocell systems. Spectrophotometers were the most used devices (n=11). Color differences were quantified with ΔE (n=12), ΔE00 (n=1). The large variety of staining procedures suggests the need for standardization.


Subject(s)
Composite Resins , Dental Materials , Color , Surface Properties , Smoking , Materials Testing
10.
Materials (Basel) ; 15(11)2022 May 24.
Article in English | MEDLINE | ID: mdl-35683057

ABSTRACT

Several lubricant materials can be used to model resin-based composites (RBCs) during restorative procedures. Clinically, instruments or brushes are wet with bonding agents (BAs) or modeling liquids (MLs) for sculpturing purposes. However, a knowledge gap exists on their effects on the mechanical properties of RBCs, requiring greater insight. Five databases were searched, including 295 in vitro studies on the use of lubricant materials for modeling RBCs during restorative procedures. Only articles in the English language were included, with no limits on the publication date. The last piece of research was dated 24 March 2022. In total, 16 studies were included in the review process, together with a paper retrieved after screening references. A total of 17 BAs and 7 MLs were investigated. Tensile (n = 5), flexural strength (n = 2), water sorption (n = 2), color stability (n = 8) and translucency (n = 3), micro-hardness (n = 4), roughness (n = 3), degree of conversion (n = 3), and monomer elution (n = 2) tests were carried out. In general, a maximum of 24 h of artificial storage was performed (n = 13), while four papers tested the specimens immediately. The present review identifies the possibilities and limitations of modeling lubricants used during restorative procedures on the mechanical, surface, and optical properties of RBCs. Clinicians should be aware that sculpturing RBCs with modeling resins might influence the composite surface properties in a way that is material-dependent.

11.
J Esthet Restor Dent ; 34(6): 865-887, 2022 09.
Article in English | MEDLINE | ID: mdl-35396818

ABSTRACT

OBJECTIVE: The objective of this study was to review the experimental staining procedures performed in in-vitro studies for evaluating color stability of resin-based composites used for direct restorations. OVERVIEW: A review was performed with the purpose to identify in vitro procedures carried out to establish staining and color stability of resin-based composites used for direct restorations. A literature search was performed on four online databases (PubMed, Scopus, Embase and Web of Science) for articles published from January 1st 2001 till March 20th 2021, using a combination of free words and Medical Subject Headings (MESH) terms: "Composite Resins" AND "Color Stability" OR "Staining." Two reviewers screened titles and/or abstracts of 1728 unique studies. In total, 208 studies were selected for full-text reading, from which 178 were included in the review. The assessed variables were specimen dimensions, shape, and surface finishing; time before immersion; staining media type, dwell time, temperature and renewal interval; type of composite; color and translucency assessment parameters and measuring system. One hundred and seventy-eight articles analyzed color stability with staining liquids. Coffee was the most used staining medium (n = 102), followed by tea (n = 61), and red wine (n = 55). A disc-shaped specimen was used in most studies (n = 170) with a 2 mm thickness (n = 116). Spectrophotometers were the most used color assessment devices (n = 154), followed by colorimeters (n = 17). Color differences were quantified with ΔE (n = 154), ΔE00 (n = 23). Acceptability and or perceptibility thresholds were also taken into consideration (n = 126). CONCLUSIONS: The large variety of staining procedure suggests the need for standardization. CLINICAL SIGNIFICANCE: Aesthetic failure due to discoloration is a relevant clinical problem. Evaluating benefits and drawbacks of resin based composites artificial staining procedures will improve to predict materials clinical performances.


Subject(s)
Dental Materials , Color , Materials Testing , Staining and Labeling , Surface Properties
12.
Minerva Dent Oral Sci ; 71(4): 212-222, 2022 Aug.
Article in English | MEDLINE | ID: mdl-34851068

ABSTRACT

BACKGROUND: COVID-19 pandemic has disrupted the daily work of the dental professionals, assuming unprecedented economic, managerial, and psychological implications. The aim of this cross-sectional survey was to analyze the extent of the impact linked to the imposed working conditions on the Italian dental team. METHODS: The survey was administered with a web-based form (Google Forms®; Google LLC, Mountain View, CA, USA) to Italian dentists and hygienists. To be enrolled in the study, participants had to reach the adulthood and agree to sign the privacy policy. The impact of COVID-19 was analyzed through a 27-items questionnaire, which was divided into 4 main domains: personal protective equipment (PPE), operative procedures, secretarial organization, and self-reported quality of life (including e-learning appraisal). RESULTS: A total of 614 between dentists and dental hygienists completed the questionnaire. Compared to the prepandemic period, the use of PPE such as face shields, surgical caps and disposable gowns were implemented after the COVID-19 outbreak. Almost the whole interviewed (99.9%) received the COVID-19 vaccine. An increased use of preoperatory mouthwashes and rubber dam was referred during the pandemic, while aerosolization (i.e., ultrasound) was drastically reduced. A certain number of respondents (30% dentists, 27% hygienists) suffered from work-related stresses during the pandemic until they desired to change jobs. E-learning was considered beneficial for the 70% of participants. CONCLUSIONS: COVID-19 pandemic influenced dental professionals' life, leading to a rearrangement of professional, managerial, and cultural life for both dentists and hygienists even after 1 year from the outbreak.


Subject(s)
COVID-19 , Adult , COVID-19/epidemiology , COVID-19 Vaccines , Cross-Sectional Studies , Dentists/psychology , Humans , Pandemics/prevention & control , Quality of Life , SARS-CoV-2
13.
Dent J (Basel) ; 9(7)2021 Jul 07.
Article in English | MEDLINE | ID: mdl-34356195

ABSTRACT

In esthetic restorations of anterior teeth the clinician has to manage several aspects in order to have a predictable outcome. A deep knowledge of the anatomy as well as the adhesive procedures and the optical properties of resin-based composites are mandatory to achieve esthetic results. Contemporary restorative materials present either several shades and different translucency properties and therefore they are able to mimic teeth's optical behavior thus providing a natural aspect to anterior restorations. The wrong thickness of different composite layers may provide unpleasant results such as low value (grayish) restorations that often requires reintervention. A precise step-by-step procedure is therefore mandatory to provide the proper shade at the correct place. There is therefore the need of some corrections and adjustments during the layer procedure in order to avoid errors in shade positioning that could affect final result. The authors present a case series (six clinical cases) treated with the proposed technique with up to five years follow-up.

14.
J Clin Exp Dent ; 8(4): e437-e441, 2016 Oct.
Article in English | MEDLINE | ID: mdl-27703613

ABSTRACT

BACKGROUND: The efficacy of endodontic irrigation procedures can be compromised by the complexity of the root canal system. Delivering irrigants to the apical third of curved canals presents a particular challenge to endodontists. This study compared the effects of two ultrasonic irrigation techniques on the penetration of sodium hypochlorite into the main canal and simulated lateral canals of curved roots in extracted teeth. MATERIAL AND METHODS: Two sets of simulated lateral canals were created at 2, 4, and 6 mm from the working length in 60 single-rooted teeth (6 canals/tooth, n = 360 canals). The teeth were randomly divided into three experimental irrigation groups: group 1 (n = 20), positive pressure irrigation (PPI); group 2 (n = 20), passive ultrasonic irrigation (PUI); and group 3 (n = 20), continuous ultrasonic irrigation (CUI). To assess the irrigation solution penetration, 20% Chinese ink (Sanford Rotring GmbH, Hamburg, Germany) was added to a 5% sodium hypochlorite solution and delivered into the curved root canals. The penetration of contrast solution into the simulated lateral canals was scored by counting the number of lateral canals (0-2) penetrated to at least 50% of the total length. RESULTS: The CUI group showed significantly higher (P < 0.05) irrigant penetration into the lateral canals and into the apical third of the main canals. The PPI group showed significantly lower sodium hypochlorite penetration (P < 0.001) into the main and lateral canals compared with that in the CUI and PUI groups. Significantly higher irrigant penetration was observed in the PUI group than the PPI group. CONCLUSIONS: Using CUI as the final rinse significantly increased the penetration of irrigant solution into the simulated lateral canals and apical third of curved roots. Key words:Continuous ultrasonic irrigation, curved root canals, passive ultrasonic irrigation, positive pressure irrigation, root canal irrigation.

15.
Minerva Stomatol ; 65(4): 223-30, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27374362

ABSTRACT

BACKGROUND: Scientific studies show a possible influence of intercellular and intracellular proteins (VEGF) on the development of physiological and pathological tissue. VEGF, a key regulator of angiogenesis, it would seem essential to take action during the embryonic development of the dental germ. The purpose of the study is to investigate the importance of the enzymatic activity of VEGF through protein quantification at different stages of tooth germ development. METHODS: The quantification of VEGF protein was performed by 3 different laboratory tests: Western-blot analysis, semi-quantitative reverse transcriptase-polymerase chain reaction analysis (RT-PCR) and finally immunohistochemical analysis. Cell cultures of tooth tissue examined are: endothelial cells, stellate reticulum cells, odontoblasts and ameoblast. RESULTS: The VEGF peptide seems to induce an intense cell proliferation, not concomitant with differentiation towards the endothelial line. The expression of VEGF in the inner enamel epithelium (ameloblasts) would seem to depend on the stage of differentiation, leading us to deduce that VEGF and its respective receptor are expressed in dental germ and that induce alterations not only on the vascularization, but also on the inner epithelium activation and then on dental enamel development, respectively on cap and bell stages of embryogenesis. CONCLUSIONS: In our survey, the positive expression of VEGF in all the samples examined, might suggest a fundamental role of angiogenic gene proteins during all stages of embryonic tooth development. It is also characteristic the behavior of stellate reticulum cells, with a significant reduction in VEGF action between early and late stage, which could suggest a possible role of stellate reticulum cells, which would be able to promote and maintain an adequate energy supply to the tissues during early and late stages of differentiation and proliferation.


Subject(s)
Tooth Germ/metabolism , Vascular Endothelial Growth Factor A/analysis , Adolescent , Ameloblasts/metabolism , Blotting, Western , Child , Endothelial Cells/metabolism , Female , Gene Expression Regulation, Developmental , Humans , Male , Odontoblasts/metabolism , RNA, Messenger/biosynthesis , Reverse Transcriptase Polymerase Chain Reaction , Tooth Germ/growth & development , Vascular Endothelial Growth Factor A/biosynthesis , Young Adult
16.
J Endod ; 38(5): 688-91, 2012 May.
Article in English | MEDLINE | ID: mdl-22515904

ABSTRACT

INTRODUCTION: Complete endodontic system disinfection requires the removal of vital and necrotic pulp tissue, microorganisms, and toxins. The purpose of this study was to compare the effects of 2 ultrasonic irrigation techniques on the penetration of sodium hypochlorite into the main canal and simulated lateral canals of extracted teeth. METHODS: Two simulated lateral canals each were created 2, 4, and 6 mm from the working length in 60 single-rooted teeth (6 canals/tooth, n = 360). To resemble the clinical situation, a closed system was created in each tooth. The teeth were randomly assigned to 3 experimental irrigation groups: group 1 (n = 20), positive pressure irrigation (PPI); group 2 (n = 20), passive ultrasonic irrigation (PUI); and group 3 (n = 20), continuous ultrasonic irrigation (CUI). Samples were evaluated by direct observation of still images recorded under a dental operating microscope. To examine irrigating solution penetration, 20% Chinese ink (Sanford Rotring GmbH, Hamburg, Germany) was added to a 5% sodium hypochlorite solution and delivered into the root canals. RESULTS: The results showed a significantly higher (P < .05) penetration of irrigant into the lateral canals in the CUI group. PUI and CUI did not differ significantly in solution penetration into the apical thirds of the main canals. The PPI group showed a significantly lower penetration of sodium hypochlorite into the main and lateral canals compared with the CUI and PUI groups. CONCLUSIONS: CUI as a final rinse significantly increased the penetration of irrigating solution into simulated lateral canals.


Subject(s)
Dental Pulp Cavity/drug effects , Root Canal Irrigants/administration & dosage , Root Canal Preparation/methods , Sodium Hypochlorite/administration & dosage , Carbon , Coloring Agents , Dental Pulp Cavity/pathology , Edetic Acid/administration & dosage , Humans , Materials Testing , Microscopy , Needles , Pressure , Root Canal Preparation/instrumentation , Sonication/methods , Syringes , Therapeutic Irrigation/methods , Time Factors , Tooth Apex/drug effects , Tooth Apex/pathology , Ultrasonics
17.
J Endod ; 38(4): 505-9, 2012 Apr.
Article in English | MEDLINE | ID: mdl-22414838

ABSTRACT

INTRODUCTION: This study compared the canal curvature and axis modification after instrumentation with WaveOne Primary reciprocating files (Dentsply Maillefer, Ballaigues, Switzerland) and nickel-titanium (NiTi) rotary ProTaper (Dentsply Maillefer). METHODS: Thirty ISO 15, 0.02 taper, Endo Training Blocks (Dentsply Maillefer) were used. In all specimens, the glide path was achieved with PathFile 1, 2, and 3 (Dentsply Maillefer) at the working length (WL). Specimens were then assigned to 1 of 2 groups for shaping: specimens in group 1 were shaped with ProTaper S1-S2-F1-F2 at the WL and specimens in group 2 were shaped with WaveOne Primary reciprocating files at the WL. Pre- and postinstrumentation digital images were superimposed and processed with Matlab r2010b (The MathWorks Inc, Natick, MA) software to analyze the curvature-radius ratio (CRr) and the relative axis error (rAe), representing canal curvature modification. Data were analyzed with one-way balanced analyses of variance at 2 levels (P < .05). RESULTS: The instrument factor was extremely significant for both the CRr parameter (F(1) = 9.59, P = .004) and the rAe parameter (F(1) = 13.55, P = .001). CONCLUSIONS: Canal modifications are reduced when the new WaveOne NiTi single-file system is used.


Subject(s)
Dental Pulp Cavity/anatomy & histology , Root Canal Preparation/instrumentation , Dental Alloys/chemistry , Equipment Design , Humans , Image Processing, Computer-Assisted , Materials Testing , Models, Anatomic , Nickel/chemistry , Photography , Root Canal Preparation/standards , Stress, Mechanical , Surface Properties , Titanium/chemistry
18.
J Endod ; 38(3): 389-93, 2012 Mar.
Article in English | MEDLINE | ID: mdl-22341081

ABSTRACT

INTRODUCTION: X-ray computed micro-tomography scanning allows high-resolution 3-dimensional imaging of small objects. In this study, micro-CT scanning was used to compare the ability of manual and mechanical glide path to maintain the original root canal anatomy. METHODS: Eight extracted upper first permanent molars were scanned at the TOMOLAB station at ELETTRA Synchrotron Light Laboratory in Trieste, Italy, with a microfocus cone-beam geometry system. A total of 2,400 projections on 360° have been acquired at 100 kV and 80 µA, with a focal spot size of 8 µm. Buccal root canals of each specimen (n = 16) were randomly assigned to PathFile (P) or stainless-steel K-file (K) to perform glide path at the full working length. Specimens were then microscanned at the apical level (A) and at the point of the maximum curvature level (C) for post-treatment analyses. Curvatures of root canals were classified as moderate (≤35°) or severe (≥40°). The ratio of diameter ratios (RDRs) and the ratio of cross-sectional areas (RAs) were assessed. For each level of analysis (A and C), 2 balanced 2-way factorial analyses of variance (P < .05) were performed to evaluate the significance of the instrument factor and of canal curvature factor as well as the interactions of the factors both with RDRs and RAs. RESULTS: Specimens in the K group had a mean curvature of 35.4° ± 11.5°; those in the P group had a curvature of 38° ± 9.9°. The instrument factor (P and K) was extremely significant (P < .001) for both the RDR and RA parameters, regardless of the point of analysis. CONCLUSIONS: Micro-CT scanning confirmed that NiTi rotary PathFile instruments preserve the original canal anatomy and cause less canal aberrations.


Subject(s)
Dental Alloys/chemistry , Dental Pulp Cavity/diagnostic imaging , Imaging, Three-Dimensional/methods , Molar/diagnostic imaging , Nickel/chemistry , Root Canal Preparation/instrumentation , Titanium/chemistry , X-Ray Microtomography/methods , Anatomy, Cross-Sectional/methods , Cone-Beam Computed Tomography/methods , Humans , Image Processing, Computer-Assisted/methods , Lubricants/chemistry , Maxilla/diagnostic imaging , Microsurgery/methods , Root Canal Irrigants/administration & dosage , Root Canal Preparation/methods , Sodium Hypochlorite/administration & dosage , Stainless Steel/chemistry , Tooth Apex/diagnostic imaging
19.
J Endod ; 38(1): 32-6, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22152616

ABSTRACT

INTRODUCTION: This prospective randomized clinical trial evaluated the incidence of postoperative pain after glide path performed with PathFile (PF) (Dentsply Maillefer, Ballaigues, Switzerland) versus stainless-steel K-file (KF). METHODS: In 149 subjects, the mechanical glide path was performed with nickel-titanium (NiTi) rotary PF; in 146 subjects, the manual glide path was performed with stainless-steel KFs. Postoperative pain, analgesics consumption, and the number of days to complete pain resolution were evaluated in the following 7 days. An analysis of variance model for repeated measures was used to compare the variation of pain-scale values (P < .05). The Student's t test for continuous variables normally distributed, the nonparametric Mann-Whitney U test for the nonnormally distributed variables, and the chi-square test for dichotomous variables were used (P < .05). Despite homogeneous baseline conditions at diagnosis, tooth type, pain prevalence, and scores, the postoperative pain prevalence curves in PF group evidenced a more favorable trend in terms of time to pain resolution compared with the KF group (P = .004). The difference was also evident in the model adjusted for analgesics consumption in both groups (P = .012). The mean analgesics intake per subject was significantly higher in the KF group (3.7 ± 2.2) compared with the PF group (2 ± 1.7) (P < .001). Mean pain stop values were also significantly higher in the KF group (2.7) compared with the PF group (1.7) (P = .001). CONCLUSIONS: The glide path with NiTi Rotary PF leads to less postoperative pain and faster symptom resolution.


Subject(s)
Pain, Postoperative/etiology , Root Canal Preparation/instrumentation , Adolescent , Adult , Aged , Analgesics/therapeutic use , Dental Alloys , Dental Pulp Cavity/pathology , Dental Pulp Necrosis/therapy , Equipment Design , Follow-Up Studies , Humans , Middle Aged , Nickel , Pain Measurement , Periapical Periodontitis/therapy , Prospective Studies , Pulpitis/therapy , Root Canal Preparation/methods , Stainless Steel , Titanium , Young Adult
20.
J Endod ; 38(1): 101-4, 2012 Jan.
Article in English | MEDLINE | ID: mdl-22152630

ABSTRACT

INTRODUCTION: This study evaluated the influence of glide path on canal curvature and axis modification after instrumentation with WaveOne Primary reciprocating files. METHODS: Thirty ISO 15, 0.02 taper Endo Training Blocks were used. In group 1, glide path was created with PathFile 1, 2, and 3 at working length, whereas in group 2, glide path was not performed. In both groups, canals were shaped with WaveOne Primary reciprocating files at working length. Preinstrumentation and postinstrumentation digital images were superimposed and processed with Matlab r2010b software to analyze the curvature radius ratio (CRr) and the relative axis error (rAe), representing canal curvature modification. Data were analyzed with 1-way balanced analyses of variance at 2 levels (P < .05). RESULTS: Glide path was found to be extremely significant for both CRr parameter (F = 9.59; df = 1; P = .004) and rAe parameter (F = 13.55; df = 1; P = .001). CONCLUSIONS: Canal modifications seem to be significantly reduced when previous glide path is performed by using the new WaveOne nickel-titanium single-file system.


Subject(s)
Dental Pulp Cavity/anatomy & histology , Root Canal Preparation/instrumentation , Algorithms , Coloring Agents , Dental Alloys/chemistry , Equipment Design , Humans , Image Processing, Computer-Assisted/methods , Models, Anatomic , Nickel/chemistry , Photography , Root Canal Preparation/methods , Root Canal Preparation/standards , Surface Properties , Titanium/chemistry
SELECTION OF CITATIONS
SEARCH DETAIL
...